• Title/Summary/Keyword: Physiological Sensor

Search Result 127, Processing Time 0.023 seconds

Detection of Fever with Subcutaneously Implanted Thermo-Loggers in Cattle Administered with Lipopolysaccharide

  • Ro, Younghye;Bok, Jin-Duck;Lee, Hun-Jun;Kang, Sang-Kee;Kim, Danil;Lee, Yoonseok
    • Journal of Veterinary Clinics
    • /
    • v.35 no.3
    • /
    • pp.97-99
    • /
    • 2018
  • The aim of this study is to determine whether subcutaneous temperature (ST) was correlated with rectal temperature (RT) in cattle with inducing artificial fever. In order to determine the correlation between their temperatures, the experiment was performed as follow: Among nine Holstein steers, lipopolysaccharide (LPS) was intravenously administered at a dose of $0.5{\mu}g/kg$ of body weight to six Holstein steer, then, 6 ml of saline was administrated to three steers as a control group. After LPS injection, ST was recorded using subcutaneously implanted thermo-logger sensors at 10-min intervals, and RT was measured using a digital thermometer at 0, 1, 2, 3, 4, 8 and 12 h. In steers with LPS injection, RT was highest at 3 to 4 h and recovered to a pre-challenge temperature at 8-22 h. A similar fluctuation was shown in ST except for an unexpected decrease at 1 h, and a positive correlation between RT and ST was observed in LPS-challenged steers (r = 0.497, P = 0.04). This result suggests that ST could be utilized as an index for early detection of infectious diseases or physiological events.

Smart Elderly-care System using Smart-phone (스마트폰을 이용한 고령자용 스마트 간병 시스템)

  • Cho, Myeon-gyun
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.5
    • /
    • pp.129-135
    • /
    • 2017
  • In this paper, we propose a system to monitor the condition of elderly people who are uncomfortable by using smart-phone and biometric sensor at any time and for care-givers to provide with the best medical service anytime and anywhere. The proposed system monitors the status of the elderly through various bionic sensors installed in the hospital ward based on the Arduino system and not only provides the physiological and medical services required by the elderly, but also informs the guardian so that he can cope with the emergency. In conclusion, this paper suggests that a reading light used by elderly people can operate as a home server with a biosensor using Arduino and Android applications (Apps.), and the smart-phone of care-givers is configured as a remote management and a emergency call system. Therefore, this study suggests important ways to improve the satisfaction of medical service for the both elderly people and care-givers of chronic diseases in the future.

Users' Preference and Acceptance of Smart Home Technologies (사용자의 스마트 주거 기술 선호와 수용에 관한 연구)

  • Cho, Myung Eun;Kim, Mi Jeong
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.11
    • /
    • pp.75-84
    • /
    • 2018
  • This study analyzed users' acceptance and intention to use in addition to needs and preferences of smart home technologies, and identified the differences in technology preference and acceptance by different factors. The subjects were residents in the 40s and 60s residing in the Seoul or suburbs of Seoul, and questionnaires were conducted in the 40s while interviews with questionnaires were conducted in the 60s. A total of 105 questionnaires were used as data, and frequency, mean, crossover, independent sample t test, one-way ANOVA and multiple regression analysis were performaed using SPSS23. The results of this study are as follows. First, hypertension, hyperlipidemia and hypercholesterolemia were the most common diseases among respondents and if there was no discomfort, they would like to continue living in the homes of the current residence. Therefore, the direction of smart home development should support the daily living and health care so that residents can live a healthy life for a long time in their living space. Second, the technologies that residents most need were a control technology of residential environments and a monitoring technology of residents' health and physiological changes. The most preferred sensor types are motion sensors and speech recognition while video cameras have a very low preference. Third, technology anxiety was the most significant factor influencing intention to accept smart home technology. The greater the technology anxiety is, the weaker the acceptance of technology. Fourth, when applying smart residential technology in homes, various resident characteristics should be considered. Age and technology intimacy were the most influential variables, and accordingly there were differences in technology preference and acceptance. Therefore, a user-friendly smart home plan should be done in the consideration of the results.

