• 제목/요약/키워드: Photodiodes

검색결과 112건 처리시간 0.026초

a-Si:H Photodiode Using Alumina Thin Film Barrier

  • Hur Chang-Wu;Dimitrijev Sima
    • Journal of information and communication convergence engineering
    • /
    • 제3권4호
    • /
    • pp.179-183
    • /
    • 2005
  • A photodiode capable of obtaining a sufficient photo/ dark current ratio at both forward bias state and reverse bias state is proposed. The photodiode includes a glass substrate, an aluminum film formed as a lower electrode over the glass substrate, an alumina film formed as an insulator barrier over the aluminum film, a hydrogenated amorphous silicon film formed as a photo conduction layer over a portion of the alumina film, and a transparent conduction film formed as an upper electrode over the hydro-generated amorphous silicon film. A good quality alumina $(Al_2O_3)$ film is formed by oxidation of aluminum film using electrolyte solution of succinic acid. Alumina is used as a potential barrier between amorphous silicon and aluminum. It controls dark-current restriction. In case of photodiodes made by changing the formation condition of alumina, we can obtain a stable dark current $(\~10^{-12}A)$ in alumina thickness below $1000{\AA}$. At the reverse bias state of the negative voltage in ITO (Indium Tin Oxide), the photo current has substantially constant value of $5{\times}10^{-9}$ A at light scan of 100 1x. On the other hand, the photo/dark current ratios become higher at smaller thicknesses of the alumina film. Therefore, the alumina film is used as a thin insulator barrier, which is distinct from the conventional concept of forming the insulator barrier layer near the transparent conduction film. Also, the structure with the insulator thin barrier layer formed near the lower electrode, opposed to the ITO film, solves the interface problem of the ITO film because it provides an improved photo current/dark current ratio.

CsI(T1) 방사선센서의 제작 및 분광특성 연구 (A Study on the Fabrication of CsI(T1) Radiation Sensor and its Spectroscopic Characteristics)

  • 권수일;신동호
    • 한국의학물리학회지:의학물리
    • /
    • 제13권1호
    • /
    • pp.44-50
    • /
    • 2002
  • 실험실에서 성장시킨 CsI(T1)섬광체를 이용하여 검출기를 설계 제작하고 분광 및 출력특성을 조사하여 핵분광과 진단방사선센서로서의 응용가능성을 타진해 보았다. CsI(T1)단결정은 수직 Bridgman성장장치를 이용하여 지름 11mm, 몰농도 0.001mo1%로 성장시키었다. 이 단결정을 광다이오드를 이용하여 방사선 센서로 제작한 후, $^{22}$ Na, /up 137/Cs, $^{30}$ Co 표준감마선원에 대한 에너지 분해능을 각각 측정하였으며 진단 X선 영역에 대한 출력특성도 측정하였다. $^{22}$ Na의 0.511 MeV 의 경우13.2%, $^{137}$Cs의 0.662 MeV의 경우 8.3%, 그리고 $^{60}$Co의 1.17 MeV와 1.332 MeV에 대해서는 각각 6.7%와 5.1%의 에너지 분해능을 얻었다. 또한 관전압 60kVp, 80kVp, 100kVp, 120kVp 에 대하여 5mAs부터 80mAs 까지 진단 X선영역에 대한 출력 선형성을 확인하였다.

  • PDF

고섬광에 노출된 광센서의 손상 특성 : 열확산 모델 (Characteristics of Damage on Photosensor Irradiated by Intense Illumination : Thermal Diffusion Model)

  • 권찬호;신명숙;황현석;김홍래;김성식;박민규
    • 한국군사과학기술학회지
    • /
    • 제15권2호
    • /
    • pp.201-207
    • /
    • 2012
  • Pulsed lasers at the 613 nm and 1064 nm wavelengths on nanoseconds have been utilized to characterize the damage on Si photodiode exposed to intense illumination. Morphological damages and structural changes at sites on the photodiode irradiated during microseconds of laser pulses were analyzed by FE-SEM images and XRD patterns, respectively. The removal of oxide coating, ripple, melting marks, ridges, and crater on photodiodes were definitely observed in order of increasing the pulse intensities generated above the damage threshold. Then, the degradation in photosensitivity of the Si photodiode irradiated by high power density pulses was measured as a function of laser irradiation time at the various wavelengths. The free charge carrier and thermal diffusion mechanisms could have been invoked to characterize the damage. The relative photosensitivity data calculated using the thermal diffusion model proposed in this paper have been compared with the experimental data irradiated above the damage threshold.

