• Title/Summary/Keyword: Physical Machine

Search Result 838, Processing Time 0.031 seconds

A STUDY ON THE PHYSICAL PROPERTIES AND COLOR STABILITY OF MAXILLOFACIAL PROSTHETIC SILICONE MATERIAL (악안면 보철용 실리콘의 물리적 특성 및 색조안정성에 관한 연구)

  • Park, Chan-Jin;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.330-343
    • /
    • 1997
  • Extraoral maxillofacial prostheses are essential for restoring facial structures that are lost as a result of congenital missing, injuries from accidents, surgical treatments of head and neck cancer. Recently, silicone is the most useful material for this purpose and is more advantageous than other maxillofacial prosthetic materials. However, there are some problems for long-term usage of silicone prostheses due to tear and color change. These are major contributing environmental factors to those problems that are such as ultraviolet light, cleansing agents, changes in humidity and successive adhesion and removal. The aim of this study is to evaluate the physical properties and color changes of maxillofacial prosthetic silicone material by those environmental factors using A-2186 silicone material (Factor II, USA) and two pigments, cadmium yellow medium and cosmetic red. Aluminium molds were fabricated according to the ASTM No. D412 & D624 specifications and resulted specimens from molds were fabicated and treated as follows. Control group and experimental I group were fabricated with 0.1% wt. pigment mixing in silicone elastomer and II-1 group, II-2 group of experimental II group were fabricated with 0.2%, 0.3% wt. pigment mixing in silicone elastomer, respectively. Control group was kept in darkroom at room temperature, I-1 group was kept under natural sunlight during 1week, I-2 group was soaked in 20% soap water during 1wk. I-3 group was successively adhered and removed 200 times on inner region of arm using Daro adhesive-33. Experimental II groups were kept in darkroom at room temperature. Instron universal testing machine was used to measure the % elongation, tensile strength, tear strength of control, experimental I, II groups and reflectance spectrophotometer(COLOR EYE-3000, Macbeth, USA) was used to measure the color differences between control group and experimental I group. The results were as follows : 1. When compared with control group, natural weathering group and 20% soap-water soaking group had no significant differences in % elongation(p>0.05). 2. 200 times successive adhesion and removal group, 0.2% wt. pigment group and 0.3% wt. pigment group had significant decreases in % elongation(p<0.05). 3. Natural weathering group, 20% soap-water soaking group and 200 times successive adhesion and removal group had no significant differences in tensile strength (p>0.05). 4. 0.2%, 0.3% wt. pigment groups had significant decreases in tensile strength(p<0.05). 5. Values of all experimental groups were decreased in tear strength. and 200 times successive adhesion and removal group had significant decrease in tear strength(p<0.05). 6. Natural weathering group and 20% soap-water soaking group had significant color differences(${\Delta}E$) and it could be detectable to naked eye(p<0.05). 7. Color differences between control group and 200 times adhesion and removal group were not detectable to the naked eye (${\Delta}E<1.0$).

  • PDF

Physical Properties of Rice Hull and Straw for the Handling Facilities

  • Oh, Jae H.;Kim, Myoung H.;Park, Seung J.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.283-292
    • /
    • 1996
  • This study was performed to determine the physical properties of rice hull and straw which could be used for an optimum design and operation of the handling facilities for these rice crop by-products. The properties measured were kinetic friction coefficient , bulk density, and dynamic and static angle of repose. Rice hulls with moisture content of 13% and 21% were used throughout the test while rice straws of 10% and 16% moisture were chopped into 10mm length and used for the test. Friction coefficient was calculated from the horizontal traction forces measurement when a container holding the mass of rice hull and straw was pulled over mild steel. PVC, stainless steel, and galvanized steel surface by a universal testing machine. Bulk density was measured by an apparatus consisting of filling fundel and a receiving vessel. Dynamic angle of repose which is the angle at which the material will stand when piled was calculated from the photos of bulk samples after they were flowed by gravity and accumulated on a circular surface. Static angle of repose which is the angle between the horizontal and the sloping side of the material left in the container when discharging was also measured in the similar way. Results and conclusions from this study are summarized as follows . 1. Kinetic friction coefficient of both rice hull and straw were in the range of 0.26 -0.52 and increased with the moisture content. The magnitude of friction increased in the order of galvanized steel, stainless steel, PVC ,and mild steel. 2. Bulk densities of rice hull decreased while those of rice straw increased with moisture content increase . Average bulk densities of rice hull and straw were 96.8 and 74.7kg/㎥, respectively. 3. Average dynamic angle of repose for rice straw was 32.6$^{\circ}$ and those for 13% and 21% moisture rice hull were 38.9$^{\circ}$ and 44.9$^{\circ}$ , respectively. 4. Static angles of repose for both rice hull and straw showed increase with the moisture content. The values were 75.2\ulcorner and 80.2$^{\circ}$ for 13% and 21% moisture rice hull, respectively. Rice straws having 10% and 16% moisture content showed 87.3% and 89.2$^{\circ}$ static angle of repose, respectively.

