• Title/Summary/Keyword: Physical property test

Search Result 297, Processing Time 0.034 seconds

A Study of the Effect of Structured Rehabilitation Education on the Stress of the Family with Stroke Patients (구조화된 재활교육이 뇌졸중환자 가족의 스트레스에 미치는 영향)

  • Kim, Byung-Eun;Lee, Jung-Min;Lee, Hyang-Yeon
    • Journal of East-West Nursing Research
    • /
    • v.1 no.1
    • /
    • pp.22-39
    • /
    • 1997
  • Purpose: The purpose of this study is to evaluate the effect of rehabilitation education on the reduction of the stress of family members who have patients suffering from stroke and to find a new way to nurse the patients and their family. Subjects & Methods: The subjects were sixty-one family members with the patients who had been hospotalized in K hospital of oriental medicine from september the 9th, 1996 to september the fourteen, 1996. This study was performed by simulated control group pretest-posttest design; pretest was done on the control group through a questionnaire, counselling and observation while posttest was done on the experimental group 1-2 days after systemic rehabilitation education. To teach the patients and their family, the amended version of a book written by Lee Hae-jin was used as a tool for systemic rehabilitation education. As a method to estimate ADL score, modified Kang's method was applied and ADL score was measured by well-trained technician. As for the tool to estimate the degree of family stress, Choi's method adjusted to this study was applied. In the analysis of the data, social property of the patient and the characteristic of the disease were surveyed in $X^2$ examination to confirm the consistency between the experimental group and the control group. The diffrence in the degree of the stress, which is a dependent factor, was examined by t-test. The difference in ADL score between the experimental group and the control group was examined by t-test. The difference in the degree of the stress according to the general feature of the family with stroke patient, social property of the patients and the characteristic of the disease were surveyed by F examination. The difference in family stress according to the degree of ADL was surveyed by F examination. RESULTS: 1. After hypothetically-examined systemic rehabilitation education, the total of the score of family stress surveyed in 34 items of three domains was compared between the experimental group and the control group. There was no statistically significant difference between two groups; mean score of experimental group=2.28, that of control group=2.93(t=.17, df=59, p=. 66). 2. In the survey on family stress in 34 items, the items over mean score 3.0 were firstly the anxiety of possible disability and relapse of the disease and secondly to watch the patient's suffering without doing anything in the domain of the change of the disease and the difficulty in caring. And the items of the lowest stress with less than mean 2.0 score were little chance to meet the relative and friends, inconsistent treatment and attitude of the medical workers and the change of the attitude of the relative due to the patient orderly in the domain of social and personal relation and the responsibility as the family. The items which showed the difference between two groups were aggravation of neighboring patient(t=3.36, df= 59, p=.001) and the possibility of patient's death(t=2.19, df=58.38, p=.033) in the domain of the change of the disease and the difficulty in caring. 3. In the study on the stress difference according to general features of the family with the stroke patient, the score of family stress with the occupation was higher with mean 2.49 than that of the family stress without occupation with mean 2.16, but there was no significant difference. (F=5.21, df=1/59, p=.026). 4. In the study on the stress difference according to social property of the patient and the characteristic of the disease, there was significant difference in the age of the patients (F=2.98, df=3/57, p=.039). These results show that even if there is no statistically significant difference between two groups, sixteen of the experimental group are less than 3.0 in ADL score(standard 6 score)while eight of the control group are less than 3.0 and that ten of the experimental group are in the year range of 39-49 while four of the control group are in the year range of 39-49 which showed significant difference in family stress. These imply that there is a possibility that the experimental group have serious and fundamental stress resulting in high pretest stress compared with the control group. It might be due to the characteristic of simulated control group pretest-posttest design that the psychologic-supportive effect by the education was not observed. On the basis of these results, the followings are suggested. 1) A study on the nursing-mediated method to reduce the stress in the items which are not resolved by rehabilitation education, a study on nursing according to the patient's age and a study on the supportive nursing toward the family with occupation are required. 2) More than two times consecutive nursing-mediated rehabilitation education to measure the family stress is required. 3) Comprehensive and multilateral systemic education program including the instruction on western-eastern medicine, physical therapy, exercise and diet through collaboration of the experts in each field is required. 4) Family stress at home as well as in the hospital needs to be estimated and home rehabilitation and home-nursing needs to be continued.