방사능 수치 오염 지도 작성을 위한 방사선 계측 시스템 연구 (Study of Radiation Mapping System for Water Contamination in Water System)

  • 나원경;김한수;연제원;이레나;하장호
    • 방사선산업학회지
    • /
    • 제5권2호
    • /
    • pp.185-189
    • /
    • 2011
  • As nuclear industry has been developed, a various types of radiological contamination has occurred. After 9.11 terror in U.S.A., it has been concerned that terrorists' active area has been enlarged to use nuclear or radioactive substance. Recently, the most powerful earth-quake stroke, which triggered a massive tsunami in Japan and then Fukushima nuclear power plant reactor has suffered from a serious accident in history. The Fukushima reactor accident has occurred an anxiety of radiation leaks and about 170,000 people have been evacuated from the accidental area near the nuclear power plant. For these reasons, a social chaos can be occurred if radiological contamination occurs to the supply system for the drinking water. As such, the establishment of the radiation monitoring system for the city main water system is compelling for the national security. In this study, a feasibility test of radiation monitoring system which consists of unified hybrid-type radiation detectors was experimented for multi detection system by using gamma-ray imaging. The hybrid-type radiation sensors were fabricated with CsI(Tl) scintillators and photodiodes. A preamplifier and amplifier was also fabricated and assembled with the sensor in the shielding case. For the preliminary test of detection of radiological contamination in the river, multi CsI(Tl)-PIN photodiode radiation detectors and $^{137}Cs$ gamma-ray source were used. The DAQ was done by Linux based ROOT program and NI DAQ system with Labview program. The simulated contamination was assumed to be occurred at Gapcheon river in Daejeon city. Multi CsI(Tl)-PIN photodiode radiation detectors were positioned at the Gapcheon river side. Assuming that the radiological contaminations flows in the river the $^{137}Cs$ gamma-ray source has been moved and then, the contamination region was reconstructed.

Feasibility Study for an Optical Sensing System for Hardy Kiwi (Actinidia arguta) Sugar Content Estimation

  • Lee, Sangyoon;Sarkar, Shagor;Park, Youngki;Yang, Jaekyeong;Kweon, Giyoung
    • 농업생명과학연구
    • /
    • 제53권3호
    • /
    • pp.147-157
    • /
    • 2019
  • In this study, we tried to find out the most appropriate pre-processing method and to verify the feasibility of developing a low-price sensing system for predicting the hardy kiwis sugar content based on VNIRS and subsequent spectral analysis. A total of 495 hardy kiwi samples were collected from three farms in Muju, Jeollabukdo, South Korea. The samples were scanned with a spectrophotometer in the range of 730-2300 nm with 1 nm spectral sampling interval. The measured data were arbitrarily separated into calibration and validation data for sugar content prediction. Partial least squares (PLS) regression was performed using various combinations of pre-processing methods. When the latent variable (LV) was 8 with the pre-processing combination of standard normal variate (SNV) and orthogonal signal correction (OSC), the highest R2 values of calibration and validation were 0.78 and 0.84, respectively. The possibility of predicting the sugar content of hardy kiwi was also examined at spectral sampling intervals of 6 and 10 nm in the narrower spectral range from 730 nm to 1200 nm for a low-price optical sensing system. The prediction performance had promising results with R2 values of 0.84 and 0.80 for 6 and 10 nm, respectively. Future studies will aim to develop a low-price optical sensing system with a combination of optical components such as photodiodes, light-emitting diodes (LEDs) and/or lamps, and to locate a more reliable prediction model by including meteorological data, soil data, and different varieties of hardy kiwi plants.

