• Title/Summary/Keyword: Physics experiment

Search Result 447, Processing Time 0.037 seconds

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation (몬테 카를로 전산모사를 통한 EPID의 외부적 선량 재구성과 내부 선량 계측과의 비교 및 분석)

  • Jung, Joo-Young;Yoon, Do-Kun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.253-258
    • /
    • 2013
  • The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic portal imaging device (EPID) and the internal dose derived from the Monte Carlo simulation. As a comparative analysis of the two cases, it is performed to provide a basic indicator for similar studies. The geometric information of the experiment and that of the radiation source were entered into Monte Carlo n-particle (MCNPX) which is the computer simulation tool and to derive the EPID images, a tally card in MCNPX was used for visualizing and the imaging of the dose information. We set to source to surface distance (SSD) 100 cm for internal measurement and EPID. And the water phantom was set to be 100 cm of the source to surface distance (SSD) for the internal measurement and EPID was set to 90 cm of SSD which is 10 cm below. The internal dose was collected from the water phantom by using mesh tally function in MCNPX, accumulated dose data was acquired by four-portal beam exposures. At the same time, after getting the dose which had been passed through water phantom, dose reconstruction was performed using back-projection method. In order to analyze about two cases, we compared the penetrated dose by calibration of itself with the absorbed one. We also evaluated the reconstructed dose using EPID and partially accumulated (overlapped) dose in water phantom by four-portal beam exposures. The sum dose data of two cases were calculated as each 3.4580 MeV/g (absorbed dose in water) and 3.4354 MeV/g (EPID reconstruction). The result of sum dose match from two cases shows good agreement with 0.6536% dose error.

The Enhancement Scheme of Elementary School Students Fire Fighting Safety Education by the Fire Fighting Science Class (소방과학교실을 통한 초등학생 소방안전교육 제고방안)

  • Cha, Jeong-Min;Song, Yun-Suk;Hyun, Seong-Ho
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.270-276
    • /
    • 2008
  • The purpose of this study is to deal with fire fighting safety education primarily among the fields of child safety education. So, first of all, this study considered the theoretical background of fire fighting safety education. And this study analyzed the present state and cases of safety accidents in elementary schools. And by focusing on the fire fighting science class for elementary schools which Gyeonggi-do Goyang fire station is executing now, this study analyzed the educational outline, present state, educational goal, and content of fire fighting science class, and conducted the satisfaction survey through questionnaire over the elementary school students participating in fire fighting science class and the fire fighting officers in charge of fire fighting science class. On basis of this research, by developing the new field of fire fighting education and publicity into the program which can diffuse the fire fighting-related chemical experiment based on the science of chemistry and physics in the future and so provide the pleasure and surprise of experiencing directly not only natural fire fighting education and publicity but also learning and the common sense of fire fighting, this study tried to present the alternatives about the measures for activating the fire fighting safety education in elementary schools.

  • PDF

Laser induced dry etching of GaAs (레이저유기에 의한 GaAs의 건식에칭)

  • Park, Se-Ki;Lee, Choen;Choi, Won-Chel;Kim, Moo-Sung;Min, Suk-Ki;Ahn, Byung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1995.05a
    • /
    • pp.58-61
    • /
    • 1995
  • Instead of using CCl$_4$CCl$_2$F$_2$ gases, we used a alternative reaction gas of CFCs which we have developed, for the experiment of laser induced dry etching of laser induced dry etching of GaAs, and compared with the etch profile of a usual reation gas. Laser powers(power density) on the sample surface were varied from 100 mW(12.7 MW/$\textrm{cm}^2$) to 210mW(27 MW/$\textrm{cm}^2$) The laser beam was scanned over the sample by moving the cell with a speed raging from 8.3$\mu\textrm{m}$/sec and the gas pressure also was varied form 260 Torr to 760 Torr, High etching rates up to 136 $\mu\textrm{m}$/sec and an aspect ratio of 2.6 have been achieved by single scan of laser beam. The chemical compositions of the reaction products deposited on the etched groove were measured by Auger electron spectroscopy(AES) Etch profiles, including depth and width were observed by scanning electron microscopy(SEM)

