• 제목/요약/키워드: Phasor Measurement

검색결과 74건 처리시간 0.027초

측정데이터를 이용한 실시간 정적 부하모델링 (On-line Static Load Modeling using Measurement Data)

  • 박상현;정동현;강상균;이병준;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.282-284
    • /
    • 2006
  • In this paper, Static load models are developed using measurement based approach which is fundamental for on-line load modeling. The measurement data can be acquired from PMU(phasor measurement units). On the assumption that we have on-line measurement data, a scheme which is for Static load model capable to apply SCADA/EMS is developed. The Least Squares criterion is used for minimizing between measured and simulated data. In this manner, On-line Static load modeling algorithm can be developed. In this paper, a scheme that simple Static load model is applied for On-line load modeling is studied.

  • PDF

다채널 단일톤 위상 측정칩 개발 (Development of a Sensor Chip for Phasor Measurement of Multichannel Single Tone Signals)

  • 김병일;홍근표;황진용;장태규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.497-500
    • /
    • 2005
  • This paper presents a design of a hybrid sensor chip which integrates an A/D converter module and a phase measurement module for measuring power line phase. Recursive sliding DFT based phase measurement module is designed using time shared multiplier which can reduce the size of SoC implementation. A/D converter is based on the sigma delta modulation in order to minimize the implementation space of the analog part and designed to obtain 8-bit resolution. Computer simulations and FPGA implementation are performed to verify hybrid sensor chip design. The hybrid sensor chip for 4-channel power line phase measurement is fabricated by using 0.35 micrometer CMOS process.

  • PDF

광역 방어시스템의 통신 트래픽 모사와 분석 (Simulation and Analysis of the Network Traffic of a Power Infrastructure Defense System)

  • 백윤기;이건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.179-180
    • /
    • 2006
  • The real time monitoring of the power systems covering wide area are essential for the stable operation and control of the power system. Synchronized phasor measurement is a key for the precise monitoring and control of the power systems. In this paper, to suggest an appropriate network topology of Power Infrastructure Defense System(PIDS) and to estimate the maximum network bandwidth with using the network analyzer, we simulate a PIDS and analyze the network traffic.

  • PDF

시계열 데이터를 이용한 새로운 온라인 미소신호안정도 평가 방법과 적용 (A New Method for Assessing On-line Small-signal Stability and its Application)

  • 김동준;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.387-389
    • /
    • 2006
  • This paper describes new on-line small signal stability assessment and its application using the time series simulated phasor measurement data. Using FFT technique and optimization method, the suggested method can effectively identify all of mode frequencies involved in measured data and calculate the damping ratio with accuracy.

  • PDF

순환 DFT에 기초한 페이저 연산 장치의 ASIC 구현 (An ASIC implementation of Phasor Measurement Unit based on Sliding-DFT)

  • 김종윤;김석훈;장태규;김재화
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(4)
    • /
    • pp.143-146
    • /
    • 2001
  • 본 논문에서는 다 채널 페이저 연산 장치를 전용하드웨어로 구현하기 위한 설계 구조에 대하여 제시하였으며, 이를 연산량이 많은 곱셈기를 시분할에 의해 공유하는 구조를 제시하였다. 또한 페이저 측정을 위한 Sliding-DFT 알고리즘을 순환 구현할 경우의 근사구현 오차에 관한 정량적인 연구를 수행하였다. 이러한 오차 영향의 해석을 기반으로 하여 곱셈기 공유 구조를 적용한 페이저 연산 장치를 설계하고, 설계한 하드웨어의 내부동작을 보여주는 시뮬레이션을 통해 설계의 정확성을 확인하였다

  • PDF

웨이브렛 분석 기반 다이나믹 페이저 추정 및 성능 비교평가 (Wavelet-Based Dynamic Phasor Estimation and Performance Evaluation)

  • 김도인;전태윤;윤성화;이결;박진배;신용준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.171-172
    • /
    • 2015
  • PMU (Phasor Measurement Unit)는 전력시스템의 노드에서 실시간으로 시간 동기화된 페이저 정보를 측정하여 전력계통 모니터링을 가능하게 하는 장치이다. 이 때, PMU가 모니터링 장치로서 활용되기 위해서는 고신뢰도의 페이저 정보 측정이 요구된다. 기본적인 페이저 추정기법은 푸리에 변환을 이용하여 정현파 신호의 기본주파수 성분을 분석하는 것으로 본 논문에서는 푸리에 변환 기반 페이저 추정기법과 웨이브렛 기반 페이저 추정기법의 성능을 분석하여 웨이브렛 기반 페이저 추정기법의 타당성을 검토하고자 하였다. 페이저 추정기법의 평가에는 IEEE 표준에 따른 TVE (Total Vector Error) 개념을 사용하며 정현파 신호의 진폭변화와 위상변화 및 잡음발생 환경의 진폭변화에 대하여 페이저 추정 기법들의 성능평가로 신뢰성을 확인하였다.

