• Title/Summary/Keyword: Physical conditioning

Search Result 181, Processing Time 0.025 seconds

Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory (생물안전밀폐시설에서 Multizone과 CFD 연동해석에 의한 실내기류 및 Influenza A 오염농도해석)

  • Hwang, Ji Hyun;Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.588-593
    • /
    • 2014
  • To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.

Indoor and Outdoor Concentrations of Air Pollutants in Beauty Shops at kwangju Area

  • Son Bu-Soon;Song Mi-Ra;Yang Won-Ho;Park Jong-An
    • Journal of Environmental Science International
    • /
    • v.15 no.2
    • /
    • pp.101-106
    • /
    • 2006
  • The work of hairdressers includes washing, coloring, bleaching, permanent waving, conditioning, and cutting hair. Hairdressers are subjected to a number of physical and toxicological hazards. The toxicological hazards are those resulting from exposure to a wide range of chemicals that are usually classified active processes. In this study, twenty beauty shops were selected to assess the exposure to indoor air pollutants such as VOCs and particulate matter $(PM_{10})$ during one month from September 1 to September 30, 2003. Indoor air quality of beauty shops might be worse by vehicle emissions because the beauty shops were generally located near roadways. Personal exposures to VOCs and $PM_{10}$ were related to indoor concentrations of beauty shops. According to the questionnaire, hairdressers complained of sore throat, eye irritation, and nervousness as physical symptoms. The measured mean concentrations of respiratory particulates were $30.5ng/m^3$ in indoor, $30.5ng/m^3$ in outdoor and $44.0ng/m^3$ on personal levels. The personal concentration was found higher than indoor and outdoor concentrations. The heavy metals mean concentrations were shown as indoor (Na>Zn>Cr), outdoor (Cr>Zn>Pb), and personal (Na>Cr>Zn) levels. Conclusively, customers as well as workers in the beauty shops might be highly exposed to air pollutants from indoor and outdoor sources. Therefore, proper management should be taken to improve the indoor air quality in beauty shops.

Noise Phobia-Induced Relative Polycythemia in a Dog (개에서 소리공포증에 의해 발생한 상대적 적혈구증가증 증례)

  • Kang, Min-Hee;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.494-497
    • /
    • 2012
  • A 6-year-old castrated male Miniature Pinscher dog was referred due to shaking, panting and inappropriate elimination during thunderstorms. The dog had noise phobia after a car accident two years ago. The intensity of the fear of noise, especially with thunderstorms, worsened during the past 3 months (thunderstorm season). Physical examination revealed hyperthermia, tachypnea (panting), mild tachycardia, and an elevated systolic blood pressure. Laboratory examination revealed mild polycythemia with a lower oxygen pressure and saturation. Based on the history, physical examination, and laboratory tests, the dog was diagnosed as a noise phobia concurrent with relative polycythemia. Treatment was initiated with behavior modification with desensitization, counter-conditioning, and medication. Music therapy was also used and appeared to be beneficial. Clinical signs including polycythemia are improved. This case indicates that relative polycythemia can be occurred by chronic mental stress, such as noise phobia in a dog.

The Study on the Monitoring of Temperature and Humidity in Public Utilization Facilities (다중 이용 시설에 대한 온.습도 모니터링에 관한 연구)

  • Choi, Man-Yong;Chae, Kyung-Hee;Kim, Ki-Bok;Kim, Su-Un
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1470-1475
    • /
    • 2009
  • Until now for the safety of structures and equipment monitoring technology to measure the amount of the physical, if that is the one, one-point or single-source target is one the most. Therefore, becoming more numerous and complex to measure the amount of physical measurement technology that is comprehensive and complex, multi-source concepts to the monitoring of a multi-sensing technology is required. Have the same characteristics of multi-source multi-use space such as a multi-structure of facilities/equipment is. The people's safety in a multi-use facility will be directly related to life and even a little carelessness can lead to large-scale disaster occurs because of several factors, risks and to manage detect in advance the development of an intelligent monitoring technology is essential. Therefore, this study shows that multiple structures/facilities to improve the quality of human life in research to maintain a safe and comfortable living space for multi-source intelligence to the development of monitoring technology to achieve that goal, and the ubiquitous sensor network system on the basis of the wireless transmission module, and multiple research facilities/equipment for the ultra-small sensors for health monitoring study was performed.

