• Title/Summary/Keyword: Pick-Up Coil

Search Result 49, Processing Time 0.026 seconds

Design and Vibration Reduction Method of Sub-Resonance in Optical Pick-Up Actuator Using the Fine Pattern Coil (FP 코일형 광픽업 액츄에이터의 설계 및 부공진의 진동저감 대책)

  • 정호섭;오관영;유익형
    • Journal of KSNVE
    • /
    • v.8 no.4
    • /
    • pp.643-653
    • /
    • 1998
  • The sub-resonance modes can be easily excited by the assembling tolerance in the asymmetric type optical pick-up actuators, compared with the symmetric type. In this paper, we propose the novel method for reducing the vibration due to the sub-resonance modes whose amplitude can be decreased by adding the damper and increasing the flexibility of holder PCB. Using the finite element method, the change of mode shapes is investigated as the shape of holder PCB is modified. Experimental results support that the propopsed method reduces remarkably the vibration of sub-resonance modes of the optical pick-up actuator.

  • PDF

A Study on the Implementation of the 2-Dimension Magnetic Fluxgate Sensor (2차원 Magnetic Fluxgate센서의 구현에 관한 연구)

  • Park, Yong-Woo;Kim, Nam-Ho;Ryu, Ji-Goo
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.67-76
    • /
    • 2002
  • We have presented a 2-dimensional fluxgate sensor with ferrite core, excitation, and pick-up coil. This fluxgate sensor system consists of a sensing element, driving circuits for excitation coil and signal processing for detecting second harmonic frequency component which is proportional to the DC magnetic to be measured. The sensor core is excited by a square waveform of voltage through the excitation coil of 80 turns. The second harmonic output of pick-up coil(x and y axis: 100 turns) is measured by FFT spectrum analyzer. This result is compared with output of PSD(phase sensitive detector) unit for detecting the second harmonic component. The measured maximum sensitivity is about 1580 V/T at driving frequency of 1.5 kHz and excitation current of 2 App. The nonlinearity of this system is measured about 2.3%(PSD) and about 1%(second harmonics of the pick-up). The angle error of the system is ${\pm}2$ %/FS.

The Design of a I/O Circuits for Driving and Monitoring of the Diesel Generator for Emergency (비상용 디젤 발전기 구동 및 모니터링을 위한 입출력 회로 설계)

  • Joo, Jae-Hun;Kim, Jin-Ae;Choi, Jung-Keyng
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.8
    • /
    • pp.1491-1496
    • /
    • 2009
  • This paper presents an digital based input/output interface circuit for controlling and monitoring the Diesel Engine Generator for emergency. In order to monitor and control of the Emergency Diesel Engine Generator, controlling and monitoring circuits need 5 analog input channels, 2 pick-up coil measuring circuits, 10 digital input channels containing Broken Wire Detect function, and 7 relay control signal output channels. This system performs signal processing of input signal taking advantage of simple filter circuit, photo-coupler and comparator circuit at analog input parts, and output signals for main relay is designed acting by double control, so it prevents malfunction completely. And it improves accuracy of speed input signal by applying digital circuit that processes rick-up coil signal.

Implementation of a Fluxgate Sensor using Ferrite Ring Core (페라이트 링 코어를 사용한 fluxgate 센서의 구현)

  • Park, Yong-Woo;Kim, Ki-Uk;Kim, Nam-Ho;Ryu, Ji-Goo
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.6
    • /
    • pp.427-433
    • /
    • 1999
  • In this paper, we have presented an one-axis fluxgate magnetic sensor with ferrite core, excitation, and pick-up coil. This magnetometer is consist of a sensing element, driving circuits for excitation coil and signal processing for detecting second harmonic frequency component which is proportional to the DC magnetic to be measured. The sensor core is excited by a square waveform of voltage through 82 turns of the excitation coil. The second harmonic output of pick-up coil(150 turns) is measured by a FFT spectrum analyzer. This result is compared to output of PSD(phase sensitive detector) unit for detecting a second harmonic component. The measured sensitivity is about 50 V/T at driving frequency of 2 kHz. The nonlinearity of fluxgate magnetic sensor is calculated about 2.0%.

  • PDF

Detection of tension force reduction in a post-tensioning tendon using pulsed-eddy-current measurement

  • Kim, Ji-Min;Lee, Jun;Sohn, Hoon
    • Structural Engineering and Mechanics
    • /
    • v.65 no.2
    • /
    • pp.129-139
    • /
    • 2018
  • Post-tensioning (PT) tendons are commonly used for the assembly of modularized concrete members, and tension is applied to the tendons during construction to facilitate the integrated behavior of the members. However, the tension in a PT tendon decreases over time due to steel corrosion and concrete creep, and consequently, the stress on the anchor head that secures the PT tendon also diminishes. This study proposes an automatic detection system to identify tension reduction in a PT tendon using pulsed-eddy-current (PEC) measurement. An eddy-current sensor is installed on the surface of the steel anchor head. The sensor creates a pulsed excitation to the driving coil and measures the resulting PEC response using the pick-up coil. The basic premise is that the tension reduction of a PT tendon results in stress reduction on the anchor head surface and a change in the PEC intensity measured by the pick-up coil. Thus, PEC measurement is used to detect the reduction of the anchor head stress and consequently the reduction of the PT tendon force below a certain threshold value. The advantages of the proposed PEC-based tension-reduction-detection (PTRD) system are (1) a low-cost (< $ 30), low-power (< 2 Watts) sensor, (2) a short inspection time (< 10 seconds), (3) high reliability and (4) the potential for embedded sensing. A 3.3 m long full-scale monostrand PT tendon was used to evaluate the performance of the proposed PTRD system. The PT tendon was tensioned to 180 kN using a custom universal tensile machine, and the tension was decreased to 0 kN at 20 kN intervals. At each tension, the PEC responses were measured, and tension reduction was successfully detected.