  • PDF

Second harmonic generation of pulsed corona - poled nonlinear optical polymer films (펄스 corona 배향된 비선형광학 고분자박막의 제2 고조파발생)

  • Kim, Jun-Soo;Lee, Jong-Ha;Lee, Hwang-Un;Kim, Sang-Youl;Won, Young-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.4
    • /
    • pp.356-362
    • /
    • 2002
  • The molecular orientational dynamics of the nonlinear optical(NLO) side-chain polymer N-(4-nitrophenyl)-(L)-prolinol-poly (pphenylene terephthalates) have been studied using nonlinear optical responses as measured by second harmonic generation (SHG). A new pulsed corona poling is used to orient the NLO chromophores and the polymer segments into the noncentrosymmetric structure required to obtain the SHG signal. By corona poling of negative high voltage pulses with variable repetition rates (between 0.5 and 10 ㎑) at temperature between 25$^{\circ}C$ and 80$^{\circ}C$, well below and about the glass transition temperature 70$^{\circ}C$, the side-chain chromophores and the polymer chain contour rearrange themselves and create the domain structure observed by atomic force microscopy(AFM). The pulsed corona voltage enhances the orientational ordering of the NLO chromophores and also significantly influences the growth of SHG signal and the improved relaxation behavior after the poling field is removed, reducing the visible damage to the polymer film dramatically. This new pulsed corona poling experiment gave direct in situ evidence that the NLO chromophore and the polymer backbone undergo anisotropic rearrangement during the poling process.

Analysis of Learning Effect on Multitude of Screens in Video Demonstration -On High School's Physics- (시범실험 동영상의 다중화면 학습 효과 분석 -고등학교 물리교과 중심으로-)

  • Lee, Seung-Bok;Jeon, Byeong-Ho
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.9
    • /
    • pp.240-247
    • /
    • 2007
  • The purpose of this study was to analyze the learning effects of video demonstration in a multitude of video screens in a science class. To examine this, an experiment from the first year science textbook was chosen, which looked at the relationship between electrical voltage and electrical current. Three experimental groups were used for the purpose of this study: 1/ a control group which used experimental still photos during a traditional class. 2/ experimental group A which used videos in a single screen, and 3/ experimental group B which used a multitude of video screens to demonstrate their effects. Post test learning effects was then carried out on each group related to the units. The results showed an improvement in grade for all groups. Experimental group B showed the most significant result, followed by the experimental group A. The control group showed the least significant grade improvement. In conclusion, the study revealed that the utilization of video demonstration in a science class is very useful and can be adapted in different forms in class. To enhance the effects of the learning method in conveying efficient meaning, versatile methods should be used to stimulate and heighten students' interests by mixing still photographs and video demonstration with various screen composition with the help of information technology.

Design and Implementation of Ganga Plugins for Grid Interoperability (그리드 상호 운용을 위한 Ganga 플러그인 설계 및 구현)

  • Kim, Han-Gi;Hwang, Soon-Wook;Lee, Yoon-Ki;Kim, Eun-Sung;Yeom, Heon-Y.
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.15 no.12
    • /
    • pp.881-890
    • /
    • 2009
  • To solve big problem in high energy physics or bioinformatics, it needs a large number of computing resources. But it hard to be provided by one grid environment. While user can submit each job by using it's own user interface in each grid environment, it may need many cost and efforts to manage several hundred jobs conserved in each grid environment separately. In this paper, to solve this problem we develop Ganga's Gridway backend and InterGrid backend. Therefore as we provide the same grid user interface between different grid environments. We developed a Gridway backend module that provide users with access to globus-based grid resources as well. We have also developed an InterGrid backend that allows users to submit jobs that have access to both glite-based resources and globus-based resources. In order to demonstrate the practicality of the new backend plugin modules, we have integrated the AutoDock application used by WISDOM project into Ganga as a new built-in application plugin for Ganga. And we preformed interoperability experiment between PRAGMA grid based on Globus and EGEE grid based on gLite.

