• 제목/요약/키워드: Pilot Receiver

Search Result 119, Processing Time 0.039 seconds

Design of A Stateless Minimum-Bandwidth Binary Line Code MB46d (Stateless 최소대역폭 2진 선로부호 MB46d의 설계)

  • Lee, Dong-Il;Kim, Dae-Young
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.11-18
    • /
    • 1998
  • A binary line code, called MB46d, is designed by use of the BUDA(Binary Unit DSV and ASV) cell concept to retain the property of being runlength limited, DC tree, and with a power spectral null at the Nyquist frequency. This new code is a stateless line code with a simple encoding and a decoding rule and enables efficient error monitoring. The power spectrum and the eye pattern of the new line code are simulated for a minimum-bandwidth digital transmission system where the sinc function is used as a basic pulse. The obtained power null at the Nyquist frequency is wide enough to enable easy band-limiting as well as secure insertion of a clock pilot where necessary. The eye is also substantially wide to tolerate a fair amount of timing jitter in the receiver.

  • PDF

Design and Implementation of a TTIB Fading Compensation Systems for Narrowband Mobile Communication Systems (협대역 이동통신시스템에서 TTIB를 이용한 페이딩 보상 시스템의 설계 및 구현)

  • Lee, Byeong-Ro;Lim, Young-Hoe;Lim, Dong-MIn
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.19-26
    • /
    • 1998
  • In this paper, we studied the design and implementation of fading compensation systems at aspects of narrowband mobile communication using TTIB SSB. The mobile radio channel with multipath fading places fundamental limitations on the performance of wireless communication systems. The multipath fading is compensated using pilot tone in TTIB SSB. The TTIB transceiver was implemented using the prevailing digital signal processing (DSP) techniques and compensation for the multipath fading was incorporated in the receiver in the form of DSP algorithm. In order to evaluate fading compensation performance in TTIB transceiver, we first used computer simulation. In the simulation results, we found that the TTIB transceiver could compensate for the multipath fading as expected. Second, we carried out some experiments on TTIB transceiver implementation with DSP boards and later with hardwares including RF circuits with center frequency of 145MHz. Through these experiments, we found that fading compensation performance in TTIB transceiver was almost as good as that obtained from simulation.

  • PDF

Development of Korean Intensive Care Delirium Screening Tool (KICDST) (중환자 섬망 선별도구 개발)

  • Nam, Ae-Ri-Na;Park, Jee-Won
    • Journal of Korean Academy of Nursing
    • /
    • v.46 no.1
    • /
    • pp.149-158
    • /
    • 2016
  • Purpose: This study was done to develop of the Korean intensive care delirium screening tool (KICDST). Methods: The KICDST was developed in 5 steps: Configuration of conceptual frame, development of preliminary tool, pilot study, reliability and validity test, development of final KICDST. Reliability tests were done using degree of agreement between evaluators and internal consistency. For validity tests, CVI (Content Validity Index), ROC (Receiver Operating Characteristics) analysis, known group technique and factor analysis were used. Results: In the reliability test, the degree of agreement between evaluators showed .80~1.00 and the internal consistency was KR-20=.84. The CVI was .83~1.00. In ROC analysis, the AUC (Area Under the ROC Curve) was .98. Assessment score was 4 points. The values for sensitivity, specificity, correct classification rate, positive predictive value, and negative predictive value were found to be 95.0%, 93.7%, 94.4%, 95.0% and 93.7%, respectively. In the known group technique, the average delirium screening tool score of the non-delirium group was $1.25{\pm}0.99$ while that of delirium group was $5.07{\pm}1.89$ (t= - 16.33, p <.001). The factors were classified into 3 factors (cognitive change, symptom fluctuation, psychomotor retardation), which explained 67.4% of total variance. Conclusion: Findings show that the KICDST has high sensitivity and specificity. Therefore, this screening tool is recommended for early identification of delirium in intensive care patients.

PID control using 8-bit microcontroller (8비트 마이크로컨트롤러를 사용한 PID 제어)

  • Lee, Donghee;Moon, Sangook
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.407-408
    • /
    • 2016
  • A drone has been popularized to such an extent as to be seen in the near parks recently. The drone refers to an unmanned aerial vehicle(UVA) which can fly and be steered by a radio wave without a pilot and it has a airplane or helicopter shape. The drone was first started to be used from military purpose, but its usage has been expanded to the private such as broadcast shooting, crop-dusting, field discovery and hobby. However the drone that we can see often in the market is expansive, hard to be repaired when it broken down and has a discomfort of the short flight time. In this paper, to solve an uncomfortable talk on the cheap ATmega128 Using (Quad copter) drone for implementation. Axes gyroscope and accelerometers mcu between posture an attitude control, communications through drone control, pid. Receiver input them into transmitter signals of movements to control drone c the programming was implemented in on the basis of language.