KT-1 토카막의 전자석 코일에 의한 유도가열탈리

  • 정승호;박선기
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.34-34
    • /
    • 1999
  • 토카막(Tokamak)에서는 플라즈마(plasma)로 불순불(impurity)의 유입을 방지하기 위해 고진공을 유지해야 하며 이를 위해 가열탈리(backing), 방전세정(discharge codanning) 등 wall conditioning이 기본적으로 요구된다. KT-1 토카막은 실험실 이전에 따른 해체로 인해 진공용기(vacuum vessel) 가 대기압 하에 수개월 동안 노출되어 있었기 때문에 재조립 후 가열 탈 리가 필수적이나 진공용기의 외부에 saddle loop coil을 비롯해 Rogowski, diamagnetic coil, poloidal field coil 등 많은 magnetic pick up coil 들이 설치되어 있어 열선 등 일반적인 방법으로 가열 탈 리가 어려운 상황이다. 따라서 KT-1 토카막에서는 전자석 코일에 상전원을 부가하였을 때 진공용기에 발생하는 유도가열 (inductive heatin)을 이용해 가열 탈리를 시도하였다. 유도 가열 탈리(inductive backing)는 토로이달 자장 코일(toroidal field coil)과 가열 저장 모일(ohmic heating coil)을 각각 이용하여 코일의 온도가 6$0^{\circ}C$ 이하가 유지되는 코일 전류 범위내에서 수행하였으며 먼저 이 둥 경우에 있어서 진공용기의 온도분포를 비교하엿다. 그리고 가열 탈리 기간 및 그 전, 후의 진공압력과 잔류기체 분압을 측정, 분석하였다. 유도가열에 의한 방법으로 KT-1 토카막에서 얻은 탈리온도는 12$0^{\circ}C$정도로 비교적 낮았으나 탈리 시간을 연장하여 탈리효과를 어느 정도 보상할 수 있으며 일반적인 가열 탈리가 여려운 경우 유도 가열 탈 리가 채택될 수 있는 또 하나의 방법이라 볼 수 있다.

  • PDF

Voltage disturbance detection method for HTS tape using electromagnetically coupled coils

  • Song, Seunghyun;Lee, Jiho;Lee, Woo Seung;Jin, Hongwoo;Hwang, Young Jin;Ko, Tae Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.1
    • /
    • pp.23-26
    • /
    • 2014
  • This paper represents the detection method of voltage disturbance for high temperature superconducting (HTS) tape using electromagnetically coupled coils. In order to detect the voltage as the superconductor transits from the superconducting state to the normal conduction state, voltage taps are widely used to get the voltage signal. And voltage taps are connected to data acquisition device via signal wires. However this new suggested method can detect the superconducting transition voltage without signal wires between voltage taps and data acquisition device by using electromagnetically coupled coils. This system consists of two electromagnetically coupled coils, the first coil to detect and transmit the voltage of HTS tape and the second coil to pick up the transmitted voltage from the first coil. By using this new suggested method, we can build the 'separated voltage-detection system'. HTS tape and first coil are located under liquid nitrogen vessel and the second coil is located under room temperature condition. In this paper, experiments are performed to verify the feasibility of the proposed method. As the result of the experiment, the separated voltage-detection system using electromagnetically coupled coils can successfully observe superconducting-normal transition of HTS tapes.

Design of Tracking Actuator for NFR(Near-Field Recording) System (근접장 기록 장치의 트랙 추적 구동기의 설계)

  • Kim, Ki-Hyun;Lee, Moon-Gu;Jung, Hwe-On;Jung, Jae-Hwa;Gweon, Dae-Gab
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.748-753
    • /
    • 2000
  • Nowadays, many studies and researches in data storage have been carried out and storage capacity is increased. But the limitation of storage capacity is happened for several problems. One of them is spot & pit size in optical and magnetic data storage and another is the resolution of actuators. The problems in spot & pit size is covered by new data storage methods- for example, NFR{Near-Field Recoding) system. But the resolution limit of an actuator doesn't follow up the development of spot & pit size. Because of them, we should improve a resolution of an actuator. Especially, in this paper an actuator is studied and designed for NFR(in using SIL(Solid Immersion Lens) system. It is a dual stage actuator, which consists of a Fine actuator and a Coarse actuator, and should desire 100nm accuracy. But, our actuator system only includes tracking mechanism execpt focusing mechanism which is controlled by slider mechanism used in HDD. Its actuating force generation method is VCM(Voice Coil Motor). The Fine actuator is composed of 4-leaf springs and a bobbin wrapped by coil. The Coarse actuator has Coils and 3-Roller bearings.

  • PDF

Optimal Design of Micro Actuator Plate Spring Considering Vibration Characteristic (진동 특성을 고려한 마이크로 엑추에이터 판 스프링의 최적설계)

  • 이종진;이호철;유정훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.220-225
    • /
    • 2003
  • Recent issue of optical actuator is applying to mobile device. It leads actuator to become smaller than conventional type. This paper proposes the design of micro actuator plate spring and analysis of its vibration characteristic. Considering natural frequency of spindle motor, 1st and 2nd eigenfrequency of micro actuator must avoid its natural frequency. First, magnetic circuit is designed by using fine pattern coil and magnetic force is acquired by simulation program. Then, concept design is achieved by topology optimization. From concept design, micro actuator plate spring is embodied through DOE(design of experiment). Finally, considering vibration characteristic simultaneously, optimal plate spring design is determined by RSM(response surface method).

  • PDF