• 제목/요약/키워드: Phase-separate cycle

검색결과 10건 처리시간 0.027초

2단압축 상분리 사이클을 적용한 이산화탄소 시스템의 성능향상에 관한 해석적 연구 (Simulation Study on the Performance Improvement of a $CO_2$ System Applying a Two-stage Phase-separate Cycle)

  • 류창기;이호성;김용찬;조흥현;조성욱
    • 설비공학논문집
    • /
    • 제18권8호
    • /
    • pp.641-648
    • /
    • 2006
  • In this study, a two-stage phase-separate cycle was investigated analytically to improve the performance of the $CO_2$ system in the cooling mode. The simulation results were verified with the measured data. The predictions using the simulation model were consistent with the measured data within ${\pm}20%$ deviations. The performance of the modified $CO_2$ system with the two-stage phase-separated cycle was analyzed with the variations of outdoor temperature and EEV opening. The cooling COP decreased with the increase of compressor frequency. The highest COP was 2.7 at compressor frequencies of 30 Hz and 30 Hz for the first and second compressors, respectively. In addition, the cooling COP increased by 9.3% with an application of optimum control of the first and second-stage EEV openings.

DO THE OBSERVED RELATIONS OF THE GLOBAL SEISMIC PARAMETERS DEPEND ON THE MAGNETIC ACTIVITY LEVEL?

  • Kim, Ki-Beom;Chang, Heon-Young
    • 천문학회지
    • /
    • 제54권4호
    • /
    • pp.121-128
    • /
    • 2021
  • It has been known that the global asteroseismic parameters as well as the stellar acoustic mode parameters vary with stellar magnetic activity. Some solar-like stars whose variations are thought to be induced by magnetic activity, however, show mode frequencies changing with different magnitude and phase unlike what is expected for the Sun. Therefore, it is of great importance to find out whether expected relations are consistently manifested regardless of the phase of the stellar magnetic cycle, in the sense that observations are apt to cover a part of a complete cycle of stellar magnetic activity unless observations span several decades. Here, we explore whether the observed relations of the global seismic parameters hold good regardless of the phase of the stellar magnetic cycle, even if observations only cover a part of the stellar magnetic cycle. For this purpose, by analyzing photometric Sun-as-a-star data from 1996 to 2019 covering solar cycles 23 and 24, we compare correlations of the global asteroseismic parameters and magnetic proxies for four separate intervals of the solar cycle: solar minima ±2 years, solar minima +4 years, solar maxima ±2 years, and solar maxima +4 years. We have found that the photometric magnetic activity proxy, Sph, is an effective proxy for the solar magnetic activity regardless of the phase of the solar cycle. The amplitude of the mode envelope correlates negatively with the solar magnetic activity regardless of the phase of the solar cycle. However, relations between the central frequency of the envelope and the envelope width are vulnerable to the phase of the stellar magnetic cycle.

회전부품의 탈락으로 발생한 복합화력 증기터빈의 이상 진동 (Abnormal vibration of Combined cycle due to separate rotating parts)

  • 구재량;조형래;황재현;김두영;윤완노;김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.356-360
    • /
    • 2003
  • At rotating machinery, Many factors had caused vibration. especially one of the major factor is mass unbalance. A sort of mass unbalance are followings; Static, Coupling, Single and Dynamic. In this paper, We had investigated abnormal vibration due to mass unbalance that changed phase whenever starting of steam Turbine at Combined Cycle.

  • PDF

왜몰개, Aphyocypris chinensis의 생식주기 (Reproductive Cycle of the Venus Fish, Aphycypris chinensis)

  • 이성규;최신석;염동혁
    • 생태와환경
    • /
    • 제33권4호통권92호
    • /
    • pp.395-404
    • /
    • 2000
  • 1997년 3월부터 1998년 3월까지 충청남도 부여군 세도면 모세올 지역의 농수로에서 채집한 왜몰개, Aphyocypris chinensis를 대상으로 생식생태를 조사하기 위하여 연간 생식소숙도지수(GSI), 간숙도지수(HSI), 난경조성과 생식소 발달과정 및 다른 번식특성들을 조사하였다. GSI 변화, 생식소의 발달과정 및 난경조성에 대한 분석결과, 1${\sim}$2월은 정체기, 3${\sim}$5월은 2차 성장기 및 성숙기, 6월에서 7월 사이는 완숙 및 산란기, 8${\sim}$9월은 퇴화 및 휴지기, 10${\sim}$12월은 1차 성장기로 나타낼 수 있었다. HSI는 연간 2개의 피크를 나타냈으며 GSI의 변화와는 역상관 관계를 보였다. 조사지점에서의 왜몰개 암컷의 포란수는 체중과 1차 함수적으로 증가하였으며 (r$^{2}$ =0.91, n = 347), 성비는 1.4 : 1 (암컷 : 수컷) 이었다. 생식가능한 최소 체장(fork length) 범위는 암컷에서는 38 mm, 수컷에서는 33mm로 조사되었다.

