• 제목/요약/키워드: Physico-mechanical

검색결과 72건 처리시간 0.026초

Mechanical properties and microstructure of innovative bio-mortar containing different aggregates

  • Abo-El-Eanein, S.A.;Abdel-Gawwad, H.A.;El-Mesallamy, Amani M.D.;El-Belbasi, Hussein I.;Ayoub, Hebah. G.
    • Geosystem Engineering
    • /
    • 제21권5호
    • /
    • pp.291-296
    • /
    • 2018
  • The aim of this work is to study the effect of aggregate type on the physico-mechanical properties and microstructure of bio-mortar (BM). Three different aggregates such as sand, dolomite and basalt were used. BM was prepared by mixing aggregates with bacterial cells (Sporosarcina Pasteurii) and one equimolar (1 M) of $urea/CaCl_2.2H_2O$. The results proved that the chemical composition and physical properties of aggregates play an important role in the microbial precipitation rate as well as size, morphology and crystallinity of the precipitated calcite, which strongly reflects on the properties of the prepared BM. The BM containing dolomite gave the highest compressive strength and lowest water absorption.

방사성 폐기물 저장을 위한 불연속 암반의 특성 및 고온하에서의 암반의 수리열역학적 상호작용에 관한 연구 (A Study on Characteristics of Jointed Rock Masses and Thermo-hydro-mechanical Behavior of Rock Mass under High Temperature)

  • 이희근;김영근;이희석
    • 터널과지하공간
    • /
    • 제8권3호
    • /
    • pp.184-193
    • /
    • 1998
  • 방사성 폐기물의 안전한 처분을 위해서는 암반의 역학적, 열적, 유체 거동 뿐 아니라 암반과 물 사이의 물리 화학적 상호작용을 이해할 필요가 있다. 또한 지질구조, 지하현지응력, 습곡, 열수작용, 마그마의 관입, 판구조 등과 같은 많은 조건을 모델링하고 예측하기 위해서는 암석의 역학적, 수리적 특성을 알아야 한다. 이 연구는 심부 암반에 폐기물 처분과 관련된 암석역학적인 사항들에 대해 연구들에 기초하고 있다. 이 논문은 변하는 온도 상태에서 암반의 역학적 수리적 거동, 암반의 열-수리-역학적 상호작용 해석과 불연속 암석의 거동 특성 등을 포함한다. 역학적 특성은 Interaken 암석역학 시험 시스템으로 측정되었으며, 수리적 특성에는 순간 증압 투수계수 측정 시스템이 사용되었다. 모든 결과에서 암석 특성은 온도 변화에 민감함을 보였다.

  • PDF

Characterization and antimicrobial efficacy of Portland cement impregnated with silver nanoparticles

  • Nam, Ki Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권3호
    • /
    • pp.217-223
    • /
    • 2017
  • PURPOSE. This study investigated the effects of silver nanoparticle (SN) loading into hydraulic calcium silicate-based Portland cement on its mechanical, antibacterial behavior and biocompatibility as a novel dental bone substitute. MATERIALS AND METHODS. Chemically reduced colloidal SN were combined with Portland cement (PC) by the concentrations of 0 (control), 1.0, 3.0, and 5.0 wt%. The physico-mechanical properties of silver-Portland cement nanocomposites (SPNC) were investigated through X-ray diffraction (XRD), setting time, compressive strength, solubility, and silver ion elution. Antimicrobial properties of SPNC were tested by agar diffusion against Streptococcus mutans and Streptococcus sobrinus. Cytotoxic evaluation for human gingival fibroblast (HGF) was performed by MTS assay. RESULTS. XRD certified that SN was successfully impregnated in PC. SPNC at above 3.0 wt% significantly reduced both initial and final setting times compared to control PC. No statistical differences of the compressive strength values were detected after SN loadings, and solubility rates of SPNC were below 3.0%, which are acceptable by ADA guidelines. Ag ion elutions from SPNC were confirmed with dose-dependence on the concentrations of SN added. SPNC of 5.0 wt% inhibited the growth of Streptococci, whereas no antimicrobial activity was shown in control PC. SPNC revealed no cytotoxic effects to HGF following ISO 10993 (cell viability > 70%). CONCLUSION. Addition of SN promoted the antibacterial activity and favored the bio-mechanical properties of PC; thus, SPNC could be a candidate for the futuristic dental biomaterial. For clinical warrant, further studies including the inhibitory mechanism, in vivo and long-term researches are still required.

