• Title/Summary/Keyword: Photovoltaic Panel

Search Result 150, Processing Time 0.021 seconds

An Experimental Study of a Water Type PV/Thermal Combined Collector Unit (액체식 PV/Thermal 복합모듈의 성능실험연구)

  • Lee, Hyun-Ju;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.105-111
    • /
    • 2007
  • Hybrid PV/Thermal systems consisting of photovoltaic module and thermal collector can produce the electricity and thermal energy. The solar radiation increases the temperature of PV modules, resulting in the decrease of their electrical efficiency. Accordingly hot air can be extracted from the space between the PV panel and roof, so the efficiency of the PV module increases. The extracted thermal energy can be used in several ways, increasing the total energy output of the system. This study describes a basic type of PV/T collector using water. In order to analyze the performance of the collector, the experiment was conducted. The result showed that the thermal efficiency was 17% average and the electrical efficiency of the PV module was about $10.2%{\sim}11.5%$, both depending on solar radiation, inlet water temperature and ambient temperature.

A Novel Control Algorithm of a Three-phase Four-wire PV Inverter with Imbalance Load Compensation Function

  • Le, Dinh-Vuong;Kim, Chang-Soon;Go, Byeong-Soo;Park, Minwon;Yu, In-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1131-1137
    • /
    • 2018
  • In this paper, the authors suggest a new control algorithm for a three-phase four-wire photovoltaic (PV) inverter with imbalance load compensation function using conventional proportional-integral (PI) controllers. The maximum power of PV panel is calculated by the MPPT control loop. The reference varying signals of current controllers are transformed to two different rotating frames where they become constant signals. Then simple PI controllers are applied to achieve zero steady-state error of the controllers. The proposed control algorithm are modeled and simulated with imbalance load configuration to verify its performance. The simulation results show that the maximum PV power is transferred to the grid and the imbalance power is compensated successfully by the proposed control algorithm. The inverter has a fast response (~4 cycles) during the transient period. The proposed control algorithm can be effectively utilized to the three-phase four-wire inverter with imbalance load compensation function.

Experimental determination of the resistance of a single-axis solar tracker to torsional galloping

  • Martinez-Garcia, Eva;Marigorta, Eduardo Blanco;Gayo, Jorge Parrondo;Navarro-Manso, Antonio
    • Structural Engineering and Mechanics
    • /
    • v.78 no.5
    • /
    • pp.519-528
    • /
    • 2021
  • One of the most efficient designs of solar trackers for photovoltaic panels is the single-axis tracker, which holds the panels along a torque tube that is driven by a motor at the central section. These trackers have evolved to become extremely slender structures due to mechanical optimization against static load and the need of cost reduction in a very competitive market. Owing to the corresponding decrease in mechanical resistance, some of these trackers have suffered aeroelastic instability even at moderate wind speeds, leading to catastrophic failures. In the present work, an analytical and experimental approach has been developed to study that phenomenon. The analytical study has led to identify the dimensionless parameters that govern the motion of the panel-tracker structure. Also, systematic wind tunnel experiments have been carried out on a 3D aeroelastic scale model. The tests have been successful in reproducing the aeroelastic phenomena arising in real-scale cases and have allowed the identification and a close characterization of the phenomenon. The main results have been the determination of the critical velocity for torsional galloping as a function of tilt angle and a calculation methodology for the optimal sizing of solar tracker shafts.

Thermally reused solar energy harvesting using current mirror cells

  • Mostafa Noohi;Ali Mirvakili;Hadi Safdarkhani;Sayed Alireza Sadrossadat
    • ETRI Journal
    • /
    • v.45 no.3
    • /
    • pp.519-533
    • /
    • 2023
  • This paper implements a simultaneous solar and thermal energy harvesting system, as a hybrid energy harvesting (HEH) system, to convert ambient light into electrical energy through photovoltaic (PV) cells and heat absorbed in the body of PV cells. Indeed, a solar panel equipped with serially connected thermoelectric generators not only converts the incoming light into electricity but also takes advantage of heat emanating from the light. In a conventional HEH system, the diode block is used to provide the path for the input source with the highest value. In this scheme, at each time, only one source can be handled to generate its output, while other sources are blocked. To handle this challenge of combining resources in HEH systems, this paper proposes a method for collecting all incoming energies and conveying its summation to the load via the current mirror cells in an approach similar to the maximum power point tracking. This technique is implemented using off-the-shelf components. The measurement results show that the proposed method is a realistic approach for supplying electrical energy to wireless sensor nodes and low-power electronics.

