• Title/Summary/Keyword: Photoplethysmography(PPG)

Search Result 103, Processing Time 0.028 seconds

A Study on the Composition of the Presentation Remote Control Analysis a Tension of Presenter (발표자의 긴장정도를 분석하는 원격제어 발표도구 제작에 관한 연구)

  • Kim, Hyeonsik;Han, Kyuhwan;Yoon, Seokbeom;Chang, Eunyoung
    • Journal of Practical Engineering Education
    • /
    • v.6 no.2
    • /
    • pp.135-139
    • /
    • 2014
  • In this study, the new model of presentation remote controller in which has improved the conventional function and deteceted the level of human's tension on a real time basis is suggested and tested. Existing presentation remote controller was just used turning the pages. But new model controls presentation and check tension level on real time using the smart phone's bluetooth interface. The proposed system is comprised with the PPG (Photo-Plethysmo-Graphy) sensor, Bluetooth and Wi-Fi modules. The configured system is to process (within 150 ms) the pulse signals of the presenter and stored the data. As a result, it can check and make up for the week presentation part and used as sources for improving self-confidence. This is the result obtained from the process of capstone design irregular course for 20 weeks of a graduate-to-be in four-year college.

Analysis of the Optimal Location of Wearable Biosensor Arrays for Individual Combat System Considering Both Monitoring Accuracy and Operational Robustness (모니터링 정확도와 운용 강건성을 고려한 개인전투체계용 착용형 생체센서 어레이의 최적 위치 분석)

  • Ha, Seulki;Park, Sangheon;Lim, Hyeoncheol;Baek, Seung Ho;Kim, Do-Kyoung;Yoon, Sang-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.22 no.2
    • /
    • pp.287-297
    • /
    • 2019
  • Monitoring for the physiological state of a solider is essential to the realization of individual combat system. Despite all efforts over the last decades, there is no report to point out the optimal location of the wearable biosensors considering both monitoring accuracy and operational robustness. In response, we quantitatively measure body temperature and heartrate from 34 body parts using 2 kinds of biosensor arrays, each of which consists of a thermocouple(TC) sensor and either a photoplethysmography(PPG) sensor or an electrocardiography(ECG) sensor. The optimal location is determined by scoring each body part in terms of signal intensity, convenience in use, placement durability, and activity impedance. The measurement leads to finding the optimal location of wearable biosensor arrays. Thumb and chest are identified as best body parts for TC/PPG sensors and TC/ECG sensors, respectively. The findings will contribute to the successful development of individual combat system.

Age-related Changes of the Finger Photoplethysmogram in Frequency Domain Analysis (연령증가에 따른 지첨용적맥파의 주파수 영역에서의 변화)

  • Nam, Tong-Hyun;Park, Young-Bae;Park, Young-Jae;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.12 no.1
    • /
    • pp.42-62
    • /
    • 2008
  • Objectives: It is well known that some parameters of the photoplethysmogram (PPG) acquired by time domain contour analysis can be used as markers of vascular aging. But the previous studies that have been performed for frequency domain analysis of the PPG to date have provided only restrictive and fragmentary information. The aim of the present investigation was to determine whether the harmonics extracted from the PPG using a fast Fourier transformation could be used as an index of vascular aging. Methods: The PPG was measured in 600 recruited subjects for 30 second durations, To grasp the gross age-related change of the PPG waveform, we grouped subjects according to gender and age and averaged the PPG signal of one pulse cycle. To calculate the conventional indices of vascular aging, we selected the 5-6 cycles of pulse that the baseline was relatively stable and then acquired the coordinates of the inflection points. For the frequency domain analysis we performed a power spectral analysis on the PPG signals for 30 seconds using a fast Fourier transformation and dissociated the harmonic components from the PPG signals. Results: A final number of 390 subjects (174 males and 216 females) were included in the statistical analysis. The normalized power of the harmonics decreased with age and on a logarithmic scale reduction of the normalized power in the third (r=-0.492, P<0.0001), fourth (r=-0.621, P<0.0001) and fifth harmonic (r=-0.487, P<0.0001) was prominent. From a multiple linear regression analysis, Stiffness index, reflection index and corrected up-stroke time influenced the normalized power of the harmonics on a logarithmic scale. Conclusions: The normalized harmonic power decreased with age in healthy subjects and may be less error prone due to the essential attributes of frequency domain analysis. Therefore, we expect that the normalized harmonic power density can be useful as a vascular aging marker.

