• Title/Summary/Keyword: Photovoltaic system, PV system

Search Result 971, Processing Time 0.031 seconds

실측데이터를 이용한 에너지제로주택의 연간 에너지성능평가 (Annual Energy Performance Evaluation of Zero Energy House Using Metering Data)

  • 임희원;윤종호;신우철
    • KIEAE Journal
    • /
    • 제16권3호
    • /
    • pp.113-119
    • /
    • 2016
  • Purpose: In this study, we evaluate the annual energy performance of the detached house which was designed with the aim of zero energy. Method: The experimental house which was constructed in Gonju Chungnam in 2013, is the single family detached house of light weight wood frame with $100m^2$ of heating area. Thermal transmittance of roof (by ISO 10211) and building external walls are designed as $0.10W/m^2K$ and $0.14W/m^2$ respectively and low-e coating vacuum window glazing with PVC frame was installed. Also grid connected PV system and natural-circulation solar water heater was applied and 6kWp capacity of photovoltaic module was installed in pitched roof and $5m^2$ of solar collector in vertical wall facing the south. We analyzed the 2014 annual data of the detached house in which residents were actually living, measured though web-based remote monitoring system. Result: First, as a result, total annual energy consumption and energy production (PV generation and solar hot water) are 7,919kWh and 7,689kWh respectively and the rate of energy independence is 97.1% which is almost close to the zero energy. Second, plug load and hot water of energy consumption by category showed the highest numbers each with 33% and 31%, with following space heating 24%, electric cooker 8%, lighting 3% in order. Hot water supply is relatively higher than space heating because high insulation makes it decreased.

I-V 특성곡선을 통한 태양전지 패널의 모델 파라미터 추출 방법 (Analytical Methods for the Extraction of PV panel Single-Diode model parameters from I-V Characteristic)

  • 최성원;류지형;이창구
    • 한국산학기술학회논문지
    • /
    • 제12권2호
    • /
    • pp.847-851
    • /
    • 2011
  • 태양광 발전 시스템은 친환경성을 바탕으로 설치용량이 증가하고 있으며 효율 개선을 위한 연구가 활발하다. 고 효율 시스템 설계를 위해서는 태양전지 패널의 출력특성을 정확히 파악하는 것이 중요하다. 태양전지 패널은 단일 다이오드 모델로 물리적 특성을 표현할 수 있으나, 정확한 파라미터를 얻는 것은 여러 단계의 측정과 수치해석 등의 복잡한 과정을 거쳐야 한다. 본 논문에서는 패널 제조사의 데이터 시트에 제공되는 태양전지 패널의 I-V 특성곡선을 기반으로 패널의 단일 다이오드 모델의 특성 파라미터를 추출하는 방법을 제시하였다. 제시한 방법의 검증을 위하여, Simulink의 Solar Cell 블록에 추출한 파라미터를 입력하여 출력을 측정하고, 데이터 시트와 오차를 계산하였다.

Utility Interactive Solar Power Conditioner with Zero Voltage Soft Switching High frequency Sinewave Modulated Inverter Link

  • Terai H.;Sumiyoshi S.;Kitaizumi T.;Omori H.;Ogura K.;Chandhaket S.;Nakaoka M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.668-672
    • /
    • 2001
  • The utility interactive sinewave modulated inverter for the solar photovoltaic (PV) power conversion and conditioning with a new high frequency pulse modulated link is presented for domestic residential applications. As compared with the conventional full-bridge hard switching PWM inverter with a high frequency AC link, the simplest single-ended quasi-resonant soft switching sinewave modulated inverter with a duty cycle pulse control is implemented, resulting in size and weight reduction and low-cost. This paper presents a prototype circuit of the single-ended zero voltage soft switching sinewave inverter for solar power conditioner and its operating principle. In addition, this paper proposes a control system to deliver high quality output current. Major design of each component and the power loss analysis under actual power processing is also discussed from an experimental point of view. A newly developed interactive sinewave power processor which has $92.5\%$ efficiencty at 4kW output is demonstrated. It is designed 540mm-300mm-125mm in size, and 20kg in weight.

