• 제목/요약/키워드: Physical conditioning

검색결과 180건 처리시간 0.028초

여름철 수면시 온열쾌적감 평가 - 제1보 : 수면 전후 설문에 관하여 - (Evaluation of Thermal Comfort during Sleeping in Summer - Part I : On Results of Questionnaire Before and After Sleep -)

  • 김동규;금종수
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.404-409
    • /
    • 2005
  • This study is to investigate effects of thermal conditions on sleep. Five female university students participated in the sleep experiment. Three temperature levels (22, 26, and $30^{\circ}C$) were given, and relative humidity was maintained to $50\%$. When as subject arrived in the chamber at 9 o'clock in the evening, questionnaire was given to check physical and psychological conditions. After checking conditions, subjects went to bed till 07 : 30 in the morning. Body movement was checked during sleeping. After sleep in the chamber, questionnaire was given to the subject in order to check sleep quality. Subjects evaluated sleep quality by themselves by answering the time they fall asleep and wake up, frequency of wake during sleep, causes of each waking, and feeling after sleep. Sleep quality was rated with 7-point scale. At $30^{\circ}C$ condition, body movement was significantly higher than of other thermal conditions. The best sleep quality was obtained at the $26^{\circ}C$ condition, while the worst sleep was taken at the $30^{\circ}C$ condition.

R-22 and R-410A Condensation in Flat Aluminum Multi-Channel Tubes

  • Kim, Nae-Hyun;Min, Chang-Keun;Jung, Ho-Jong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권3호
    • /
    • pp.114-124
    • /
    • 2003
  • In this study, condensation heat transfer tests were conducted in flat aluminum multi-channel tubes using R-410A, and the results are compared with those of R-22. The flat tubes have two internal geometries; one with smooth inner surface and the other with micro-fins. Data are presented for the following range of variables; vapor Quality (0.1∼0.9), mass flux (200∼600 kg/$m^2$s) and heat flux (5∼15 kW/$m^2$). Results show that the effect of surface tension drainage on the fin surface is more pronounced for R-22 than R-410A. The smaller Weber number of R-22 may be responsible. For the smooth tube, the heat transfer coefficient of R-410A is slightly larger than that of R-22. For the micro-fin tube, however, the trend is reversed. Possible reason is provided considering physical properties of the refrigerants. For the smooth tube, Webb's correlation predicts the data reasonably well. For the micro-fin tube, the Yang and Webb model was modified to correlate the present data. The modified model adequately predicts the data.

삼중 혼합 냉매 R407C의 핵비등 열전달 특성에 관한 실험적 연구 (An experimental study on nucleate boiling of ternary refrigerant R407C)

  • 김성훈;곽경민;배철호;정모
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.276-283
    • /
    • 1997
  • The nucleate boiling heat transfer experiments are performed using a ternary refrigerant R407C which is a candidate of alternatives of HCFC 22. The boiling phenomena for R-32, R-125, and R-134a which are the constituent refrigerants of R407C are also investigated to give the foundation of theoretical research for the mixture component boiling. The nucleate boiling heat transfer coefficients of R407C is less than those of HCFC 22 which has the similar physical and transport properties. Since the experimental results show the deterioration of boiling heat transfer coefficients of ternary mixture refrigerants R407C, the boiling heat transfer coefficients of R407C cannot be obtained by the linear combination of boiling heat transfer coefficients from its constituent components R-32, R125, and R134a.

  • PDF

에어컨디셔너의 냉매배관을 연결하는 커플링의 유동해석 (Flux Analysis of Air-conditioner Coupling)

  • 이수열;김우승;조수;성욱주;박희문;심경종
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.1031-1036
    • /
    • 2009
  • This study is intended to identify how quick disconnect coupling which connects with refrigerant piping of air-conditioner using R-22 refrigerant has effect on characteristics of flux. in the case where the air-conditioner installs utilizes quick disconnect coupling, COP has an effect on the quantity of cooling load because of changing flow rate and physical properties of refrigerant which flow into an entrance of expansion valve from coupling. Variation of flow rate can be regulated by changing expansion-contraction angle; $\alpha$ of an entrance and an exit of coupling. In this study, quick disconnect coupling is presented flow of coupling by using FLUENT as heat flow program. To have an effect on the expansion entrance valve, and by changing expansion-contraction angle; $\alpha$ of an entrance and an exit

  • PDF

수직으로 설치된 비균질 평판 단열재용 성능시험장치 개발 (Development of Thermal Performance Tester for Non-Homogeneous Insulation Pannels Installed Vertically)

  • 오홍영;송기오;전현익;조선영
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2016
  • In case of metal insulation, which is produced by stacking stainless steel sheets and air layers in a multi-stack manner at a specific thickness, insulation performance will be evaluated based on thermal transmittance rather than the intrinsic physical properties of each material such as thermal conductivity. However, there is no standard for measuring thermal transmittance targeted for non-homogeneous insulation which is used in relatively high temperature conditions such as a power station. In this study, the thermal conductivity of homogeneous insulation acquired by the standardized guard hot plate method and the thermal conductivity of homogeneous insulation measured by the newly developed performance tester were compared to verify the confidence level of the tester. As a result, thermal conductivity acquired by the newly developed thermal transmittance tester was about 6% higher than the thermal conductivity measured by the existing guard hot plate method under the anticipated service temperature conditions.