  • PDF

A New Method for Unconstrained Pulse Arrival Time (PAT) Measurement on a Chair

  • Kim Ko-Keun;Chee Young-Joon;Lim Yong-Gyu;Choi Jin-Wook;Park Kwang-Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.3
    • /
    • pp.83-88
    • /
    • 2006
  • A new method of measuring pulse arrival time (PAT), which is usually used for the estimation of systolic blood pressure, in an unconstrained manner using a chair, is proposed. The capacitive-coupled ECG (CC-ECG) measurement system and the air cushion with balancing tubes system were used for unconstrained PAT measurement. Firstly, the correlation between the standard PAT (S-PAT) from the photoplethysmography (PPG) and the PAT measured in an unconstrained manner (U-PAT) was evaluated. It was observed that U-PAT, which is the time delay from the R-peak of ECG to the steepest decent point of air cushion pressure wave, is significantly correlated with the S-PAT. Secondly, systolic blood pressure (SBP) measured by the radial tonometer is compared to the U-PAT. The ten-beat averaged U-PAT removed respiration effects and demonstrated a high intra-subject correlation with SBP in all participants. Finally, the tonometry SBP was estimated from these U-PAT values for one participant intermittently during half a day.

Implemetation and Estimation of the Wearable PTT Monitoring System Using Wireless Sensor Network (무선 센서네트워크를 이용한 착용형 PTT 측정시스템의 구현 및 평가)

  • Kim, Jin-Ho;Kang, Hag-Seong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.137-140
    • /
    • 2010
  • 본 연구에서는 일상생활에서 보다 편리하게 건강모니터링을 수행하기 위해 신체에 착용 가능한 심전도 및 맥파 계측 시스템을 구현하고자 하였다. 이를 위하여 배터리로 구동 가능한 초소형의 심전도 및 맥파 측정 시스템을 구현하였으며, 계측된 생체신호의 무선전송을 위해 초저전력 무선 센서네트워크 기술을 적용한 무선 생체신호 전송시스템을 구현하였다. 무선으로 전송된 심전도 및 맥파 신호는 잡음 제거 및 심박동을 검출하기 위하여 전처리과정과 적응 가변형 문턱치를 적용하였으며, 검출된 심박동으로부터 동맥순환계의 긴장도 및 유순도의 변화를 반영하는 맥파전달시간(pulse transit time, PTT)을 계산하였다. 구현된 무선 맥파전달시간 계측시스템과 기존 상용시스템의 비교 평가를 수행함으로써 구현된 시스템의 유용성을 평가하고자 하였으며, 혈압 및 맥파전달시간의 동시계측을 통해 자세 변화에 따른 혈압의 변화 및 맥파전달시간의 변화양상을 관찰함으로써 혈압과 맥파전달시간의 관계를 추정하고자 하였다.

  • PDF

Implementation of PTT Change Monitoring System According to Exercise Intensity (PTT기반 운동 강도 모니터링 시스템 구현)

  • Lee, Ji-Su;Kim, Dong-Chan;Lee, Gyeong-Tack;Kim, Gyeong-Seop;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.1
    • /
    • pp.49-54
    • /
    • 2020
  • Cardiovascular disease is the leading cause of death worldwide and is caused by a variety of causes. The highest risk factor for cardiovascular disease is high blood pressure, which has no obvious symptoms, but if left untreated, it causes several complications. In order to treat hypertension, medication and regular exercise are required. In people with high blood pressure, excessive physical activity can put a great strain on the heart and lead to cardiovascular disease. Therefore, there is a need for an exercise intensity monitoring system through PTT measurement that can perform exercise at an appropriate intensity. In this study, we implemented a PTT change monitoring system according to exercise intensity by calculating PTT through ECG and PPG measurement. The implemented system differentiates the R-peak of the ECG and P-peak of the PPG, and calculates the PTT using the time difference between R-peak and P-peak. A running experiment was conducted to monitoring PTT change according to exercise intensity. As a result of the experiment, low intensity PTT is 0.313s, moderate is 0.220s, high is 0.188s, it was confirmed that the PTT decreased as the exercise increase increased.

