• Title/Summary/Keyword: Photovoltaic System Analysis Program

Search Result 36, Processing Time 0.03 seconds

The Development of Performance Evaluation Program of Building Integrated Photovoltaic System (건물일체형 태양광발전 시스템 성능평가 프로그램 개발)

  • Kim, Beob-Jeon;Park, Jae-Wan;Yoon, Jong-Ho;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.85-90
    • /
    • 2015
  • Purpose: In design and planning Building Integrated Photovoltaic(BIPV) system can reduce cost by replacing building facade as construction material such as roofs, outer walls and windows as well as generating electricity. BIPV system should be applied at the early stage of architectural design. However, it is hard to decide whether using BIPV system or not for architects and builders who are not professional at BIPV system because performance of system is considerably influenced by types of module, installation position, installation methods and so on. It is also hard for experts because commercialized analytical program of photovoltaic systems is too complicated to use and domestic meteorological data is limited to partial areas. Therefore, we need evaluation program of BIPV system which can easily but accurately interpret generating performance and evaluate validity of BIPV system at the early stage of architectural design even for inexpert. Method: In this study, we collected meteorological data of domestic major region and analyzed generation characteristic of BIPV system by using PVsyst(commercialized software) in accordance with regions, types of solar module, place and methods of installation and so on. Based on this data, we developed performance evaluation program of BIPV system named BIPV-Pro, through multiple regression analysis and evaluated its validity. Result: When comparing predictive value of annual average PR and annual electricity production of BIPV-Pro an that of PVsyst, each of root mean square error was 0.01897 and 123.9.

Software Development on Power and Economic Analysis of Photovoltaic System for Building Application (건물용 태양광발전 시스템 성능 및 경제성 평가 프로그램 개발 연구)

  • Yoon, Jong-Ho;Shin, U-Cheul;Park, Jae-Wan
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • The aim of this study is to develop the photovoltaic simulation program, called SimPV, which can Predict hourly based power generation of various PV modules and conduct an intensive economic analysis with Korean situation. To establish the reliability of the PV simulation results, we adopt the PV calculation algorithm of TRNSYS program of which verification has already well approved. Extensive database for hourly weather data of Korean 16 cities, engineering data for PV system and building load profiles are established. Case study on the 2.5kW roof integrated PV system and economic analysis are presented with the developed program.

A Study on the Power Quality of the Grid connected Photovoltaic Power System (계통 연계형 태양광 발전시스템의 전력품질에 관한 연구)

  • Choi, Hyoung-Bum;Kim, Kyung-Chul;Hwang, Young-Rok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.8
    • /
    • pp.88-98
    • /
    • 2011
  • Development and use of renewable energy due to environmental problems and depletion of energy affect grid-connected power system around the world. Therefore this paper analyzes the characteristic of gird connected photovoltaic power generation system which it is available to connect the utility. Renewable energy photovoltaic power system has been linked to the system to analyze the impact of photovoltaic system. MATLAB / Simulink program is modeled and analyzed on power quality of a photovoltaic power plant. It is measured that power data for the Grid connected photovoltaic power plant with instantaneous measuring, 3sec measuring, 10min measuring for 7 days. Harmonic field measurement have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. so, it is used 50[%] cumulative probability approach. This paper provides an in depth analysis on power quality field measurement of the Grid connected photovoltaic power plant.

Impact Analysis of a Grid-connected Photovoltaic system on High Impedance Fault (고저항 지락사고에 대한 태양광 발전의 영향분석)

  • Kim, Sang-Hyub;Seo, Hun-Chul;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.476_477
    • /
    • 2009
  • This paper compares the several cases with High Impedance Fault(HIF) conditions and analyzes the impact of the grid-connected photovoltaic system at the HIF conditions. Simulations are conducted by using Electro-Magnetic Transient Program (EMTP) and using the results, the analysis is presented.

  • PDF

Photovoltaic Generation System Simulation using Real Field Weather Conditions

  • Park, Min-Won;Yu, In-Keun
    • Journal of IKEEE
    • /
    • v.5 no.2 s.9
    • /
    • pp.121-127
    • /
    • 2001
  • Actual system apparatuses are necessary in order to verify the efficiency and stability of photovoltaic(PV) generation systems considering the size of solar panel, the sort of converter type, and the load conditions and so on. Moreover, it is hardly possible to compare a certain MPPT control scheme with others under the exactly same weather and load conditions as well. For the purpose of solving above mentioned difficulties in a laboratory basis, a transient simulation of PV generation system using real field weather conditions is indispensable. A straightforward simulation scheme with cost effective hardware structures under real weather conditions is proposed in this paper using EMTDC type of transient analysis simulators. Firstly, a solar cell has been modeled with VI characteristic equations, and then the real field data of weather conditions are interfaced to the EMTDC through Fortran program interface method. As a result, the stability and the efficiency analysis of PV generation systems according to various hardware structures and MPPT controls are easily possible under the exactly same weather conditions.