  • PDF

진동 감시용 위치 결정 센서의 위상오차에 대한 실험적 고찰과 비교 평가 (The Experimental Study and Comparison on Usage of Vibration Monitoring Sensors for Positioning of Balancing on Rotating Machinery)

  • 오승태;유무상;봉석근
    • 한국소음진동공학회논문집
    • /
    • 제25권2호
    • /
    • pp.101-107
    • /
    • 2015
  • Field balancing is required in any kind of phase information for the determination location balancing mass toward a rotor unbalance mass. Phase or phase angle is a measurement of the relationship of how one vibration signal which relates to another vibration signal and is commonly used to calculate the placement of balance weight. In this paper, A right guideline shows the photo optical speed sensor as the external KeyPhasor is a very useful when diagnosing machinery vibration problems on considering a phase lag comparing to the laser optical speed sensor. Some experimental results generate the interesting phase errors when appling to a wrong conditions. So, Usage of photo optical speed sensor which is used primarily to measure the shaft rotating speed serves as a reference for measuring vibration phase information has effect on the placement of phase angle how it was misunderstood. This paper will help a right method to search for the position of balancing weight and serves as baseline for further measurements using low cost and much easier user convenience. It is concluded that the propose baseline is likely to be applicable to apply to the practical field balancing weight.

고속 적응자동재폐로를 위한 사고거리추정 및 사고판별에 관한 개선된 양단자 수치해석 알고리즘 (An Improved Two-Terminal Numerical Algorithm of Fault Location Estimation and Arcing Fault Detection for Adaptive AutoReclosure)

  • 이찬주;김현홍;박종배;신중린;조란 라도예빅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권11호
    • /
    • pp.525-532
    • /
    • 2005
  • This paper presents a new two-terminal numerical algorithm for fault location estimation and for faults recognition using the synchronized phaser in time-domain. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the assumed PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. Also the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. In this paper the algorithm is given and estimated using DFT(discrete Fourier Transform) and the LES(Least Error Squares Method). The algorithm uses a very short data window and enables fast fault detection and classification for real-time transmission line protection. To test the validity of the proposed algorithm, the Electro-Magnetic Transient Program(EMTP/ATP) is used.

Protection Strategies Against False Data Injection Attacks with Uncertain Information on Electric Power Grids

  • Bae, Junhyung;Lee, Seonghun;Kim, Young-Woo;Kim, Jong-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권1호
    • /
    • pp.19-28
    • /
    • 2017
  • False data injection attacks have recently been introduced as one of important issues related to cyber-attacks on electric power grids. These attacks aim to compromise the readings of multiple power meters in order to mislead the operation and control centers. Recent studies have shown that if a malicious attacker has complete knowledge of the power grid topology and branch admittances, s/he can adjust the false data injection attack such that the attack remains undetected and successfully passes the bad data detection tests that are used in power system state estimation. In this paper, we investigate that a practical false data injection attack is essentially a cyber-attack with uncertain information due to the attackers lack of knowledge with respect to the power grid parameters because the attacker has limited physical access to electric facilities and limited resources to compromise meters. We mathematically formulated a method of identifying the most vulnerable locations to false data injection attack. Furthermore, we suggest minimum topology changes or phasor measurement units (PMUs) installation in the given power grids for mitigating such attacks and indicate a new security metrics that can compare different power grid topologies. The proposed metrics for performance is verified in standard IEEE 30-bus system. We show that the robustness of grids can be improved dramatically with minimum topology changes and low cost.

스마트 그리드를 위한 소규모 전력에너지 관리 시스템 개발에 관한 연구 (A Study on Development of Small Scale Electric Power Management System for Smart Grid)

  • 이창수;오해석
    • 한국산학기술학회논문지
    • /
    • 제13권6호
    • /
    • pp.2826-2832
    • /
    • 2012
  • 스마트 그리드는 기존에 발전소에서 전력을 일방적으로 공급하는 단방향 전력망에 정보기술을 접목하여 전력 공급자와 소비자가 양방향으로 실시간 정보를 교환함으로써 에너지 효율을 최적화하는 방식이다. 스마트그리드의 전력 관리 시스템은 동적인 가격제도와 함께 소비자들에게 전력사용에 대한 정보를 제공함으로써, 수요의 반응을 유도하고, 전력 계통의 투자와 운영에 있어 효율을 향상시키는데 있다. 하지만, 최근 전력 관리 시스템들은 실시간 가격 등 가격 제도에 주로 초점을 두고 있다. 본 논문에서는 가격 제도에 초점을 둔 기존 전력관리 시스템을 개선하여 전력 사용의 효율성에 초점을 둔 전력에너지 운영 관리 시스템을 제안한다. 전력 데이터는 배전반에 설치된 PMU(Phasor Measurement Units)를 통해 수집되며 데이터 마이닝 기법을 통한 분석 방법으로 효율성 높이고자 한다. 또한 전력 부족 및 과잉 공급 시 PMU와 양방향 통신을 통해 제어할 수 있도록 구현 및 실험하여 전력에너지 관리시스템의 효율성을 입증하였다.