• Title/Summary/Keyword: Physical Parameter

Search Result 873, Processing Time 0.03 seconds

Thermodynamic Study of Poly(dimethylsiloxane)-Solvents Systems Using Inverse Gas Chromatography (Inverse Gas Chromatography를 이용한 Poly(dimethylsiloxane)-Solvent계의 열역학적 연구)

  • Cho, Joung-Mo;Kang, Choon-Hyoung
    • Applied Chemistry for Engineering
    • /
    • v.10 no.5
    • /
    • pp.718-725
    • /
    • 1999
  • In order to investigate the interaction characteristics of poly(dimethylsiloxane) (PDMS) with various solvents such as water, ethanol, and iso-propanol, Inverse Gas Chromatography(IGC) at finite concentration, which is a very fast, accurate, and thus promising technique in thermodynamic study of polymer systems, is employed. By measuring the specific retention volumes of the probes, the interaction parameters are calculated by means of the Flory-Huggins equation. From the results, the interaction parameters of the probes are, as expected due to the hydrophobicity of the polymer, found to be of large positive values (2$2.0{\times}10^{-3}mol/g$. For the linear PDMS, interpretation of the space distribution of molecules is performed by the Kirkwood-Buff-Zimm(KBZ) integrals, which give intuitive information about physical properties. From the KBZ integrals, water does not show the tendency of preferential solvation with the PDMS but formed self-cluster. The larger solvent molecules show a stronger tendency to distribute more randomly in the mixture.

  • PDF

Augmented Reality Based Tangible Interface For Digital Lighting of CAID System (CAID 시스템의 디지털 라이팅을 위한 증강 현실 기반의 실체적 인터페이스에 관한 연구)

  • Hwang, Jung-Ah;Nam, Tek-Jin
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.119-128
    • /
    • 2007
  • With the development of digital technologies, CAID became an essential part in the industrial design process. Creating photo-realistic images from a virtual scene with 3D models is one of the specialized task for CAID users. This task requires a complex interface of setting the positions and the parameters of camera and lights for optimal rendering results. However, the user interface of existing CAID tools are not simple for designers because the task is mostly accomplished in a parameter setting dialogue window. This research address this interface issues, in particular the issues related to lighting, by developing and evaluating TLS(Tangible Lighting Studio) that uses Augmented Reality and Tangible User Interface. The interface of positioning objects and setting parameters become tangible and distributed in the workspace to support more intuitive rendering task. TLS consists of markers, and physical controller, and a see-through HMD(Head Mounted Display). The user can directly control the lighting parameters in the AR workspace. In the evaluation experiment, TLS provide higher effectiveness, efficiency and user satisfaction compared to existing GUI(Graphic User Interface) method. It is expected that the application of TLS can be expanded to photography education and architecture simulation.

  • PDF

Estimates of Regional Flood Frequency in Korea (우리나라의 빈도홍수량의 추정)

  • Kim, Nam-Won;Won, Yoo-Seung
    • Journal of Korea Water Resources Association
    • /
    • v.37 no.12
    • /
    • pp.1019-1032
    • /
    • 2004
  • Flood frequency estimate is an essential index for determining the scale of small and middle hydraulic structure. However, this flood quantity could not be estimated directly for practical design purpose due to the lack of available flood data, and indirect method like design rainfall-runoff method have been used for the estimation of design flood. To give the good explain for design flood estimates, regional flood frequency analysis was performed by flood index method in this study. First, annual maximum series were constructed by using the collected data which covers from Japanese imperialism period to 1999. Wakeby distribution recommended by WMO(1989) was used for regional flood frequency analysis and L-moment method by Hosking (1990) was used for parameter estimation. For the homogeneity of region, the discordance and heterogeneity test by Hosking and Wallis(1993) was carried for 4 major watersheds in Korea. Physical independent variable correlated with index flood was watershed area. The relationship between specific discharge and watershed area showed a type of power function, i.e. the specific discharge decreases as watershed area increases. So flood quantity according to watershed area and return period was presented for each watershed(Han rivet, Nakdong river, Geum river and Youngsan/Seomjin river) by using this relation type. This result was also compared with the result of point frequency analysis and its regionalization. It was shown that the dam construction couldn't largely affect the variation of peak flood. The property of this study was also examined by comparison with previous studies.