  • PDF

지붕형 태양광 발전량 산정을 위한 서울지역 그림자 효과 분석 (Analysis of Shadows Effect in Seoul Area for the Estimation of Roof-type PV Power Calculation)

  • 윤창열;정보린;김신영;김창기;김진영;김현구;강용혁;김용일
    • 한국태양에너지학회 논문집
    • /
    • 제38권2호
    • /
    • pp.45-53
    • /
    • 2018
  • For the preliminary step for estimating the performance of roof-type photovoltaic system in urban areas, we analyzed the solar radiation reduction ratio by shadow effect by buildings using DSM (Digital Surface Model) and GIS (Geographical Information System) tools. An average loss by the shadow is about 19% in Seoul. The result was related to the building density and distribution. Monthly results show that the winter season (December and January) was more affected by the shading than during the summer season (June and July). It is expected that useful empirical formulas can be made if more detailed correlation studies are performed.

태양광시스템 모델식과 기계학습을 이용한 발전성능 추정 (Estimation of Power Using PV System Model Formula and Machine Learning)

  • 오현규;신우균;주영철;배수현;황혜미;강기환;고석환;장효식
    • Current Photovoltaic Research
    • /
    • 제11권1호
    • /
    • pp.27-33
    • /
    • 2023
  • In this paper, a machine learning model by using a regression algorithm is proposed to estimate the power generation performance of the BIPV system. The physical model formula for estimating the generation performance and the proposed model were compared and analyzed. For the physical model formula, simple efficiency model, temperature correction model, and regressive physics model for changing an irradiance were used. As a result, when comparing the regressive physics model for changing an irradiance and the proposed model with the actual generation measured data, the respective RMSE values are 0.1497 kW, 0.0451 kW and the accuracy values are 86.44%, and 96.56%. Therefore, the proposed model implemented in this experiment can be useful in estimating power generation.

표준기상 데이터와 열해석을 이용한 태양광열 모듈의 필요 냉각수량 산출 (Calculation of Required Coolant Flow Rate for Photovoltaic-thermal Module Using Standard Meteorological Data and Thermal Analysis)

  • 이천규;정효재
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.18-22
    • /
    • 2022
  • Photovoltaics (PV) power generation efficiency is affected by meteorological factors such as temperature and wind speed. In general, it is known that the power generation amount decreases because photovoltaics panel temperature rises and the power generation efficiency decreases in summer. Photovoltaics Thermal (PVT) power generation has the ad-vantage of being able to produce heat together with power, as well as preventing the reduction in power generation efficien-cy and output due to the temperature rise of the panel. In this study, the amount of heat collected by season and time was calculated for photovoltaics thermal modules using the International Weather for Energy Calculations (IWEC) data provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Based on this, we propose a method of predicting the temperature of the photovoltaics panel using thermal analysis and then calculating the flow rate of coolant to improve power generation efficiency. As the results, the photovoltaics efficiencies versus time on January, April, July, and October in Jeju of the Republic of Korea were calculated to the range of 15.06% to 17.83%, and the maxi-mum cooling load and flow rate for the photovoltaics thermal module were calculated to 121.16 W and 45 cc/min, respec-tively. Though this study, it could be concluded that the photovoltaics thermal system can be composed of up to 53 modules with targeting the Jeju, since the maximum capacity of the coolant circulation pump of the photovoltaics thermal system applied in this study is 2,400 cc/min.

데이터를 활용한 태양광 발전 시스템 모듈온도 및 발전량 예측 (Prediction of module temperature and photovoltaic electricity generation by the data of Korea Meteorological Administration)

  • 김용민;문승재
    • 플랜트 저널
    • /
    • 제17권4호
    • /
    • pp.41-52
    • /
    • 2021
  • 본 연구에서는 태양광발전 출력 및 모듈온도 값을 기상청 데이터를 이용하여 예측해보고 실측 데이터와 날씨, 일사량, 주변온도, 풍속별로 비교 분석해보았다. 날씨별 예측정확도는 눈이 오거나, 새벽에 해무가 끼는 날의 데이터를 가장 많이 보유한 맑은날의 데이터의 예측정확도가 가장 낮았다. 일사량에 따른 모듈온도와 발전량의 예측정확도는 일사량이 커질수록 정확도가 떨어졌으며, 주변 온도에 따른 예측정확도는 모듈온도는 주변 온도가 커질수록, 발전량은 주변온도가 낮을수록 예측정확도가 떨어졌다. 풍속은 모듈온도와 발전량 모두 풍속이 높아질수록 예측정확도가 감소하였지만, 풍속이 영향 다른 기상조건에 의한 영향보다 미미하여 그 상관관계를 정의하기가 어려웠다.