Investigation of the effect of internal curing as a novel method for improvement of post-fire properties of high-performance concrete

  • Moein Mousavi;Habib Akbarzadeh Bengar
    • Computers and Concrete
    • /
    • 제33권3호
    • /
    • pp.309-324
    • /
    • 2024
  • Internal curing, a widely used method for mitigating early-age shrinkage in concrete, also offers notable advantages for concrete durability. This paper explores the potential of internal curing by partial replacement of sand with fine lightweight aggregate for enhancing the behavior of high-performance concrete at elevated temperatures. Such a technique may prove economical and safe for the construction of skyscrapers, where explosive spalling of high-performance concrete in fire is a potential hazard. To reach this aim, the physico-mechanical features of internally cured high-strength concrete specimens, including mass loss, compressive strength, strain at peak stress, modulus of elasticity, stress-strain curve, toughness, and flexural strength, were investigated under different temperature exposures; and to predict some of these mechanical properties, a number of equations were proposed. Based on the experimental results, an advanced stress-strain model was proposed for internally cured high-performance concrete at different temperature levels, the results of which agreed well with the test data. It was observed that the replacement of 10% of sand with pre-wetted fine lightweight expanded clay aggregate (LECA) not only did not reduce the compressive strength at ambient temperature, but also prevented explosive spalling and could retain 20% of its ambient compressive strength after heating up to 800℃. It was then concluded that internal curing is an excellent method to enhance the performance of high-strength concrete at elevated temperatures.

Influence of heat treatment on the microstructure and the physical and mechanical properties of dental highly translucent zirconia

  • Dimitriadis, Konstantinos;Sfikas, Athanasios Konstantinou;Kamnis, Spyros;Tsolka, Pepie;Agathopoulos, Simeon
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권2호
    • /
    • pp.96-107
    • /
    • 2022
  • PURPOSE. Microstructural and physico-mechanical characterization of highly translucent zirconia, prepared by milling technology (CAD-CAM) and repeated firing cycles, was the main aim of this in vitro study. MATERIALS AND METHODS. Two groups of samples of two commercial highly-translucent yttria-stabilized dental zirconia, VITA YZ-HTWhite (Group A) and Zolid HT + White (Group B), with dimensions according to the ISO 6872 "Dentistry - Ceramic materials", were prepared. The specimens of each group were divided into two subgroups. The specimens of the first subgroups (Group A1 and Group B1) were merely the sintered specimens. The specimens of the second subgroups (Group A2 and Group B2) were subjected to 4 heat treatment cycles. The microstructural features (microstructure, density, grain size, crystalline phases, and crystallite size) and four mechanical properties (flexural strength, modulus of elasticity, Vickers hardness, and fracture toughness) of the subgroups (i.e. before and after heat treatment) were compared. The statistical significance between the subgroups (A1/A2, and B1/B2) was evaluated by the t-test. In all tests, P values smaller than 5% were considered statistically significant. RESULTS. A homogenous microstructure, with no residual porosity and grains sized between 500 and 450 nm for group A and B, respectively, was observed. Crystalline yttria-stabilized tetragonal zirconia was exclusively registered in the X-ray diffractograms. The mechanical properties decreased after the heat treatment procedure, but the differences were not statistically significant. CONCLUSION. The produced zirconia ceramic materials can be safely (i.e., according to the ISO 6872) used in extensive fixed prosthetic restorations, such as substructure ceramics for three-unit prostheses involving the molar restoration and substructure ceramics for prostheses involving four or more units. Consequently, milling technology is an effective manufacturing technology for producing zirconia substructures for dental fixed all-ceramic prosthetic restorations.

