• Title/Summary/Keyword: Photovoltaic Panel

Search Result 150, Processing Time 0.024 seconds

An Improved MPPT Converter with Current Compensation Method for Small Scaled PV-Applications (소규모 태양광 발전시스템을 위한 전류보상기법을 갖는 향상된 MPP 추적 컨버터)

  • 이동윤;노형주;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.143-150
    • /
    • 2003
  • An improved MPPT converter with current compensation method for small-scaled PV-applications is presented in this paper. The proposed method implements maximum power point tracking (MPPT) by variable reference current which is continuously changed during one sampling period. Therefore, the Power transferred to the load is increased above 9% by the proposed MPPT converter with current compensation method. As a result, the utilization efficiency of Photovoltaic (PV)-panel can be increased. In addition, as it doesn't use digital signal processor (DSP), this MPPT method has the merits of both a cost efficiency and a simple control circuit design. Therefore, it is considered that the proposed MPPT method is proper to low power, low cost PV-applications. The concept and control principles of the proposed Un moth()d are explained in detail and its validity of the proposed method is verified through several simulated results.

Characteristic Comparison of MAZO and MIZO Thin Films with Mg and ZnO Variation (Mg와 ZnO 함량변화에 따른 MAZO, MIZO 박막의 특성비교)

  • Jang, Jun Sung;Kim, In Young;Jeong, Chae Hwan;Moon, Jong Ha;Kim, Jin Hyeok
    • Current Photovoltaic Research
    • /
    • v.3 no.3
    • /
    • pp.101-105
    • /
    • 2015
  • ZnO is gathering great interest for large square optoelectrical devices of flat panel display (FHD) and solar cell as a transparent conductive oxide (TCO). Herewith, Mg and IIIA (Al, In) co-doped ZnO films were prepared on SLG substrate using RF magnetron sputtering system. The effect of variation of atomic weight % of Mg and ZnO have been investigated. The atomic weight % Al and In are of 3% and kept constant throughout. The numbers of samples were prepared according to their different contents, which are $M_{3%}AZO_{94%}$, $M_{4%}AZO_{93%}-(MAZO)$ and $M_{3%}IZO_{94%}$, $M_{4%}IZO_{93%}-(MIZO)$ respectively. A RF power of 225 W and working pressure of 6 m Torr was used for the deposition at $300^{\circ}C$. All of the two thin film show good uniformity in field emission scanning electron microscopy image. $M_{3%}AZO_{94%}$ thin film shows overall better performance among the all. The film shows the best lowest resistivity, carrier concentration, mobility and Sheet resistance and is found to be are of $8.16{\times}10^{-4}{\Omega}cm$, $4.372{\times}10^{20}/cm^3$, $17.5cm^2/vs$ and $8.9{\Omega}/sq$ respectively. Also $M_{3%}AZO_{94%}$ thin film shows the relatively high optical band gap energy of 3.7 eV with high transmittance more than 80% in visible region required for the better solar cell performance.

A Study on Development of Power Analysing Device for PV Module (태양전지 모듈의 발전량 분석 장치 개발에 관한 연구)

  • Moon, Chae-Joo;Kwak, Seung-Hun;Jang, Yeong-Hak;Kim, Tae-Gon;Kim, Eui-Sun;Kim, Tae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1~10 of M), (11~20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is-2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by $1^{\circ}C$, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by-0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced.

Using Numerical Maps to Select Solar Panel Installation Sites no Expressway Slopes (수치지도를 이용한 고속국도 주변 태양광 패널 설치 대상지 선정)

  • Jung, Jaehoon;Kim, Byungil
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.5
    • /
    • pp.71-77
    • /
    • 2016
  • Solar energy is a viable source to replace fossil fuels. However, challenges associated with site selection for solar panel installation inhibit the uptake of solar energy systems. Expressway slopes offer a potentially attractive alternative for solar panel installation for the following reasons: expressway slopes are vacant public sites, they are abundant (about 4,193km in South Korea), and they are linear in nature. Traditoinally when selecting sites for solar systems conventional surveying methods are employed. Unfortunately, these methods can be dangerous, time consuming, and labor intensive. To overcome these limitations of conventional site selection methodologies, we propose an automated approach using numerical maps. First, contour and expressway polylines are extracted separately from numeric maps. The extracted contour lines are then converted into a digital terrain model; this is used to calculate aspect and slope information. Next, the extracted expressway lines are projected onto a binary image and refined to recover the disconnections, and then applied to create a buffer zone to narrow the search space. Finally, all data sets are overlaid to identify candidate sites for solar panel systems and are visually verified through comparisons with aerial photos.

Optimal Operation Schedule of Semi-Fixed PV System and Its Effect on PV Power Generation Efficiency (반고정식 PV 시스템의 운영 스케줄 도출 및 그에 따른 발전 효율 변화 고찰)

  • Kwak, In-Kyu;Mun, Sun-Hye;Huh, Jung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.37 no.6
    • /
    • pp.69-77
    • /
    • 2017
  • The amount of solar irradiation obtained by a photovoltaic (PV) solar panel is the major factor determining the power generated by a PV system, and the array tilt angle is critical for maximizing panel radiation acquisition. There are three types of PV systems based on the manner of setting the array tilt angle: fixed, semi-fixed, and tracking systems. A fixed system cannot respond to seasonal solar altitude angle changes, and therefore cannot absorb the maximum available solar radiation. The tracking system continually adjusts the tilt angle to absorb the maximum available radiation, but requires additional cost for equipment, installation, operation, and maintenance. The semi-fixed system is only adjusted periodically (usually seasonally) to obtain more energy than a fixed system at an overall cost that is less than a tracking system. To maximize semi-fixed system efficiency, determining the optimal tilt angle adjustment schedule are required. In this research, we conducted a simulation to derive an optimal operation schedule for a semi-fixed system in Seoul, Korea (latitude $37.5^{\circ}$). We implemented a solar radiation acquisition model and PV genereation model on MATLAB. The optimal operation schedule was derived by changing the number of tilt angle adjustments throughout a year using a Dynamic Algorithm. The results show that adjusting the tilt angle 4 times a year was the most appropriate. and then, generation amount of PV system increased 2.80% compared with the fixed system. This corresponds to 99% compared to daily adjustment model. This increase would be quite valid as the PV system installation area increased.

