• Title/Summary/Keyword: Photo analysis

Search Result 727, Processing Time 0.028 seconds

An Experiment of Flame Chemiluminescence Measurement for Real Time Air/Fuel Ratio Control (실시간 공연비 제어를 위한 화염 자발광 측정 실험)

  • Lee, Jin Ki;Kwon, Min Jun;Lee, Chang Yeop;Kim, Se-Won;Shin, Myung Chul
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.29-30
    • /
    • 2012
  • The objectives of this study are to examine the variation of flame chemiluminescence on flame condition and to evaluate the possibility to apply the optical sensor for air/fuel ratio control. Flame chemiluminescence is one of the most important factor to judge the real time flame condition like a air/fuel ratio. In this paper, it is experimentally found that a strong relationship between the air/fuel ratio and optical element output (i.e., photo diode) should be existed. This is verified through the flame spectral analysis for various PD output signal.

  • PDF

Photostabilization and Cure Kinetics of UV-Curable Optical Resins Containing Photostabilizers

  • Cho, Jung-Dae;Kim, Sung-Hwa;Chang, In-Cheol;Kim, Kwon-Seok;Hong, Jin-Who
    • Macromolecular Research
    • /
    • v.15 no.6
    • /
    • pp.560-564
    • /
    • 2007
  • The photostabilization and cure kinetics of UV-curable, optical resins containing various formulations of photostabilizers were investigated to determine the system with the highest cure conversion and durability. Photo-DSC analysis revealed that increasing the concentration of a UV absorber (UVA) decreased both the crosslink density and the cure rate due to competition for the incident photons between the photoinitiator and the UVA, whereas including a hindered amine light stabilizer (HALS) hardly affected either the cure conversion or the cure rate due to its very low absorption of 365 nm. This result was confirmed by FTIR-ATR spectroscopy and UV-visible spectroscopy analyses. QUV ageing experiments showed that the cure conversion and durability were the highest for the UVA/HALS formulation at a ratio of 1 : 2, which is due to their synergistic action.

Synthesis and Characterization of CdSe/graphene Nanocomposites and their Catalytic Reusability Studies under Visible Light Radiation

  • Ali, Asghar;Oh, Won-Chun
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.6
    • /
    • pp.502-507
    • /
    • 2015
  • We examined the photo catalytic activity and catalytic recyclability of CdSe/graphene nanocomposites fabricated via modified hydrothermal technique. The prepared composites were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) with energy dispersive X-ray (EDX), transmission electron microscopy (TEM), Raman spectroscopic analysis, and X-ray photoelectron spectroscopy (XPS). The photocatalytic behavior was investigated through decomposition of RBB as a standard dye under visible light radiation. Our results indicate that there is significant potential for graphene based semiconductor hybrids materials to be used as photocatalysts under visible light irradiation for the degradation of organic dyes from industry effluents.

Design of Photo-Detector for Particle Sizer Using Laser Diffraction (레이저 회절성에 의한 입자 크기의 계측을 위한 센서 설계)

  • Nam, Boo-Hee;Kang, Sung-Gui;Yu, Tae-U;Bang, Byeong-Ryeol;Jee, Gyu-ln
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.437-440
    • /
    • 1992
  • We design a multi-element photo-detector to measure the size of particles using the diffracted light energy distribution. The light energy that is scattered by particles in the collimated laser beam is collected by the Fourier transform lens and directed to the multi-semicircular concentric annular detecters. The scattered profile measured by the photodetector is sampled by a 32 channel analog-to-digital converter. A nonnegative least squares analysis translates the light energy distribution into the corresponding unique particle size distribution.

  • PDF

Performance Analysis of the BIPV/T system by the performance Test- Part2. Thermal Performance (실험을 통한 BIPV/T 시스템 성능분석-2.시스템 열성능)

  • Jo, Hye-Jin;Lee, Hyeon-Ju
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.255-259
    • /
    • 2012
  • BIPV/T (Building Intergrated PhotoVoltaic/Thermal) is combined system produces electricity and thermal energy. The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. The test system is installed to top floor of the experimental house in the KEPCO Research Institute. The experimental performance is executed from 13th February to 13th March, 2012. The expected system's thermal performance is 1.9kWh under the horizontal solar radiation is $600W/m^2$ and the air flow in the system is $20CMH/m^2$.

