• Title/Summary/Keyword: Pilot Unit

Search Result 219, Processing Time 0.03 seconds

Effective Textile Wastewater Treatment : Pilot-Scale Study (파일롯 스케일에서의 효율적인 염색폐수 처리)

  • Park, Chulhwan;Kim, Tak-Hyun;Lee, Jinwon;Kim, Seung-Wook;Kim, Sangyong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2001.05a
    • /
    • pp.82-83
    • /
    • 2001
  • Selected microbes was applied to the treatment of textile wastewater with support particles. To enhance the treatment efficiency, biological treatment was achieved as first process. Wastewater with a COD of 870 ppm and color of 1340 PtCo unit was continuously treated in a 1.8 ton capacity reactor. In the case of combined processes, the effluent COD concentration and color were 40 ppm (95.4% reduction) and 20 PtCo unit (98.5% reduction).

The Effect of Fixed Media and Recycling Ratio on Nutrients Removal in a Pilot-Scale Wastewater Treatment Unit (고정식 담체 유무와 반송비에 따른 소규모 하수처리 시스템 내 영양염류 제거 특성)

  • Hwang, Jae-Hoon;Cho, Dong-Wan;Kim, Chung-Hwan;Jeon, Byong-Hun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.6
    • /
    • pp.449-455
    • /
    • 2013
  • The effect of recycling ratio and fixed media on nitrate and phosphate removal was investigated in a pilot-scale wastewater treatment unit using synthetic wastewater. Addition of fixed media increased nitrate removal from 45 to 58% while no noticeable change was observed for Chemical Oxygen Demand (COD) and phosphate removal (<5%). Nitrate removal efficiency also enhanced (Ca 7%) when the influent wastewater flow was doubled (2Q), however phosphate removal was decreased from 40.9 to 26.6% with the increasing recycling rate. The attached biomass analysis showed the presence of bacteria (73.4 $mg/cm^2$) on the surface of added media in anoxic reactor. Pseudomonas aeruginosa a common denitrifying bacterium dominated the bacterial growth (58%) in the anoxic reactor which was determined using Fluorescence In Situ Hybridization (FISH) analysis.

Fuzzy Logic Control of Rotating Drum Bioreactor for Improved Production of Amylase and Protease Enzymes by Aspergillus oryzae in Solid-State Fermentation

  • Sukumprasertsri, Monton;Unrean, Pornkamol;Pimsamarn, Jindarat;Kitsubun, Panit;Tongta, Anan
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.3
    • /
    • pp.335-342
    • /
    • 2013
  • In this study, we compared the performance of two control systems, fuzzy logic control (FLC) and conventional control (CC). The control systems were applied for controlling temperature and substrate moisture content in a solidstate fermentation for the biosynthesis of amylase and protease enzymes by Aspergillus oryzae. The fermentation process was achieved in a 200 L rotating drum bioreactor. Three factors affecting temperature and moisture content in the solid-state fermentation were considered. They were inlet air velocity, speed of the rotating drum bioreactor, and spray water addition. The fuzzy logic control system was designed using four input variables: air velocity, substrate temperature, fermentation time, and rotation speed. The temperature was controlled by two variables, inlet air velocity and rotational speed of bioreactor, while the moisture content was controlled by spray water. Experimental results confirmed that the FLC system could effectively control the temperature and moisture content of substrate better than the CC system, resulting in an increased enzyme production by A. oryzae. Thus, the fuzzy logic control is a promising control system that can be applied for enhanced production of enzymes in solidstate fermentation.

Development of implant loading device for animal study about various loading protocol: a pilot study

