• Title/Summary/Keyword: Physical Thermal Environmental Factors

검색결과 43건 처리시간 0.581초

수위변동에 따른 갯벌의 물리적 환경특성의 변화 (Variation of Physical Characteristic of Tidal Flat's Environment by Water Level Change)

  • 박종화
    • 한국환경복원기술학회지
    • /
    • 제2권3호
    • /
    • pp.1-9
    • /
    • 1999
  • This paper described the results of the characteristics of the near-bottom flow and field analysis of the tidal flats sediment. It was the aim of this paper to grasp current flow of tidal flat's environment and influence factor for environmental change forecast of tidal flats. Field measurement of water velocity, water elevation, bed materials test, and temperature distribution of tidal flat were conducted. Thereafter, current flow, turbidity and temperature distribution of tidal flat sediment have been discussed. The field research results showed that the fluctuating velocity near the seabed before and after its appearance at low tide was strongly affected by the wind wave. The resuspension of the sea-bottom sediment took place with great intensity before and after the appearance of the seabed at low tide. Both the sea water level and the weather condition were a significant influential factors. Such as, temperature and turbidity just on the surface and the shallow layer of seabed sediments were varied largely with time and weather conditions, but that its deeper layers was almost constant. Temperature on the seabed sediments was strongly influenced by irradiance and water depth. The temperature variation of the tidal flat and the variation characteristics of the current flow and turbidity depend greatly on the inhabiting environment of the tidal flat benthic organism.

  • PDF

민감도 분석을 기반으로 한 시료의 동결 특성에 미치는 영향인자 분석 (Influencing Factors on Freezing Characteristics of Frost Susceptible Soil Based on Sensitivity Analysis)

  • 고규현;이장근;김민섭
    • 한국지반공학회논문집
    • /
    • 제36권8호
    • /
    • pp.49-60
    • /
    • 2020
  • 동상민감성 시료의 동상 거동을 평가하기 위해 완전히 결합된 열-수리-역학 연계해석을 수행하였다. 이를 위한 구성모델은 질량보존방정식, 에너지보존방정식, 힘평형방정식을 기반으로 유도되었다. 구성모델을 통해 간극수의 상변화, 간극수 유동 및 수반되는 기계적 변형 등 1차원 동결에 대한 다양한 물리적 현상을 정량적으로 고려할 수 있었다. 한편, 시료의 동상발생량 및 동상속도에 미치는 영향 인자들을 조사하기 위해 민감도 분석 연구가 수행되었다. 민감도 분석 결과에 따르면, 시료의 초기 간극비는 종속변수인 동상발생량과 동상속도에 독립적으로 큰 영향을 미치는 반면 흙 입자 열전도도 및 온도구배는 독립적으로 미치는 영향보다 두 변수 간 상호 작용을 통해 더 큰 영향을 미침을 확인하였다. 본 연구에서 고려된 인자들은 모두 동상발생량과 동상속도에 영향을 미치는 주요 인자이며, 표본시료의 동상민감성 여부를 결정하는 데에 활용될 수 있을 것이다.

도심재생하천 내 수리적 특성이 열환경 변화에 미치는 영향 평가: 청계천을 대상으로 (Impact Assessment on the Change of Thermal Environment, According to the Hydraulic Characteristic Urban Regeneration Stream: Cheonggyecheon Case Study)

  • 김정호;이주승;윤용한
    • 환경정책연구
    • /
    • 제14권2호
    • /
    • pp.3-25
    • /
    • 2015
  • 도심재생하천 내부의 수리적 특성이 열환경 변화에 미치는 영향을 알아보고자 하천의 물리적 구조와 수리적 특성, 기상요소, 온열환경을 분석하였다. 연구 대상지는 복원된 도시하천으로서 큰 의의를 가지는 청계천을 선정하였다. 유형은 물리적 구조별 녹피율의 차이에 따라 유형 I(0.0%)과 유형 II(20.2%)로 구분하였다. 여울이 끝나는 Ba지점에서 수온은 $0.2^{\circ}C$ 감소, 유속은 0.7~0.9m/s 증가, 용존산소량은 0.5~0.6mg/L 증가하였으며, 기온은 평균 $1.1{\sim}1.4^{\circ}C$ 감소, 상대습도는 평균 6.6~8.7% 증가, 풍속은 불규칙한 변화를 보였다. 습구흑구온도지수 분석결과, 유형에 따른 상류부의 하천 내부와 수면 외부의 값의 차이는 미비하였으나, 유형 I의 하류부에서 감소폭은 $0.3{\sim}0.6^{\circ}C$, 유형 II는 $0.8^{\circ}C$ 등이었다. 기온저감의 효과는 수직높이로 유형 I의 경우 120cm, 유형 II는 140cm까지 영향이 있었으며, 거리별 기온저감의 효과는 유형 I의 경우 여울이 끝나는 Ba지점 이후로 증가하였고, 유형 II의 경우 지속해서 감소하였다.

