• 제목/요약/키워드: Physical function evaluation

검색결과 430건 처리시간 0.026초

경련성과 무정위성 뇌성마비 아동의 Jebsen Hand Function Test에 의한 손기능 평가 (Assessment of Hand Function in Spastic and Athetoid Cerebral Palsied Children by Jebsen Hand Function Test)

  • 이규리;이미자
    • 대한물리치료과학회지
    • /
    • 제3권2호
    • /
    • pp.981-987
    • /
    • 1996
  • Hand function evaluations are an important element of the assessment process in physical rehabilitation settings. The purpose of this study was to investigate hand function evaluation. Subjects consisted of 20 with spastic cerebral palsy(mean age = 9.8, SD = 1.6) and 20 with athetoid cerebral palsy(mean age = 9.6, SD = 2.3). Two groups of subjects were tested twice(pretest and posttest) by the JHFT to measure evaluations of hand function. These findings suggest that on four subtests - writing, card turning, large heavy objects and Stacking Checker-the spastic cerebral palsy perform significantly faster than athetoid cerebral palsy. But there were no significant differences between the pretest and posttest in spastic and athetoid cerebral palsy. To see the statistical differences in the experimental results was done using origin V. 3.0.

  • PDF

QFD를 이용한 식기세척기의 감성기반 사용성 평가 연구 (A Study on Usability Evaluation with QFD on Customers' Sensation of Dishwasher)

  • 진범석;최계연;지용구;조길수;김경록;이창희
    • 대한인간공학회지
    • /
    • 제26권3호
    • /
    • pp.101-109
    • /
    • 2007
  • This research is for developing a usability evaluation model based on customer sensation using Quality Function Deployment, which evaluates the relationship between consumer sensation and usability among the physical design factors of dishwashers. Four aspects of the evaluation model; overall sensation factors, detail sensation factors, usability evaluation factors and physical design factors of products were analyzed in three sequential processes of QFD. The sensation evaluation factors and the usability evaluation factors were created from regression analysis of the results of the sensation and usability test. Moreover, thirty-one physical design factors selected through group discussion of ergonomist and manufacturers. Among them, 19 physical design factors according to priority were applied to evaluation model using QFD. With the evaluation model using four aspects, physical design factors influencing user sensation were generated. These factors were 'alarm sound', 'dishwasher size', 'button size' and 'display size'. Consequently, the degree of influences was tested. Design guidelines for dishwashers were derived from finally generated physical design factors.

Correlationship among Smartphone Screen Time, Cervical Alignment, and Muscle Function in University Students

  • Hyungyu Cha;Seonyoung Hwang;Jinyoung Eo;Hyein Ji;Jiwon Han;Wonjae Choi
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.446-453
    • /
    • 2022
  • Objective: The popularization of smartphones can lead to abnormal cervical alignment in university students. The aim of this study was to investigate the relationship among smartphone screen time, cervical alignment, and muscle function in university students. Design: Cross-sectional study. Methods: Seventy-five university students participated in the study. They completed the evaluation of cervical alignment and muscle function, such as handgrip strength, proprioception, and muscle quality (tone, stiffness, and relaxation time). All participants recorded their general characteristics and individual smartphone screen time before the evaluation. They were evaluated craniovertebral angle (CVA) using smartphone application (angle meter 360) for measuring cervical alignment. The muscle function was assessed using a digital hand-held dynamometer, dual inclinometer, and MyotonPRO device. Results: Of all participants, twenty-five university students had forward head posture (CVA<49°, 33.33%). Independent t-test revealed that there were significant differences on smartphone screen time, muscle stiffness, and muscle relaxation between the participants with and without forward head posture (p<0.05). There were significant correlations between the smartphone screen time and the CVA, muscle tone, and muscle relaxation (r=-0.493, 0.250, and -0.500, respectively). Conclusions: The results indicate that the university students with forward head posture had high smartphone screen time and muscle stiffness compared to the students without forward head posture, and smartphone screen time might be associated with cervical alignment and muscle quality.