  • Yoon, Joon-Ho;Park, Young-Bum;Cho, Yuna;Kim, Chang-Sung;Choi, Seong-Ho;Moon, Hong-Seok;Lee, Keun-Woo;Shim, June-Sung
    • The Journal of Advanced Prosthodontics
    • /
    • v.4 no.4
    • /
    • pp.227-234
    • /
    • 2012
  • PURPOSE. The aims of this pilot study were to introduce implant loading devices designed for animal study and to evaluate the validity of the load transmission ability of the loading devices. MATERIALS AND METHODS. Implant loading devices were specially designed and fabricated with two implant abutments and cast metal bars, and orthodontic expansion screw. In six Beagles, all premolars were extracted and two implants were placed in each side of the mandibles. The loading device was inserted two weeks after the implant placement. According to the loading protocol, the load was applied to the implants with different time and method, simulating early, progressive, and delayed loading. The implants were clinically evaluated and the loading devices were removed and replaced to the master cast, followed by stress-strain analysis. Descriptive statistics of remained strain (${\mu}{\varepsilon}$) was evaluated after repeating three cycles of the loading device activation. Statistic analysis was performed using nonparametric, independent t-test with 5% significance level and Friedman's test was also used for verification. RESULTS. The loading devices were in good action. However, four implants in three Beagles showed loss of osseointegration. In stress-strain analysis, loading devices showed similar amount of increase in the remained strain after applying 1-unit load for three times. CONCLUSION. Specialized design of the implant loading device was introduced. The loading device applied similar amount of loads near the implant after each 1-unit loading. However, the direction of the loads was not parallel to the long axis of the implants as predicted before the study.

A study on the improvement of cleaning performance in bag-filter (여과집진기의 탈진 거동 개선에 관한 연구)

  • Hong, Sung-Gil;Kum, Young-Ho;Shon, Byung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1571-1578
    • /
    • 2015
  • The cleaning characteristics of pulse air jet type cleaning system which is widely applied in the industries were identified by utilizing the computational fluid dynamics (CFD) and the cleaning performance in modified shape of dedusting unit was compared in this study. The review on each shape of cleaning part showed that the case of installing the nozzle on the blow tube (Case-3) and the case of installing the double intaking tube to the venturi (Case-4 and Case-5) were more excellent than the structure (Case-1). Also, the optimal venturi shape was designed and examined its applicability to the site in a pilot scale plant. A combined system of a blow tube and a venturi proposed by this study turned out to be very effective for concentrating an cleaning air compared to existing systems, such as using only blow tube and combines the blow tube and venturi. In addition, as a result of installing and testing a venturi proposed by this study, the cleaning frequency and cleaning time were much improved compared to a case of using a commercial venturi that is under use at the industrial sites.

Current Status of the Pediatric Palliative Care Pilot Project in South Korea Based on the Experience of a Single Center

  • Sun Hee Choi;Na Ri Yoon;Yeonhee Lee
    • Journal of Hospice and Palliative Care
    • /
    • v.26 no.2
    • /
    • pp.51-59
    • /
    • 2023
  • Purpose: We evaluated the status of patients enrolled in South Korea's pediatric palliative care pilot project based on the experience of a single center. This study examined factors related to end-of-life services and differences in medical costs. Methods: The medical records of 120 patients referred by a pediatric palliative care team were analyzed retrospectively. Data from July 1 to February 28, 2022 were collected and analyzed using the chi-square test and the Mann-Whitney U test. Results: Volunteer programs and psychological support (100%), family support and education (99.2%), and financial support through institutional linkage (62.5%) were provided to the participants. In the deceased group, there were no significant differences in general characteristics, which included age, gender, primary disease, religion, duration of hospitalization in an intensive care unit (ICU) and non-intensive care unit (non-ICU). However, the ICU group had fewer opportunities to access individual pain and physical symptom management than the non-ICU group and there were limitations in linking with external resources. Medical expenses were significantly different for the ICU group, with a 3-times higher average cost than the non-ICU group. Conclusion: Although an individualized approach is needed for each patient in pediatric palliative care, psychosocial care is essential. In addition, if early intervention for end-of-life pediatric patients is available from a palliative care team, the cost burden of medical care for patients and their families should be minimal.

Optimization of Supercritical Water Oxidation(SCWO) Process for Decomposing Nitromethane (Nitromethane 분해를 위한 초임계수 산화(SCWO) 공정 최적화)