  • PDF

바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가 (Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System)

  • 김세환;박종일
    • 설비공학논문집
    • /
    • 제17권5호
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

기상청(氣象廳) 지온(地溫) 측정(測定) 토양(土壤)의 물리적(物理的) 성질(性質)과 겉보기 열확산(熱擴散) 계수(係數) 산정(算定) (Physical Properties and Apparent Thermal Diffusivity of the Soils where Soil Temperature is Measured Regularly)

  • 송관철;정영상;김병찬;안윤수;엄기태
    • 한국토양비료학회지
    • /
    • 제25권3호
    • /
    • pp.220-230
    • /
    • 1992
  • 우리나라에서 토양(土壤) 온도(溫度)를 정규적으로 관측(觀測)하고 있는 기상청(氣象廳) 산하(傘下) 기상대(氣象臺) 및 관측소(觀測所) 관측(觀測) 노장(露長)의 토양시료(土壤試料)를 채취(採取)하여 토양(土壤)의 열전도(熱傳度) 특성(特性)과 관련이 깊은 토양(土壤)의 용적밀도(容積密度), 토성(土性), 유기물(有機物) 함량(含量) 등 물리적(物理的) 특질(特質)을 분석(分析)하였으며, 토양(土壤)의 열확산(熱擴散) 계수(係數)를 산출(算出)하였다. 기상청(氣象廳) 산하(傘下) 기상대(氣象臺) 및 관측소(觀測所) 토양(土壤)의 물리적(物理的) 특성(特性)을 조사한 결과(結果) 0-10cm의 표토(表土)는 52%가 사양토(砂壤土)였으며, 양토(壤土)와 미사질양토(微砂質壤土)가 38%, 그리고 식양토(埴壤土) 및 미사질식토(微砂質埴土)가 10%이었다. 이들 토양(土壤)의 열특성(熱特性)과 관계가 깊은 용적밀도(容積密度)는 사토(砂土)가 $1.41g/cm^3$, 양토(壤土)와 미사질양토(微砂質壤土)가 $1.33g/cm^3$, 그리고 식양토9埴壤土) 및 미사질식토(微砂質埴土)가 $1.21g/cm^3$로 토성(土性)이 미세할수록 낮은 값을 보였다. 열확산(熱擴散) 계수(係數)는 평균(平均) $3.53{\times}10^{-3}cm^3/sec$이었으며, $1.159-8.401{\times}10^{-3}cm^3/sec$의 범위에 있었다. 특히 유기물(有機物) 함량(含量)이 높고 용적밀도(容積密度)가 낮은 제주도(濟州道) 토양(土壤)의 열확산(熱擴散) 계수(係數)는 표토(表土)에서 $2{\times}10^{-3}cm^3/sec$으로 다른 지역의 토양(土壤)보다 현저히 낮았다. 토심(土深) 30cm 이하(以下) 토양(土壤)의 열확산(熱擴散) 계수(係數)는 평균(平均) $6.81{\times}10^{-3}cm^3/sec$$1.54-16.12{\times}10^{-3}cm^3/sec$의 범위를 보여 표토(表土)보다 높았다. 열확산(熱擴散) 계수(係數)로부터 계산(計算)된 표토(表土)의 일주간(日週期) 불역심(不易深)(damping depth)은 5.92-13.65cm였으며, 깊이 30cm이하의 연주기(年週期) 불역심(不易深)은 124-342cm이었다. 한편, 실험실내(實驗室內)에서 열선막대법에 의하여 측정(測定)된 열확산9熱擴散) 계수(係數)와 용적밀도(容積密度) 및 토양수분함량(土壤水分含量)과의 관계로부터 열확산(熱擴散) 계수(係數)를 추정(推定)할 수 있는 중회귀(重回歸) 모델을 이용하면 토양온도(土壤溫度)가 부족한 지점(地點)의 열확산(熱擴散) 계수(係數)를 추정(推定)할 수 있게 되었다.