지역난방 공동주택에 설치하는 급탕 2단 열교환기의 용량 적정성 평가에 관한 연구 (Design Capacity Evaluation of 2-stage Hot Water Heat Exchanger in Apartment Mechanical Rooms with District Heating System)

  • 정광섭;사기용;김래현;이훈
    • 설비공학논문집
    • /
    • 제21권8호
    • /
    • pp.456-461
    • /
    • 2009
  • Recently, an increasing interest in district heating system has emerged rapidly, In this paper, the physical measurements and data to be monitoring through the internet were carried out with regard to hot water heating energy consumption at the three apartment housings with district heating system in Sang-am district of Seoul, Korea, Measurements were made of the thermal factors such as the pressure of heating pipe, flow rates, hot water temperature and etc, The objective of this study is to compare the design capacity of reheat exchanger with that of preheat exchanger in order to evaluate for the number of plates of two exchangers to be distributed properly.

인체모델을 고려한 자동차 실내의 에어컨 토출구 위치 변화에 따른 냉방성능 및 온열쾌적성 평가 (Evaluation of Thermal Comfort and Cooldown Performance inside Automotive Cabin according to Air-conditioning Vent Location)

  • 서진원;박재홍;최윤호
    • 한국자동차공학회논문집
    • /
    • 제20권5호
    • /
    • pp.120-129
    • /
    • 2012
  • As the recent advancement of automobile industry, there has been a great interest in the thermal comfort of the passengers inside the cabin of an automobile. Thermal comfort is affected by temperature, velocities, and mean radiation temperature of air, thermal resistance of clothes and physical active level of human. The present study performed computational analysis to select the location of air-conditioning vent that improves thermal comfort inside the cabin. In order to do this, we considered various air vent positions, and thermal flow analysis of each case is performed using CFD for the cabin with four passengers. The thermal comfort is evaluated using the computational results and the optimum location of air vent is suggested.

보일러 Windbox내 공기공급 계통의 유량분포 해석 (Analysis of Air Distribution in the Windbox System of the Utility Boiler)

  • 박호영;김성철
    • 설비공학논문집
    • /
    • 제20권9호
    • /
    • pp.581-589
    • /
    • 2008
  • The pulverized coal combustion behavior in the utility boiler is very complex since so many physical and chemical processes happen in it, simultaneously. The mixing of pulverized coal with combustion air plays an important role in achieving the efficient combustion and stable boiler operation. The distribution of combustion air supplied to the furnace through the windbox damper system has not been clearly known since the individual measurements of air flow for each air nozzle were not possible, yet. The present study describes the CFD modelling of windbox damper system and aims to obtain the air flow rates and pressure loss coefficients across the present five damper systems, respectively. The one dimensional flow network model has been also established to get air flow distributions across the windbox damper, and applied to the actual plant operation condition. Compared with the designed air flow distribution, the modelled one gives a reasonable agreement. For the actual plant operation, the predicted air flow distribution at each air nozzle is differed with the designed data and strongly affected by the individual opening angle.

성층화된 축열조의 1차원모델에 대한 해석적인 해 (Analytical Solutions to a One-Dimensional Model for Stratified Thermal Storage Tanks)

  • 유호선;박이동
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.42-51
    • /
    • 1995
  • In order to establish a theoretical basis for the analyses of transient behaviors in stratified thermal storage tanks, analytical approaches to an improved one-dimensional model are made. In the present model the storage tank is treated as a finite region with an adiabatic tank exit, whereas it has been considered as a simple semi-infinite region previously. Application of the Laplace transformation and the Inversion theorem to the governing equations makes it possible to obtain an exact infinite-series solution, which is convergent only at sufficiently large time. Accordingly a complementary solution which is available for short times, i.e., the time range of this study is sought by an approximate method. The approximate solution which is rigorously validated through the examination of neglected terms in the solution procedure agrees quite well with the exact one. Moreover, it is simpler to use and more convenient to interpret the physical meaning of the solution. Comparison of the present solution with the previous ones shows relatively large difference near the tank bottom, which results from the more realistic boundary condition adopted in the present model. Some representative results by the approximate solution including effects of the Peclet number on temperature distrbutions are illustrated to show the utility of this study. In consequence, it is expected that the present results based on the improved model replace the foregoing ones as a new theoretical reference for studies of thermal stratification fields.

  • PDF

폴리감마글루탐산의 동결 건조 과정의 실험적 연구 (An Experimental Study on the Freeze Drying Process for Poly γ Glutamic Acid)

  • 강지수;심연호;변시예;장영수;강병하
    • 설비공학논문집
    • /
    • 제27권12호
    • /
    • pp.645-651
    • /
    • 2015
  • This paper presents an experimental study on the freeze drying process for poly ${\gamma}$ glutamic acid. The physical properties of poly ${\gamma}$ glutamic acid are measured during the freeze-drying process. The moisture contents of poly ${\gamma}$ glutamic acid according to the glass transient temperature are obtained by DSC (Differential Scanning Calorimetry) analysis. The end point of primary drying for the poly ${\gamma}$ glutamic acid with a thickness of 3 mm is obtained by measuring the thickness of the dried layer, the amount of moisture evaporation, the moisture content, and the pressure in the drying vacuum chamber during the freeze-drying process. By considering the variation in the glass transient temperature with respect to the moisture content of the material, a control schedule for the heating plate temperature is suggested during the secondary drying process.