Heat Transfer Characteristics of CO2 at Supercritical Pressure in a Vertical Circular Tube (수직원형관에서 초임계압 CO2의 열전달 특성)

  • Yoo, Tae-Ho;Bae, Yoon-Yong;Kim, Hwan-Yeol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.1
    • /
    • pp.23-31
    • /
    • 2011
  • At supercritical pressure, the physical properties of fluid change substantially and the heat transfer at a temperature similar to the critical or pseudo-critical temperature improves considerably; however, the heat transfer may deteriorate due to a sudden increase in the wall temperature at a certain condition of a mass and heat flux. In this study, the heat transfer rates in $CO_2$ flowing vertically upward and downward in a circular tube with a diameter of 4.57 mm under various conditions were calculated by measuring the temperature of the outer wall of the tube. The published heat transfer correlations were analyzed by comparing their prediction values with 7,250 experimental data. By introducing a buoyancy parameter, a heat transfer correlation, which could be applied only to a normal heat transfer regime, was extended such that it can be applied to regime of heat transfer deterioration. The published criteria for heat transfer deterioration were evaluated against the conditions obtained from the experiment in this study.

Histopathological observation of liver in cultured black rock fish Sebastes schlegeli in low temperature season (저수온기 양식 조피볼락, Sebastes schlegeli 간에 대한 조직병리학적 연구)

  • Choi, Hye-Sung;Huh, Min-Do;Lee, Mu-Kun;Choi, Hee-Jung;Park, Myung-Ae
    • Journal of fish pathology
    • /
    • v.24 no.3
    • /
    • pp.225-236
    • /
    • 2011
  • This study was aimed to determine the fish physical status according to the gross and histopathological findings of liver in cultured black rock fish, Sebastes schlegeli. All 47 fish submitted had no marked abnormalities in the external findings. 42.55% of fish showed normal liver, 25.53% yellow liver, 25.53% atrophic brown liver, 4.26% yellowish-green liver and 2.13% fatty liver in gross examination. Grossly normal liver showed no remarkable change in lobular structure but many vacuoles were found in hepatic cell. Hepatic cells took normal roundish, polygonal shapes containing spherical nuclei. In group of yellow-brown liver, many brown pigments were seen in hepatic cells, MMCs and brown-colored hyaline droplets within cytoplasm of hepatocytes. Yellowish green pigments were seen in hepatic cells and MMCs of yellow green liver and green colored hyaline droplets within hepatocytes. The dilated central veins are highlighted with atrophy of hepatic cells. Outline of atrophic hepatocyte became ambiguous and nucleus frequently become small and pyknotic. Fatty liver showed prominent vacuolar structures in cells as clear spaces or foamy cytoplasm with degenerative nuclei. From these results, it was strongly suggested that hepatic gross and histological findings could be used as important and critical health parameters of fish prior to progression to substantial manifestation as clinical disease.

Development and Application of Diffusion Wave-based Distributed Runoff Model (확산파에 기초한 분포형 유출모형의 개발 및 적용)

  • Lee, Min-Ho;Yoo, Dong-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.7
    • /
    • pp.553-563
    • /
    • 2011
  • According to the improvement of computer's performance, the development of Geographic Information System (GIS), and the activation of offering information, a distributed model for analyzing runoff has been studied a lot in recently years. The distribution model is a theoretical and physical model computing runoff as making target basin subdivided parted. In the distributed model developed by this study, the volume of runoff at the surface flow is calculated on the basis of the parameter determined by landcover data and a two-dimensional diffusion wave equation. Most of existing runoff models compute velocity and discharge of flow by applying Manning-Strickler's mean velocity equation and Manning's roughness coefficient. Manning's roughness coefficient is not matched with dimension and ambiguous at computation; Nevertheless, it is widely used in because of its convenience for use. In order to improve those problems, this study developed the runoff model by applying not only Manning-Strickler's equation but also Chezy's mean velocity equation. Furthermore, this study introduced a power law of exponential friction factor expressed by the function of roughness height. The distributed model developed in this study is applied to 6 events of fan-shape basin, oblong shape test basin and Anseongcheon basin as real field conditions. As a result the model is found to be excellent in comparison with the exiting runoff models using for practical engineering application.

The Study on a Various Parameter for the CT Test and the Patients-Anxiety of Factor Related (CT검사 시 다양한 매개변수와 환자의 불안 요인에 관한 연구)