  • PDF

Cooperative Multi-Agent Reinforcement Learning-Based Behavior Control of Grid Sortation Systems in Smart Factory (스마트 팩토리에서 그리드 분류 시스템의 협력적 다중 에이전트 강화 학습 기반 행동 제어)

  • Choi, HoBin;Kim, JuBong;Hwang, GyuYoung;Kim, KwiHoon;Hong, YongGeun;Han, YounHee
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.9 no.8
    • /
    • pp.171-180
    • /
    • 2020
  • Smart Factory consists of digital automation solutions throughout the production process, including design, development, manufacturing and distribution, and it is an intelligent factory that installs IoT in its internal facilities and machines to collect process data in real time and analyze them so that it can control itself. The smart factory's equipment works in a physical combination of numerous hardware, rather than a virtual character being driven by a single object, such as a game. In other words, for a specific common goal, multiple devices must perform individual actions simultaneously. By taking advantage of the smart factory, which can collect process data in real time, if reinforcement learning is used instead of general machine learning, behavior control can be performed without the required training data. However, in the real world, it is impossible to learn more than tens of millions of iterations due to physical wear and time. Thus, this paper uses simulators to develop grid sortation systems focusing on transport facilities, one of the complex environments in smart factory field, and design cooperative multi-agent-based reinforcement learning to demonstrate efficient behavior control.

Effective Frequency of External Feedback for Increasing the Percentage of Body Weight Loading on the Affected Leg of Hemiplegic Patients (편마비환자의 환측하지 체중부하율 향상을 위한 효과적인 외적 되먹임 빈도)

  • Noh, Mi-He;Yi, Chung-Hwi;Cho, Sang-Hyun;Kim, Tae-Ue
    • Physical Therapy Korea
    • /
    • v.5 no.3
    • /
    • pp.1-10
    • /
    • 1998
  • In motor learning, the relative frequency of external feedback is the proportion of external feedback presentations divided by the total number of practice trials. In earlier studies, increasing the percentage of body weight loading on the affected leg of hemiplegic patients, external feedback was continuously produced as the patient attempted to perform a movement. This feedback was produced to enhance the learning effect. However, recent studies in nondisabled populations have suggested that compared with 100% relative frequency conditions, practice with lower relative frequencies is more effective. My study compared the effect of 100% relative frequency conditions with 67% relative frequency conditions to determine what effect they exerted on motor learning for increasing the percentage of body weight loading on the affected lower limbs of patients with hemiplegia. Twenty-four hemiplegic patients were randomly assigned to one of two experimental groups. Each group practiced weight transfer motor learning on a machine. During practice, visual feedback was offered to all subjects. The experiment was carried out with full visual feedback for patients in group one but only 67% visual feedback for patients in group two. The percentage of loading on the affected leg was recorded four times: before learning (baseline value), immediately after learning, 30 minutes after learning, 24 hours after learning. The results were as follows: 1. In the 100% visual feedback group, the percentage of loading on the affected leg increased significantly in all three testing modes over the baseline value. 2. In the 67% visual feedback group, the percentage of loading on the affected leg increased significantly in all three measurements. 3. Immediately after learning, the learning effect was not significantly different between the two groups, but was significantly greater after both the 30 minutes delay and the 24 hours period. These results suggest that the 33% reduction in the provision of visual feedback may enhance the learning effect of increasing the percentage of body weight loading on the affected leg in patients with hemiplegia.

