• 제목/요약/키워드: Physical conditioning

검색결과 180건 처리시간 0.027초

The correlation between the physical power of golf players and the Titleist Performance Institute Level 1 test

  • Kim, Jaeeun;Yim, Jongeun;Do, Kwangsun
    • Physical Therapy Rehabilitation Science
    • /
    • 제7권1호
    • /
    • pp.13-17
    • /
    • 2018
  • Objective: This was a correlation study for predicting the power to improve the distance of golf players and developing an effective power program. Design: Cross-sectional study. Methods: The subjects of this study were 24 healthy males and females in their 20s and 30s who were golf athletes living in Seoul and Gyeonggi-do. In the Titleist Performance Institute (TPI) Level 1 test, the twelve swing characteristics include components of stability, mobility, body conditioning ability, and balance. The power test consisted of a vertical jump (VJ) in order to examine the power of the lower body, the seated chest pass (SCP) was used to examine upper body power, and the sit up and throw (SUAT) was used to examine the power of the upper body and core for the TPI Level 2 test. Results: The results of this study showed that the 90/90 was correlated with VJ, SUAT, and SCP scores (p<0.05). Single leg stance was correlated with VJ, SUAT, over head deep squat, and bridge with leg extension were correlated with VJ (p<0.05). The toe touch was correlated with SUAT results (p<0.05). Conclusions: The results of this study showed that the TPI Level 1 test and power test were correlated with the performance of the golf players. Future studies have shown that fitness program development and further research are needed.

Efficacy of immune-strengthening functional drinks in top-level athletes: a questionnaire survey-based research

  • Lee, Minchul;Lee, Jin-Sook;Kim, Kyunghee;Kim, Chanju
    • 운동영양학회지
    • /
    • 제25권3호
    • /
    • pp.23-27
    • /
    • 2021
  • [Purpose] Functional beverages are intended to support those who want to maintain optimal physical condition and improve their quality of life through the enhancement of heart health, immunity, and digestion. The purpose of this study was to investigate the performance of top-level athletes consuming immune-strengthening conditioning nutritional drinks. [Methods] A total of 107 top-level athletes (baseball (56 players), pro volleyball (17), athletics (16), cycling (8), golf (6), and fencing (6)) participated in the experiment. They consumed an immune-enhancing functional beverage once a day for 8 weeks and responded to a survey before, during, and after drinking the beverage. [Results] Three total aspect-based subfactors were drawn from 24 questions in the factor analysis: physical, satisfaction with mental stability, and activity in performance. The physical, mental stability and performance changes of athletes significantly increased in period 2 (4 weeks after intake) and period 3 (after 8 weeks of intake). [Conclusion] We evaluated the efficacy of a new conditioned beverage containing Lactobacillus B240 and protein in improving the performance and physiological utility of top athletes. This functional drink may gain popularity among those seeking health benefits and improved exercise performance.

굴절률을 이용한 수용액의 빙충전율 측정 (Measurement of the Ice Packing Factor of an Aqueous Solution Using the Index of Refraction)

  • 백종현;정동열;강채동;홍회기
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.1088-1094
    • /
    • 2005
  • In the present paper, a new method is proposed for the measurement of the ice packing factor (IPF) of an ice slurry using the index of refraction. The purpose of the new method is to improve the resolution of the measurement and to increase its resistance to electric noise as compared to the standard IPF measurement technique that relies on measurement of the freezing temperature. These two methods are similar in that they both obtain a concentration of aqueous solution from measured physical quantities and calculate the IPF using a relation between concentration and IPF. We experimented and compared the two methods, whose results were also compared with results from the calorimeter method obtaining the IPF directly They are in good agreement (within $5\%$), which demonstrates the validity of the newly proposed method.