  • Baek, Cheol-Oh;Han, Man-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.149-156
    • /
    • 2011
  • This study is to identify perceptions and response degrees of anxiety for each factor, targeting patients for CT test and analyze the relations between factors. It is to provide scientific fundamental data to reduce anxiety by improving awareness of patients about CT test by analyzing relations between variables. The subjects of this study were surveyed in self-writing type, targeting 263 patients for CT test in the department of radiology at three University hospitals from July to September, 2010. This survey was executed once by a structured self-administered survey type. The targeting patients for CT test of anxiety will investigate for affect. Anxiety by each CT test variables depending on CT test-related features showed independent variable is Expense Responsibility, Economic burden, Sufficient explain, Explain agent, Endoscope, Biopsy, Pre treatment, Previous experience, CT side effect experience, Side effect of contrast medium and dependent variable is physical, Hospital staff, Hospital environment, Socioeconomic These used statistics program SPSS (ver. 13.0). Summarizing the above results of this study, awareness of anxiety and response to it in each variable under CT test appeared significant differences in economic burdens, state anxiety, pre-treatment anxiety, exposure anxiety to radiation, and anxiety of side effect. Therefore, pre-treatment before test and pre-training programs on chemical poison of contrast medium and side effect seem to be able to release patients' anxiety level for CT test. Ways to meditate these anxiety variables and reduce degree of anxiety are needed to be researched more and updated. In addition, impact of patients' economic burdens on CT test anxiety is required to be recognized and solved in society level.

Spectroscopic Observation of AG Peg and Efficiency Changes of Bowen Fluorescence Mechanism (AG Peg의 분광 관측과 Bowen 형광 기작의 효율 변화)

  • Hyung, Siek;Lee, Seong-Jae;Lee, Kang Hwan
    • Journal of the Korean earth science society
    • /
    • v.38 no.6
    • /
    • pp.405-420
    • /
    • 2017
  • We investigated the H I, He II and O III emission lines of the symbiotic star AG Peg, using the spectroscopic data secured at different phases in three periods at the Lick Observatory. We measured FWHM and the intensity of six O III Bowen lines and studied the efficiency of fluorescence mechanism. The mean FWHM of O III normal and Bowen lines observed during three time periods did not make much difference, while Bowen line intensities are about 4.0 times higher than the normal lines. Comparing the predicted and the observed ratios, we found that the observed intensities are higher than predicted intensities, except for O III ${\lambda}$ 3759.87. The O III ${\lambda}$ 3791.26 and 3754.67 intensity ratios observed only in 2001 are in good agreement with the predictions by Saraph and Seaton (1980). We obtained the Bowen efficiency parameter (R)=0.47 for 2002, but we could not find R for the other two periods of time. Because of this, based on the 2002 efficiency result, we calculated the intensity ratio of O III normal and Bowen lines relative to He II ${\lambda}$ 4685.68 and derive the efficiency variation with time period. The result showed that the efficiency is the highest in 1998 and the lowest in 2001. We conclude that the efficiencies with phase are caused by the electron temperature changes in the ionized gas. The efficiencies of AG Peg are likely to increase along with electron temperature. Our analysis results may be useful in understanding the physical conditions of the ionized shell in symbiotic star and the intensity ratio and efficiency variation.

Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals (다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상)

  • Jung, Woon-Mo;Sim, Myeong-Heon;Jung, Sang-O;Kim, Min-Yong;Yoon, Chan-Sol;Jung, In-Chol;Yoon, Hyung-Ro
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

Feasibility Study of Parallel- Plate Detector Using Dielectric film for 6 MV X-ray (6MV X-선 검출특성 조사를 위하여 유전체 필름을 이용하여 제작한 평행판 검출기의 유용성)

  • 조문준;김용은;이병용;김정기;임상욱;김현수;김기환
    • Progress in Medical Physics
    • /
    • v.15 no.2
    • /
    • pp.105-111
    • /
    • 2004
  • The parallel plate detector with dielectric film for dosimetry was designed to measure detection characteristic of 6 MV X-ray with medical linear accelerator. PTFE film was inserted into FEP films that are made by two one-side metal coated materials for ion source. The thicknesses of PTFE dielectric film was 100 ${\mu}{\textrm}{m}$ and the thickness of FEP dielectric film was 100 ${\mu}{\textrm}{m}$, respectively. This detector was fixed by two acrylic plate for physical hardness ad geometrical consistency. The geometrical condition for measurement with parallel-plate for detector was below; SSD=100 cm and the 5 cm depth between detector and phantom surface The major parameter of detector characteristics such as zero drift current, leakage current, charge response by applied voltage, reproducibility, linearity, TMR measurement, dose rate effect were measured. The zero drift currents are 8.3 pA and leakage currents are 10 pA. The charge response of applied voltage is showing linearity in 414 voltage. The measurement deviation of reproducibility in this detector is within 1% for dose and the linearity of applied dose shows in this detector. The TMR curves in phantom between this parallel plate detector and reference detector are matched within 3% deviation from maximum dose depth to 7.5 cm depth. It is considered that this dosimetric system is satisfactory for the purpose of the constancy check of the 6 MV x-ray from medical linear accelerator.

  • PDF