  • PDF

Performance Analysis of the BIPV/T system by the performance Test- Part1. PV efficiency (실험을 통한 BIPV/T 시스템 성능분석-1. PV 발전효율)

  • Lee, Hyeon-Ju;Jo, Hye-Jin
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.445-450
    • /
    • 2012
  • BIPV/T (Building Intergrated PhotoVoltaic/Thermal) is combined system produces electricity and thermal energy. The heat from PV modules should be removed for better electrical performance, and can be converted into useful thermal energy. The efficiency of the PV system's performance will raise by the system removes heat from the PV. The test system is installed to top floor of the experimental house in the KEPCO Research Institute. The planned experiment is following. (1) Supplying heat energy to top floor. (2) Supplying heat and cool energy to thermal storage in the bottom of the top floor. (3) Supplying heat energy to EHP for improved performance. The experimental performance is executed from 13th February to 13th March, 2012. The solar generation of electricity is 4.04kWh under the horizontal solar radiation is $1000W/m^2$ and the air temperature is $25^{\circ}C$.

  • PDF

Characteristics of Sulfide Treated GaAs MISFETs with Photo-CVD Grown $P_3$$N_5$ Gate Insulators (유화처리와 광CVD법 질화인막을 이용한 GaAs MISFET 특성)

  • 최기환;조규성;정윤하
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.9
    • /
    • pp.72-77
    • /
    • 1994
  • GaAs MISFETs, with photo-CVD grown P$_{3}$N$_{5}$ gate insulator and sulfide treatment, have been fabricated and showed the instability of drain current reduced less than 22 percent for the period of 1.0s~1.0${\times}10^{4}s$. The effective electron mobility and extrinsic transconductance of the device are about 1300cm$^{2}$/V.sec and 1.33mS at room temperature. The C-V characteristics of GaAs MIS Diode and AES analysis are also discussed with respect to effect of sulfide treatment conditions.

  • PDF

Hydrogen Generation from Water Using CdS-ZnS Photocatalysts (CdS-ZnS 광촉매를 이용한 물의 광전기 분해에 의한 수소 발생)

  • Heo, Gwi Suk
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.1 no.1
    • /
    • pp.9-14
    • /
    • 1989
  • Mixed photocatalyst containing cadmium sulfide and zinc sulfide was prepared on silica gel powder and Nafion film. Photo-irradiation of aqueous mixture containing the photocatalysis generated hydrogen by water cleavage reaction. Use of sodium sulfide as sacrificial reagent help the photo-reaction. Evolution of the hydrogen was measured by gas chromatographic analysis. Composition of the catalyst was determined by atomic absorption spectrophotometer. 0.2 mL of of hydrogen was generated per hour. The maximun catalytic activity was obtained after 8-12 hours later. Hydrogen generation efficiency by the two different catalytic system was compared and showed that the Nafion-based catalyst is more efficient than the silicagel-based catalyst for the photoreaction.

  • PDF

Development of Wireless Instrument for Measuring Cattle's Somatic Information for Stockbreeding Automatization(II) - Development of Single-Channel Wireless Instrument for Measuring Sphygmus - (축산자동화를 위한 가축의 생체정보 무선 계측장치 개발(II) - 단일채널 무선 맥박 계측장치 개발 -)

  • Lee, S.K.;Min, Y.B.;Kim, T.K.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.4
    • /
    • pp.404-409
    • /
    • 1992
  • It is important to measure the somatic informations for stockbreeding automatization. This study was carried out for the development of wireless measurement system of sphygmus in living animals. In meauring sphygmus counting with the single-channel telemety system, a LED-photo transistor sensor showed more sensitivity to the change of blood pressure than a piezo-electric sensor based pressure sensor. The LED-photo transistor sensor resulted ${\pm}1.29%$ of measurement error of sphygmus counting. In the process of transmitting and receiving the blood pressure signal for counting sphygmus, noises were mixed with, and the noises made the counting almost impossible. Auto-correlation analysis technique was applied to the signal data to extract the sphygmus information, and the technique was proved to be very effective.

  • PDF

Development of a Automated Noncontact Weighing System for Pigs (돼지의 자동 비접촉 체중계측 시스템 개발)

  • 임영일
    • Journal of Animal Environmental Science
    • /
    • v.6 no.1
    • /
    • pp.23-30
    • /
    • 2000
  • A automated noncontact weight system for pigs consisted of a CCD-type video camera and 10 photo sensors connected to a computer. In the experiment 20 pigs(Large Yorkshire $\times$ Landrace breed) weighing from 95kg to 115kg were used. Pig's original image data was transformed to a binary image an image excluding head and tail portion from the whole binary image and the area of pig was calculated. Then pig's volume was calculated by multiplying the area by the body hight measured with photo sensors. The correlation equation between the above volume(x) and pig's weight was y=0.0007 x -9.2152($R^2$=0.9965) Performance of a automated noncontact weighing system for pigs was tested with this equation. The results showed $\pm$0.65kg average error and 1.63kg maximum error. It was concluded that performance of a automated noncontact weighing system is excellent.

  • PDF