Balcony window style photo-voltaic(PV) system design by considering resident's residential time rate - Focus on the design of apartment building balcony window PV system and it's performance - (거주자 주택 점유율을 고려한 공동주택 발코니 PV시스템 디자인 - 공동주택의 발코니 PV시스템 디자인과 성능검증 중심으로 -)

  • Chin, Kyung-Il
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.5
    • /
    • pp.101-110
    • /
    • 2009
  • In case of general residential house, photovoltaic can be installed at roof, wall, and any other places. But, in case of apartment building, there has not enough roof space to install photovoltaic panels to supply enough electricity. Actually, apartment building roof and facade wall (exclude the balcony window space) is not enough space to produce and supply the electricity to residents by installing PV panel. Generally, the space of facade balcony with windows in facade wall at apartment building occupied about $70{\sim}80%$, in all facade space. So, if we could use the balcony and windows space in facade as PV to generating electricity, there could contribute the energy saying. But, PV cell is opacify. So if it installed at front window area in apartment building, residents may have displeasure for that opacity character. But the other hand, residents are not always in house especially in day time that is exactly good time for generating electricity by PV. If we can use PV at the facade balcony with window without collusion of resident's displeasure, there have good attraction to using sustainable energy. Hence, this study suggests the design of facade balcony window style PV by considering resident's living pattern in apartment building. The methods of this study are as follows. At first, this study surveyed to the residents about residential time in their home and asked user demand by Delphi survey. At second, this study designed balcony open style PV system which oriented to the user demand. At third, this study tests designed result performance by computer simulation that compared design result with old design. As a result, For the purpose of satisfying the resident demand, there designed sliding window style which slide the several door systems to the one side. That would be make balcony absolute open scenery to the residents. Hence, the designed system performance results were as follows. When we compare the small apartment and large apartment, smaller one has good performance than larger one. Because resident's residential time characteristic. And that has more good electronic performance than vertical style that is similar to roof style.

Preliminary Experiment of the Change of Insolation under Solar Panel Mimic Shading Net (영농형 태양광 하부의 일사량 변화 분석을 위한 모의 차광 관측 실험)

  • Yoon, Changyong;Choi, Seonwoong;An, Kyu-Nam;Ryu, Jae-Hyun;Jeong, Hoejeong;Cho, Jaeil
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.4
    • /
    • pp.358-365
    • /
    • 2019
  • An agrivoltaic systems (AVS) is mixed systems associating photovoltaic panels (PVPs) and crop cultivation at the same time on the given land area. It is receiving attention to improve rural economy. However, it is likely that, the crop yield should be decreased due to the reduced absorption of solar radiation by leaves. Thus, before popularizing the AVS, it is necessary to comprehend the degree of shading by PVPs in AVS. In this study, the change of radiation condition under AVS mimic shading net was investigated. The minimum and maximum of difference of photosynthetically active radiation (PAR) between under and outside shading net were 3.03 mol/㎡/day on a cloudy day and 17.08 mol/㎡/day on a sunny day. This difference decreased when the ratio of diffuse irradiance to global irradiance increased. Such a shading effect resulted in the increase of rice height and decrease of rice tillering.

Effect of nanosilica and TEOS in hydrophilic coating solution on the surface characteristics of solar cell glass panel (나노실리카와 TEOS가 함유된 친수성 코팅액의 태양광 유리팬널에 미치는 표면 특성 연구)

  • Lee, Soo;Kim, Seung Hye;Hwang, Heon
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.152-162
    • /
    • 2017
  • A hydrophilic coating solution was prepared by adding a silane coupling agent and a nano-inorganic oxide in aqueous surfactant solution to increase the efficiency of photovoltaic power generation due to the introduction of antifogging and antifouling properties on the glass surface of the solar cell module. Addition of $Ludox^{(R)}$, a nano-inorganic oxide, to 1% hydrophilic coating solution showed improved hydrophilicity and excellent antifogging effect regardless of $Ludox^{(R)}$ concentration. However, the antifouling effect on the glass surface was showed only when Ludox was added more than 10%. In the case of addition of 0.7% of hydrolyzed TEOS at pH 4, the antifogging effect was maintained as a result of the steam test as well as the antifouling effect even after the coated glass surface was rubbed 100 times with a wet Kimwipe. In addition, from the surface roughness ($R_q$) calculated using AFM data, the higher surface roughness with irregular surface shape was obtained with the higher concentration of TEOS. The addition of 0.7% of TEOS showed relatively high surface roughness and well organized surface condition which can help to improve transmittance of light. In conclusion, $Ludox^{(R)}$ is not required only for the antifogging property. However, at least 10% of Ludox should be added to show antifouling effect and 0.7% of TEOS should be added for good durability.