한국원자력연구소 방사선방어기술 개발 및 연구 현황

  • Ha, Jeong-U
    • Journal of Radiation Protection and Research
    • /
    • v.15 no.1
    • /
    • pp.9-13
    • /
    • 1990
  • 1959년 한국원자력연구소가 창립됨과 동시에 &Health Physics&, 즉 보건물리라고 하는 명칭과 조직이 탄생되어, 방사선안전관리의 실무와 보건물리의 연구가 시작되었다. 최초 10년간은 선진제국의 보건물리분야의 연구와 기술을 추적하여 우리나라의 방사선안전관리 기술의 기초를 다지는 시기로서 개인방사선모니터링기술, 환경방사선(능) 모니터링기술 및 방사선방어용계측기기의 교정기술 개발에 중점을 두고 연구개발이 추진되었으며, TRIGA Mark-II 연구용원자로의 가동에 따라 원자로 생체차폐체의 건전성 검증에 관한 유익한 방사선량 측정자료도 얻게 되었다. 즉 이 기간은 방사선안전관리의 체제정비 및 기초기술 확립에 노력한 기간이었다. 1970년대는 원자력 연구개발에 대한 기본방향과 정책의 변경등으로 보건물리 연구조직은 방사선안전관리, 환경연구 그리고 방사화학분야로 분산되었으며, 그로인하여 연구개발활동은 거의 정체되어 겨우 방사선안전관리 실무만이 그 명맥을 유지하였다. 그 결과 우리나라 방사선안전관리 및 그와 관련된 연구개발의 기반이 흔들리게 되었으나, 그러한 환경하에서도 방사선량측정평가기술, 방사선차폐설계기술 및 원자로사고시 피폭선량평가기술의 선진화에 필요한 지식을 얻었으며, 방사선 안전관리에 유익한 실무경험도 축적하게 되었다. 1980년대는 통합된 원자력 연구개발체제의 구축으로 방사선작업종사자 및 일반공중의 피폭저감화 기술개발에 필요한 각종 최신기술을 도입하였고, 관리업무에 있어서도 측정의 정확도와 신뢰성향상 및 새로운 관리기술의 개발에 많은 노력을 한 결과, 유익한성과를 얻게된 기간이다. 특히, 이 기간은 방사선안전관리기술의 선진화를 위한 지식이 축적되어 90년대의 방사선안전관리기술자립화를 위한 전환기로서, 이와같이 축적된 기술은 원자력의 평화적 이용에 크게 기여할 것으로 기대된다.서 dithiothreitol를 투여한 군에서는 우라늄단독투여군에 비해 cretinine의 배설이 상당히 증가하였다(P<0.05). 6. 우라늄오염에 의한 신장의 소견에 있어 우라늄단독투여군은 근위곡세뇨관상피의 공포화 및 종창, microvilli와 brush border의 손실, 세뇨관 상피의 괴사가 관찰되었으며, 간장의 충혈, 중심성 괴사 및 모세관 확장증도 관찰되었다. 그리고 sodium bicarbonate와 생리적 식염수를 병행투여한 군과 우라늄을 투여하고 30분이 지나서 dithiothreitol를 투여한 군에서는 우라늄 단독투여군에 비해 높은 방호효과가 관찰되었으나 다른 실험군에서는 큰 효과가 없는 것으로 나타났다. 결론적으로 우라늄의 체내오염시에는 sodium bicarbonate와 생리적 식염수를 가능한 빨리 병행투여하거나 dithiothreitol을 체내오염후 30분이 지나서 투여하는 방법이 우라늄오염에 대한 제염에 매우 유효할 것으로 생각되며, 특히 우라늄에 의한 인체장해를 유의하게 경감시켜줄 것으로 사료되었다.내의 어떤 부위와도 관계가 되는 것으로 간주되는데 이것이 $(^3H)$ QNB가 $(^3H)$ NMS보다 높은 최대 결합능력 $(B_{max})$을 나타낼 이유이다. (b) 두 종류의 다른 제제에서 우리는 같은 양상의 결과를 관찰하었기에 결점이 많은 homogenates 제제보다는 intact cell aggregates 제제를 수용체 연구에 대한 새로운 실험모형(experiment model)으로 사용할 수 있는 가능성을 제시하고자 한다.$가 38.8%로 가장 많고, 그 다음이 ${\ulcorner}$l9세(歲)이후${\lrcorner}$가 25.2%로서 전체