  • PDF

A Case Study on Malfunction of OCGR and Inaccuracy of Watt-hour Meter in Distributed Generation System (분산형 발전고객의 OCGR오동작 및 과부족 계량에 대한 사례연구)

  • Shin, Dong-Yeol;Park, Yong-Woo;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1349-1355
    • /
    • 2008
  • The paper shows the analysis of operating conflict of OCGR trip events and metering errors in the photovoltaic generation, wind generation distributed generation customers with no defect of the distributed generation facilities, which are connected to 22.9kV distribution lines. To analyze problems with metering errors and OCGR fault event, a power quality analyzer and PSIM program were used to test the field and to simulate in Sun-Cheon photovoltaic generation and Seo-Cheon photovoltaic generation customers. With the trial distribution line, the result of analysis was verified to prove with the same situation of the actual field. This paper suggests short term and long term countermeasures of OCGR fault events, analysis of over and shortage of metering errors in distributed generation customers.

A Review on the Agri-voltaic and Fence PV System

  • Hasnain, Yousuf;Lee, Koo;Young Hyun, Cho
    • Current Photovoltaic Research
    • /
    • v.10 no.4
    • /
    • pp.116-120
    • /
    • 2022
  • Solar energy is rapidly being utilized to generate power in Europe and other countries, but the environmental effect of building and operating solar farms is not fully understood. The building of a solar park demands the removal of certain vegetation and the leveling of the land. Solar energy infrastructure may involve considerable landscape change, altering soil biological processes and influencing hydrologic, carbon and vegetative dynamics. To rebuild the solar PV facilities soils, inherent plant fields might require to be re-established. Within the scope of this research, we presented an analysis of the effects that were caused by the solar farm.

Analysis of the Effect of the Grid-connected Photovoltaic System in Fault Case of Power System (전력계통 고장시 계통연계형 태양광발전시스템의 영향분석)

  • Park, Sung-Hun;Lee, Yong-Sik;Jeong, Sung-Won;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.4
    • /
    • pp.69-77
    • /
    • 2019
  • Among the main functions of the grid-connected photovoltaic (PV) system, the anti-islanding operation function is a very important problem. Recently, due to the improvement in power generation efficiency and the maintenance advantages in PV system, the use of string inverter has increased so that the possibility of islanding operation has been raised. Generally, when a power system faults, the PV inverter must be disconnected from power system within 10 cycles by the anti-islanding operation function. However, in the real-time of power system, the output power of the PV system within 10cycles is effected. In this paper, we analyzed the effect of grid-connected PV system on power quality in a short time within 10 cycles on fault case of power system using the Matlab Simulink program.

Digital Surface Model based Proper Installation Site Analysis for Soundproof Wall Integrated Phtovoltaic System (수치표면모형 기반의 방음벽일체형 태양광 시스템 설치 적지분석)

  • Youn, Junhee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.556-563
    • /
    • 2020
  • Most of a BIPVS (Building Integrated Photovoltaic System) is installed on the rooftop or wall of a building. Therefore, the main factor to consider for selecting the installation site is the shadow effects produced by the surrounding buildings. On the other hand, when the photovoltaic was installed on soundproof walls, shadow effects were produced by not only surrounding buildings but also the surrounding trees. Therefore, a different data model and algorithm with the BIPVS case are essential for proper installation sites selection of a SIPVS (Soundproof wall Integrated Photovoltaic System). This paper deals with the DSM (Digital Surface Model)-based proper installation site analysis for SIPVS. First, the solar incident and altitude angles of the installation candidate sites (solar panel) during the year were calculated. Second, the shadow effects (shadowed or unshadowed) were determined for the candidate sites at each time with the DSM. Third, the amount of solar radiation was calculated with the incident angle for the candidate sites at an unshadowed period. The proper installation site of the SIPVS could then be selected by comparing the accumulated annual solar radiation for each candidate. The proposed algorithm was implemented as a prototype (Java program). From the experiment, the order of the installation suitability was determined among the nine candidates. The proposed algorithm could be used for proper BIPVS installation site analysis aimed at the lower part of a building and calculation of the expected power production.

PSCAD/EMTDC Based Modeling of a Grid-Connected Photovoltaic Generation System (PSCAD/EMTDC를 이용한 계통연계형 태양광발전시스템의 모델링)

  • Kim, Seul-Ki;Jeon, Jin-Hong;Kim, Eung-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.204-207
    • /
    • 2004
  • The paper proposes a simulation model of grid-connected photovoltaic generation system (PV system) using on PSCAD/EMTDC, a reliable power system and apparatus transient analysis program. A equivalent circuit model of a solar cell is used for modeling solar array. A series of parameters required for array modeling are deduced from general specification data of a solar module. A PWM voltage source inverter (VSI) model is presented and current control scheme is implemented for VSI control. A maximum power point tracking (MPPT) technique is applied for controlling the PV system. Simulation case study provides V-I and V-P characteristics of solar array and PV system control performance for irradiation changes.

  • PDF