온실가스감축효과를 고려한 태양광 연계형 에너지저장장치(ESS) 보급전략에 대한 연구 (A Research on PV-connected ESS dissemination strategy considering the effects of GHG reduction)

  • 이원구;김강원;김발호
    • 에너지공학
    • /
    • 제25권2호
    • /
    • pp.94-100
    • /
    • 2016
  • 에너지저장장치(ESS)는 전력수급 불균형 해소, 신재생에너지의 출력안정, 주파수 조정용 등 전력공급 안정성 향상 및 효율적 전기에너지사용 등에 기여하는 중요자원으로, 전세계적으로 '23년까지 '14년 설치용량의 약 30배가 증가한 55.9GWh의 보급이 전망되고 있다. 이와 같이 급증하는 세계시장에서 국내 ESS 업계의 경쟁력 확보를 위해서는 자국내 설치실적(Track Record) 확보가 필요한데, 우리나라는 주파수 조정용(FR용(用))과 그간 지속되어 왔던 전력수급 불균형 상황에 대비하기 위한 부하이동용 중심으로 ESS를 보급하여 왔다. 하지만, 주파수 조정용의 경우 통상적으로 화력발전소 정격용량의 약 5% 범위에서 설치효용이 발생하는 것으로 평가되고 있어, 화력발전이 비약적으로 증가하지 않는 한 국내 시장의 확장성이 부족하다고 할 수 있으며, 여유로운 예비력 확보정책에 따라 부하이동용에 대해서도 보급필요성이 저하되고 있는 바, 새로운 방식의 보급확대 대상이 필요하다고 할 수 있다. 유망한 신규보급대상은 간헐적 출력의 약점은 있으나, 신기후체제 대응과 산업육성을 위해 지속적으로 추진예정인 신재생에너지와의 연계설치를 통해 신재생에너지의 출력을 안정화 하고, 신재생에너지 발전량의 계통투입시기 조절을 통한 이산화탄소 저감효과를 기대할 수 있는 분야라고 할 수 있다. 본 연구에서는 향후 에너지정책의 최대 화두인 신기후체제 대응을 위한 온실가스 감축수단을 활용할 수 있도록, 태양광 연계형 ESS 충방전모드를 온실가스 저감효과를 고려토록 설계한 후, 투자유도를 위한 REC 가중치 산정방법에 대한 정책대안을 제시하였다.

EV용 이동형 전원공급장치의 구현 및 경제성 평가에 관한 연구 (Implementation and Economic Evaluation of Movable Power Supply Device for Electric Vehicle)

  • 최성문;한병길;이후동;김미영;노대석
    • 한국산학기술학회논문지
    • /
    • 제21권12호
    • /
    • pp.77-86
    • /
    • 2020
  • 기존의 고정형 EV(electric vehicle) 충전기는 이용률이 증가하게 되면 충전 인프라 설비 부족으로 인해 사용자의 충전 대기시간이 길어지는 불편함이 발생할 수 있고, EV 충전기를 증설하는 경우, 배전선로(지중) 증설비용 및 선로의 전압강하로 인한 전력품질 문제가 발생할 수 있다. 따라서, 본 논문에서는 상기의 문제점을 해결하고, EV 충전기 부족으로 인한 불편함을 해결할 수 있는 EV용 이동형 전원공급장치(movable power supply device, MPSD)를 제안한다. 제안한 MPSD는 태양광전원부, 에너지저장부, EV용 충전기부, 감시제어부로 구성되고, 사용자의 환경요소에 따라 MPSD를 유연하게 이용할 수 있도록 3가지 운용모드로 나눌 수 있다. 또한, 경제성 평가 모델링을 비용요소와 편익요소로 구분한다. 여기서, MPSD의 비용요소로는 태양광전원부, 에너지저장부, EV 충전기부, 감시제어부의 설비비용과 기존의 EV 충전기 설비비용, 배전선로 증설비용, 기존의 EV 충전기 운용비용등의 편익요소로 구성되며, 이를 바탕으로 현재 가치 환산법을 사용하여 경제성을 평가한 결과, MPSD가 기존의 고정형 EV 충전기보다 유리함을 알 수 있었고, 설치지점의 거리에 따라 편익이 크게 좌우함을 확인하였다.

실측데이터를 이용한 저에너지주택의 에너지성능평가 (Energy Performance Evaluation of Low Energy Houses using Metering Data)

  • 백남춘;김성범;오병칠;윤종호;신우철
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).