  • PDF

Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate (도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석)

  • Yeo, In-Ae;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.3
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

Sound Design to Improve the Quality of Noise from Home Appliances (가전 제품의 음질 향상을 위한 음설계 연구)

  • 주재만;이제원;오상경;이나경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1122-1127
    • /
    • 2003
  • For many years, engineers in the field of acoustics have used the A-weighted sound pressure level (SPL). Since they were interested just in a reduction of noise, the A-weighted SPL was considered good enough to quantify noise problems. This is reasonable because loudness is usually the most important parameter for most noise problems and A-weighted SPL is often reasonably well correlated with loudness. As the overall noise levels drop, however, other parameters become more important and must be considered, Advent of sound quality came from an understanding that A-weighted SPL only reflects the loudness of a sound. It is obviously impossible to characterize a complex sound with a single number. Although product mostly has revealed physical quantities created by the standpoint of engineers, consumers perceive and evaluate products on the non-physical characteristics, such as feelings, emotions, and experiences in different social and cultural situations. Especially, for the household appliances for instance air-conditioner or refrigerator, the sound is heavily related to the satisfaction of a customer who is a real user of the product and is very important factor to decide purchasing as well as visual design. Therefore, in this research, the general tendency of consumer's psychology was investigated for the appliances. And also, in order to obtain clear guidelines fur sound manipulation, the characteristics of the sound of air-conditioning systems and refrigerators were compared with competitors'. since it is important to overcome the discrepancy between engineering and marketing, the relevance of sound manipulation must be documented from the consumer's perspective. That is the reason why we conducted a consumer and marketing oriented study.

  • PDF

A Case Study on the Effect of Hypobaric-Hypoxic Intermittent Training on the Blood Constituents and Average Heart rate of Professional Handicapped Cyclists

  • Kim, Sang Hoon;Song, Young Wha;Kim, Hong Rae;Heo, Seo Yoon;Kim, Yong Youn
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.8 no.1
    • /
    • pp.1114-1121
    • /
    • 2017
  • The purpose of this study was to investigate the effects of hypobarichypoxic training program on competitive performance. This was done by observing their conditioning and measuring their blood constituents before and after a multi-staged intermittent training program, over 2 weeks. Three national handicapped cyclists were placed in a multi-leveled hypobaric-hypoxic (flat-4000 meter (m) high elevation) environment with consistent temperature and humidity ($23{\pm}2^{\circ}C$, $50{\pm}5%$) for 2 weeks. After the training, the blood constituents and average heart rate (HR) were measured and the following results were obtained. In all three athletes, there were no unique changes in red blood cell count, hemoglobin, and hematocrit, while there was a rise in the reticulocyte count. Observations of the difference in average HR during exercise at varying altitudes showed that athlete A had an average increase in the HR for the first 5 days at 2000 m. For athlete B, the comparison of the first and last training sessions at an altitude of 2000 m showed an HR increase of approximately 17%. For athlete C, there was a steady increase in the HR until day 7 of the training. As such, hypobaric-hypoxic training suggested that improvement of aerobic exercise performance in these athletes and it is recommended that there be a development for future training programs at high altitude, geared towards handicapped athletes of various disciplines.