표면 연소기의 연소진동음의 발생조건 (Onset condition of the combustion-driven sound in a surface burner)

  • 권영필;이주원;이동훈
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.221-228
    • /
    • 1997
  • A strong combustion-driven sound from a surface burner made of a perforated metal fiber plate for premixed gas was investigated to clarify the physical mechanism of its generation. A simple model was developed for the acoustic power generation in terms of the heat transfer response function and the acoustic impedance of the burner. The acoustic impedance of the perforated metal fiber placed on the open exit was measured and the heat release response of the burner to the oscillating flow associated with the acoustic disturbance was expressed in terms of a response function. It was found that the power is generated by the heat release in response to the downstream particle velocity, in contrast to the upstream velocity in the case of the Rijke oscillation driven by a heater placed in the lower half of a columm with upstream flow. The measured frequencies of the oscillation were in agreement with the estimated resonance frequencies and their excitation was varied with the combustion conditions. For the same fuel rate, the excited frequency increases with the air ratio if it is low but decreases with the ratio if not so low. Such frequency characteristics were explained by assuming a heat release response function with a time constant and it was shown that the excited frequency decreases as the time constant increases.

  • PDF

미립잠열슬러리의 물성에 관한 실험적 연구 (Physical Properties of Microencapsulated Phase Change Material Slurries)

  • 이효진;홍재창;이재구
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.860-869
    • /
    • 2000
  • The thermal conductivity and density of slurries entrained with the particles of Micro-PCM are measured with respect to its temperatures as well as concentrations. For the thermal conductivity of slurries, a device made from P.A. Hilton (Model No. H470) is adopted. There is a well-scaled 0.3 mm gap between shells into which the slurry is injected. The temperatures of the slurry are changed to $5~25^{\circ}C$ , for which it is controled by the supplied voltage and cooling water circulated around the outer shell. The concentrations of Micro-PCM slurries are varied from 5 wt% to 50 wt%. Some general equations such as Maxwell's equation, are evaluated for their applicability with Micro-PCM slurry. As a result, it happens to be some 20% discrepancy between the experiment and the applied equations. The density measurements of Micro-PCM slurry to its temperature and concentration are peformed by hydrometer. For the experiment, tetradecane encapsulated slurry (($t_m≒6^{\circ}C$) and a mixed wax ($t_m≒50^{\circ}C$) are tested. The temperature changes of tetradecane are applied for $0^{\circ}C\;to\;$20^{\circ}C$and a mixed wax for $20^{\circ}C\;to\;$60^{\circ}C$ and its concentrations are changed from 5 wt% to 30 wt%. The results are compared with a general equation and the referenced data. For the conclusion, the experimental result and a general equation are well agreed.

  • PDF

미술관의 조명환경 변화에 따른 시각적 반응 및 피로감각 변화분석 (Influence of Luminous Environments on Visual Responses and Fatigue Sensation in Art Galleries)

  • 박윤혜;김수영
    • 설비공학논문집
    • /
    • 제23권1호
    • /
    • pp.61-72
    • /
    • 2011
  • The influences of luminous environment on visual responses and fatigue sensation in art galleries were examined in this study. Field measurements and survey were performed in three galleries under various illuminance and luminous conditions. Result implies that vertical illuminance on art paintings needed to be somewhere between 200 lx and 300 lx to avoid visual discomfort. The vertical illuminance difference between consecutive paintings should not exceed 100 lx to keep visually comfortable environment. Visual comfort sensations were related to glare, visual stimulus, reflection from paintings, illuminance variation, and the sensation that subjects can clearly see the paintings. The sensation of fatigue was significantly influenced by the changes of luminous element that caused visual stimulus and discomfort. The sensation of eye fatigue among physical fatigue was primarily influenced by the glare, visual stimulus and comfort. The psychological fatigue was also influenced by eye fatigue, visual comfort, brightness and satisfaction with color of light.