  • PDF

Studies on Physical Properties and Potential as Coffee Filter Application for Hanji According to Different Contents of Paper Mulberry Fibers (핸드드립용 커피필터 제품을 위한 닥섬유 혼합 비율에 따른 한지의 물리적 특성 및 적용 가능성 평가)

  • Woo, HyunJeong;Ju, YongChan;Park, SeongCheol;Lim, HyunA;Lee, HyunHee;Choi, JungWook;Song, HyukHwan;Lee, YounSuk
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.26 no.1
    • /
    • pp.33-39
    • /
    • 2020
  • The objective of this study was to evaluate the possibility for the coffee filter paper of Hanji. In this study, the samples for Hanji filter papers were prepared with three different mulberry fiber contents of 10, 30 and 50%(w/w). Surface brightness and apparent density of hand-made Hanji decreased with increasing mulberry fiber contents. However, values of thickness, tensile strength, wet tensile strength, burst strength, and folding endurance for hand-made Hanji increased by increasing the contents of mulberry fibers due to fiber-to-fiber bonding. The results of the coffee extraction test using the developed filter papers showed no significant differences between commercial filter paper and Hanji filter paper. Therefore, Hanji filter paper containing more than 30%(w/w) mulberry fiber may have potential uses for the dripped coffee filter application from a physical property point of view.

Study on the Physical Property of Thermal Curtains for Greenhouse (시설하우스용 보온커튼재의 물리적 특성에 관한 연구)

  • 장유섭;오권영;김승희;전종길;강금춘;정두호
    • Journal of Bio-Environment Control
    • /
    • v.5 no.1
    • /
    • pp.34-42
    • /
    • 1996
  • This study was conducted to investigate the physical and optical properties of polypropylene and polyester thermal curtains, in which tensile strength, heat reservance and light transmission of two different materials were measured. The results from this study are as follows. 1. The tensile weight of different materials were ranged from 3.4kg to 13.4kg, according to the thickness of materials, but that no difference in the tensile strength was appeared between the two materials. The Elongation of polypropylene materials and the tensile weight and strength of polyester materials were greater than any other materials. 2. The light transmittances of two materials were ranged from 50.3% to 81.7 %, light transmittances in polypropylene were higher by 20-30%,than those in polyester. 3. The heat reservances of two materials were ranged from 18.2% to 41.2%, in which polypropylene showed better performance than polyester. 4. From the results of the test, the polypropylene thermal material was better in elongation, heat reservances and light transmittances, but polyester thermal material was better in tensile strength and light isolation than the other material.

  • PDF

Rheological Properties of Bitumen for Reducing Negative Skin Friction (말뚝 부마찰력 저감용 역청재료의 유변학적 특성)

  • 박태순;윤수진
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.191-200
    • /
    • 2003
  • This paper presents the rheological properties of bitumen for reducing negative skin friction. The bitumen has been widely used due to both the cost and construction effectiveness. Also, it is well known that the use of bitumen for reducing negative skin friction renders the best results among other available methods. Three different modified bitumens were used for the testing programs. The physical tests include the penetration, the softening point and penetration index. The rheological tests include phase angle, complex modulus, creep tests and flow tests. The tests were conducted at four different temperatures(15, 30, 45 and 6$0^{\circ}C$) in order to simulate the field condition. The test results were analyzed using the phase angle, G$^*$/sin $\delta$, creep compliance and shear viscosity. The result of tests showed that the phase angle increased and G$^*$/sin $\delta$ decreased with the increase of temperature. The creep compliance increased as the loading time increased. The difference of the creep compliance is detected as the time and temperature are varied, however, the difference of the shear viscosity is not significant among the samples tested in this study. The rheological properties of the bitumen also showed that the physical testing method and the temperature dependant testing method are somewhat limited to showing and expressing the full rheological properties of the modified bitumen. The introduction of the time and the temperature dependent testing method is necessary to find out the full rheological properties of the modified bitumen.

Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process ($MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명)

  • Son, Hee-Jong;Hwang, Young-Do;Roh, Jae-Soon;Jung, Chul-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.753-761
    • /
    • 2005
  • In this study, pretreatment of organic matters with $MIEX^{(R)}$ was evaluated using bench-scale experimental procedures on four organic matters to determine its effect on subsequent UF membrane filtration. For comparison, coagulation process was also used as a pretreatment of UF membrane filtration. Moreover, the membrane fouling potential was identified using different fractions and molecular weights of organic matters. From the removal property of MW organic matters by coagulation process for the sample water NOM and AOM, the removal efficiency of high MW organic matters were much higher than those of low MW organic matters. It was shown that the removal efficiency of high MW organic matter more than 10 kDa was lower than that of low MW organic matter for $MIEX^{(R)}$ process. For the change of permeate flux by the pretreatment process, $MIEX^{(R)}$+UF process showed high removal efficiency of organic matter as compared with coagulation-UF processes, but high reduction rate of permeate flux was presented through the reduction of removal efficiency of high MW organic matter. From sequential filtration test results in order to examine the effect of MW of organic matter on membrane fouling, it was found that the membrane foulant was occurred by high MW organic matter, and the DOC of organic matter less than 0.5 mg/L was working as the membrane foulant. In the case of sample water composed of low MW organic matter less than 10 kDa, since the low MW organic matter less than 10 kDa has high removal efficiency by $MIEX^{(R)}$, low reduction rate of permeate flux is obtained as compared with coagulation-UF processes. In summary, it is required to conduct the research on physical/chemical characteristic of original water before pretreatment process of membrane process is selected, and a pertinent pre-treatment process should be employed based on the physical/chemical characteristic of original water.

A Study of the Factors influencing on Client's Violence in a Shelter for Teenage Runaway (청소년쉼터에서의 클라이언트 폭력에 영향을 미치는 요인)

  • Yoon, Suk Ja;Kim, Hee Jeong
    • Journal of Digital Convergence
    • /
    • v.11 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • This study attempt to explore how much characteristics of personal and institutional of staffs in shelter for teenage runaway influence to client's violence, and which factor of them are relative to client's violence. For this aims, we carried out a survey, survey subjects in shelter for teenage runaway participated in this research. T-test and variance analysis attempted to compare degree of violence experience of respondents by personal and institutional characteristics. According to result of analysis, age in the midst of personal characteristics is meaning difference and duty-time and type of shelter in the midst of institutional characteristics revealed meaning difference. Next, Multi-regression analysis tried to explore relative factor influencing on client's violence. The results, age in the midst of personal characteristics is relative with physical violence, duty-year in present institution is relative with etc harm. Also, duty-time per week of institutional characteristics is relative all with four type of violence. Type of shelter is relative with property harm, emotional violence and etc harm. Counseling time during duty is relative with physical violence. Above results provide basic data to find ways preventing client's violence to staffs in shelter for teenage runaway.

A Study on the Non-combustible Properties of High-density Fiber Cement Composites Mixed with Hemp Fibers (마 섬유 혼입에 따른 고밀도 섬유 시멘트 복합체의 불연 특성 연구)

  • Jang, Kyong-Pil;Song, Tae-Hyeob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.314-320
    • /
    • 2022
  • The function of reinforcing fibers used in building materials is to maintain resistance to bending loads and to function for cracking caused by drying shrinkage. High-density fiber-cement composites are mainly used for linear plates and are used to increase bending resistance. Therefore, tensile properties, bonding strength with cement hydrate, alkali resistance, and the like are required. Recently, as the non-combustible performance has been strengthened, a function to minimize the occurrence of sparks during high-temperature heating has been added. Therefore, the use of organic fibers is limited. In this study, a study was conducted to replace polypropylene used as reinforcing fiber with hemp fiber with excellent heat resistance. Hemp fibers have excellent heat resistance, good affinity with cement, and excellent alkali resistance. Based on the total volume of polypropylene fibers used in the existing formulation, the non-combustible performance was compared and evaluated by using hemp fibers instead of the polypropylene fibers, and basic physical properties such as flexural strength were tested. As a result of conducting a non-combustibility and physical property test using hemp fibers with a fiber length of 7 mm using 2 % and 3 % by weight, it was found that there is no remaining time of the flame, and the flexural strength can be secured at 95 % level of the existing polypropylene fiber.

