• 제목/요약/키워드: Physiological noise

검색결과 91건 처리시간 0.021초

고령자의 손등피부 탄성 특성을 활용한 체질분류 방법 연구 (Study of Sasang Constitution Classification Method Based on Elasticity Coefficient of Hand Doral Skin of Elderly People)

  • 강남식;이재철;구본초;김종열;김영민
    • 동의생리병리학회지
    • /
    • 제25권6호
    • /
    • pp.1050-1055
    • /
    • 2011
  • This paper presents a novel diagnostic method to determine Sasang Consitution (SC) by elasticity coefficient of hand dorsal skin of elderly people. For this purpose, we carried out a clinical test, in which Our SC diagnostic tool and one Oriental medical doctor with SC medicine expertise participated to categorize 458 healthy subjects into four constitutions. After excluding heavy-noise, we extracted 295 subjects' elasticity coefficient feature data and statistically analyzed their SC relevance with ANOVA test. It resulted in that, Taeum-in has high elasticity coefficient compared to Soeum-in in a significance level of 0.05. There are no differences of elasticity coefficient in genders. This result is supported by the theory of Longevity and Life Preservation in Eastern Medicine(Donguisusebowon, 동의수세보원) which suggested that Taeum-in's flesh is solid and Soeum-in's one is tender. This is the first work which reports the relatedness of skin elasticity coefficient and SC by an objective clinical test.

조선소 도장작업자의 작업환경 및 작업복 착의실태 분석 (The Analysis on the Work Environment and Working Clothes Wearing Conditions of Shipyard Painters)

  • 배현숙;박혜원;박진아
    • 한국의류학회지
    • /
    • 제34권3호
    • /
    • pp.518-528
    • /
    • 2010
  • This study analyzes the work environment and the work clothes wearing conditions of shipyard painters. In addition to this, three types of experimental painting work clothes were evaluated by painters in terms of the material performance and wearing functions. The findings on the harmful painting work environmental factors were organic solvents, noise, heavy dust, high temperatures, and noxious fumes. The body parts damaged during painting operations were the skin, arms, whole body, and face. In general, the satisfaction with the wearing performance of work clothes for painting was low especially in regards to sweat absorbency, sweat permeability, body protection, covering, and the work motion suitability. The satisfaction with the wearing sense of painting working clothes (regardless of the type of material) was high in the order of movement comfort> sensual comfort> physiological comfort. The satisfaction in overall comfort according to the types of material was high in the order of nylon> SMS nonwoven fabric> SF nonwoven fabric.

산업현장의 작업환경 및 공정에 따른 작업복 착의실태 -기계.자동차.조선업을 중심으로- (The Wearing Conditions of Working Clothes According to the Working Environment and Working Processes at Industry Sites -With Reference to Machinery, Automobiles, and the Shipbuilding Industry-)

  • 배현숙;박혜원;박진아;김지관
    • 한국의류학회지
    • /
    • 제34권8호
    • /
    • pp.1378-1391
    • /
    • 2010
  • This study examines the wearing conditions of working clothes according to the working environment and working processes at machinery, automobile, shipbuilding industry sites. It also investigates the relationship between the wearing sense of working clothes and the overall comfort according to work processes. The hazardous working environment was high in the order of the shipbuilding industry, machinery, and automobiles. The findings on the harmful overall work environmental factors were the noise, heavy dust, and noxious fumes, respectively. In general, the satisfaction with the wearing performance of working clothes was low especially with regard to sweat absorbency, sweat permeability, body protection and covering, and the work motion suitability. In respect of the correlation between the overall comfort and the wearing sense of working clothes, the satisfaction was decreased in the order of movement comfort, sensual comfort, and physiological comfort.

다중 생체 신호를 이용한 심장 자기공명영상 스마트 트리거 시스템 (Multi-biological Signal-based Smart Trigger System for Cardiac MRI)

  • 양영중;박진호;홍혜진;안창범
    • 전기학회논문지
    • /
    • 제63권7호
    • /
    • pp.945-949
    • /
    • 2014
  • In cardiac magnetic resonance imaging (CMRI), heart and respiratory motions are one of main obstacles in obtaining diagnostic quality of images. To synchronize CMRI to the physiological motions, ECG and respiratory gatings are commonly used. In this paper multi-biological signal (ECG, respiratory, and SPO2) based smart trigger system is proposed. By using multi-biological signal, the proposed system is robust to the induced noise such as eddy current when gradient pulsing is continuously applied during the examination. Digital conversion of the multi-biological signal makes the system flexible in implementing smart and intelligent algorithm to detect cardiac and respiratory motion and to reject arrhythmia of the heart. The digital data is used for real-time trigger, as well as signal display, and data storage which may be used for retrospective signal processing.