  • PDF

팽창기를 적용한 이산화탄소 냉방시스템의 성능특성에 관한 해석적 연구 (Simulation Study on the Performance Characteristics of a $CO_2$ Cooling System with an Expander)

  • 조홍현;백창현;류창기;김용찬
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.630-639
    • /
    • 2007
  • A $CO_2$ cycle shows large throttling loss during the expansion process. The application of an expander into the $CO_2$ cycle can reduce the throttling loss and then improve system performance. In this study, the performance of a transcritical $CO_2$ cycle with an expander was analytically investigated in order to improve the cooling performance of the system. The expander was applied to the single-stage and two-stage compression cycles. The performance was analyzed with the variations of compressor frequency, outdoor temperature, and expander efficiency. The single-stage and two-stage compression cycles with the expander showed COP improvement of 25% and 32%, respectively, over the single-stage cycle with an EEV.

Life cycle impact assessment of the environmental infrastructures in operation phase: Case of an industrial waste incineration plant

  • Kim, Hyeong-Woo;Kim, Kyeong-Ho;Park, Hung-Suck
    • Environmental Engineering Research
    • /
    • 제22권3호
    • /
    • pp.266-276
    • /
    • 2017
  • A life cycle impact assessment was applied in an industrial waste incineration plant to evaluate the direct and indirect environmental impacts based on toxicity and non-toxicity categories. The detailed life cycle inventory of material and energy inputs and emission outputs was compiled based on the realistic data collected from a local industrial waste incineration plant, and the Korean life cycle inventory and ecoinvent database. The functional unit was the treatment of 1 tonne of industrial waste by incineration and the system boundary included the incineration plant and landfilling of ash. The result on the variation of the impact by the unit processes showed that the direct impact was decreased by 79.3, 71.6, and 90.1% for the processes in a semi dry reactor, bag filter, and wet scrubber, respectively. Considering the final impact produced from stack, the toxicity categories comprised 91.7% of the total impact. Among the toxicity impact categories, the impact in the eco-toxicity category was most significant. A separate estimation of the impact due to direct and indirect emissions showed that the direct impact was 97.7% of the total impact. The steam recovered from the waste heat of the incineration plant resulted in a negative environmental burden.

황-요오드 열화학 수소 제조 공정에서 분젠 반응과 상 분리 비고 (The Comparison of Bunsen Reaction With Phase Separation in Sulfur-lodine Thermochemical Hydrogen Production Process)

  • 이광진;안승혁;김영호;박주식;배기광
    • 한국수소및신에너지학회논문집
    • /
    • 제19권2호
    • /
    • pp.111-117
    • /
    • 2008
  • A Bunsen reaction section is a primary stage of Sulfur-iodine thermochemical hydrogen production cycle. This section is important, because it decides the efficiency of next stages. In order to produce hydrogen very efficiently, the characteristics of Bunsen reaction were investigated via two experimental methods. The one is a phase separation of $H_2SO_4-HI-H_2O-I_2$ mixture system, and the other is a direct Bunsen reaction. The characteristics of each method were investigated and compared. As the result of this study, the amount of HI and $I_2$ in $H_2SO_4$ phase via Bunsen reaction was more decreased than that via $H_2SO_4-HI-H_2O-I_2$ mixture system with increasing $I_2$ concentration. However, the amount of $H_2SO_4$ in $HI_x$ phase via Bunsen reaction was remarkably increased with increasing $I_2$ concentration, while that via $H_2SO_4-HI-H_2O-I_2$ mixture system was decreased. On the other hand, the range of initial composition which is able to separate into two liquid phases without $I_2$ solidification was almost alike.

CPS를 위한 모델 기반 자율 컴퓨팅 프레임워크 (Model-based Autonomic Computing Framework for Cyber-Physical Systems)

  • 강성주;전인걸;박정민;김원태
    • 대한임베디드공학회논문지
    • /
    • 제7권5호
    • /
    • pp.267-275
    • /
    • 2012
  • In this paper, we present the model-based autonomic computing framework for a cyber-physical system which provides a self-management and a self-adaptation characteristics. A development process using this framework consists of two phases: a design phase in which a developer models faults, normal status constrains, and goals of the CPS, and an operational phase in which an autonomic computing engine operates monitor-analysis-plan-execute(MAPE) cycle for managed resources of the CPS. We design a hierachical architecture for autonomic computing engines and adopt the Model Reference Adaptive Control(MRAC) as a basic feedback loop model to separate goals and resource management. According to the GroundVehicle example, we demonstrate the effectiveness of the framework.