  • PDF

The prognostic value of median nerve thickness in diagnosing carpal tunnel syndrome using magnetic resonance imaging: a pilot study

  • Lee, Sooho;Cho, Hyung Rae;Yoo, Jun Sung;Kim, Young Uk
    • The Korean Journal of Pain
    • /
    • v.33 no.1
    • /
    • pp.54-59
    • /
    • 2020
  • Background: The median nerve cross-sectional area (MNCSA) is a useful morphological parameter for the evaluation of carpal tunnel syndrome (CTS). However, there have been limited studies investigating the anatomical basis of median nerve flattening. Thus, to evaluate the connection between median nerve flattening and CTS, we carried out a measurement of the median nerve thickness (MNT). Methods: Both MNCSA and MNT measurement tools were collected from 20 patients with CTS, and from 20 control individuals who underwent carpal tunnel magnetic resonance imaging (CTMRI). We measured the MNCSA and MNT at the level of the hook of hamate on CTMRI. The MNCSA was measured on the transverse angled sections through the whole area. The MNT was measured based on the most compressed MNT. Results: The mean MNCSA was 9.01 ± 1.94 ㎟ in the control group and 6.58 ± 1.75 ㎟ in the CTS group. The mean MNT was 2.18 ± 0.39 mm in the control group and 1.43 ± 0.28 mm in the CTS group. Receiver operating characteristics curve analysis demonstrated that the optimal cut-off value for the MNCSA was 7.72 ㎟, with 75.0% sensitivity, 75.0% specificity, and an area under the curve (AUC) of 0.82 (95% confidence interval [CI], 0.69-0.95). The best cut off-threshold of the MNT was 1.76 mm, with 85% sensitivity, 85% specificity, and an AUC of 0.94 (95% CI, 0.87-1.00). Conclusions: Even though both MNCSA and MNT were significantly associated with CTS, MNT was identified as a more suitable measurement parameter.

Design of a Warning System Using Radio Beacon Signal to Avoid Hazardous Area in VFR Mode (무선전파막을 이용한 시계 비행항공기의 비행위험지역 회피용 경보장치의 설계)

  • Kim, Yeon-Myung;Park, Dong-Young;Yun, Tae-Won;Hwang, Byong-Won
    • Journal of Advanced Navigation Technology
    • /
    • v.8 no.2
    • /
    • pp.98-104
    • /
    • 2004
  • When a straight-in landing from an instrument approach using ILS or VOR/DME is not possible or desirable because of topographical reason or bad weather, a circling approach maneuver is initiated by the pilot to align the aircraft with a runway for landing. Visual contact with the runway is necessary while conducting a circle to land maneuver. This research is to develop a new warning system based on a convention marker system which alerts pilots to watch out for exceeding the circling approach area. The airborne system also uses the same receiver unit without any new installations. The objective of this research is to design and develop a Yagi antenna in a special form. The research includes computer simulations to determine the size of antenna radiation pattern and to compute an expected flight path in case of alarm to validate effectiveness of the system.

  • PDF

Dental students' ability to detect maxillary sinus abnormalities: A comparison between panoramic radiography and cone-beam computed tomography

  • Rosado, Lucas de Paula Lopes;Barbosa, Izabele Sales;de Aquino, Sibele Nascimento;Junqueira, Rafael Binato;Verner, Francielle Silvestre
    • Imaging Science in Dentistry
    • /
    • v.49 no.3
    • /
    • pp.191-199
    • /
    • 2019
  • Purpose: To compare the diagnostic ability of undergraduate dental students to detect maxillary sinus abnormalities in panoramic radiographs(PR) and cone-beam computed tomography (CBCT). Materials and Methods: This was a retrospective study based on the evaluation of PR and CBCT images. A pilot study was conducted to determine the number of students eligible to participate in the study. The images were evaluated by 2 students, and 280 maxillary sinuses were assessed using the following categories: normal, mucosal thickening, sinus polyp, antral pseudocyst, nonspecific opacification, periostitis, antrolith, and antrolith associated with mucosal thickening. The reference standard was established by the consensus of 2 oral radiologists based on the CBCT images. The kappa test, receiver operating characteristic curves, and 1-way analysis of variance with the Tukey-Kramer post-hoc test were employed. Results: Intraobserver and interobserver reliability showed agreement ranging from substantial (0.809) to almost perfect (0.922). The agreement between the students' evaluations and the reference standard was reasonable (0.258) for PR and substantial(0.692) for CBCT. Comparisons of values of sensitivity, specificity, and accuracy showed that CBCT was significantly better(P<0.05). Conclusion: CBCT was better than PR for the detection of maxillary sinus abnormalities by dental students. However, CBCT should only be requested after a careful analysis of PR by students and more experienced professionals.