  • PDF

The Effects of the Total Patterns of Proprioceptive Neuromuscular Facilitation on Balance Improvement in Patients with Low back pain (고유수용성 신경근 촉진법 통합패턴이 요통환자의 균형에 미치는 영향)

  • Jung, Young-Jo;Bae, Sung-Soo
    • PNF and Movement
    • /
    • v.5 no.2
    • /
    • pp.73-88
    • /
    • 2007
  • Purpose : The purpose of this study was to find out The effect of Low back pain on the total pattens of Proprioceptive neuromuscular facilitation(PNF). Methods : The subjects of the study were 62 low back pain patients. They were divided into two groups: 31 in the experimental group and 31 in the control group. the experimental group performed modalities and PNF total patterns three times for a week. the control group performed only modalities and ROM exercise three times for a week. Back muscle strength was measured by a back muscle strength measuring machine, the intensity of pain was measured by the Visual Analogue Scale (VAS), and the level of disability was measured by Oswestry low back pain disability index. Study measurements were compared before and after 6 weeks exercise program. The two groups of subjects were assessed by utilizing two different balance measurement: Static standing balance was measured by balance performance monitor (BPM) and Dynamic standing balance was measured by one leg standing(OLS). The scale for static standing balance was measured by using, sway area, sway path, max velocity. Results : The results of this study were as follow: 1) The score on visual analogue scale shows statistically significant increase on PNF group of post test(p<.05). 2) The score on Oswestry low back pain disability index. shows statistically significant decrease on PNF group of post test(p<.05). 3) The change sway area was statistically significant on pre-test and post-test(p<.05). 4) The change sway path was statistically significant on pre-test and post-test(p<.05). 5) The change max velocity was statistically significant on pre-test and post-test(p<.05). 6) The score on one leg standing shows statistically significant increase on PNF group of post test(p<.05). Conclusion : These results of this study indicated that Proprioceptive Neuromuscular Facilitation Total patterns which performed for six weeks had a statistically significant influence on low back pain. If the exercise for muscle strength is performed along with therapeutic stabilizing exercise, a better effect can be expected on low back pain. We hope that this study will provide a basic data for further research with a bigger group and on a long-term effect.

  • PDF

Development of Oxo-biodegradable Transparent Bio Films Using Biomass and Biodegradable Catalyst (바이오매스 및 생분해 촉매제를 이용한 산화생분해 투명 바이오 필름 개발)

  • You, Young-Sun;Kim, Young-Tae;Park, Dae-Sung;Choi, Sung-Wook
    • Clean Technology
    • /
    • v.23 no.2
    • /
    • pp.133-139
    • /
    • 2017
  • Bio-based plastics containing the biomass content higher than 25 wt% have been considered as environment-friendly materials due to their effects on the reduction in the $CO_2$ emission and petroleum consumption as well as biodegradability after use. In this study, poly vinyl chloride, plant-derived plasticizers, by adding a biodegradable catalyst was observed a change in the biodegradability and physical properties. To produce the oxidative decomposition transparent bio film, which is broken down in the initial percent elongation and physical properties such as tensile strength, it was to test the safety of the product as a food packaging material. Poly vinyl chloride, primary plasticizer, secondary plasticizer, anti fogging agent, the combined stabilizer were mixed in a high speed mixer, then extruded using an extrusion molding machine, after cooling, winding, to produce a oxidative decomposition transparent bio film and the control film, with a thickness of $12{\mu}m$ through winder role. Mechanical properties tensile strength, elongation, and the maximum load elongation and biodegradation test. Transparent bio film produced by biodegradation catalyst is compared with the control film. Tensile strength and elongation of films were found to be no significant difference. Further, as a result of the biodegradation test for 45 days based on the ASTM D6954-04 method, biodegrability of film is 61.4%.

