• 제목/요약/키워드: Physical Parameters

검색결과 2,838건 처리시간 0.026초

Determination of Physical Camera Parameters from DLT Parameters

  • Jeong Soo;Lee Changno;Oh Jaehong
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.233-236
    • /
    • 2004
  • In this study, we analyzed the accuracy of the conversion from DLT parameters to physical camera parameters and optimized the use of DLT model for non-metric cameras in photogrammetric tasks. Using the simulated data, we computed two sets of physical camera parameters from DLT parameters and Bundle adjustment for various cases. Comparing two results based on the RMSE values of check points, we optimized the arrangement of GCPs for DLT.

  • PDF

만성요통환자의 보행특성에 관한 연구 (A Study on the Characteristics of Gait in Patients with Chronic Low Back Pain)

  • 김경;고주연;이성용
    • The Journal of Korean Physical Therapy
    • /
    • 제21권2호
    • /
    • pp.79-85
    • /
    • 2009
  • Purpose: This study examined the characteristics of gait in patients with chronic low back pain. Methods: The subjects were out-patients suffering from chronic low back pain at the department of physical therapy, B hospital in Seoul. Gait analysis was performed by dividing the subjects into two groups. The study and control group comprised 15 chronic low back pain patients and 14 healthy people, respectively. Gait analysis was performed using a VICON 512 Motion Analysis System to obtain the spatio-temporal and kinematic parameters. Results: First, there was a significant difference in the spatio-temporal parameters between the two groups (p<0.05). Second, the study group showed significant differences in the kinematic parameters during the stance phase (p<0.05). Third, there were significant differences in kinematic parameters in the study group during the swing phase (p<0.05). Conclusion: The gait pattern of patients with chronic low back pain is characterized by more rigid patterns. Compared to the control group, there was a decrease in the spatio-temporal parameters and kinematic parameters in patients with chronic low back pain. These findings are expected to play a role as basic data and to form a rehabilitation program for low back pain patients.

  • PDF

Effects of observation parameters on time transfer using GPS

  • Lee, Seung-Woo;Lee, Chang-Bok;Yang, Sung-Hoon;Lee, Young-Kyu;Han, Ji-Ae
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 International Symposium on GPS/GNSS Vol.2
    • /
    • pp.113-116
    • /
    • 2006
  • In order to fully utilize the inherent precision that GPS observables could offer, accurate estimation of dynamic and measurement parameters is vital. Among these parameters some are indispensable in virtually every form of GPS processing, while some are limitedly relevant to a particular application. In the context of time transfer by GPS, the transmission-related errors such as ionospheric and tropospheric delays, and the integer ambiguity of the carrier phase observables belong to the former, the atomic clock parameters and data batch-related parameters to the latter. Obviously the atomic clock parameters are of prime importance in GPS time transfer. In this study some of important parameters in conducting time transfer experiments by use of GPS were characterized and their effects on time transfer performance were investigated in detail

  • PDF

65세 이상 건강한 노인의 보행분석 (Gait analysis of the healthy elderly over 65years of age)

  • 홍완성;김기원
    • The Journal of Korean Physical Therapy
    • /
    • 제14권4호
    • /
    • pp.45-54
    • /
    • 2002
  • The purpose of this study was to describe the gait pattern and parameters of the healthy elderly over 65years of age by the GATERite system. The subjects were sorted into two groups, depending on their sex: male and female. And female subjects were sorted into three groups, depending on their age. From time parameters and space parameters of gait cycle, between groups, the following results were made. The time parameters such as cadence, velocity, step time, single support and double support were the less the male than the female. And the higher age, the lower value except 80 age group, while no statistically significant. The space parameters(step length and stride length) were the longer the male than the female, and the higher age, the lower value while no statistically signigicant. The functional ambulation profile was high correlation with time and space parameters statistically significant.