Performance Analysis of the $TiO_2$ Dye-Sensitized Solar Cell according to Seasonal Changes (계절적 변화에 따른 $TiO_2$ 염료감응형 태양전지의 발전 성능 분석)

  • Moon, Byeong Eun;Choi, Eun Gyu;Kim, Jong Goo;Ryou, Young Sun;Yoon, Yong Cheol;Kim, Hyeon Tae
    • Journal of Bio-Environment Control
    • /
    • v.23 no.3
    • /
    • pp.221-228
    • /
    • 2014
  • In this study, we evaluated the efficiency of the dye-sensitized solar cell, through an analysis of the amount of energy and solar radiation according to the season. Solar array was installed next to a greenhouse in Gyeongsang National University (Latitude : N $35^{\circ}$ 9' 9.20", Longitude : E $128^{\circ}$ 5' 44.90", Altitude : 52 m), over a period of four months between August 2012 and February 2013, and solar radiation and generated electrical energy was measured and compared. The values was the greatest in October, showing that the vertical solar radiation on panel area was about 1,013.03MJ and the amount of generated power was about 4.87 kWh. The lowest values were obtained in November, showing that the vertical solar radiation on the panel area was about 755.25MJ and the amount of generated power was about 3.34 kWh. The average efficiency values were 3.12% in August, 2.60% in October, 2.39% in November, and 2.23% in February, respectively. Results of the study would be used as basic data when applying dye-sensitized solar cells to greenhouses in the future.

The Effect of Thickness on Flexible, Electrical and Optical properties of Ti- ZnO films on Flexible Glass by Atomic Layer Deposition

  • Lee, U-Jae;Yun, Eun-Yeong;Gwon, Se-Hun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.196.1-196.1
    • /
    • 2016
  • TCO(Transparent Conducting Oxide) on flat glass is used in thin-film photovoltaic cell, flat-panel display. Nowadays, Corning(R) Willow Glass(R), known as flexible substrate, has attracted much attention due to its many advantages such as reliable roll-to-roll glass processing, high-quality flexible electronic devices, high temperature process. Also, it can be an alternative to flexible polymer substrates which have their poor stability and degradation of electrical and optical qualities. For application on willow glass, the flexibility, electrical, optical properties can be greatly influenced by the TCO thin film thickness due to the inherent characterization of thin film in nanoscale. It can be expected that while thick TCO layer causes poor transparency, its sheet resistance become low. Also, rarely reports were focusing on the influence of flexible properties by varying TCO thickness on flexible glass. Therefore, it is very important to optimize TCO thickness on flexible Willow glass. In this study, Ti-ZnO thin films, with different thickness varied from 0 nm to 50 nm, were deposited on the flexible willow glass by atomic layer deposition (ALD). The flexible, electrical and optical properties were investigated, respectively. Also, these properties of Ti-doped ZnO thin films were compared with un-doped ZnO thin film. Based on the results, when Ti-ZnO thin films thickness increased, resistivity decreased and then saturated; transmittance decreased. The Figure of Merit (FoM) and flexibility was the highest when Ti-ZnO thickness was 40nm. The flexible, electrical and optical properties of Ti-ZnO thin films were better than ZnO thin film at the same thickness.

  • PDF

Wind load analysis for designing a tracking solar generator (추적식 태양광 발전기 설계를 위한 풍하중 해석)

  • Kim, Young-Eun;Jeong, Kyu-Won;Lee, Jae-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.672-680
    • /
    • 2017
  • A solar photovoltaic system is composed of a module mounting structure, supporting trunk, and a control unit that supplies generated electrical power to an external power grid or a load. The efficiency of the system depends on the incident solar light, so the mounting structure is installed to face the sun. However, because the sun always moves, systems that track the sun have better efficiency than fixed systems. The structure experiences wind pressure, snow load, seismic load, and structure weight. The wind pressure has the most serious effect on the structure. The pressure was obtained using finite element method for various gaps between modules and angles between the panel and the ground. The wind pressure is lowest when the gap is zero, and it increases with the inclination angle. Based on the results, a mounting structure module was designed.