• Title/Summary/Keyword: Physical Machine

Search Result 838, Processing Time 0.03 seconds

The Usefulness of Ultrasound Diagnosis of Acute Tendon Injury in Hand (급성 건 손상 환자에서 초음파의 유용성)

  • Choi, Chang Yong;Lee, Han Jeong;Choi, Hwan Jun;Kim, Mi Sun
    • Archives of Plastic Surgery
    • /
    • v.35 no.6
    • /
    • pp.729-734
    • /
    • 2008
  • Purpose: The evaluation and management of a completely transected tendon of the hand is relatively clear. In most cases, the integrity is assessed by physical examination(eg, broken normal cascade, motion loss) but occasionally, It happens in troubles. because of pain, limited patient cooperation(eg, child, unconscious patient), and other associated injuries(eg, fractures, foreign bodies). Methods: From september 2006 to August 2007, 28 patients were evaluated with real time ultrasonography preoperatively and postoperatively. Twenty eight patients with injured tendon were evaluated using an HDI 5000 Sono CT(Philips Medical Systems, Bothell, WA) machine with a high resolution, 7.5MHz hockey stick linear probe. Dynamic evaluation was performed in real time. Results: Surgery was performed after the ultrasonographic evaluation. Sonographic diagnosis and intraoperative findings were correlated. Ultrasonographic findings show tendon discontinuity, gaps, and fluid collection. Conclusion: We conclude that ultrasonography is helpful in evaluating and managing acute tendon injury. Especially, in cases of completely lacerated tendon, ultrasonography can identify the location of the proximal tendon stump and partial lacerated tendon, ultrasonographic diagnostic tool can decrease misdiagnosis.

AN EXPERIMENTAL STUDY ON THE PHYSICAL PROPERTIES OF DENTURE BASE RELINERS (의치상 재이장재의 물리학적 성질에 관한 연구)

  • Kwon, Yong-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.193-202
    • /
    • 1990
  • The purpose of this study was to compare the fithness, hardness and bending strength of the conventional reliners and visible light curing reliner. Nine regions were selected in the upper transverse section which were thought to be of interest from a clinical standpoint and the discrepancies between the dentures and the master cast in these regions were determined by the coordinated measuring machine(UMM-500, Zeiss, W. Germany). The results were as follows ; 1. The experimental denture bases showed the lowest fittness at the central portion of the posterior palatal border and the intimate contact in the buccal flanges regardless of relining materials and relining methods. 2. The fittness of relined denture base was the best in autopolymerizing group and in the order of long processing, short processing and visible light curing group. 3. The fittness after 24 hour-storage in water was improved in long processing and autopolymerizing groups, but there was no significant difference. 4. The hardness was the highest in long processing group and decreased in the order of short processing, visible light curing and autopolymerizing group. 5. The bending strength was the highest in long processing group and decreased short processing, visible light curing, and aotopolymerzing group in order.

  • PDF

Fabrication and Characteristics of Chitosan Non-woven Fabric developed using only water as plasticizer

  • Lee, Shin-Hee;Hsieh, You-Lo
    • Fashion & Textile Research Journal
    • /
    • v.16 no.2
    • /
    • pp.319-325
    • /
    • 2014
  • This article describes a method for producing chitosan non-woven fabrics by just hot pressing without the use of a binder. A study has been made of the wet spinning of chitosan fiber. The fibers were rinsed thoroughly in running water and chopped wet into staples of with a length of approximately 5-10 mm. The chopped chitosan staples were dispersed uniformly in water and fabricated using a non-woven making machine. This study examined the formation and the characteristics of chitosan non-woven fabrics manufactured by hot pressing without the use of a binder. The effects of the non-woven fabrication conditions on the thermal, morphological, structural, and physical properties of chitosan non-woven fabric with and without water as a plasticizer were studied. The temperature of the exothermic peak, decomposition of chitosan fibers increased with increasing heating rate. Water in the chitosan fiber effectively plasticized the chitosan fiber. The thermal bonded structure of the wet chitosan fiber with water as a plasticizer was clearly found in many parts of the non-woven fabric at a fabrication temperature of $200^{\circ}C$. The intensity and profile of the (100) plane($2{\theta}=10.2^{\circ}$) and (040) plane($2{\theta}=20.9^{\circ}$) in the chitosan non-woven fabric decreases and became smooth in the non-woven fabric formation by melting.