Development of Pulse Measurement Method for Health Monitoring of Dairy Cows (젖소 건강 모니터링을 위한 맥박 측정 방법 개발)

  • Jun, Hak-Bong;Kim, Han-Joon;Kim, Jin-Oh
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.12
    • /
    • pp.27-37
    • /
    • 2013
  • Today, livestock industry grows faster and bigger. The number of livestock numbers per farm also grows rapidly. The bigger farms need more sophisticated control of livestock to prevent from all possible diseases, especially contagious diseases. In Korea, diseases cause serious economic loss of 2 trillion won every year, which is about 20% of the total production output. Researches on the wireless bio-signal monitoring technology for livestock are of great importance in the world. In this paper, as a way to predict the possible diseases, we propose a measurement method of the pulse of dairy cows for the continuous health monitoring. It is possible to measure a pulse from central artery and the left chest-wall of the cow. The pulse from central artery is measured by the sensor attached at the tail winding. The pulse at the left chest-wall can also be measured with our newly designed harness.

Heart Response Effect by 1/f Fluctuation Sounds for Emotional Labor on Employee (1/f 수준 별 음악 자극이 감정 노동 종사자의 심장 반응에 미치는 효과)

  • Jeon, Byung-Mu;Whang, Min-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.18 no.3
    • /
    • pp.63-70
    • /
    • 2015
  • This study identified heart response of participants while listening to sounds which have 1/f fluctuations with exponent ${\alpha}$ gradient. The participants were engaged in emotional stress work. Prior studies related to 1/f fluctuation sound have reported that sound source can alleviate psychological and physiological state of users. Subjects of this study were exposed to sound with three levels of ${\alpha}$ gradient. Heart response of subjects were measured with Photoplethysmography(PPG) sensor simultaneously. The dependent variables of this study were beat per minute(BPM), very low frequency percent of pulse rate variability (VLF percent), the standard deviation of all normal RR intervals (SDNN), and high frequency power(HF power). Subject showed arousal response when exposed to sound with exponent ${\alpha}$ gradient of 3 whereas the sound with exponent ${\alpha}$ gradient of 1 and 2 resulted in relax effect. The characteristic of 1/f fluctuation sounds can be applied to alleviate stress for employers under emotional labor.

The effect of rewards on developing right user attitudes of elementary school children (보상이 초등학생의 게임 사용 습관에 미치는 영향)

  • Kim, Young-Joo;Kim, Hea Jin;Lee, Jung-Nyun;Whang, Mincheol
    • Journal of Korea Game Society
    • /
    • v.17 no.2
    • /
    • pp.27-34
    • /
    • 2017
  • The study is to drive right users' attitude of internet and smart phones by providing the rewards. It consisted of 4 different types of no compensation, praise card, achievement sticker and cash and its effect on user's behavior was statistically tested. 24 children in grades four through six participated in the study. The task in this study was game of mathematical calculation. The subjective satisfaction about the reward and heart response during the game task were measured. As the results, inactivation of sympathetic and parasympathetic was observed in the case of no compensation while activation in the case of praise card. Therefore, the praise card was observed in greater commitment and satisfaction than the other rewards. The difference between non-compensation and compensation was significant in the subjective satisfaction, but not difference between compensations.

Affective interaction to emotion expressive VR agents (가상현실 에이전트와의 감성적 상호작용 기법)

  • Choi, Ahyoung
    • Journal of the Korea Computer Graphics Society
    • /
    • v.22 no.5
    • /
    • pp.37-47
    • /
    • 2016
  • This study evaluate user feedback such as physiological response and facial expression when subjects play a social decision making game with interactive virtual agent partners. In the social decision making game, subjects will invest some of money or credit in one of projects. Their partners (virtual agents) will also invest in one of the projects. They will interact with different kinds of virtual agents which behave reciprocated or unreciprocated behavior while expressing socially affective facial expression. The total money or credit which the subject earns is contingent on partner's choice. From this study, I observed that subject's appraisal of interaction with cooperative/uncooperative (or friendly/unfriendly) virtual agents in an investment game result in increased autonomic and somatic response, and that these responses were observed by physiological signal and facial expression in real time. For assessing user feedback, Photoplethysmography (PPG) sensor, Galvanic skin response (GSR) sensor while capturing front facial image of the subject from web camera were used. After all trials, subjects asked to answer to questions associated with evaluation how much these interaction with virtual agents affect to their appraisals.