  • PDF

FUNDAMENTAL STUDY ON THE RECOVERY AND REMOVAL OF WHITE PHOSPHORUS FROM PHOSPHORUS SLUDGE

  • Jung, Joon-Oh
    • Environmental Engineering Research
    • /
    • 제10권1호
    • /
    • pp.38-44
    • /
    • 2005
  • Electro-thermal production of white phosphorus(WP, P4) generates substantial amount of highly toxic phossy water and sludges. Because of their high phosphorus contents and lack of reliable processing technology, large tonnages of these hazardous wastes have accumulated from current and past operations in the United States. In this study, two different methods for treatment of phosphorus sludge were investigated. These were bulk removal of WP by physical separation(froth flotation) and transformation of WP to oxyphosphorus compounds by air oxidation in the sludge medium. Kerosene, among other collectors, resulted in selective flotation of WP from the associated mineral gangue. Solvent action of kerosene occurring on the WP surface(by rendering WP particles hydrophobic) might produce the high selectivity of WP. The WP recovery in the froth was 79.3% from a sludge assaying 34.2% of WP. In the oxidation study, air gas was dispersed in the sludge medium by the rapid rotation of the impeller blades. The high level of sludge agitation intensity caused a fast completion of the oxidation reactions and it resulted in the high percentage conversion of WP to PO4-3 with PO3-3 making up almost all portion of oxyphosphorus compounds. The WP analysis on the treated sludge showed that supernatant solution and solid residue contained an average of 4.2 μg/L and 143 ppm respectively from the sludge containing about 26 g of WP. Further investigation will be required on operational factors to better understand the processes and achieve an optimum condition.

수도용 강관의 온도변화에 따른 물리적 특성에 대한 연구 (Study on the Physical Characteristics of Water Supply Steel Pipe according to Temperature Change)

  • 김우영;장암
    • 대한환경공학회지
    • /
    • 제39권12호
    • /
    • pp.733-740
    • /
    • 2017
  • 환경부에서 수립한 "상수도 시설기준(2004)"은 관로 신축이음관 설치기준에 있어서는 용접이음 강관에는 설치하지 않는 것으로 규정하고 있으며, 이에 대한 근거가 명확하지 않고 관로 안정성이 충분히 확보되었는지 확인하기가 어렵다. 금번 연구에서는 강관의 거동 분석을 통한 관로 안정성을 연구하여 신축이음관의 필요여부를 검증하는 것을 목적으로 하였다. 검토결과는 아래와 같다. 첫째, 아스팔트 도복장강관(D2,400 mm)은 온도변화에 따라 4-cycle로 관로 신 수축이 반복되며, 연장 1.24 km에 있어 최대 13.03 mm의 변위를 나타내었다. 둘째, 수도용 강관의 신 수축으로 발생되는 온도응력은 매설깊이(최대 4 m)에 따라 $13.7{\sim}36.1kgf/cm^2$로 발생되며, 강관(STWW 400)의 안정성에 큰 영향을 키치는 주요 비교인자인 허용 인장강도와 피로한도는 $4,100kgf/cm^2$$1,840kgf/cm^2$로 산출되었다. 마지막으로, 수도용 강관의 온도응력은 허용 인장강도와 피로한도와 비교시 매우 작음에 따라, 온도변화에 의한 관로의 신 수축이 발생하여도 관로 안정성에는 영향을 끼치지 못함을 알 수 있었다. 결론적으로 금번 연구를 통하여 수도용 강관의 관로부에는 신축이음관을 설치할 필요가 없는 것으로 증명되었다.

지중 열교환기용 벤토나이트 그라우트의 시공성에 대한 화학적, 물리적 영향 요소에 관한 연구 (Chemical and Physical Influence Factors on Performance of Bentonite Grouts for Backfilling Ground Heat Exchanger)

  • 이철호;길후정;이강자;최항석;최효범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1475-1486
    • /
    • 2008
  • Bentonite-based grouting has been popularly used to seal a borehole installed for a closed-loop vertical ground heat exchanger in a geothermal heat pump system (GHP) because its high swelling potential. However, if the bentonite-based grouting is conducted in coastal areas, the salinity of groundwater changes in the mineral fabric of bentontie. In order words, an increase of cation concentration in groundwater leads to a reduction in the diffuse double-layer thickness in the bentonite mineral structure, and thus the volume of bentointe-based grouts will decrease proportional to the salinity of groundwater. In this paper, the effect of salinity (i.e., NaCl 0.5M, 0.25M, and 0.1M) on the change of swelling potential for bentonite-based grouts has been quantitatively evaluated for seven bentonite grouts from different product sources. In addition, in case of using addictives such as a silica sand to increase the thermal conductivity of bentonite-based grouts, the possibility of particle segregation has been studied considering the viscosity of grouts and salinity of groundwater.

