Stress Analysis for Bendable Electronic Module Under Thermal-Hygroscopic Complex Loads (열·습도 복합하중에서의 유연성 전자모듈에 대한 구조해석)

  • Han, Changwoon;Oh, Chulmin;Hong, Wonsik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.619-624
    • /
    • 2013
  • A bendable electronic module is developed. In this module, thin silicon electronic chips are embedded in a polymer-based encapsulating adhesive between flexible copper-clad polyimide layers. During the qualification test of a harshly thermal-hygroscopic complex loading condition, delaminations occur inside the module layers. A finite element model is developed for the module. To investigate the effect of hygroscopic stress on delamination, the results of the thermal and thermal-hygroscopic loads are compared. The analysis results reveal that the hygroscopic effect more strongly affects delamination than does the thermal effect. The potential failure mechanisms of the module are investigated based on the stress analysis.

Test case generation strategy and method of embedded software based on POF(Physics of Failure) (POF기반한 내장형 소프트웨어의 테스트 전략)

  • Lee, S.Y.;Jang, J.S.;Jang, S.H.;Ko, B.G.;Choi, K.H.;Park, S.K.;Jung, K.H.;Lee, M.H.
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.05a
    • /
    • pp.607-610
    • /
    • 2004
  • It is still not sufficient for the famous embedded software test methods such as Finite State Machine, Software Cost Reduction and model coverage based test case generation, to pinpoint where bugs hang around and to figure out what makes the bugs. A new approach to ameliorate the drawbacks is proposed in this paper. In the approach, we define a generic model for embedded software. And we also define failure mechanism for embedded software, and a way to generate test cases based on it.

  • PDF

Plasticity of Amorphous Alloys: 1. Homogeneous Deformation (비정질 합금의 소성 1: 균일변형)

  • Park, Kyoung-Won;Lee, Chang-Myeon;Lee, Jae-Chul
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.11
    • /
    • pp.759-772
    • /
    • 2009
  • Amorphous alloys, in addition to being promising materials for a variety of practical applications, provide an excellent test bed for evaluating our understanding of the underlying physics on deformation in amorphous solids. Like many amorphous materials, amorphous alloys can exhibit either homogeneous or inhomogeneous deformation depending on the stress level. The mode of deformation has a strong influence on whether the material behavior is classified as ductile or brittle. It was observed that the characteristics of these deformations are largely dependent on the atomic-scale structures of the alloys and determine the amount of the plastic deformation prior to failure. In this study, the structural features that control the homogeneous deformation of amorphous alloys are outlined on the basis on experiments and molecular dynamics simulations.

Time Dependent Reliability Analysis of the Degrading RC Containment Structures Subjected to Earthquake Load (지진하중을 받는 RC 격납건물의 열화에 따른 신뢰성 해석)

  • 오병환
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.04a
    • /
    • pp.233-240
    • /
    • 2000
  • Nuclear power plant structures may be exposed to aggressive environmental effects than may cause their strength and stiffness to decrease over their service lives, Although the physics of these damage mechanisms are reasonably well understood and quantitative evaluation of their effects on time-dependent structural behavior is possible in some instances such evaluations are generally very difficult and remain novel. The assessment of existing RC containment in nuclear power plants for continued service must provide quantitative evidence that they are able to withstand future extreme loads during a service period with an acceptable level of reliability. Rational methodologies to perform the reliability assessment can be developed from mechanistic models of structural deterioration using time-dependent structural reliability analysis to take earthquake loading uncertainties into account. The final goal of this study is to develop the reliability analysis of RC containment structures. The cause of the degrading is first clarified and the reliability assessment has been conducted. By introducing stochastic analysis based on random vibration theory the reliability analysis which can determine the failure probabilities has been established.

  • PDF

Acceleration Test for Package of High Power Phosphor Converted White Light Emitting Diodes (고출력 형광체변환 백색 LED 패키지의 가속시험)

  • Chan, Sung-Il;Yu, Yang-Gi;Jang, Joong-Soon
    • Journal of Applied Reliability
    • /
    • v.10 no.2
    • /
    • pp.137-148
    • /
    • 2010
  • This study deals with the accelerated life test of high power phosphor converted white Light Emitting Diodes (High power LEDs). Samples were aged at $110^{\circ}C$/85% RH and $130^{\circ}C$/85% RH up to 900 hours under non-biased condition. The stress induced a luminous flux decay on LEDs in all the conditions. Aged devices exhibited modification of package silicon color from white to yellowish brown. The instability of the package contributes to the overall degradation of optical lens and structural degradations such as generating bubbles. The degradation mechanisms of lumen decay and reduction of spectrum intensity were ascribed to hygro-mechanical stress which results in package instabilities.