  • Han, Joo Hee;Jeong, Chang Mo;Do, Seung Hoe;Han, Kee Do;Sin, Yeong Ho
    • Korean Chemical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.659-668
    • /
    • 2006
  • The optimization of supercritical water oxidation (SCWO) process for decomposing nitromethane was studied by means of a design of experiments. The optimum operating region for the SCWO process to minimize COD and T-N of treated water was obtained in a lab scale unit. The authors had compared the results from a SCWO pilot plant with those from a lab scale system to explore the problems of scale-up of SCWO process. The COD and T-N in treated waters were selected as key process output variables (KPOV) for optimization, and the reaction temperature (Temp) and the mole ratio of nitromethane to ammonium hydroxide (NAR) were selected as key process input variables (KPIV) through the preliminary tests. The central composite design as a statistical design of experiments was applied to the optimization, and the experimental results were analyzed by means of the response surface method. From the main effects analysis, it was declared that COD of treated water steeply decreased with increasing Temp but slightly decreased with an increase in NAR, and T-N decreased with increasing both Temp and NAR. At lower Temp as $420{\sim}430^{\circ}C$, the T-N steeply decreased with an increase in NAR, however its variation was negligible at higher Temp above $450^{\circ}C$. The regression equations for COD and T-N were obtained as quadratic models with coded Temp and NAR, and they were confirmed with coefficient of determination ($r^2$) and normality of standardized residuals. The optimum operating region was defined as Temp $450-460^{\circ}C$ and NAR 1.03-1.08 by the intersection area of COD < 2 mg/L and T-N < 40 mg/L with regression equations and considering corrosion prevention. To confirm the optimization results and investigate the scale-up problems of SCWO process, the nitromethane was decomposed in a pilot plant. The experimental results from a SCWO pilot plant were compared with regression equations of COD and T-N, respectively. The results of COD and T-N from a pilot plant could be predicted well with regression equations which were derived in a lab scale SCWO system, although the errors of pilot plant data were larger than lab ones. The predictabilities were confirmed by the parity plots and the normality analyses of standardized residuals.

무인항공기의 각속도 기반 자동비행제어시스템 개발

  • Lee, Jang-Ho;Ryu, Hyeok;Kim, Jae-Eun;Ahn, Iee-Gi;Kim, Eung-Tai
    • Aerospace Engineering and Technology
    • /
    • v.4 no.2
    • /
    • pp.7-14
    • /
    • 2005
  • This paper describes development of automatic flight control system for an unmanned target drone. Current target drone is operated by pilot control of on-board servo motor via remote control system. Automatic flight control system for the target drone greatly reduces work load of ground pilot and can increase application area of the drone. Most UAVs being operated nowdays use high-priced sensors as AHRS and IMU to measure the attitude, but those are costly. This paper introduces the development of low-cost automatic flight control system with low-cost sensors. The integrated automatic flight control system has been developed. The performance of automatic flight control system is verified by flight test.

  • PDF

The Measurement of Membrane Deformation Behavior in Kogas Pilot LNG Storage Tank by the use of Mechanical/Electrical Sensor (I) (기계적/전기적 측정 센서를 이용한 Kogas Pilot LNG 저장탱크 멤브레인 변형 거동 측정(I))

  • Kim Y.K.;Hong S.H,;Oh B.T.;Yoon I.S.;Kim J.H.;Kim S.S.
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.3 s.20
    • /
    • pp.13-17
    • /
    • 2003
  • A membrane unit for Liquefied Natural Gas (LNG) storage tank is a structural member which is designed specifically for preventing undesirable LNG leakage. Membrane units have to endure gas and liquid pressures by LNG and thermal stresses by the contact with cryogenic liquid of $-162^{\circ}C$. It is of importance to assure the strengths of membrane by experimental stress analysis under the temperature of LNG. In this paper, we proposed measurement system using commercial electrical strain gage and mechanical extension meter designed for this study.

  • PDF

A Study on Stand-Alone Electric Power Generator Using Bridge Vibration (교량진동을 이용한 진동형 자가발전기에 대한 연구)

  • 최남섭
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.05a
    • /
    • pp.313-316
    • /
    • 2003
  • This paper presents stand-alone electric power generator using bridge vibration for charging system of health monitoring sensor unit of bridge structure. In this paper, a novel electric power generator utilizing vertical vibration is proposed, which has minimum effect of armature reaction, and the related mechanical and electrical design equations are obtained and then a pilot electric power generator has been implemented. Moreover, the free oscillation test reveals that diode characteristics of rectifier is dominant factor in charging process. Also, simulation results with the Namhae bridge data showed the validity and effectiveness for stand-alone electric power generation.

  • PDF