• Title/Summary/Keyword: Physiological parameters

Search Result 680, Processing Time 0.03 seconds

Measurement and Analysis of Rodent Biological Signals using Telemetry System (원격측정장치를 이용한 설치류의 생체신호 측정 및 분석)

  • Kim, Chang-Hwan;Hur, Gyeong-Haeng
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1159-1165
    • /
    • 2011
  • Telemetry techniques of rats have been used for assessing safety pharmacology of drugs and chemicals. Biological signals including blood pressure and heart rate measured under anesthesia were significantly different from those obtained under normal conditions. The stress of restraint in awake animals can also affect the accuracy of physiological evaluation. This paper details the surgery required to allow key cardiovascular parameters to be determined. The telemetric measurement of cardiovascular parameters such as blood pressure, heart rate, electrocardiograph(ECG) established. We carried out the continuous monitoring of cardiovascular parameters using the telemetry system in F344 rats. During the measurement, no significant changes were observed in the heart rate and blood pressure. ECG signals and body temperature were also constant during the measurement of biological signals. With the results of this study, we conclude that this telemetry system can be applied usefully for the assesment of biological parameters in the rats.

Review on the Changes of Liver Function Parameters after Administration of Herbal Medicine (간기능 정상자 또는 불특정 환자를 대상으로 한 한약 복용 후 간기능 지표 변화에 대한 문헌적 고찰)

  • Han, Deok-Jin;Park, Sang-Moo;Kang, Baek-Gyu;Lee, Jung-Wook;Na, Ran-Hee;Bang, Chang-Ho;Jang, Seok-O;Kim, Kang-San
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1390-1396
    • /
    • 2008
  • The aim of this study is to analyze literatures researching changes of liver function parameters after administration of herbal medicine and the safety of herbal medicine on hepato-biliary system. Eight Korean databases were searched for researches on the safety of oriental herbal medicine. According to inclusion criteria, nineteen studies were selected and analyzed. As a result, seventy outcomes in five parameters(aspartate transaminase, alanine transaminase, gamma(${\gamma}$)-glutamyl transferase, alkaline Phosphatase, total bilirubin) were obtained. After administration, parameters decreased or sustained in fifty seven outcomes. In thirteen outcomes, parameters slightly increased. In two outcomes, parameters increased but not severely. The change of liver function parameters after administration of herbal medicine is expected to be harmless. But it requires additional large scale studies and modification in method to corroborate the safety of herbal medicine.

Computer Simulation of Glucose-insulin Kinetics During Intravenous Glucose Tolerance Test

  • Min, B.G;Woo, E.J.
    • Journal of Biomedical Engineering Research
    • /
    • v.4 no.1
    • /
    • pp.9-14
    • /
    • 1983
  • A new quantitative method was developed for separation of three interactive physiological factors (hepatic glucose balance, peripheral tissue's insulin resistivity, and insulin secretion rate) influencing glucose intolerance in diabetic mellitus using an equivalent circuit model and the intravenous glucose tolerance test (IVGTT) in six dogs and twenty two humans. The results show that the estimated model parameters of the above three factors are useful for evaluating different glucose-insulin kinetics in normal and diabetic subjects.

  • PDF

Hemodynamic simulation of the aging effect on the cardiovascular system (심혈관계의 노화현상에 대한 혈류역학적 시뮬레이션)

  • Byun Su-Young;Sohn Jeong L.;Shim Eun-Bo;Ro Sung Tack
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.713-716
    • /
    • 2002
  • Aging effect on the cardiovascular circulation is simulated by lumped parameter model. Aging phenomena can be hemodynamically explained as (1) the increase of flow resistance induced by remodeling of artery vessels and increased viscosity of blood and (2) the reduction of the vessel capacitance caused by arteriosclerosis. Appropriate physiological parameters are evaluated from the clinical data of adults and old men. Simulation results well explain the hypertension with aging of cardiovascular system.

  • PDF

RECEMT DEVELOPMENTS IN REAL-TIME MRI

  • Riederer, Stephen J.
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.67-72
    • /
    • 2002
  • Real-time techniques are motivated by a number of factors including the potential for direct acquisition of diagnostic quality images, facilitation of patient-specific imaging parameters, and reduced examination time. Real-time MRI includes not only a rapid pulse sequence but also high speed image reconstruction and easy interactivity. The frame rate of the real-time technique used should be matched to the physiological timeframes under study. Principal applications thusfar have been in localization, fluoroscopic triggering, guidance of other processes, and potentially in the generation of diagnostic images of moving structures.

  • PDF

Pharmacokinetics of Nalidixic Acid in $CCl_4-Toxicated$ Rabbit (병태(病態) 토끼에서의 Nalidixic Acid의 약물동태학적(藥物動態學的) 연구(硏究))

  • Lee, Min-Hwa
    • Journal of Pharmaceutical Investigation
    • /
    • v.13 no.2
    • /
    • pp.51-58
    • /
    • 1983
  • In order to elucidate the effects of Panax Ginseng on the pharmacokinetic parameters of nalidixic acid in a patho-physiological changes, the kinetics of the disappearance of the drug from the blood, appearance in the bile and urinary excretion were studied in $CCl_4-toxicated$ rabbits. The pharmacokinetics of the drug nalidixic acid in rabbits were modeled by a two compartment. Total saponin, water extract from Panax Ginseng, significantly decreased biliary and urinary excretion of nalidixic acid.