수단-목적 사슬 이론을 이용한 의복품질 평가과정에 잔한 이론적 연구 (Apparel Quality Evaluation Process bused on Means- Bnd Chain Theory: A Theoretical Study)

  • 오현정;이은영
    • 한국의류학회지
    • /
    • 제22권4호
    • /
    • pp.452-459
    • /
    • 1998
  • The purpose of this study was to discover a conceptual framework and evaluation process of apparel quality by means-end chain theory. The theoretical study was conducted to find out a conceptual framework and build a hypothetical evaluation process model of apparel quality. Apparel quality was perceived associative network called a means-end chain and was evaluated in several stages. A conceptual framework of apparel quality evaluation was organized into hierarchical relationships among four different dimensions: physical attribute, physical function, instrumental performance, and expressive performance. The means-end structure linked tangible physical attributes and function to more abstract instrumental and expressive performance. A hypothetical evaluation process model linked dimensions of apparel quality to the selected means-end relationship. Different consumers had different means-end chains for the same apparel. Therefore different subjects are likely to have different evaluation paths. From this study we can suggest an evaluation process model of apparel quality.

  • PDF

척수손상환자에서 보행 기능 평가도구인 WISCI II의 타당도와 신뢰도 (Validity and Reliability on the Walking Index for Spinal Cord Injury in the walking assessment of the SCI patient)

  • 이형수;정찬주;양회송;신영일
    • The Journal of Korean Physical Therapy
    • /
    • 제16권3호
    • /
    • pp.142-151
    • /
    • 2004
  • The purpose of this study was to determine the validity and the reliability of the WISCI II to ascertain its value in the walking function evaluation of spinal cord injury patient. The WISCI II consists of 20 variables with a total valus ranging from 6 to 20 score. A group of 23 spinal cord injury patient were included in this study. To determine the validity, kappa statistics between the WISCI II and SCIM II were measured. The result of this study are as follows: 1) In the validity study, the kappa statistics between the WISCI II and SCIM II were 0.79 and 0.84 for an initial total score and a discharge total score respectively, indicating a reasonable agreement between the two test. 2) In the reliability study, the Cronbach's alpha coefficient was 0.83 and 0.95 for total score indicating a good internal consistency. The finding suggest that the WISCI II demonstrated an acceptable validity and reliabilit for the evaluation of walking function capacity of spinal cord injury patient in clinical practice.

  • PDF

Assessment of speckle image through particle size and image sharpness

  • Qian, Boxing;Liang, Jin;Gong, Chunyuan
    • Smart Structures and Systems
    • /
    • 제24권5호
    • /
    • pp.659-668
    • /
    • 2019
  • In digital image correlation, speckle image is closely related to the measurement accuracy. A practical global evaluation criterion for speckle image is presented. Firstly, based on the essential factors of the texture image, both the average particle size and image sharpness are used for the assessment of speckle image. The former is calculated by a simplified auto-covariance function and Gaussian fitting, and the latter by focusing function. Secondly, the computation of the average particle size and image sharpness is verified by numerical simulation. The influence of these two evaluation parameters on mean deviation and standard deviation is discussed. Then, a physical model from speckle projection to image acquisition is established. The two evaluation parameters can be mapped to the physical devices, which demonstrate that the proposed evaluation method is reasonable. Finally, the engineering application of the evaluation method is pointed out.

뇌성마비 아동의 신체 기능수준과 재활 목적 치료 강도가 신체 기능향상에 미치는 영향: 6개월간 추적연구 (The Effects of Physical Function Level and Intensity of Treatment for Rehabilitation on Improvement of Physical Function in Children with Cerebral Palsy: Follow-up Study for 6 Months)

  • 김부영;윤영주;신용범;김수연;오태영
    • 대한물리의학회지
    • /
    • 제13권1호
    • /
    • pp.27-38
    • /
    • 2018
  • PURPOSE: The purpose of this study was to find out the treatment patterns of Children with cerebral palsy, and to analyze the effect of physical function level and treatment intensity on improvement of physical function in children with cerebral palsy for six months. METHODS: Participants were 126 children (boys 83, girls 43) diagnosed cerebral palsy that the mean age was at 33months, ranged from 8 months to 77 months. We collected data related on demography and disable characteristic, treatment pattern using by questionnaire constructed ourselves for six months on caregivers. The treatment pattern includes, type, frequency, and institute of treatment. We performed the evaluation of Gross Motor Function Measurement (GMFM) and Pediatric Evaluation of Disability Inventory (PEDI) between pre and post for six months in order to find out improvement of physical function. We analyzed the effect of physical functional level measured by Gross Motor Functional Classification system, age, treatment intensity on physical function using by repeated measures ANOVA for SPSS PC ver. 22.0. RESULTS: The average of treatment frequency for physical therapy was 5.74 times per week, occupational therapy was 3.96 times, speech therapy was 2.96 times, treatment for accompanying disability was 3.12 times. Physical function level and age was significantly factors affecting improvement of physical function, there was no significant difference according to treatment intensity. CONCLUSION: We suggest that physical function and age might be important factors on improvement of physical function and professional rehabilitation team must consider the appropriate treatment type customized to each children.