다중 메모리 뱅크 구조를 위한 고속의 자료 할당 기법 (Rapid Data Allocation Technique for Multiple Memory Bank Architectures)

  • 조정훈;백윤홍;최준식
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2003년도 가을 학술발표논문집 Vol.30 No.2 (1)
    • /
    • pp.196-198
    • /
    • 2003
  • Virtually every digital signal processors(DSPs) support on-chip multi- memory banks that allow the processor to access multiple words of data from memory in a single instruction cycle. Also, all existing fixed-point DSPs have irregular architecture of heterogeneous register which contains multiple register files that are distributed and dedicated to different sets of instructions. Although there have been several studies conducted to efficiently assign data to multi-memory banks, most of them assumed processors with relatively simple, homogeneous general-purpose resisters. Therefore, several vendor-provided compilers fer DSPs were unable to efficiently assign data to multiple data memory banks. thereby often failing to generate highly optimized code fer their machines. This paper presents an algorithm that helps the compiler to efficiently assign data to multi- memory banks. Our algorithm differs from previous work in that it assigns variables to memory banks in separate, decoupled code generation phases, instead of a single, tightly-coupled phase. The experimental results have revealed that our decoupled algorithm greatly simplifies our code generation process; thus our compiler runs extremely fast, yet generates target code that is comparable In quality to the code generated by a coupled approach

  • PDF

공기조화, 냉동 분야의 최근 연구 동향 - 1998년 1999년 학회지 논문에 대한 종합적 고찰 - (Recent Progress in Air Conditioning and Refrigeration Research - A Review of papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 1998 and 1999 -)

  • 이재헌;김광우;김병주;이재효;김우승;조형희;김민수
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1098-1125
    • /
    • 2000
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 1998 and 1999 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. 1) A review of the recent studies on fluid flow, turbomachinery and pipe-network shows that many experimental investigations are conducted in applications of impingement jets. Researches on turbulent flows, pipe flows, pipe-networks are focused on analyses of practical systems and prediction of system performance. The results of noise reduction in the turbomachinery are also reported. 2) A review of the recent studies on heat transfer analysis and heat exchanger shows that there were many papers on the channel flow with the application to the design of heat exchanger in the heat transfer analysis. Various experimental and numerical papers on heat exchanger were also published, however, there were few papers available for the analysis of whole system including heat exchanger. 3) A review of the recent studies on heat pump system have focused on the multi-type system and the heat pump cycle to utilize treated sewage as the heat source. The defrosting and the frosting behaviors in the fin-tube heat exchanger is experimentally examined by several authors. Several papers on the ice storage cooling system are presented to show the dynamic simulation program and optimal operation conditions. The study on the micro heat pipes for the cooling of high power electronic components is carried out to examine the characteristics of heat and mass transfer processed. In addition to these, new type of separate thermosyphon is studied experimentally. 4) The recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. New systems operating with natural refrigerants are drawing lots of attention. In addition to these, evaporation and condensation heat transfer characteristics of traditional and new refrigerants are investigated for plain tubes and also for microfin tubes. Capillary tubes and orifice are main topics of research as expansion devices and studies on thermophysical properties of new refrigerants and refrigerant/oil mixtures are widely carried out. 5) A review of the recent studies on absorption cooling system shows that numerous experimental and analytical studies on the improvement of absorber performance have been presented. Dynamic analysis of compressor have been performed to understand its vibration characteristics. However research works on tow-phase flow and heat transfer, which could be encountered in the refrigeration system and various phase-change heat exchanger, were seemed to be insufficient. 6) A review of recent studies on duct system shows that the methods for circuit analysis, and flow balancing have been presented. Researches on ventilation are focused on the measurement of ventilation efficiency, and variation of ventilation efficiency with ventilation methods by numerous experimental and numerical studies. Furthermore, many studies have been conducted in real building in order to estimate indoor thermal environments. Many research works to get some information for cooling tower design have been performed but are insufficient. 7) A review on the recent studies on architectural thermal environment and building mechanical systems design shows that thermal comfort analysis is sitting environment, thermal performance analysis of Korean traditional building structures., and evaluation of building environmental load have been performed. However research works to improve the performance of mechanical system design and construction technology were seemed to be insufficient.

  • PDF