Energy-Aware Virtual Data Center Embedding

  • Ma, Xiao;Zhang, Zhongbao;Su, Sen
    • Journal of Information Processing Systems
    • /
    • v.16 no.2
    • /
    • pp.460-477
    • /
    • 2020
  • As one of the most significant challenges in the virtual data center, the virtual data center embedding has attracted extensive attention from researchers. The existing research works mainly focus on how to design algorithms to increase operating revenue. However, they ignore the energy consumption issue of the physical data center in virtual data center embedding. In this paper, we focus on studying the energy-aware virtual data center embedding problem. Specifically, we first propose an energy consumption model. It includes the energy consumption models of the virtual machine node and the virtual switch node, aiming to quantitatively measure the energy consumption in virtual data center embedding. Based on such a model, we propose two algorithms regarding virtual data center embedding: one is heuristic, and the other is based on particle swarm optimization. The second algorithm provides a better solution to virtual data center embedding by leveraging the evolution process of particle swarm optimization. Finally, experiment results show that our proposed algorithms can effectively save energy while guaranteeing the embedding success rate.

DEVELOPMENT OF A GARLIC CLOVE PLANTER

  • Park, W.K.;Kim, Y.K.;Choi, D.K.
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2000.11b
    • /
    • pp.438-445
    • /
    • 2000
  • Positioning garlic cloves in upright standing in garlic field has been regarded as a very important job because it affects clove rooting, growing and, eventually, quality and yield in garlic production, Because of the geometrical uniqueness and irregularity of garlic cloves in shape, the planting operation has been conducted by manual work that needs a tremendous human labors and increases garlic production cost. The overall objective of this research was to develop garlic planting machine through investigating physical properties of garlic and designing clove upright positioning device after figuring out the factors affecting metering device and upright clove positioning mechanism. With the outcomes of the metering and posture positioning experiment, a garlic clove planter having twelve planting rows was developed for 37kW type tractor and feasibility test was carried out in the field. And, According to the performance test and cost analysis, the planter could accomplish planting operation of one hectare plot in 6.3 hours giving 48 times better efficiency, 6.3hrs/ha, and 74.2% of production cost reduction effect, 1,092,546won/ha, than the manual works of 299hrs/ha and 282,258won/ha. And, break-even point ofthe planter was calculated as of 2.71 hectares.

  • PDF

A Study of the Boring Bar Vibration Measurement using Optical Fiber Sensor (보링바 고유진동 계측을 위한 광섬유 진동센서 연구)

  • Song, Doo-Sang;Hong, Jun-Hee;Jeong, Hwang-Young;Kang, Dae-Hwa;Kim, Byung-In
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.4
    • /
    • pp.107-113
    • /
    • 2009
  • In this paper, we studied of measurement the vibration of natural frequency using optical fiber sensor. The boring bar for measurement of vibration in use optical fiber sensor has the advantage of direct measure for the frequency than accelerometer. Because it deal with output value on electrical signal of optical fiber in physical disturbance when it measures the frequency of vibration. The optical fiber sensor measured the vibration of boring bar by the gap in sensing jig while optical fiber just kept contact with boring bar. A prototype system was composed of jig part with gap and optical system part. In this paper, we found out the possibility to measurement of vibration by the gap in use optical fiber.

Basic Design and Structural and Optical Glass Characteristic Study of Chalcogenide Aspheric Lens (칼코게나이드계 비구면 성형렌즈의 기초설계 및 구조적, 광학적 글래스 특성 연구)

  • Ko, Jun-Bin;Kim, Jeong-Ho;Byun, Dong-Hae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.27 no.5
    • /
    • pp.69-74
    • /
    • 2010
  • An increasing interest towards the investigations of chalcogenide glasses has been observed in the past years. This interest is due to their specific properties, as well as to the possibilities for their application in different fields of science. The optical devices, working on the basis of photoinduced phase transition between amorphous and crystalline state in the chalcogenide glasses, are a perspective for the micro- and nano-electronics. Here we were analysis basic physical properties for Ge-As-Se and As-Se chalcogenide glasses samples for characteristic for a planning of chalcogenide aspheric lens. From differential DTA/TG results, activation energies of the crystallizations of $Ge_{10}As_{40}Se_{50}$ and $As_{40}Se_{60}$ were approximately 3.6 eV and 3.3 eV, respectively.