  • PDF

시간 변화에 따른 여름철 산림환경의 생리ᐧ심리적 안정 효과 (Temporal Changes in the Physiological and Psychological Relaxation Effects of a Forest Environment during the Summer)

  • 송인준;김주현;김초윤;정다워;이윤정;박범진;송초롱
    • 한국산림과학회지
    • /
    • 제113권1호
    • /
    • pp.107-117
    • /
    • 2024
  • 본 연구는 시간에 따른 산림환경의 물리환경요소 변화와 이에 따른 온열환경 쾌적성, 인체의 생리·심리적 반응의 차이를 종합적으로 규명하기 위하여 수행되었다. 9시부터 18시까지 산림환경의 물리환경요소(공기온도, 평균복사온도, 풍속, 상대습도)와 예상평균한서감지수(PMV), 예상불만족률(PPD)를 연속 측정하고, 1시간 간격으로 남자 대학생 30명(평균 연령: 21.7±1.9세)이 눈을 감고 5분 동안 안정을 취할 때의 생리·심리적 반응(심박변이도, 심박수, 구강체온, 혈압, 맥박수, 주관적 온열감과 쾌적감 및 인상)을 조사하였다. 더불어 물리환경요소와 생리적 반응 사이의 상관관계를 조사하였다. 그 결과, ① 공기온도, 평균복사온도, 풍속, 상대습도 모두 시간에 따라 유의하게 변화하였다. ② PMV와 PPD도 시간에 따라 유의하게 변화하였다. 주관적 온열감은 PMV와 일치하였으나, 주관적 쾌적감은 PPD와 일치하지 않았다. ③ 생리적 반응 중 ln(HF), ln(LF/HF), 심박수, 이완기혈압이 시간에 따라 유의하게 변화하였다. 공기온도가 가장 높았던 14~16시에 ln(HF)는 가장 낮았고, ln(LF/HF)는 가장 높았다. ④ 공기온도, 평균복사온도, 풍속은 ln(HF)와 음의 상관관계, ln(LF/HF)와 양의 상관관계를 나타내었다. 이를 통해 산림환경을 이용하는 시간대에 따라 이용객의 쾌적감과 생리·심리적 안정 효과가 달라질 수 있으며, 시간에 따른 산림환경의 물리환경요소 변화가 이러한 차이에 영향을 미친다는 사실이 밝혀졌다.

지열 발전정 시멘팅을 위한 G-class 시멘트 특성 평가에 관한 연구 (Evaluation of Characteristics of G-class Cement for Geothermal Well Cementing)

  • 원종묵;전종욱;박상우;최항석
    • 한국지반공학회논문집
    • /
    • 제29권5호
    • /
    • pp.29-38
    • /
    • 2013
  • G-class 시멘트는 지열발전소 가동 시에 지열정에서 고온의 지열수나 증기를 심부에서 지표면까지 이동시키는 케이싱을 보호하는 시멘팅 재료로서 이용된다. 지열정을 통한 원활한 지열발전을 위해서는 시멘팅 재료의 물리적 특성들이 만족되어야 한다. 본 연구에서는 G-class 시멘트를 지열정 시멘팅 재료로서의 중요한 물리적 특성인 유동성, 일축압축강도, 열전도도, free fluid 함유율(Free fluid content) 등을 평가하기 위해, 다양한 물/시멘트 비 조건에서 실내실험을 수행하였다. G-class 시멘트에 대한 물리적 특성 평가를 통해 다음과 같은 결론을 도출하였다. (1) G-class 시멘트의 유동성은 소량의 응고지연제(retarder)를 첨가하여 증가 시킬 수 있다. (2) 유동성 확보를 위해 물/시멘트 비를 높일 경우, 일축압축강도가 감소하여 지열정의 구조적 문제를 야기할 수 있다. (3) G-class 시멘트의 열전도도는 지열정 가동 시에 지열정에서 외부 지반으로의 열손실이 거의 없을 정도로 낮게 평가되었다. (4) G-class 시멘트를 시멘팅 재료로 이용할 경우, 블리딩(bleeding) 가능성은 매우 낮은 것으로 판단된다. (5) 페놀프탈레인 지시약은 지열정 시공시 지표면에서 시추용 이수와 G-class 시멘트를 구분하기 위해 적합할 것으로 판단된다.