Estimation of Optimal Angle for PV Panels Considering Building's Shadow in Daejeon (대전지역 건물음영을 고려한 PV 최적각도 산정)

  • Lee, Jung-Tae;Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol;Kim, Chang Ki;Kim, Jin-Young;Kim, Bo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.43-52
    • /
    • 2020
  • By blocking irradiance, shadows cast by high-rise buildings in urban areas can reduce the power generation efficiency of PV panels installed on low-rise buildings. As the conventionally installed PV panel is not suitable for the urban environment, which is unfavorable for power generating, a more radical solution is required. This study aims to help solve this problem by estimating the optimal PV panel angle. Using the proposed method, the optimal PV angle was calculated by considering shadows that could be cast by nearby buildings throughout the year, and the correlation between solar shading and elevation angle was discovered based on the calculated data.

A Study on the MPPT Algorithm for Buoy (브이용 태양광 최대 전력 추적 알고리즘에 관한 연구)

  • Jo, Kwan-Jun;Jung, Sung-Young;Bae, Soo-Young;Lee, Ji-Young;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.4
    • /
    • pp.588-594
    • /
    • 2009
  • The maximum power point operation point(MPPOP) of photovoltaic(PV) power generation systems changes with varying atmospheric conditions such as temperature, solar radiation. For achieving a high efficiency in PV system, it is very important for PV system to track the MPPOP correctly according to operation condition. Although the MPPT(maximum power point tracking) algorithm which applied P&O(Perturbation & Observation) or IncCnd(Incremental Conductance) algorithm tracks the MPPOP efficiently, its efficiency drops noticeably in case that the incidence angle of PV panel on buoy changes rapidly. To solve this problem, this paper proposes maximum power point searching and tracking algorithm(MPPST). The proposed algorithm set the specific area and measures the PV voltage at the same interval. The proposed algorithm have been obtained high efficiency than P&O algorithm through ocean experiment.

Development of Solar Tracking using a Photovoltaic Sensor (광센서를 이용한 태양위치 추적장치 개발)

  • Chang, Hyun-jin;Jin, Taeseok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.1023-1025
    • /
    • 2012
  • Solar energy is rapidly gaining notoriety as an important means of expanding renewable energy resources. As such, it is vital that those in engineering fields understand the technologies associated with this area. My project will include the design and construction of a microcontroller-based solar panel tracking system. Solar tracking allows more energy to be produced because the solar array is able to remain aligned to the sun. This system builds upon topics learned in this course. Performance and usefulness of a solar tracking device that was designed and produced in this study was confirmed through experiments.

  • PDF

Design and Analysis of State-of-the-Art Technologies for Development of Floating Photovoltaic System (수상태양광 발전시스템 설계 및 요소기술 분석)

  • Jin, Taeseok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.4
    • /
    • pp.227-233
    • /
    • 2014
  • Information presented in this study is intended to inform candidates as they prepare to design and structure the floatovoltaics solar power system. A developed floatovoltaics solar power generation results from the combination of PV plant technology and PV floating technology. This floating-based PV system is a new concept for PV development. The PV floating technology opens new opportunities to give value to unused areas so far while preserving valuable land for more adapted activities. Therefore the land-use conflicts are avoided and the environmental impact is minimized. Therefore the technology offers an interesting opportunity to regions facing on drought during summer time without any negative impact to the eco-system. This study describe the basic components of a floatovoltaics solar power system. A typical system consist of floating system and solar modules, a control device, rechargeable batteries, a load or device and the associated electrical connections. The floating system is specifically designed to keep all metallic components above water leaving only 100% recyclable, closed cell foam filled HDPE plastic floats in contact with the water. As the first case that can maximize the power generation efficiency of PV internationally, it is expected that this study will be utilized as a primary guide for future development of floating type PV system.

A Study on the Eco-Tecnique of EcoCenter - Focused on the Building Material and Solar System - (에코센터의 생태건축기술에 관한 연구 - 건축재료와 태양에너지활용시스템을 중심으로 -)

  • Choi, Young-Ho;Shim, Woo-Gab
    • KIEAE Journal
    • /
    • v.4 no.2
    • /
    • pp.65-72
    • /
    • 2004
  • Ecological architecture enables people to recycle and reuse architectural resources within the category of ecosystem and also to minimize the effect on environment in a whole process, including architectural planning, usage and exhaustion to use sustainable energies. Rammed earth wall construction method utilized in EcoCenter located in Crystalwaters ecological village in Austrailia is a good example, which maximizes its advantages and also covers its limits to use soil and wood as structural resources. In a case of wood, they used non-treated timber to minimize environmental load and utilized used materials in openings. In the roofs, aluminum coated steel which is plated with zinc collects rain effectively even though it is not regenerable. Nontoxic finishes and insulation in floor and ceiling with used papers are able to minimize its environmental load. Solar energy system applied in EcoCenter enables them to market extra energy with electricity companies as well as support needs of its own buildings to utilize photovoltaic panel system with PV panels. Passive solar system is planned effectively in heating and cooling to apply regenerative walls in a use of rammed earth wall construction and natural ventilation systems through openings.