Sleep Monitoring by Contactless in daily life based on Mobile Sensing (모바일 센싱 기반의 일상생활에서 비접촉에 의한 수면 모니터링)

  • Seo, Jung-Hee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.491-498
    • /
    • 2022
  • In our daily life, quality of sleeping is closely related to happiness index. Whether or not people perceive sleep disturbance as a chronic disease, people complain of many difficulties, and in their daily life, they often experience difficulty breathing during sleep. It is very important to automatically recognize breathing-related disorders during a sleep, but it is very difficult in reality. To solve this problem, this paper proposes a mobile-based non-contact sleeping monitoring for health management at home. Respiratory signals during the sleep are collected by using the sound sensor of the smartphone, the characteristics of the signals are extracted, and the frequency, amplitude, respiration rate, and pattern of respiration are analyzed. Although mobile health does not solve all problems, it aims at early detection and continuous management of individual health conditions, and shows the possibility of monitoring physiological data such as respiration during the sleep without additional sensors with a smartphone in the bedroom of an ordinary home.

Design and Implementation of Biometrics Security System Using photoplethysmogram (광용적맥파를 이용한 생체인식 보안시스템의 설계 및 구현)

  • Kim, Hyen-Ki
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.4
    • /
    • pp.53-60
    • /
    • 2010
  • Biometrics are methods of recognizing a person based on the physiological or behavioral characteristics of his of her body. They are highly secure with little risk of loss or falsification by others. This paper has designed and implemented a security system of biometrics by precisely measuring heartbeat signals at two fingertips and using a photoplethysmogram, which is applicable to biometrics. A performance evaluation has led to the following result. The security system of biometrics for personal authentication which has been designed and implemented by this study has achieved a recognition rate of 90.5%. The security system of biometrics suggested here has merits of time saving and easy accessibility. The system is touch-based and collects the necessary biometrics information by simply touching the machine with fingers, so anyone can utilize the system without any difficulty.

Effect of Electrical Muscle Stimulation Training With and Without Superimposed Voluntary Contraction on Rectus Femoris and Vastus Intermedius Thickness and Knee Extension Strength

  • Weon, Young-soo;Kim, Jun-hee;Gwak, Gyeong-tae;Lee, Do-eun;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.140-146
    • /
    • 2022
  • Background: The superimposed technique (ST) involves the application of electrical muscle stimulation (EMS) during voluntary muscle action. The physiological effects attributed to each stimulus may be accumulated by the ST. Although various EMS devices for the quadriceps muscle are being marketed to the general public, there is still a lack of research on whether ST training can provide significant advantages for improving quadriceps muscle strength or thickness compared with EMS alone. Objective: To compare the effects of eight weeks of ST and EMS on the thicknesses of the rectus femoris (RF) and vastus intermedius (VI) muscles and knee extension strength. Methods: Thirty healthy subjects were recruited and randomly assigned to either the ST or EMS groups. The participants underwent ST or EMS training for eight weeks. In all participants, the thicknesses of the RF and VI muscles were measured before and after the 8-week intervention by ultrasonography, and quadriceps muscle strength was measured using the Smart KEMA tension sensor (KOREATECH Co., Ltd.). Results: There were significant differences in the pre- and post-intervention thicknesses of the RF and VI muscles as well as the quadriceps muscle strength in both groups (p < 0.05). RF thickness was significantly greater in the ST group (F = 4.294, p = 0.048), but there was no significant difference in VI thickness (F = 0.234, p = 0.632) or knee extension strength (F = 0.775, p = 0.386). Conclusion: EMS can be used to improve quadriceps muscle strength and RF and VI muscle thickness, and ST can be used to improve RF thickness in the context of athletic training and fitness.