A Study on the Noxious Materials in the Waste Shipped into Solid Recovered Fuel(SRF) Facilities and Their Influence (고형연료(SRF)시설로 반입되는 폐기물의 영향 및 유해성물질 등에 관한 연구)

  • Lee, Seung-Won;Kim, Sang-Hun;Lee, Sang-Seok;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.27 no.2
    • /
    • pp.91-97
    • /
    • 2018
  • This study carried out first a component survey on the domestic waste shipped into a waste disposal facility in B city, and then heavy metal analysis of each component according to the SRF standards. Based on this, this study explored the problems with domestic waste and measures to improve them. The results are as follows. The result of the survey of physical components show that paper accounted for the largest proportion with 20.5 %~59.9 %, metals (including batteries) among incombustibles accounted for 0.0~8.3 %, other inorganic substances, glass and ceramics accounted for 0.0~43.7 % and 0.0 %~19.6 % respectively. However, the proportion of coated viny and plastics, which have high lead and cadmium content, was rather high with 2.9 %~30.9 %. This suggests the possibility that actual concentration of lead and cadmium within SRF is likely to be higher. Among the 15 components contained in the waste brought into the waste disposal facility, 10 components (food waste, textiles, vinyl, plastics, wood, rubber and leather, paper, metals, electronic substrates, and nail polish) were analyzed according to assay samples (approximately 0.1 g and 0.3 g). The result of analysis shows that the amount of Cd and Pb detected in coated vinyl for 0.109 g of assay sample was 98.6 mg/kg and 20.6 mg/kg respectively; 117.0 mg/kg and 29.0 mg/kg respectively for 0.313 g of assay sample. This is high contents exceeding the Cd standard. As for wooden component, the amount of Pb was 480.0 mg/kg for 0.3 g of assay sample. This suggests that there always exists the possibility of exceeding the exposure level of heavy metals (Cd and Pb) in SRF as long as coated wood and vinyl plastics with high contents of Pb and Cd are shipped into the waste disposal facility; and the local government and the residents need to work hard to improve the situation including development of the machine to sort electronic substrates and batteries for separate collection of the waste of coated vinyl and plastics within domestic waste.

Effects of Pre-Sintering Surface Treatment and Liner Application on the Shear Bond Strength of Zirconia and Pressable Ceramic (소결 전 지르코니아 표면처리와 라이너 사용에 따른 지르코니아와 열가압성형도재의 전단결합강도)

  • Lee, Gwang-Young;Cho, Mi-Hyang;Choi, Sung-Min
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.121-127
    • /
    • 2015
  • Purpose: This study was intended to investigate the effect of applying liner for chemical bonding and physical surface roughness created on zirconia by using a sandpaper before sintering on the bond strength between the two materials. Methods: Zirconia blocks were cut using a low-speed cutter. Plate-shaped specimen($6mm{\times}6mm{\times}3mm$) was fabricated by sintering after giving surface roughness according to four kinds of sandpapers. Depending on whether or not to use liner, 60 specimens were divided into two groups ZN(non-liner), ZL(liner), and the two groups were subdivided into four groups respectively in accordance with sandpaper used, totaling eight groups (n=10). The surface roughness (Ra) values and shapes before sintering were observed, and shear bond strength after pressing ceramic plasticity was measured with a universal testing machine. For a test of the significance, a one-way ANOVA was performed, and Tukey's multiple comparison test was conducted. Results: The observation of the surface roughness was SB04($2.22{\pm}1.16{\mu}m$), SB08($2.98{\pm}0.33{\mu}m$), SB12($2.44{\pm}1.32{\mu}m$), SB20($2.34{\pm}0.59{\mu}m$) and SA04($2.34{\pm}0.67{\mu}m$), SA08($1.28{\pm}0.90{\mu}m$), SA12($2.03{\pm}1.60{\mu}m$), SA20($2.19{\pm}1.73{\mu}m$). In the case of ZN Group, the shear bond strength was ZN04($23.26{\pm}3.83MPa$), ZN08($21.76{\pm}2.33MPa$), ZN12($20.49{\pm}3.01MPa$), ZN20($24.98{\pm}4.22MPa$)(p<0.05). As for ZL Group, the shear bond strength was ZL04($25.09{\pm}5.67MPa$), ZL08($22.98{\pm}2.26MPa$), ZL12($21.54{\pm}5.70MPa$), ZL20($23.98{\pm}3.23MPa$)(p<0.05). Conclusion: The research results showed that the bond strength of Zirconia core and Pressing ceramic was further improved by physical surface treatment before sintering, rather than by chemical bonding through liner surface treatment.