Machine Learning Approach for Pattern Analysis of Energy Consumption in Factory (머신러닝 기법을 활용한 공장 에너지 사용량 데이터 분석)

  • Sung, Jong Hoon;Cho, Yeong Sik
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.8 no.4
    • /
    • pp.87-92
    • /
    • 2019
  • This paper describes the pattern analysis for data of the factory energy consumption by using machine learning method. While usual statistical methods or approaches require specific equations to represent the physical characteristics of the plant, machine learning based approach uses historical data and calculate the result effectively. Although rule-based approach calculates energy usage with the physical equations, it is hard to identify the exact equations that represent the factory's characteristics and hidden variables affecting the results. Whereas the machine learning approach is relatively useful to find the relations quickly between the data. The factory has several components directly affecting to the electricity consumption which are machines, light, computers and indoor systems like HVAC (heating, ventilation and air conditioning). The energy loads from those components are generated in real-time and these data can be shown in time-series. The various sensors were installed in the factory to construct the database by collecting the energy usage data from the components. After preliminary statistical analysis for data mining, time-series clustering techniques are applied to extract the energy load pattern. This research can attributes to develop Factory Energy Management System (FEMS).

Influence of a Pre- and Postconditioning Treadmill Exercise on Intracerebral Hemorrhage-induced Apoptotic Neuronal Cell Death in Rats

  • Ko, Il-Gyu;Shin, Mal-Soon;Sim, Young-Je;Kim, Chang-Ju;Lee, Sam-Jun
    • Korean Journal of Exercise Nutrition
    • /
    • v.13 no.2
    • /
    • pp.115-122
    • /
    • 2009
  • Intracerebral hemorrhage (ICH) is a common cause of stroke, and it occurs mainly in the striatum, thalamus, cerebellum, and pons. Physical exercise is known to ameliorate neurologic impairment induced by various brain insults. In the present study, the influence of pre-and post-conditioning of treadmill exercise on spatial learning ability, the lesion volume, and apoptotic neuronal cell death in the striatum following ICH in rats was investigated. ICH in the striatum was induced by injection of collagenase using strereotaxic instrument. The rats in the pre-exercise group were scheduled to run on a treadmill before ICH induction for 2 consecutive weeks. The rats in the post-exercise group were scheduled to run on a treadmill after ICH induction for 2 weeks. The rats in the pre-exercise and post-exercise group were scheduled to run on a preconditioning treadmill exercise 2 weeks before ICH induction until postconditioning treadmill exercise 2 weeks after ICH induction, except the day of surgery. For this study, radial arm maze task, Nissl staining, terminal deoxynucleotidyl transferase-mediated dUTP nick end labeling (TUNEL) assay, and immunohistochemistry for caspase-3 were performed. Our date showed that treadmill exercise suppressed the ICH-induced apoptotic neuronal cell death and decreased lesion volume in the stratum. Treadmill exercise also alleviated the ICH-induced impairment of spatial learning ability. Preconditioning treadmill exercise before the ICH insult and postconditioning treadmill exercise after the ICH insult showed similar effectiveness on the recovery of ICH. In this study, however, preconditioning exercise before the ICH insult and postconditioning exercise after the ICH insult showed the most potent effectiveness on the recovery of ICH.

Metabolic Rate Estimation for ECG-based Human Adaptive Appliance in Smart Homes (인간 적응형 가전기기를 위한 거주자 심박동 기반 신체활동량 추정)

  • Kim, Hyun-Hee;Lee, Kyoung-Chang;Lee, Suk
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.20 no.5
    • /
    • pp.486-494
    • /
    • 2014
  • Intelligent homes consist of ubiquitous sensors, home networks, and a context-aware computing system. These homes are expected to offer many services such as intelligent air-conditioning, lighting control, health monitoring, and home security. In order to realize these services, many researchers have worked on various research topics including smart sensors with low power consumption, home network protocols, resident and location detection, context-awareness, and scenario and service control. This paper presents the real-time metabolic rate estimation method that is based on measured heart rate for human adaptive appliance (air-conditioner, lighting etc.). This estimation results can provide valuable information to control smart appliances so that they can adjust themselves according to the status of residents. The heart rate based method has been experimentally compared with the location-based method on a test bed.