Study on the Method of Diagnosing the Individuals Crop Growth Using by Multi-Spectral Images

  • Dongwon Kwon;Jaekyeong Baek;Wangyu Sang;Sungyul Chang;Jung-Il Cho;Ho-young Ban;HyeokJin Bak
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.108-108
    • /
    • 2022
  • In this study, multispectral images of wheat according to soil water state were collected, compared, and analyzed to measure the physiological response of crops to environmental stress at the individual level. CMS-V multi-spectral camera(Silios Technologies) was used for image acquisition. The camera lens consists of eight spectral bands between 550nm and 830nm. Light Reflective information collected in each band sensor and stored in digital values, and it is converted into a reflectance for calculating the vegetation index and used. According to the camera manual, the NDVI(Normalized Difference vegetation index) value was calculated using 628 nm and 752 nm bands. Image measurement was conducted under natural light conditions, and reflectance standards(Labsphere) were captured with plants for reflectance calculation. The wheat variety used Gosomil, and the wheat grown in the field was transplanted into a pot after heading date and measured. Three treatments were performed so that the soil volumetric water content of the pot was 13~17%, 20~23%, and 25%, and the growth response of wheat according to each treatment was compared using the NDVI value. In the first measurement after port transplantation, the difference in NDVI value according to treatment was not significant, but in the subsequent measurement, the NDVI value of the treatment with a water content of 13 to 17% was lowest and was the highest at 20 to 23%. The NDVI values decreased compared to the first measurement in all treatment, and the decrease was the largest at 13-17% water content and the smallest at 20-23%. Although the difference in NDVI values could be confirmed, it would be difficult to directly relate it to the water stress of plants, and further research on the response of crops to environmental stress and the analysis of multi-spectral image will be needed.

  • PDF

Characteristics of Growth, Yield, and Physiological Responses of Small-Sized Watermelons to Different Soil Moisture Contents Affected by Irrigation Starting Point in a Plastic Greenhouse (소형 수박 시설 재배 시 관수개시점에 따른 토양수분 함량별 생육, 수량 및 생리적 반응 특성 구명)

  • Huh, Yoon-Sun;Kim, Eun-Jeong;Noh, Sol-Ji;Jeon, Yu-Min;Park, Sung-Won;Yun, Geon-Sig;Kim, Tae-Il;Kim, Young-Ho
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.388-398
    • /
    • 2020
  • Watermelon yield mainly depends on soil water content controlled by irrigation in a plastic greenhouse. In this study, we investigated the effect of different soil moisture contents affected by irrigation starting point on growth, yield, and physiological responses of small-sized watermelons. Irrigation was initiated at 5 different levels of soil water content as a starting point with soil moisture detecting sensor after 14 days of transplanting, and stopped at 7 ~ 10 days before harvest. These treatments were compared with the conventional periodic irrigation as control. When soil had the lowest moisture content (-50 kPa), the overall shoot growth was retarded, but the root length and root dry weight increased. The photosynthetic parameters (photosynthetic rate, stomatal conductance, and transpiration rate) of watermelon leaves decreased significantly in the lowest soil moisture content (-50 kPa). On the other hand, the photosynthetic rates of watermelon leaves grown with irrigation starting point between -20 and -40 kPa were observed to be higher than those of other treatments. Fruit set rate and marketable fruit yield increased significantly at -30 kPa and -40 kPa. Proline, abscisic acid (ABA), total phenol and citrulline, which are known to contribute to stress tolerance under drought condition, increased as soil water content decreased, particularly, the largest increases were recorded at -50 kPa. From these results, it was found that an appropriate water supply adjusted with an irrigation starting point between -30 and -40 kPa could help to keep favorable soil water content during the cultivation of small-sized watermelons, promoting the marketable fruit production as well as inducing the vigorous plant growth and reproductive development.