헬리컬관외 침전 및 적하 열전달 특성에 관한 연구 (Study on the Heat Transfer Characteristics of Immerged and Falling Flows on Helical Tubes)

  • 황승기;윤상국;김동혁;이승갑
    • 설비공학논문집
    • /
    • 제13권4호
    • /
    • pp.225-232
    • /
    • 2001
  • An experimental study is carried out to investigate the characteristics of heat transfer of outside helical tubes. The main heat exchanger consists of twelve curved columns with each 300mm diameter and the total length of 1.2m copper tube having an outer diameter of 19.05mm with 1.5mm thickness. Water flows down the outside of helical tube, where flow patterns are the vertical film falling flow, immerged flow, and mixed-flow which is the combination of film falling flow and immerged flow. Refrigerant 11 flow the inside of the tube countercurrently. The experimental range of inside flow rate is 1.7~3.2$\ell$/min and outside flow rate is 21-33$\ell$/min. The results are presented as Nusselt number with corresponding Reynolds number for variety of outside and inside flow rates. The heat transfer rates of the mixed flow are 8 to 56% higher than those of film falling flow or immerged flow only. Interpretation of the results is given on the basis of physical reasoning and the correlation equations.

  • PDF

고압의 포화수증기-비응축성 수소기체 혼합기 속에서 분무수적으로의 열전달을 예측 (Prediction of Heat Transfer Rates to Spray Water Droplets in a High Pressure Mixture Composed of Saturated Steam and Noncondensable Hydrogen Gas)

  • 이상균;조종철;조진호
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.337-349
    • /
    • 1991
  • Heat and mass transfer rates to spray water droplets for spray transients in a high pressure vessel have been predicted by two different droplet models: the complete mixing model and the non-mixing model. In this process, the ambient fluid surrounding the droplets is a real-gas mixture composed of saturated steam and noncondensable hydrogen gas at high pressure. The physical properties of the mixture are estimated by applying the concept of compressibility factor and using appropriate correlations. A computer program, DROPHMT, to calculate the heat and mass transfer rates for two different droplet models has been developed. As an illustrative application of the computer program to engineering practices, heat and mass transfer rates to spray water droplets for spray transients in a Pressurized Water Reactor (PWR) pressurizer have been calculated, and the typical results have been provided.

  • PDF

압축식 제습기에 대한 수치해석 연구 : (II) 열전달 (Numerical Analysis of A Compressor Type of Dehumidifier : (II) Heat Transfer)

  • ;;김규목;정재동
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.92-99
    • /
    • 2018
  • A numerical analysis of a compressor dehumidifier has been conducted focusing on the air side heat transfer, which is a part of a series research on the dehumidifier. The moving reference frame was applied to the fan modeling, and the porous model was used for the evaporator and condenser modeling. Curve fitting obtained the inertial and viscous resistances parameters to the results of the physical model of the unit cell with actual shape of a fin tube. The porous model was validated within a reasonable computation time for the range of practical inlet velocity of a dehumidifier. A parametric study has been conducted for fin number, fan speed (i.e., air flow rate), and evaporator/condenser tube arrangement. ANOVA analysis showed the dependency of each parameter on the velocity and temperature uniformity, which are desirable for high performance of the dehumidifier.

건축설비소음 평가를 위한 어휘의 유형화에 관한 연구 (A Research on Vocabulary Materialization for Evaluation of Architecture Plumbing Noise)

  • 유희종;정은정;김재수
    • 설비공학논문집
    • /
    • 제19권4호
    • /
    • pp.346-354
    • /
    • 2007
  • Recently, in accordance with the buildings are rapidly becoming to high-stories, large-sizes, and since the case that noise of equipment machinery, tool itself infringes the life environment is on increasing, this is becoming to the object of civil appeal. Accordingly, in order to set up a countermeasure against such equipment machinery noise, even a systemic evaluating method is required, up to now while the appraisal that considering on the physical characteristic only had been done, but the characteristic about subjective valuation was not reflected as yet. Therefore, in this research, through the 1st, 2nd Psycho-Acoustics Experiments, the 30 vocabularies were extracted for evaluation of the construction equipment noise. As the result of Element Analysis, the 3 Elements were extracted from these vocabularies, and it could be understood that these Elements have been trustfully selected. It is now considering that the extracted vocabularies as per the above result would be used to Psycho-Acoustic Evaluation on Equipment Noise, and Psycho-Acoustics Experiment.