청평호 및 팔당호 어류군집 비교 연구 (The Comparative Study on the Fish Community in Lake Chungpyung and Lake Paldang)

  • 박혜경;이장호;윤석환;최명재
    • 한국물환경학회지
    • /
    • 제29권1호
    • /
    • pp.7-18
    • /
    • 2013
  • We compared the structure of fish community and condition of major fish species in Lake Chungpyung and Lake Paldang, which are relatively shallow, meso-eutrophic, cascading dam reservoirs on the North Han River. Two lakes have wide littoral zone in the lakeside providing similarly good habitat for fishes, whereas fishery and water recreational activities such as motorboating, water skiing are allowed in Lake Chungpyung but are prohibited in Lake Paldang. The average lengths of large size fishes in Lake Chungpyung are shorter than those of same species in Lake Paldang, resulting in the slight distortion of generation distribution of those species in Lake Chungpyung, possibly owing to the active fishery such as fixed shore net fishing, gill net fishing and angling. Meanwhile the condition of fishes represented by the length-weight relationship of fish species did not show the significant differences between two lakes and showed normal condition. To evaluate the impact of physical disturbance such as loud noise and turbulent wave from water recreational activities to fishes precisely, further studies including physiological responses to stress an spawing activity should be needed.

SPECTROSCOPIC ADMITTIVITY IMAGING OF BIOLOGICAL TISSUES: CHALLENGES AND FUTURE DIRECTIONS

  • Zhang, Tingting;Bera, Tushar Kanti;Woo, Eung Je;Seo, Jin Keun
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제18권2호
    • /
    • pp.77-105
    • /
    • 2014
  • Medical imaging techniques have evolved to expand our ability to visualize new contrast information of electrical, optical, and mechanical properties of tissues in the human body using noninvasive measurement methods. In particular, electrical tissue property imaging techniques have received considerable attention for the last few decades since electrical properties of biological tissues and organs change with their physiological functions and pathological states. We can express the electrical tissue properties as the frequency-dependent admittivity, which can be measured in a macroscopic scale by assessing the relation between the time-harmonic electric field and current density. The main issue is to reconstruct spectroscopic admittivity images from 10 Hz to 1 MHz, for example, with reasonably high spatial and temporal resolutions. It requires a solution of a nonlinear inverse problem involving Maxwell's equations. To solve the inverse problem with practical significance, we need deep knowledge on its mathematical formulation of underlying physical phenomena, implementation of image reconstruction algorithms, and practical limitations associated with the measurement sensitivity, specificity, noise, and data acquisition time. This paper discusses a number of issues in electrical tissue property imaging modalities and their future directions.

개포 시민의 숲의 배식에 관한 연구(I) -수목배식 사후평가- (Studies on the Planting of Gaepho Citizen's Woods(I) -The Evaluation of Tree Planting-)

  • 이경재;오충현;류창희;오구균
    • 한국조경학회지
    • /
    • 제18권3호통권39호
    • /
    • pp.71-84
    • /
    • 1990
  • This study was executed to investigate matters connected with planting of Gapho Citizen's Woods(Park), and to offer the data about countermeasure. The study was executed in 1988 and 1989. The contents of the study were the condition of plants, the environmental factors, the states of tree planting and the user's behavior. The result of this study can be summarized as follows. 1. Because of incongruity of soil and regardless of physiological properties of trees, the plants were damaged by their environment. In particular, the stress of soil moisture was serious. 2. The unsuitable planting forms for the park were found out through the park, which was the result of imprudent, additional planting. And so in planting trees additionally, the participation of landscape architect is needed. 3. There is a serious noisy problem from express way. Because when they planted trees, they did not consider about noise. It affected the quality and utilization of the park.

  • PDF

수면시 온열환경에 따른 피부온도 및 신체움직임 분석 (Analysis of Skin Temperature and Body Movements depend on the Thermal Environment during sleep)