  • PDF

A Comparison of Parameters of Acoustic Vowel Space in Patients with Parkinson's Disease (파킨슨병 환자의 음향 모음 공간 파라미터 비교)

  • Kang, Young-Ae;Yoon, Kyu-Chul;Lee, Hak-Seung;Seong, Cheol-Jae
    • Phonetics and Speech Sciences
    • /
    • v.2 no.4
    • /
    • pp.185-192
    • /
    • 2010
  • The acoustic vowel space has been used as an acoustic parameter in dysarthric speech. The aim of this work was to examine mathematical formulae for acoustic vowel space and to apply these to Korean speakers with idiopathic Parkinson's disease(IPD). Five acoustic parameters were chosen from earlier works and one new parameter was proposed, the pentagonal vowel space. The six parameters included triangular vowel space (3 area), irregular quadrilateral vowel space (4 area), irregular pentagonal vowel space (5 area), vowel articulatory index (VAI), formant centralization ratio (FCR) and F2i/F1u ratio (F2 ratio). An experimental group of 32 IPD patients(male:female=16:16) and a control group of twenty healthy people (male:female=8:12) participated in the study and repeated vowels (/a-i-u-e-o/) three times. A correlation analysis was performed among the six parameters, 2-way ANOVA was done with gender and groups as independent factors, and an independent sample t-test was conducted between the male and the female group as post hoc comparison. All parameters were highly correlated with each other and only the FCR showed a high negative correlation with the others. The results of ANOVA showed a significant difference in F2 ratio, 3 area, 4 area and 5 area between gender and in 4 area and 5 area between groups. For the male members of the two groups, significant statistical differences were found in all parameters whereas no such differences were found for the female members. These findings indicated that the vowel space of the female group was wider than the vowel space of the male group. These differences may have been caused by gender-specific speech styles rather than by patho-physiological mechanisms. We also claim that the pentagonal vowel space is better than the other vowel spaces at representing the disordered speech in natural speech situations.

  • PDF

Consumption and Conversion Efficiency of Food in New Elite Bivoltine Hybrid Silkworm, Bombyx mori L. under Restricted Feeding Levels

  • Mathur, Vinod B.;Rahmathulla, V.K.;Bhaskar, O.Vijaya
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.5 no.2
    • /
    • pp.213-216
    • /
    • 2002
  • Food consumption and conversion efficiency of new bivoltine hybrids (CSR2$\times$CSR4 and CSR2$\times$CSR5) were studied under restricted feeding levels (10, 20 and 30% less quantity of mulberry leaves). The data were compared with a control fed with standard quantum of feed as per the recommendation. The nutritional indices parameters i. e. ingests, digesta, approximate digestibility (%) and reference ratio were recorded higher in control batches compared to less feed batches while nutritional efficiency parameters i. e., ECI and ECD to cocoon and shell were recorded significantly higher in restricted feeding level batches. This increase is attributed due to the physiological adaptation under nutritional stress condition.

Cyclic Voltammetric Investigation of Interactions between Bisnitroaromatic Compounds and ds.DNA

  • Janjua, Naveed Kausar;Akhter, Zareen;Jabeen, Fariya;Iftikhar, Bushra
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.2
    • /
    • pp.153-159
    • /
    • 2014
  • Herein, the cyclic voltammetric (CV) investigations of structurally similar bisnitrocompounds (N3, N4, N5, N6, having different-$CH_2$-spacer length) is presented. CV study offered interesting interactional possibilities of bisnitrocompounds with chicken blood ds.DNA at physiological pH 4.7 and human body temperature, 310 K. The results indicated strong interaction by these symmetric molecules with ds.DNA and strength of binding is found to depend on length of $CH_2$ spacer group in their molecular structure. Thermodynamics derived from electrochemical binding parameters also favored the irreversible interactions. Moreover, threading intercalation mode of binding is suggested based on thermodynamic and kinetic binding parameters extracted from CV studies.

Realtime Measurement of Impedance Locus using Impedance Spectroscopy: How Many and How Low Frequencies Are Required \ulcorner

  • T., Fukumoto;G. M., Eom;S., Ohba;N., Hoshimiya
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1194-1197
    • /
    • 2004
  • High temporal-resolution and accurate measurement of skin impedance locus provides useful data for the identification of the physiological/psychological changes and also the identification of acupuncture point. An impedance spectroscopy method using digitally constructed current waveform consisting of many frequency components (multiples of 1Hz) was reported3. The time resolution of the method depends on the lowest frequency used in the waveform construction, and therefore, the measurement would be faster if the lowest frequency is the higher. However, it was not clear that how many and how low frequencies must be used for the estimation of the skin impedance parameters from which the impedance locus can be drawn. This study shows the relationship between the estimation error of the impedance parameters and the frequency coverage of the spectroscopy. The results of this study are expected to serve as the reference of the frequency selection in the impedance spectroscopy.

  • PDF