A Study on Development of Eco-friendly Wrap using Biodegradable Resin (생분해성 수지를 이용한 환경친화성 랩 개발에 관한 연구)

  • Lim, Mi-Jin;Sim, Jae-Ho;Choi, Jong-Moon;Kim, Young-Sik
    • Applied Chemistry for Engineering
    • /
    • v.16 no.6
    • /
    • pp.800-808
    • /
    • 2005
  • The compounding resin for biodegradable wrap was developed, and its manufacturing process and physical properties were studied. For these purposes, following factors were optimized: the types and amounts of raw resin material, anti-oxidants, and lubricants used. In this work, the stable compounding resin used to make biodegradable wrap was based on poly(butylene adipate-co-butylenesuccinate) (PBAS) and poly(butyleneadipate-co-butylene succinate-co-butyleneterephthalate) (PBAST). The improved properties of resin with an additive were investigated by melting flow index (MFI). From these results, the physical properties of compounding resin, based on PBAST, were more than those of PBAS. For PBAS, the Irganox 1010, 1076 and Irgafos TNPP as the first and second anti-oxidants, respectively, were good. For PBAST, the good first and second anti-oxidants, respectively, were Irganox 1076 and Mark PEP 36. The good lubricants for feeding PBAS and PBAST were glycerol monostearate and palmityl alcohol, respectively. The stability and tensile strength experiment of wrap were also investigated by the elution of heavy metals and universal testing machine (UTM), respectively. The decomposition ratio of developed wrap was increased proportional to the reclaiming time. The degradation ratio of compounding resin sample was about 60% after 40 days.

A STUDY ON BONE STRENGTH AND THE DEGREE OF CONVERSION OF DENTIN BONDING AGENTS (수종 상아질 접착제의 결합강도와 중합률에 관한 연구)

  • Kim, Byung-Hyun;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.68-93
    • /
    • 1998
  • The physical properties of polymer are greatly influenced by the extent to which a resin cures. The presence of un reacted monomer can, have a plasticizing effect on the polymer, thereby altering the physical and mechanical properties of dentin bonding agent (DBA). If the DBA does not polymerize sufficiently, it will leave a weak bonding layer and lead to lower bond strength. The purpose of this study was to evaluate the shear bond strengths(SBS) and the degree of conversion (DC) of 4 commercialy avilable dentin bonding systems which are composed of 2 multi-bottle systems [Scotchbond Multi-Purpose (SMP), AeliteBond(AB)] and 2 onebottle systems [SingleBond(SB), One-Step(OS)]. For shear bond strength measurement, labial surfaces of freshly extracted bovine incisors were ground with # 600 grit SiC paper to expose dentin. Four different groups of samples were formed, with 10 samples. being made for each of the 4 commercial DBA in each group according to the curing sequences of DBA and overlayer thickness of composites: Group I (standard cure and 1mm thick composites) : The DBA was light cured and the composites of 1mm thickness was applied ; Group II (standard cure and 2mm thick composites) : The DBA was light cured and the composites of 2mm thickness was applied; Group III (simultaneous cure and 1mm thick composites) : The DBA was not light-cured and simultaneously cured with composites of 1mm thickness; Group N (simultaneous cure and 2mm thick composites) : The DBA was. not light-cured and simultaneously cured with composites of 2mm thickness. The SBS was measured immediately after the composites was bonded to the bovine dentin using an Instron machine. The DC of the DBA was examined in a thin film under simulated conditions of the experimental groups according to the curing sequences and overlayer thickness of composites in the SBS test. using a Fourier transform Infrared(FTIR) spectrometer. The following results were obtained from SBS tests and DC measurements 1. In SBS tests, the multi-bottle DBA(SMP, AB) had a generally higher bond strength values than the one bottle DBA(SB, OS). In DC measurements, the one bottle DBA(SB, OS) had a significantly higher DC than the multi-bottle DBA(SMP, AB). 2. In all DBAs except OS, there was no significant difference between the bond strength of group I (standard cure and 1mm thick composites) and that of group III (simultaneous cure and 1mm thick composites). SMP, SB in Group I had a significantly higher DC than those in group III, but AB, OS in group I had a significantly lower DC than those in group III 3. All DBAs in Goup II (standard cure and 2mm thick composites) had significantly higher bond strength and DC than those in Group N (simultaneous cure and 2mm thick composites). 4. In all DBAs, there was no significantly different SBS and DC between Group I and Group II, but all DBAs in Group III had significantly higher SBS and DC than those in Group IV.

  • PDF