Wearable wireless respiratory monitoring system (의복착용형 무선 호흡모니터 시스템)

  • Lee, In-Kwang;Kim, Seong-Sik;Jang, Jong-Chan;Kim, Koon-Jin;Kim, Kyung-Ah;Lee, Tae-Soo;Cha, Eun-Jong
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.133-142
    • /
    • 2008
  • Respiration is induced by muscular contraction of the chest and abdomen, resulting in the abdominal volume change. Thus, continuous measurement of the abdominal dimension enables to monitor breathing activity. Conductive rubber cord has been previously introduced and tested to develop wearable application for respiratory measurements. The present study implemented wireless wearable respiratory monitoring system with the conductive rubber cord in the patient's pants. Signal extraction circuitry was developed to obtain the abdominal circumference changes reflecting the lung volume variation caused by respiratory activity. Wireless transmission was followed based on the zigbee communication protocol in a size of 65mm${\times}$105mm easily put in pocket. Successful wireless monitoring of respiration was performed in that breathing frequency was accurately estimated as well as different breathing patterns were easily recognized from the abdominal signal. $CO_2$ inhalation experiment was additionally performed in purpose of quantitative estimation of tidal volume. Air mixed with $0{\sim}5%\;CO_2$was inhaled by 4 normal males and the respiratory air flow rate, abdominal dimension change, and end tidal $CO_2$ concentration were simultaneously measured in steady state. $CO_2$ inhalation increased the tidal volume in normal physiological state with a correlation coefficient of 0.90 between the tidal volume and the end tidal $CO_2$ concentration. The tidal volume estimated from the abdominal signal linearly correlated with the accurate tidal volume measured by pneumotachometer with a correlation coefficient of 0.88 with mean relative error of approximately 8%. Therefore, the tidal volume was accurately estimated by measuring the abdominal dimension change.

Body Temperature Monitoring Using Subcutaneously Implanted Thermo-loggers from Holstein Steers

  • Lee, Y.;Bok, J.D.;Lee, H.J.;Lee, H.G.;Kim, D.;Lee, I.;Kang, S.K.;Choi, Y.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.2
    • /
    • pp.299-306
    • /
    • 2016
  • Body temperature (BT) monitoring in cattle could be used to early detect fever from infectious disease or physiological events. Various ways to measure BT have been applied at different locations on cattle including rectum, reticulum, milk, subcutis and ear canal. In other to evaluate the temperature stability and reliability of subcutaneous temperature (ST) in highly fluctuating field conditions for continuous BT monitoring, long term ST profiles were collected and analyzed from cattle in autumn/winter and summer season by surgically implanted thermo-logger devices. Purposes of this study were to assess ST in the field condition as a reference BT and to determine any location effect of implantation on ST profile. In results, ST profile in cattle showed a clear circadian rhythm with daily lowest at 05:00 to 07:00 AM and highest around midnight and rather stable temperature readings (mean${\pm}$standard deviation [SD], $37.1^{\circ}C$ to $37.36^{\circ}C{\pm}0.91^{\circ}C$ to $1.02^{\circ}C$). STs are $1.39^{\circ}C$ to $1.65^{\circ}C$ lower than the rectal temperature and sometimes showed an irregular temperature drop below the normal physiologic one: 19.4% or 36.4% of 54,192 readings were below $36.5^{\circ}C$ or $37^{\circ}C$, respectively. Thus, for BT monitoring purposes in a fever-alarming-system, a correction algorithm is necessary to remove the influences of ambient temperature and animal resting behavior especially in winter time. One way to do this is simply discard outlier readings below $36.5^{\circ}C$ or $37^{\circ}C$ resulting in a much improved mean${\pm}$SD of $37.6^{\circ}C{\pm}0.64^{\circ}C$ or $37.8^{\circ}C{\pm}0.55^{\circ}C$, respectively. For location the upper scapula region seems the most reliable and convenient site for implantation of a thermo-sensor tag in terms of relatively low influence by ambient temperature and easy insertion compared to lower scapula or lateral neck.