  • PDF

목보조기의 적용 유무와 보행의 시공간적 변수와의 관계 (The relationship of between apply presence cervical orthosis and temporal parameters of gait)

  • 최한성;이재룡;신화경
    • 대한물리치료과학회지
    • /
    • 제18권3호
    • /
    • pp.33-39
    • /
    • 2011
  • Background : The purpose of this study was to apply cervical orthosis for temporal parameters of gait was to evaluate the effect. Methods : Seven normal adults participated in this study. Before and after applying a cervical orthosis compared to gait. Outcome measure were: general characteristics, temporal parameters of gait. General chacteristics included age, gender, height, weight. Temporal parameters included the Velocity cycle, Stride length, Step length, Cadence cycle, Initial double support time. Temporal parameters of gait, using the motion analysis system for cervical orthosis were evaluated before and after applying. The data was analyzed using SPSS 12.0 software and the Wilcoxon's signed-ranks test. Results : Velocity cycle and Step length were no significant differences(p>0.05). But Stride length, Cadence cycle, Initial double support time were significant(p<0.05). After apply Cervical orthosis in gait, Stride length and Initial double support time was decreased and Cadence cycle was increased. Conclusion : Changes in temporal of temporal parameters of gait was apply a cervical orthosis with the limitations of vision due to take effect. Therefore, Cervical orthosis does not interfere with the normal gait pattern by limiting the Range of Motion so that we consider to apply.

  • PDF

Evaluation of reactor pulse experiments

  • I. Svajger;D. Calic;A. Pungercic;A. Trkov;L. Snoj
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1165-1203
    • /
    • 2024
  • In the paper we validate theoretical models of the pulse against experimental data from the Jozef Stefan Institute TRIGA Mark II research reactor. Data from all pulse experiments since 1991 have been collected, analysed and are publicly available. This paper summarizes the validation study, which is focused on the comparison between experimental values, theoretical predictions (Fuchs-Hansen and Nordheim-Fuchs models) and calculation using computational program Improved Pulse Model. The results show that the theoretical models predicts higher maximum power but lower total released energy, full width at half maximum and the time when the maximum power is reached is shorter, compared to Improved Pulse Model. We evaluate the uncertainties in pulse physical parameters (maximum power, total released energy and full width at half maximum) due to uncertainties in reactor physical parameters (inserted reactivity, delayed neutron fraction, prompt neutron lifetime and effective temperature reactivity coefficient of fuel). It is found that taking into account overestimated correlation of reactor physical parameters does not significantly affect the estimated uncertainties of pulse physical parameters. The relative uncertainties of pulse physical parameters decrease with increasing inserted reactivity. If all reactor physical parameters feature an uncorrelated uncertainty of 10 % the estimated total uncertainty in peak pulse power at 3 $ inserted reactivity is 59 %, where significant contributions come from uncertainties in prompt neutron lifetime and effective temperature reactivity coefficient of fuel. In addition we analyse contribution of two physical mechanisms (Doppler broadening of resonances and neutron spectrum shift) that contribute to the temperature reactivity coefficient of fuel. The Doppler effect contributes around 30 %-15 % while the rest is due to the thermal spectrum hardening for a temperature range between 300 K and 800 K.

신체활동과 골초음파지표와의 연관성 (Association Between Physical Activity and Quantitative Ultrasound in a Rural Population)

  • 김승준;신민호;권순석
    • 한국전문물리치료학회지
    • /
    • 제12권2호
    • /
    • pp.20-27
    • /
    • 2005
  • Osteoporosis is characterized by low bone mass and the microarchitectural deterioration of bone tissue with a consequent increase in bone fragility and susceptibility to fracture. It has been suggested that speed of sound (SOS) and broadband ultrasound attenuation (BUA) of quantitative ultrasound sonography (QUS) may provide information about not only bone density but also the microarchitecture and elastic properties of bone. Physical inactivity reduced mechanical usage and it made process to the bone changes. This study aimed to association between the physical activity and the QUS parameters in 1305 (593 men, 712 women) aged 20 years over in a rural population. Two QUS parameters, BUA (p=.23) and SOS(p=.73) were measured at the right calcaneus of postmenopausal women, no significant associations were observed between sports index and SOS and BUA. These results suggest that work, non-sports leisure physical activity (p<.01) have a significant influence on QUS parameters in a rural population. Physical activity are meaningful predictor of QUS parameters of the calcaneus in a rural population.

  • PDF

Changes in Gait Patterns after Physical Therapy in Patients with Non-specific Chronic Low Back Pain: a Pilot Study