뇌성마비 아동에서 기능분류체계와 소아장애평가척도의 기능적 기술 사이 관련성 (Relationship Between Function Classification Systems and the PEDI Functional Skills in Children With Cerebral Palsy)

  • 박은영;김원호
    • 한국전문물리치료학회지
    • /
    • 제21권3호
    • /
    • pp.55-62
    • /
    • 2014
  • This study investigated the relationship between function classification systems and the Pediatric Evaluation of Disability Inventory (PEDI) functional skills in children with cerebral palsy (CP). Two hundred and eleven children with CP participated in this study. The Korean-Gross Motor Function Classification System (K-GMFCS), Korean-Manual Ability Classification System (K-MACS), Korean-Communication Function Classification System (K-CFCS), and self-care, mobility, and social function domains of the Korean-Pediatric Evaluation of Disability Inventory (K-PEDI) functional skills were measured by physical therapists or occupational therapists. All of the function classification systems were significantly correlated with PEDI functional skills ($r_s$=-.549 to -.826) (p<.05). Especially, K-GMFCS, K-MACS, and K-CFCS were correlated significantly with mobility, self-care, and social function, respectively. Using stepwise multiple regression analysis, we established that K-GMFCS, K-MACS, and K-CFCS were predictors of self-care skills (74.3%) and mobility skills (79.5%) of the K-PEDI (p<.05). In addition, K-CFCS and K-MACS were predictors of social function (65.9%) of the K-PEDI (p<.05). The information gathered in this study using the levels measured in the function classification systems may be useful to clinicians for estimating the PEDI functional skills in children with CP.

상지사용 선수들의 어깨관절기능에 관한 문헌연구 (Literature Study About Shoulder Joint Function of Overhead Players)

  • 김인섭;이병권;조미숙;장철;배성수
    • 대한물리의학회지
    • /
    • 제2권1호
    • /
    • pp.65-72
    • /
    • 2007
  • Purpose : The purpose of this study is a research on the evaluation about shoulder joint function. Methods : It's based on the reference books. Result : Shoulder joint has the biggest ROM in human body, and it is a joint that stability and mobility are required at the same time sport art. Especially, function of shoulder joint than other what item players of more important overhead item correct diagnosis and evaluation for shoulder joint injury require. Measurement equipment for shoulder joint is helping a lot of incorrect diagnosis and analysis about shoulder joint function of overhead players through a lot of developments. Conclusion : I think a lot of helps torture in motor ability elevation of players and player protection as analysis by special quality in item of overhead players.

  • PDF

Study of runout-motion in body physical techniques: physical index and sensory index

  • Kim, Jeong-lae;Shin, Kyu-ok
    • International journal of advanced smart convergence
    • /
    • 제5권3호
    • /
    • pp.56-60
    • /
    • 2016
  • Body physical technique is to pursuit the dynamic motion by the physical index(PI) and sensory index(SI) on the physical body function. Function of the physical body by the motor condition is organized the dynamic physical system. For the physical motion of signal, we is defined a runout value of the body function by the physical index on the dynamic state. The concept of body physical index was identified the reference of physical index and sensory index by the body technique. As to detect a variation of the body physical technique-runout physical index(BPT-RPI) of the maximum and average and minimum in terms of physical motion, and the dynamic sensory value that was a runout function of the vision variation of the $Vi-{\xi}_{MAX-AVG-MIN}$ with $2.53{\pm}4.85$ units, that was a runout function of the vestibular variation of the $Ve-{\xi}_{MAX-AVG-MIN}$ with ($-0.69{\pm}2.32$)units, that was a runout function of the somatosensory variation of the $So-{\xi}_{MAX-AVG-MIN}$ with ($-1.43{\pm}-1.36$) units. The dynamic physical motion will be to confirm at the variable function of the runout motion for the body function values of dynamic physical index on the BPT-RPI that was identified an evaluation of the physical sensory function by the dynamic physical system. Runout body system was mentioned of a physical body situation by the mild moving and was refer a runout data of dynamic physical nervous index.