Vibration analysis and optimization of functionally graded carbon nanotube reinforced doubly-curved shallow shells

  • Hammou, Zakia;Guezzen, Zakia;Zradni, Fatima Z.;Sereir, Zouaoui;Tounsi, Abdelouahed;Hammou, Yamna
    • Steel and Composite Structures
    • /
    • 제44권2호
    • /
    • pp.155-169
    • /
    • 2022
  • In the present paper an analytical model was developed to study the non-linear vibrations of Functionally Graded Carbon Nanotube (FG-CNT) reinforced doubly-curved shallow shells using the Multiple Scales Method (MSM). The nonlinear partial differential equations of motion are based on the FGM shallow shell hypothesis, the non-linear geometric Von-Karman relationships, and the Galerkin method to reduce the partial differential equations associated with simply supported boundary conditions. The novelty of the present model is the simultaneous prediction of the natural frequencies and their mode shapes versus different curvatures (cylindrical, spherical, conical, and plate) and the different types of FG-CNTs. In addition to combining the vibration analysis with optimization algorithms based on the genetic algorithm, a design optimization methode was developed to maximize the natural frequencies. By considering the expression of the non-dimensional frequency as an objective optimization function, a genetic algorithm program was developed by valuing the mechanical properties, the geometric properties and the FG-CNT configuration of shallow double curvature shells. The results obtained show that the curvature, the volume fraction and the types of NTC distribution have considerable effects on the variation of the Dimensionless Fundamental Linear Frequency (DFLF). The frequency response of the shallow shells of the FG-CNTRC showed two types of nonlinear hardening and softening which are strongly influenced by the change in the fundamental vibration mode. In GA optimization, the mechanical properties and geometric properties in the transverse direction, the volume fraction, and types of distribution of CNTs have a considerable effect on the fundamental frequencies of shallow double-curvature shells. Where the difference between optimized and not optimized DFLF can reach 13.26%.

Influence of Alkali and Silane Treatment on the Physico-Mechanical Properties of Grewia serrulata Fibres

  • JAIN, Bhupesh;MALLYA, Ravindra;NAYAK, Suhas Yeshwant;HECKADKA, Srinivas Shenoy;PRABHU, Shrinivasa;MAHESHA, G.T.;SANCHETI, Gaurav
    • Journal of the Korean Wood Science and Technology
    • /
    • 제50권5호
    • /
    • pp.325-337
    • /
    • 2022
  • Grewia serrulata fibres were chemically treated with 3%, 6%, and 9% NaOH for the duration of 4 h. Additionally, the NaOH-treated fibres were also treated with 3 - (trimethoxysilyl) propyl methacrylate (silane). Properties such as density and tensile strength of the treated fibres were compared against the untreated fibres. The highest density was obtained in the case of 9% NaOH + silane treated fibres, which was 26.47% higher than untreated fibres, implying effective removal of hemicellulose. Likewise, the highest tensile strength was also obtained in the case of 9% NaOH + silane treated fibres. The increment observed in the tensile strength of the natural fibres was related to the removal of impurities, hemicellulose, and stress-raisers as well as deposition over the fibre surface that smoothed it. These observations were further validated by estimating changes in chemical constituents due to chemical treatment along with characterization techniques such as scanning electron microscopy and thermogravimetric analysis.