Surgical Treatment of Lung Cancer with Bronchoplastic Procedures (기관지 성형술을 이용한 폐암의 수술적 치료)

  • Kim, Dong-Won;Park, Ju-Cheol
    • Journal of Chest Surgery
    • /
    • v.28 no.10
    • /
    • pp.911-916
    • /
    • 1995
  • Thirteen patients with lung cancer have undergone bronchoplastic procedures from January 1991 to July 1994 in Kyung Hee univ. Hospital.Among them,twelve patients were male and one patient was female from 33 to 76 years of age.[ mean 56.6 11.5 years of age The pathologic diagnoses were squamous cell carcinoma in twelve patients and adenoid cystic carcinoma in one patient.The bronchoplastic procedures consisted of seven right upper sleeve lobectomies, one right middle sleeve lobectomy, one left lower sleeve lobectomy and four sleeve pneumonectomies. In these sleeve pneumonectomies, right sleeve pneumonectomy was done in three patients and the other was left sleeve pneumonectomy. Including the four sleeve pneumonectomies, carinoplasty was performed in seven patients. Postoperatively, we carried out bronchoscopic suction of intrabronchial secretions in necessary for the prevention of postoperative complication. All except one were discharged without any complication and have been in good condition. Postoperative mortality was in one patient who expired 25days after right middle sleeve lobectomy with respiratory failure.

  • PDF

Immunological Recognition by Artificial Neural Networks

  • Xu, Jin;Jo, Junghyo
    • Journal of the Korean Physical Society
    • /
    • v.73 no.12
    • /
    • pp.1908-1917
    • /
    • 2018
  • The binding affinity between the T-cell receptors (TCRs) and antigenic peptides mainly determines immunological recognition. It is not a trivial task that T cells identify the digital sequences of peptide amino acids by simply relying on the integrated binding affinity between TCRs and antigenic peptides. To address this problem, we examine whether the affinity-based discrimination of peptide sequences is learnable and generalizable by artificial neural networks (ANNs) that process the digital experimental amino acid sequence information of receptors and peptides. A pair of TCR and peptide sequences correspond to the input for ANNs, while the success or failure of the immunological recognition correspond to the output. The output is obtained by both theoretical model and experimental data. In either case, we confirmed that ANNs could learn the immunological recognition. We also found that a homogenized encoding of amino acid sequence was more effective for the supervised learning task.

Time Dependent Reliability Analysis of the Degrading RC Containment Structures Subjected to Earthquake Load (지진하중을 받는 RC 격납건물의 열화에 따른 신뢰성 해석)

  • 오병환;최성철;현창헌
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.559-564
    • /
    • 2000
  • Nuclear power plant structures amy be exposed to aggressive environmental effects that may cause their strength and stiffness to decrease over their service lives. Although the physics of these damage mechanisms are reasonably well understood and quantitative evaluation of their effects on time-dependent structural behavior is possible in some instances, such evaluations are generally very difficult and remain novel. The final goal of this study is to develop the reliability analysis of RC containment structures. The cause of the degrading is first clarified and the reliability assessment has been conducted. By introducing stochastic analysis based on random vibration theory, the reliability analysis which can determine the failure probabilities has been established.

  • PDF

Numerical Investigation of Hemodynamics in a Bileaflet Mechanical Heart Valve using an Implicit FSI Based on the ALE Approach

  • Hong, Tae-Hyub;Choi, Choeng-Ryul;Kim, Chang-Nyung
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2410-2414
    • /
    • 2008
  • Human heart valves diseased by congenital heart defects, rheumatic fever, bacterial infection, cancer may cause stenosis or insufficiency in the valves. Treatment may be with medication but often involves valve repair or replacement (insertion of an artificial heart valve). Bileaflet mechanical heart valves (BMHVs) are widely implanted to replace the diseased heart valves, but still suffer from complications such as hemolysis, platelet activation, tissue overgrowth and device failure. These complications are closely related to both flow characteristics through the valves and leaflet dynamics. In this study, the physiological flow interacting with the moving leaflets in a bileaflet mechanical heart valve (BMHV) is simulated with a strongly coupled implicit fluid-structure interaction (FSI) method which is newly organized based on the Arbitrary-Lagrangian-Eulerian (ALE) approach and the dynamic mesh method (remeshing) in FLUENT. The simulated results are in good agreement with previous experimental studies. This study shows the applicability of the present FSI model to the complicated physics interacting between fluid flow and moving boundary.

  • PDF

A Stochastic Analysis in Fatigue Strength of Degraded Steam Turbine Blade Steel (열화된 증기 터빈블레이드의 피로강도에 대한 확률론적 해석)

  • Kim, Chul-Su;Jung, Hwa-Young;Kim, Jung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.262-267
    • /
    • 2001
  • In this study, the Reliability of degraded steam turbine blade was evaluated using the limited fatigue data. The statistical estimation of limited fatigue data implies that some unknown uncertainties which may be involved in fatigue reliability analysis. Therefore, an appropriate distribution in the fatigue strength was determined by the characteristic distribution - linear correlation coefficient, fatigue physics, error parameter. 3-parameter Weibull distribution is the most appropriate distribution to assume for infinite region. The load applied on the blade is mainly tensile. The maximum Von-Mises stress is 219.4 MPa at the steady state service condition. The failure probability($F_p$) derived from the strength-stress interference model using Monte carlo simulation under variable service condition is 0.25% at the 99.99% confidence level.