A Study on Synthesis and Characteristics of The Optimum Rolling Bearing Greases (최적 베어링 윤활 그리이스의 합성과 특성연구)

  • Kim Sang-Keun;Park Chang-Nam;Han Jong-Dae;Son Gwan-Su
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.129-138
    • /
    • 2003
  • Rolling bearings are classified one of the most important machine elements. The various function of bearings are greatly influenced by grease, and higher performance of rolling bearing greases is required in improve bearing lubrication. Three urea/ether oil greases with identical composition were synthesized to compare the performance of these greases according to the thickener content of grease. The typical grease physical properties were investigated. And life test of these greases was conducted by FE-9 grease life tester. The characteristics of the greases before and after life test were investigated using FT-IR, microscope, OIT and TAN meter. Large differences in the grease performance depending on the content of the thickener were observed. The grease with higher content of the hickener showed higher performance such as long life time and low TAN value. After preliminary test, twelve greases were synthesized and evaluated the performance of dropping point and OIT, then optimized two greases were selected by SSRED (Six Sigma Robust Engineering Design) using dropping point and OIT data. Characteristics of the optimized two greases were on the same level with estimated value. The optimized grease by means of OIT value showed longer grease life in comparison with optimized grease by dropping point. However two greases showed higher performance than typical urea/ether oil.

  • PDF

Measurement of Nonlinear Time-variant Source Characteristics of Intake and Exhaust Systems in Fluid Machines

  • Jang Seung-Ho;Ih Jeong-Guon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.3E
    • /
    • pp.87-89
    • /
    • 2005
  • The acoustical sources of intake and exhaust systems in fluid machines are often characterized by the source impedance and strength using linear frequency-domain modeling. In the case of the sources which are nonlinear and time-variant, however, the source parameters were sometimes incorrectly obtained. In this paper, the source model and direct measurement technique are modified in order to evaluate the effect due to nonlinear and periodically time-varying source character as well as the linear property of the reflectivity of in-duct fluid machine source. With a priori known kinematical information of the source, the types of nonlinear time-variant terms can be presumed by a simple physical model, in which there is practically no restriction on the form of the model. The concept of source impedance can be extendable by introducing the linear frequency response function for each nonlinear or time-variant input. Extending the conventional method and adapting the reverse MISO technique, it is possible to develop a direct method that can deal with the nonlinear time-variant source parameters. The proposed direct method has a novel feature that there is no restriction on the probability or spectral natures of the excited sound pressure data. The present method is verified by the simulated measurements for simplified fluid machines. It is thought that the proposed method would be useful in predicting the insertion loss or the radiated sound level from intake or exhaust systems.

EFFECTIVE DOSE MEASUREMENT FOR CONE BEAM COMPUTED TOMOGRAPHY USING GLASS DOSIMETER

  • Moon, Young Min;Kim, Hyo-Jin;Kwak, Dong Won;Kang, Yeong-Rok;Lee, Man Woo;Ro, Tae-Ik;Kim, Jeung Kee;Jeong, Dong Hyeok
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.255-262
    • /
    • 2014
  • During image-guided radiation therapy, the patient is exposed to unwanted radiation from imaging devices built into the medical LINAC. In the present study, the effective dose delivered to a patient from a cone beam computed tomography (CBCT) machine was measured. Absorbed doses in specific organs listed in ICRP Publication 103 were measured with glass dosimeters calibrated with kilovolt (kV) X-rays using a whole body physical phantom for typical radiotherapy sites, including the head and neck, chest, and pelvis. The effective dose per scan for the head and neck, chest, and pelvis were $3.37{\pm}0.29$, $7.36{\pm}0.33$, and $4.09{\pm}0.29$ mSv, respectively. The results highlight the importance of the compensation of treatment dose by managing imaging dose.