Analysis of underwater acoustic communication channel environment in Kyungcheon Lake (경천호에서의 수중 음향 통신 채널 환경 분석)

  • Kim, Yong-Cheol;An, Jong-Min;Lee, Ho-Jun;Lee, Sang-Kug;Chun, JaeHak
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.1
    • /
    • pp.1-8
    • /
    • 2019
  • This paper estimated communication parameters according to underwater channel environment of lake for underwater acoustic communication. This paper calculated coherence time and coherence bandwidth through two experiments in actual lake environments. In both experiments, the chirp signal for channel estimation and the BPSK (Binary Phase Shift Keying) signal for calculating the bit error rate were transmitted. In each experiment, the distance between transmitter and receiver was 300 m to 400 m, and 500 m to 600 m. The coherence times calculated in experiment 1 and experiment 2 are 175 msec and 340 msec, and the coherence bandwidths are 10 Hz and 5.71 Hz, respectively. It is confirmed that the experimental results are more appropriate because the synchronization and the bit error rate performance are better only when the length of the synchronization signal and the interval of the pilot signal in the frame are shorter than the coherence time.

Implementation of a drone using the PID control of an 8-bit microcontroller (8bit 마이크로컨트롤러의 PID제어를 이용한 드론 구현)

  • Lee, Donghee;Moon, Sangook
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.6 no.9
    • /
    • pp.81-90
    • /
    • 2016
  • Recently drones have become popular enough to be one of the hobby. The drone refers to an unmanned aerial vehicle which can fly and be steered by a radio wave without a pilot and it has a airplane or helicopter shape. The drone was first started to be used from military purpose, but its usage has been expanded to the private such as construction site, crop-dusting, field discovery, freight shipping and drones to prevent cheating. However the drone that we can see often in the market is expansive, hard to be repaired when it broken down and has a discomfort of the short flight time. In this paper, to solve an uncomfortable talk on the cheap 8-bits microcontrollers ATmega128 Using drone for implementation. Axes gyroscope and accelerometers mcu between posture an attitude control, communications through drone control, pid. Receiver input them into transmitter signals of movements to control drone c the programming was implemented in on the basis of language. drone using ATmega128 microcontroller is possible hovering, By utilizing a pin that are not required for control it can be used as a drone for a variety of uses.

A Multicenter Pilot Study of Biliary Atresia Screening Using Digital Stool Color Imaging

  • Kannamon Waitayagitgumjon;Wannisa Poocharoen;Suchin Trirongjitmoah;Kriengsak Treeprapin;Arada Suttiwongsing;Thetiya Wirifai;Chira Trirongchitmoh;Pitiporn Tangkabuanbutr
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.27 no.3
    • /
    • pp.168-175
    • /
    • 2024
  • Purpose: The presence of alcoholic stool in biliary atresia (BA) patients is the basis of a stool color card (SCC), a screening tool that has led to more patients receiving Kasai portoenterostomy earlier. This study aimed to evaluate the color image processing of stool images captured using smartphones. We propose that measuring digital color parameters is a more objective method for identifying BA stools and may improve the sensitivity of BA screening. Methods: A prospective study was conducted in five hospitals in Thailand between October 1, 2020, and December 31, 2021. Stools from infants presenting with jaundice, acholic stool, or dark-colored urine were photographed. Digital image color analysis was performed, and software was developed based on the color on the original SCC. Sensitivity and specificity for predicting BA stools were compared between the SCC and the software. Results: Of 33 infants eligible for data collection, 19 were diagnosed with BA. Saturation and blue were two potential digital color parameters used to differentiate BA stools. The receiver operating characteristic curve was used to determine the optimum cutoff point of both values, and when saturation ≤56 or blue ≥61 was set as a threshold for detecting BA stool, high accuracy was achieved at 81.8% and 78.8%, respectively. Conclusion: Digital image processing is a promising technology. With appropriate cutoff values of saturation in hue, saturation, value and blue in red, green, blue color models, BA stools can be identified, and equivocal-colored stools of non-BA patients can be differentiated with acceptable accuracy in infants presenting with jaundice.