  • 임은숙;금종수;이기섭;조관식;배동석;김동규;최광환;최호선
    • 한국감성과학회:학술대회논문집
    • /
    • 한국감성과학회 1999년도 추계학술대회 논문집
    • /
    • pp.3-6
    • /
    • 1999
  • There are numerous studies on relations between sleep and environmental factors such as noise, illumination and thermal conditions. Sleep is affected by the thermal environment. This study describes influence of thermal environment on skin temperature, sleep patterns and body movements using physiological and psychological measurements. The results are as follows: 1) The fluctuations of room temperature during sleep appeared skin temperature variations. The more room temperature is high, the more skin temperature is high in 22$^{\circ}C$, 26$^{\circ}C$, 30$^{\circ}C$. 2) A significant relation between body movement and skin temperature was found within room temperature. Under room temperature conditions of 22$^{\circ}C$, 26$^{\circ}C$, 30$^{\circ}C$, there were significantly higher rates of body movement in the room temperature(30$^{\circ}C$). 3) Uncomfortable after sleep in thermal environment is mostly under high temperature(30$^{\circ}C$), and they are about fatigue due to not enough sleeping. 4) The degree of indoor thermal temperature with sufficient sleeping is in 22.8 ∼ 27.8$^{\circ}C$.

  • PDF

Establishment of a NanoBiT-Based Cytosolic Ca2+ Sensor by Optimizing Calmodulin-Binding Motif and Protein Expression Levels

  • Nguyen, Lan Phuong;Nguyen, Huong Thi;Yong, Hyo Jeong;Reyes-Alcaraz, Arfaxad;Lee, Yoo-Na;Park, Hee-Kyung;Na, Yun Hee;Lee, Cheol Soon;Ham, Byung-Joo;Seong, Jae Young;Hwang, Jong-Ik
    • Molecules and Cells
    • /
    • 제43권11호
    • /
    • pp.909-920
    • /
    • 2020
  • Cytosolic Ca2+ levels ([Ca2+]c) change dynamically in response to inducers, repressors, and physiological conditions, and aberrant [Ca2+]c concentration regulation is associated with cancer, heart failure, and diabetes. Therefore, [Ca2+]c is considered as a good indicator of physiological and pathological cellular responses, and is a crucial biomarker for drug discovery. A genetically encoded calcium indicator (GECI) was recently developed to measure [Ca2+]c in single cells and animal models. GECI have some advantages over chemically synthesized indicators, although they also have some drawbacks such as poor signal-to-noise ratio (SNR), low positive signal, delayed response, artifactual responses due to protein overexpression, and expensive detection equipment. Here, we developed an indicator based on interactions between Ca2+-loaded calmodulin and target proteins, and generated an innovative GECI sensor using split nano-luciferase (Nluc) fragments to detect changes in [Ca2+]c. Stimulation-dependent luciferase activities were optimized by combining large and small subunits of Nluc binary technology (NanoBiT, LgBiT:SmBiT) fusion proteins and regulating the receptor expression levels. We constructed the binary [Ca2+]c sensors using a multicistronic expression system in a single vector linked via the internal ribosome entry site (IRES), and examined the detection efficiencies. Promoter optimization studies indicated that promoter-dependent protein expression levels were crucial to optimize SNR and sensitivity. This novel [Ca2+]c assay has high SNR and sensitivity, is easy to use, suitable for high-throughput assays, and may be useful to detect [Ca2+]c in single cells and animal models.

다중 웨어러블 센서를 활용한 운전자 상태 인식 (Driver's Status Recognition Using Multiple Wearable Sensors)

  • 신의섭;김명국;이창욱;강행봉
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제6권6호
    • /
    • pp.271-280
    • /
    • 2017
  • 본 논문에서는 자동차의 안전운전을 위해서 운전자의 생체정보를 수집하여 운전자의 상태에 따라 운전자에게 적절한 경보를 하거나, 직접 자동자를 제어할 수 있는 기반 시스템을 제시하였다. 기존의 운전자 얼굴정보를 촬영하여 정보를 획득하거나, 운전자의 시트나 스티어링 휠에 센서를 장착하여 생제정보를 획득하는 방식이 부정확하거나 단속적인 정보만을 얻을 수 있는데 비하여, 본 논문에서 제시한 웨어러블 장치는 의료장비 수준의 정확도를 얻을 수 있었으며, 지속적으로 높은 정확도의 생체신호를 얻을 수 있었다. 개발된 웨어러블 장치에는 심박, 피부전도도, 피부온도를 측정할 수 있는 센서를 장착하였으며, 자동차에서 발생되는 각종 잡음을 제거할 수 있는 필터 기술을 적용하였고, 가속도센서와 자이로 센서를 장착하여 측정 오차를 제거하는 기술을 적용하였다. 수집된 생체신호를 바탕으로 운전자의 상태를 판별할 수 있는 기준을 제시하였고, 공인인증기관에 의뢰하여 의료수준 정도의 정확성이 있음을 검증하였다. 실험실 시험과 실차 시험을 통하여 개발된 장치가 운전자의 상태를 측정할 수 있는 장치로 활용될 수 있음을 검증하였다.