휴대용 수면 패턴 모니터링을 위한 복합 fNIRS-EEG 시스템 개발 (Development of a Hybrid fNIRS-EEG System for a Portable Sleep Pattern Monitoring Device)

  • 김경한;우성우;하성훈;박금룡;사커 엠디 샤힌;박배정;김창세
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권6호
    • /
    • pp.392-403
    • /
    • 2023
  • This study presents a new hybrid fNIRS-EEG system to meet the demand for a lightweight and low-cost sleep pattern monitoring device. For multiple-channel configuration, a six-channel electroencephalogram (EEG) and a functional near-infrared spectroscopy (fNIRS) system with eight photodiodes (PD) and four dual-wavelength LEDs are designed. To enhance the convenience of signal measurement, the device is miniaturized into a patch-like form, enabling simultaneous measurement on the forehead. Due to its fully integrated functionality, the developed system is advantageous for performing sleep stage classification with high-temporal and spatial resolution data. This can be realized by utilizing a two-dimensional (2D) brain activation map based on the concentration changes in oxyhemoglobin and deoxyhemoglobin during sleep stage transitions. For the system verification, the phantom model with known optical properties was tested at first, and then the sleep experiment for a human subject was conducted. The experimental results show that the developed system qualifies as a portable hybrid fNIRS-EEG sleep pattern monitoring device.

12개 다이오드 레이저를 활용하는 레이저 복사출력계 교정시스템 개발 (Development of Laser Power Meter Calibration System with 12-diode Laser Sources)

  • 이강희;유재근;배인호;박성종;이동훈
    • 한국광학회지
    • /
    • 제35권2호
    • /
    • pp.61-70
    • /
    • 2024
  • 400 nm부터 1,600 nm까지의 파장 영역에서 단일모드 광섬유에 결합된 12개의 다이오드 레이저 광원를 기반으로 하는 레이저 복사출력계 교정시스템을 소개한다. 본 시스템은 복사출력 측정위치에서 레이저 출력요동을 최소화하였고 모든 광원에 대해 비슷한 빔 크기를 갖는다. 또한 감응도의 비균일도 및 비선형성을 최소화하기 위해 적분구 기준기를 사용하였다. 이 교정시스템의 최소 측정불확도는 대부분의 레이저 파장에서 1.1% (k=2)로 추정된다.

OPTICAL MULTI-CHANNEL INTENSITY INTERFEROMETRY - OR: HOW TO RESOLVE O-STARS IN THE MAGELLANIC CLOUDS

  • Trippe, Sascha;Kim, Jae-Young;Lee, Bangwon;Choi, Changsu;Oh, Junghwan;Lee, Taeseok;Yoon, Sung-Chul;Im, Myungshin;Park, Yong-Sun
    • 천문학회지
    • /
    • 제47권6호
    • /
    • pp.235-253
    • /
    • 2014
  • Intensity interferometry, based on the Hanbury Brown-Twiss effect, is a simple and inexpensive method for optical interferometry at microarcsecond angular resolutions; its use in astronomy was abandoned in the 1970s because of low sensitivity. Motivated by recent technical developments, we argue that the sensitivity of large modern intensity interferometers can be improved by factors up to approximately 25 000, corresponding to 11 photometric magnitudes, compared to the pioneering Narrabri Stellar Interferometer. This is made possible by (i) using avalanche photodiodes (APD) as light detectors, (ii) distributing the light received from the source over multiple independent spectral channels, and (iii) use of arrays composed of multiple large light collectors. Our approach permits the construction of large (with baselines ranging from few kilometers to intercontinental distances) optical interferometers at the cost of (very) long-baseline radio interferometers. Realistic intensity interferometer designs are able to achieve limiting R-band magnitudes as good as $m_R{\approx}14$, sufficient for spatially resolved observations of main-sequence O-type stars in the Magellanic Clouds. Multi-channel intensity interferometers can address a wide variety of science cases: (i) linear radii, effective temperatures, and luminosities of stars, via direct measurements of stellar angular sizes; (ii) mass-radius relationships of compact stellar remnants, via direct measurements of the angular sizes of white dwarfs; (iii) stellar rotation, via observations of rotation flattening and surface gravity darkening; (iv) stellar convection and the interaction of stellar photospheres and magnetic fields, via observations of dark and bright starspots; (v) the structure and evolution of multiple stars, via mapping of the companion stars and of accretion flows in interacting binaries; (vi) direct measurements of interstellar distances, derived from angular diameters of stars or via the interferometric Baade-Wesselink method; (vii) the physics of gas accretion onto supermassive black holes, via resolved observations of the central engines of luminous active galactic nuclei; and (viii) calibration of amplitude interferometers by providing a sample of calibrator stars.

