• 제목/요약/키워드: Pig bones

검색결과 14건 처리시간 0.017초

이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰 (Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid)

  • 정의성;성기웅;임형규;이장우;김동욱;이정현;김명남;조진호
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

정형보철용 금속을 이용한 자기공명영상왜곡의 정량적 평가 (Quantitative evaluation of MRI distortion using orthopedic prosthetic metal)

  • 김형균
    • 한국방사선학회논문지
    • /
    • 제7권1호
    • /
    • pp.57-62
    • /
    • 2013
  • 자기공명영상은 많은 장점에도 불구하고 체내에 정형보철이 있는 경우 자화율 차이로 영상왜곡이 발생한다. 스테인리스와 티타늄 시험편을 $65{\times}15{\times}2mm$로 동일하게 제작하여 phantom과 돼지고기에 부착 한 후 자기공명영상과의 관계를 알아보았다. phantom 영상을 통해 영상왜곡의 길이와 돼지 뼈를 통한 신호강도의 변화, 피하조직의 지방억제 정도를 정량적으로 평가 하였다. 스테인리스는 티타늄에 비해 길이 방향으로 4.4배, 높이 방향으로 2.8배 영상왜곡이 크며, 신호강도는 58.5%로 상대적으로 낮았다. 피하조직 지방억제는 Normal의 56.2%에 비해 스테인리스는 16.04%, 티타늄은 54.53%로 나타났다. 실험 결과 자기공명영상의 영상학적 진단가치는 스테인리스 보다 티타늄 금속이 부착 된 경우 더 우수한 것을 알 수 있었다.

Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

  • Yoon, Hong-Gi;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.10-15
    • /
    • 2011
  • PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.

엽삭젓 제조중의 미생물 및 화학성분의 변화 (Changes of Microbial and Chemical Components in Salt-fermented Youbsak during the Fermentation)

  • 양호철;정희종
    • 한국식품과학회지
    • /
    • 제27권2호
    • /
    • pp.185-192
    • /
    • 1995
  • 함평군 손불면의 특산물인 엽삭젓을 염농도 18%와 22%로 각각 엽삭젓을 제조하여 발효가 진행되는 동안 발효와 관련된 미생물과 여러가지 화학성분의 변화를 측정한 결과 발효 초기에 지질과 단백질의 감소와 총균수의 증가가 있었고 총산도의 증가는 어느정도 pH와 반비례적인 경향을 보였고, 아미노태질소와 지질의 산가는 급증한 후 큰 변화를 보이지 않았다. 선도의 척도라 할 수 있는 휘발성염기질소는 뼈국물을 넣어줌으로서 그 증가가 억제됨을 보이지만 전체적으로 볼때 발효 기간중 꾸준히 증가하였으며 염도 22% 엽삭젓보다는 염도 18% 엽삭젓이 훨씬 높은 수치를 보였다. 지방산 조성은 palmitic acid($C_{16:0}$)가 20% 정도 함유되어 가장 많았고, palmitoleic acid($C_{16:1}$), eicosapentaenoic acid($C_{20:5}$), oleic acid($C_{18:1}$), myristic acid($C_{14:0}$)순으로 함유되어 이들이 전체 지방산의 77.3%를 차지하였으며 EPA와 DHA도 약 20%정도 함유되어 있었으며 발효 기간중 큰 변화가 없었으며 염도에 따른 차이도 없었다. 총 유리아미노산도 휘발성 염기질소와 마찬가지로 계속 증가하지만 뼈국물을 넣고 젓국물 달여 붓기를 하므로서 상당히 그 증가의 지연이 이루어짐을 알 수 있었으며 유리아미노산 조성은 원료육의 경우 aspartic acid, threonine, histidine이 주류를 이루었으나 숙성된 염도 18% 엽삭젓의 경우는 leucine, tyrosine, glutamic acid, valine, isoleucine이, 염도 22% 엽삭젓의 경우는 alanine, glutamic acid, leucine, methionine이 주류를 이루었다. 이상의 결과를 비교해 볼때 엽삭젓에는 고도불포화지방산 특히 EPA가 많이 함유되어 있으며 염도 18%와 22%의 엽삭젓의 염도간에 큰 차이는 없었으나 VBN등의 변화에 있어서 엽삭젓 제조의 염도로는 18%에 비하여 22%가 더 적합한 것으로 생각되었다.

  • PDF