Effects of Electron Beam Irradiation on Tribological and Physico-chemical Properties of Polyoxymethylene (POM-C) copolymer

  • ;;;;김민석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.153-153
    • /
    • 2016
  • Polyoxymethylene copolymer (POM-C) is an attractive and widely used engineering thermoplastic across many industrial sectors owing to outstanding physical, mechanical, self-lubricating and chemical properties. In this research work, the POM-C blocks were irradiated with 1 MeV electron beam energy in five doses (100, 200, 300, 500 and 700 KGy) in vacuum condition at room temperature. The tribological and physico-chemical properties of electron beam irradiated POM-C blocks have been analyzed using Pin on disk tribometer, Raman spectroscopy, SEM-EDS, Optical microscopy, 3D Nano surface profiler system and Contact angle analyzer. Electron beam irradiation at a dose of 100 kGy resulted in a decrease of the friction coefficient and wear loss of POM-C block due to well suited cross-linking, carbonization, free radicals formation and energetic electrons-atoms collisions (physical interaction). It also shows lowest surface roughness and highest water contact angle among all unirradiated and irradiated POM-C blocks. The irradiation doses at 200, 300, 500 and 700 kGy resulted in increase of the friction coefficient as compared to unirradiated POM-C block due to severe chain scission, chemical and physical structural degradation. The electron beam irradiation transferred the wear of unirradiated POM-C block from the abrasive wear, adhesive wear and scraping to mild scraping for the 1 MeV, 100 kGy irradiated POM-C block which is concluded from SEM-EDS and Optical microscopic observations. The degree of improvement for tribological attribute relies on the electron beam irradiation condition (energy and dose rate).

  • PDF

Physico-mechanical, AC-conductivity and microstructural properties of FeCl3 doped HPMC polymer films

  • Prakash, Y.;Somashekarappa, H.;Manjunath, A.;Mahadevaiah, Mahadevaiah;Somashekar, R.
    • Advances in materials Research
    • /
    • 제2권1호
    • /
    • pp.37-49
    • /
    • 2013
  • The transition metal salt doped solid polymer electrolyte [TSPE] were prepared with HPMC as a host polymer. The virgin and doped films were prepared by solution-casting method and investigated using wide angle X-ray scattering method. Micro structural parameters like lattice strain (g%), stacking/twin faults, the average number of unit cells counted in a direction perpendicular to the Bragg's plane (hkl) spacing of (hkl) planes dhkl, crystallite size Ds, distortion width, standard deviation were determined by whole pattern powder fitting (WPPF) method, which is an extension of single order method. It is found that the crystallite size decreases with the increase in the content of $FeCl_3$. This decrease is due to increase in localized breaking of polymer network which also accounts for the amorphous nature of the material. The filler inorganic salt $FeCl_3$ acts as plasticizer. FTIR study also confirms and justifies the interaction between the polymer and in-organic salt in the matrix. Physical properties like mechanical stability and Ac conductivity in these films are in conformity with the X-ray results.

Geomechanical analysis of elastic parameters of the solid core of the Earth

  • Guliyev, Hatam H.
    • Geomechanics and Engineering
    • /
    • 제14권1호
    • /
    • pp.19-27
    • /
    • 2018
  • It follows from the basic principles of mechanics of deformable solids relating to the strength, stability and propagation of elastic waves that the Earth's inner core cannot exist in the form of a spherical structure in the assumed thermobaric conditions and calculation values of physico-mechanical parameters. Pressure level reaches a value that is significantly greater than the theoretical limit of medium strength in the model approximations at the surface of the sphere of the inner core. On the other hand, equilibrium state of the sphere is unstable on the geometric forming at much lower loads under the influence of the "dead" surface loads. In case of the action of "follower" loads, the assumed pressure value on the surface of the sphere is comparable with the value of the critical load of "internal" instability. In these cases, due to the instability of the equilibrium state, propagation of homogeneous deformations becomes uneven in the sphere. Moreover, the elastic waves with actual velocity cannot propagate in such conditions in solid medium. Violation of these fundamental conditions of mechanics required in determining the physical and mechanical properties of the medium should be taken into account in the integrated interpretations of seismic and laboratory (experimental) data. In this case, application of the linear theory of elasticity and elastic waves does not ensure the reliability of results on the structure and composition of the Earth's core despite compliance with the required integral conditions on the mass, moment of inertia and natural oscillations of the Earth.