Variation of Earth Pressure Acting on Cut-and-Cover Tunnel Lining with Settlement of Backfill (되메움토의 침하에 따른 개착식 터널 라이닝에 작용하는 토압의 변화)

  • Bautista F.E.;Park Lee-Keun;Im Jong-Chul;Lee Young-Nam
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.6
    • /
    • pp.27-40
    • /
    • 2006
  • Damage of cut-and-cover tunnel lining can be attributed to physical and mechanical factors. Physical factors include material property, reinforcement corrosion, etc. while mechanical factors include underground water pressure, vehicle loads, etc. This study is limited to the modeling of rigid circular cut and cover tunnel constructed at a depth of $1.0{\sim}1.5D$ in loose sandy ground and subjected to a vibration frequency of 100 Hz. In this study, only damages due to mechanical factors in the form of additional loads were considered. Among the different types of additional, excessive earth pressure acting on the cut-and-cover tunnel lining is considered as one of the major factors that induce deformation and damage of tunnels after the construction is completed. Excessive earth pressure may be attributed to insufficient compaction, consolidation due to self-weight of backfill soil, precipitation and vibration caused by traffic. Laboratory tunnel model tests were performed in order to determine the earth pressure acting on the tunnel lining and to investigate the applicability of existing earth pressure formulas. Based on the difference in the monitored and computed earth pressure, a factor of safety was recommended. Soil deformation mechanism around the tunnel was also presented using the picture analysis method.

Physical and Mechanical Properties of Magnesium Oxide Matrix depending on Addition Ratio of Magnesium Chloride (염화마그네슘 첨가율에 따른 산화마그네슘 경화체의 물리 및 역학적 특성)

  • Kim, Heon-Tae;Jung, Byeong-Yeol;Lee, Sang-Soo;Song, Ha-Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.4
    • /
    • pp.308-313
    • /
    • 2014
  • Recently, for longevity of resident building, the main trend is that the change of the inside space organization of resident building from wall construction to rhamen construction, which resulted in increase in use of lightweight composite panel. Thus, in this study, authors analyzed the engineering property of oxide of magnesium depending on the magnesium chloride addition ratio. The results of this research is expected to contribute on providing a fundamental material for the surface materials of lightweight composite panel. As the result of the experiment, as fluidity increased, air content decreased and initial set and final set as the magnesium chloride addition ratio increase. In the aspect of flexural strength and compressive strength, the test specimen showed the highest strength at 40% of the magnesium chloride addition ratio. At 20% of the magnesium chloride addition ratio, the test specimen showed the lowest water absorption rate. As the magnesium chloride addition ratio increases, the expansibility tends to increase as well in the aspect of shrinkage strain. After observing microstructure, we can see hydration products in the form of needle. It appeared high flexural strength because the hydration products have mineral fibrous tissue shape, which also contribute to the cause of the expansibility.

Flame Retardancy and Physical Properties of Ethylene Vinyl Acetate/Aluminum Trihydroxide Composites (에틸렌 비닐아세테이트/수산화알루미늄 복합재료의 난연 및 물리적 특성)

  • Lee, Minho;Yu, Dayeong;Kim, Yeongho;Lee, Sunghee;Kim, Jeong Ho;Lee, Young Chul
    • Polymer(Korea)
    • /
    • v.39 no.3
    • /
    • pp.433-440
    • /
    • 2015
  • Aluminum trihydroxide (ATH) has been commonly employed as a flame retardant for ethylene vinyl acetate (EVA) copolymers. In the present work, ATH was obtained from a recycling process of multi-layer packaging film wastes. EVA/ATH composite samples were prepared using a two roll-mill and flame retardancy of EVA/ATH composites were examined using limiting oxygen index (LOI) and flame retardancy test (UL94). We observed excellent flame retardancy in case of adding 150 phr or more of recycled ATH to EVA. Particle size and specific surface area play crucial roles in LOI value and UL-94 classification of the EVA/ATH composites. Smaller particle size and higher specific surface area of ATH was found out to improve the flame retardancy. Regarding tensile properties, crosslinked EVA/ATH compounds which is practically used for electric cables had similar to or even better tensile property values than the ones without ATH.