방사선치료 시뮬레이터의 비접속형관전압계 제작과 성능분석 (Fabrication of the Noninvasive Tube Voltage Meter of Radiotherapy Simulator and Its Performance Analysis)

  • 김종언;윤천실;김성현;박창희;차병열
    • 한국의학물리학회지:의학물리
    • /
    • 제17권4호
    • /
    • pp.201-206
    • /
    • 2006
  • 본 연구에서는 방사선치료 시뮬레이터 장치에서 조사되는 X-선 빔의 강도로부터 관전압 측정과 관전압의 파형을 관찰 할 수 있는 비접속형 관전압계를 제작하였고, 그 성능을 분석하여 임상에 사용 가능성을 검토하였다. 관전압계의 검출부는 X-선 조사면(field)의 Y축 방향으로 ${\pm}1.4cm$ 지점에 두 개의 광다이오드를 배치하고 그 위에 두께가 다른 알루미늄여과체를 각각 놓아 구성하였다. 설정 피크 관전압에 대한 여과체의 두께 비에 비례하는 상대적인 출력 실효 전압비($r_{eff}$)를 측정하고, NERO 6000M 기준 관전압계로 설정 피크 관전압에 대한 실효 피크 관전압($kV_{p,eff}$)을 측정하여 자연 대수치를 구하였다. 관전압계의 교정을 위해 상대적인 출력 실효 전압 비($r_{eff}$)와 실효 피크 관전압 대수치($InkV_{p,eff}$)를 선형 회귀 분석하였다. 얻어진 선형 상관계수(r)는 0.996 이었다. 따라서 제작된 비접속형 관전압계는 충분한 정확도를 가지고 있어 임상에서의 사용이 가능하다고 생각된다.

  • PDF

검출기 정렬 오차가 TOF-PET 검출기의 성능에 미치는 영향성 평가 (Effect of Detector-Misalignment on TOF-PET Detector Performance)

  • 양진규;강지훈
    • 한국방사선학회논문지
    • /
    • 제13권6호
    • /
    • pp.841-846
    • /
    • 2019
  • 본 연구에서는 섬광결정과 광센서의 정렬 오차가 TOF-PET 검출기 성능에 미치는 영향성을 정량적으로 평가하였다. 한 쌍 TOF-PET 검출기는 3 mm × 3 mm × 20 mm 체적을 갖는 LYSO 섬광체와 3.07 mm × 3.07 mm 크기의 GAPD 광센서로 구성된다. 아날로그 출력신호는 증폭 및 균일도 보정이 수행되었고, 오실로스코프 기반 데이터 획득 장치에서 신호처리되었다. 각 검출기 정렬 오차는 0.0 mm, 0.5 mm, 1.0 mm, 1.5 mm 를 각각 적용하여 총 16단계의 정렬 오차를 발생시켰다. 검출기 정렬 오차가 증가함에 따라 광절정위치는 약 400 mV에서 약 250 mV로 감소하였다. 또한, 에너지분해능은 11.6%에서 16.2%로, 시간분해능은 477 ps에서 632 ps로 저하되었다. 이 결과는 검출기 정렬 오차가 TOF-PET 검출기 성능저하에 큰 영향성을 내포함을 시사한다.