  • PDF

Splitting of Surface Plasmon Resonance Peaks Under TE- and TM-polarized Illumination

  • Yoon, Su-Jin;Hwang, Jeongwoo;Lee, Myeong-Ju;Kang, Sang-Woo;Kim, Jong-Su;Ku, Zahyun;Urbas, Augustine;Lee, Sang Jun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.296-296
    • /
    • 2014
  • We investigate experimentally and theoretically the splitting of surface plasmon (SP) resonance peaks under TE- and TM-polarized illumination. The SP structure at infrared wavelength is fabricated with a 2-dimensional square periodic array of circular holes penetrating through Au (gold) film. In brief, the processing steps to fabricate the SP structure are as follows. (i) A standard optical lithography was performed to produce to a periodic array of photoresist (PR) circular cylinders. (ii) After the PR pattern, e-beam evaporation was used to deposit a 50-nm thick layer of Au. (iii) A lift-off processing with acetone to remove the PR layer, leading to final structure (pitch, $p=2.2{\mu}m$; aperture size, $d=1.1{\mu}m$) as shown in Fig. 1(a). The transmission is measured using a Nicolet Fourier-transform infrared spectroscopy (FTIR) at the incident angle from $0^{\circ}$ to $36^{\circ}$ with a step of $4^{\circ}$ both in TE and TM polarization. Measured first and second order SP resonances at interface between Au and GaAs exhibit the splitting into two branches under TM-polarized light as shown in Fig. 1(b). However, as the incidence angle under TE polarization is increased, the $1^{st}$ order SP resonance peak blue-shifts slightly while the splitting of $2^{nd}$ order SP resonance peak tends to be larger (not shown here). For the purpose of understanding our experimental results qualitatively, SP resonance peak wavelengths can be calculated from momentum matching condition (black circle depicted in Fig. 2(b)), $k_{sp}=k_{\parallel}{\pm}iG_x{\pm}jG_y$, where $k_{sp}$ is the SP wavevector, $k_{\parallel}$ is the in-plane component of incident light wavevector, i and j are SP coupling order, and G is the grating momentum wavevector. Moreover, for better understanding we performed 3D full field electromagnetic simulations of SP structure using a finite integration technique (CST Microwave Studio). Fig. 1(b) shows an excellent agreement between the experimental, calculated and CST-simulated splitting of SP resonance peaks with various incidence angles under TM-polarized illumination (TE results are not shown here). The simulated z-component electric field (Ez) distribution at incident angle, $4^{\circ}$ and $16^{\circ}$ under TM polarization and at the corresponding SP resonance wavelength is shown in Fig. 1(c). The analysis and comparison of theoretical results with experiment indicates a good agreement of the splitting behavior of the surface plasmon resonance modes at oblique incidence both in TE and TM polarization.

  • PDF

Fabrication and Its Characteristics of Ion Energy Spectrometer for Diagnostics of Plasma (플라즈마 진단을 위한 이온에너지 분석장치의 제작 및 특성 조사)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.163-170
    • /
    • 1998
  • An ion energy spectrometer which has the $45^{\circ}$ parallel electrostatic deflection plate was designed and constructed for measuring ion temperature in high temperature plasma. The energy calibration and the energy resolution were studied in detail for a hydrogen ion at the $0.24{\sim}1.92\;keV$ energy using electrostatic accelerator with a duoplasmatron ion source. The voltage of the deflection plate was linearly increased for the decreased ion detector position at the constant ion energy and decreased for the increased ion energy at the fixed ion detector position. The inclination of the deflection plate voltage to the ion energy was between 0.92 and 1.61, and linearly decreased for the increased the ion detector position. The measured energy resolution, which is $4.2%\;{\sim}\;11.6%$ in this experiment region, was improved for the increased ion dector position and ion energy. The relative efficiency was increased for the decreased the ion detector position. The ion energy spectrum of the DC plasma in the multi-purpose plasma generator was measured using this equipment. The ion temperature was 203-205 eV at the discharge voltage 320 V, discharge current 1.7 A.

  • PDF