  • Song, Seonghyeok;Cho, Namjeong;Kim, Hyun-Joong
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권1호
    • /
    • pp.105-112
    • /
    • 2022
  • Objective: Nonspecific low back pain (NS-LBP) causes pain and disability, affecting the neuromuscular system and altering gait patterns. The purpose of this study is to investigate the effect of improvement of low back pain symptoms through physical therapy on foot pressure and spatiotemporal gait parameters. Design: A pilot study. Methods: Participants received manual therapy and supervised therapeutic exercise, which consisted of 12 sessions for 6 weeks. Participants were assessed for pain intensity (a numeric pain rating scale), disability index (oswestry disability index), and spatiotemporal gait parameters before and after intervention. Wilcoxon signed rank test was used to analyze the before-and-after differences in a single group. Results: All seven NS-LBP patients completed the study without dropout. After six weeks of physical therapy, the numeric pain rating scale and oswestry disability index showed significant improvement (Z= -2.388, P=0.017). There was no significant improvement in both static and dynamic conditions in foot pressure (P>0.05). However, in the spatiotemporal gait parameters, there were significant differences in all variables except the right stance phase and left mid stance (P<0.05). Conclusions: In our pilot study, 12 sessions of physical therapy in NS-LBP patients improved gait quilty in spatiotemporal gait parameters. Similarly, it has resulted in clinically positive improvements in pain and disability.

Fast Spectral Inversion of the Strong Absorption Lines in the Solar Chromosphere Based on a Deep Learning Model

  • Lee, Kyoung-Sun;Chae, Jongchul;Park, Eunsu;Moon, Yong-Jae;Kwak, Hannah;Cho, Kyuhyun
    • 천문학회보
    • /
    • 제46권2호
    • /
    • pp.46.3-47
    • /
    • 2021
  • Recently a multilayer spectral inversion (MLSI) model has been proposed to infer the physical parameters of plasmas in the solar chromosphere. The inversion solves a three-layer radiative transfer model using the strong absorption line profiles, H alpha and Ca II 8542 Å, taken by the Fast Imaging Solar Spectrograph (FISS). The model successfully provides the physical plasma parameters, such as source functions, Doppler velocities, and Doppler widths in the layers of the photosphere to the chromosphere. However, it is quite expensive to apply the MLSI to a huge number of line profiles. For example, the calculating time is an hour to several hours depending on the size of the scan raster. We apply deep neural network (DNN) to the inversion code to reduce the cost of calculating the physical parameters. We train the models using pairs of absorption line profiles from FISS and their 13 physical parameters (source functions, Doppler velocities, Doppler widths in the chromosphere, and the pre-determined parameters for the photosphere) calculated from the spectral inversion code for 49 scan rasters (~2,000,000 dataset) including quiet and active regions. We use fully connected dense layers for training the model. In addition, we utilize a skip connection to avoid a problem of vanishing gradients. We evaluate the model by comparing the pairs of absorption line profiles and their inverted physical parameters from other quiet and active regions. Our result shows that the deep learning model successfully reproduces physical parameter maps of a scan raster observation per second within 15% of mean absolute percentage error and the mean squared error of 0.3 to 0.003 depending on the parameters. Taking this advantage of high performance of the deep learning model, we plan to provide the physical parameter maps from the FISS observations to understand the chromospheric plasma conditions in various solar features.

  • PDF

IMPLEMENTATION OF DATA ASSIMILATION METHODOLOGY FOR PHYSICAL MODEL UNCERTAINTY EVALUATION USING POST-CHF EXPERIMENTAL DATA

  • Heo, Jaeseok;Lee, Seung-Wook;Kim, Kyung Doo
    • Nuclear Engineering and Technology
    • /
    • 제46권5호
    • /
    • pp.619-632
    • /
    • 2014
  • The Best Estimate Plus Uncertainty (BEPU) method has been widely used to evaluate the uncertainty of a best-estimate thermal hydraulic system code against a figure of merit. This uncertainty is typically evaluated based on the physical model's uncertainties determined by expert judgment. This paper introduces the application of data assimilation methodology to determine the uncertainty bands of the physical models, e.g., the mean value and standard deviation of the parameters, based upon the statistical approach rather than expert judgment. Data assimilation suggests a mathematical methodology for the best estimate bias and the uncertainties of the physical models which optimize the system response following the calibration of model parameters and responses. The mathematical approaches include deterministic and probabilistic methods of data assimilation to solve both linear and nonlinear problems with the a posteriori distribution of parameters derived based on Bayes' theorem. The inverse problem was solved analytically to obtain the mean value and standard deviation of the parameters assuming Gaussian distributions for the parameters and responses, and a sampling method was utilized to illustrate the non-Gaussian a posteriori distributions of parameters. SPACE is used to demonstrate the data assimilation method by determining the bias and the uncertainty bands of the physical models employing Bennett's heated tube test data and Becker's post critical heat flux experimental data. Based on the results of the data assimilation process, the major sources of the modeling uncertainties were identified for further model development.