• Title/Summary/Keyword: Phase-current detection

Search Result 286, Processing Time 0.027 seconds

Design of a Built-in Current Sensor for Current Testing Method in CMOS VLSI (CMOS 회로의 전류 테스팅를 위한 내장형 전류감지기 설계)

  • 김강철;한석붕
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.11
    • /
    • pp.1434-1444
    • /
    • 1995
  • Current test has recently been known to be a promising testing method in CMOS VLSI because conventional voltage test can not make sure of the complete detection of bridging, gate-oxide shorts, stuck-open faults and etc. This paper presents a new BIC(built-in current sensor) for the internal current test in CMOS logic circuit. A single phase clock is used in the BIC to reduce the control circuitry of it and to perform a self- testing for a faulty current. The BIC is designed to detect the faulty current at the end of the clock period, so that it can test the CUT(circuit under test) with much longer critical propagation delay time and larger area than conventional BICs. The circuit is composed of 18 devices and verified by using the SPICE simulator.

  • PDF

Open Fault Diagnosis Method for Five-Phase Induction Motor Driving System (5상 유도전동기 구동 시스템을 위한 인버터의 개방고장진단 방법)

  • Baek, Seung-Koo;Shin, Hye-Ung;Kang, Seong-Yun;Park, Choon-Soo;Lee, Kyo-Beum
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.2
    • /
    • pp.304-310
    • /
    • 2016
  • This paper proposes a fault diagnosis method for an open-fault in inverter driving five-phase induction motor. The five-phase induction motor has a high output torque and small torque ripple in comparison to three-phase. The best advantage of the five-phase induction motor is fault diagnosis and tolerant control using redundancy of phases. This paper uses an inverter as a power converter for driving a five-phase induction motor. If a switch of inverter occurs to the open-fault, this problem is the influence on the output current and output torque. To solve this problem, there is need of an accurate diagnosis and fault switch distinction. Therefore, this paper propose a fault detection method of the open-fault switches for the fault diagnosis. First, analyzing the pattern for the open-circuit fault of one phase. next, analyzing the pattern for the open-circuit fault of each inverter switches. Through the pattern analysis, It defines the scope of each of the failure switch. Thereafter, By using an algorithm that proposes to perform a fault diagnosis method. The proposed algorithm is verified from the experiment with the 1.5 kW five-phase induction motor.

Development of a New Islanding Detection Method for Distributed Resources (분산 전원의 고립 운전 검출 기법의 개발)

  • Jang, Seong-Il;Kim, Gwang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.11
    • /
    • pp.506-513
    • /
    • 2001
  • The islanding detection for distributed resources (DR) becomes an important and emerging issue in power system protection since the distributed generator installations are rapidly increasing and most of the installed systems are interconnected with distribution network. In order to avoid the negative impacts from islanding operations of DR on protection, operation and management of distribution system, it is necessary to effectively detect the islanding operations of DR and rapidly disconnect it from distribution network. Generally, it is difficult to detect islanding operation by monitoring only one system parameter This paper presents a new logic based islanding detection method for distributed resources(DR) which are interconnected with distribution network. The proposed method detects the islanding operation by monitoring four system parameter: voltage variation, phase displacement, frequency variation, and the variation of total harmonic distortion(THD) of current; therefore, it effectively detects island operation of DR unit operating in parallel with the distribution network. We also verified the efficiency of the proposed algorithm using the radial distribution network of IEEE 34 bus model.

  • PDF

Fault Detection and Diagnosis Systems of Induction Machines using Real-Time Stochastic Modeling Approach (실시간 확률 모델링 기법을 이용한 유도기기의 고장검출 및 진단시스템)

  • Lee, Jin-Woo;Kim, Kwang-Soo;Cho, Hyun-Cheol;Lee, Young-Jin;Lee, Kwon-Soon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.241-248
    • /
    • 2009
  • This paper presents stochastic methodology based fault detection algorithm for induction motor systems. We measure current of healthy induction motors by means of hall sensor systems and then establish its probability distribution. We propose online probability density estimation which is effective in real-time implementation due to its simplicity and low computational burden. In addition, we accomplish theoretical analysis of the proposed estimation to demonstrate its convergence property by using statistical convergence and system stability theories. We apply our fault detection approach to three-phase induction motors and achieve real-time experiment for evaluating its reliability and practicability in industrial fields.

Fast Diagnosis Method for Submodule Failures in MMCs Based on Improved Incremental Predictive Model of Arm Current

  • Xu, Kunshan;Xie, Shaojun
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1608-1617
    • /
    • 2018
  • The rapid and correct isolation of faulty submodules (SMs) is of great importance for improving the reliability of modular multilevel converters (MMCs). Therefore, a fast diagnosis method containing fault detection and fault location determination was presented in this paper. An improved incremental predictive model of arm current was proposed to detect failures, and the multi-step prediction method was used to eliminate the negative impact of disturbances. Moreover, a control method was proposed to strengthen the fault characteristics to rapidly locate faulty arms and faulty SMs by detecting the variation rate of the SM capacitor voltage. The proposed method can rapidly and easily locate faulty SMs under different load conditions without the need for additional sensors. The experimental results have validated the effectiveness of the proposed method by using a single-phase MMC with four SMs per arm.

Drive characteristics of moving primary LSRM according to position detection angle (가동 1차측 LSRM의 위치 검출각에 따른 운전 특성)

  • Jang, Seok-Myeong;Park, Ji-Hoon;You, Dae-Joon;Cho, Han-Wook;Choi, Jang-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.99-101
    • /
    • 2005
  • This paper deals with drive characteristics of LSRM according to position detection angle. Position of LSRM detected approximation sensor. Position choose mover of LSRM and inductance. When approved current in each phase by decided position, we made sure current and voltage according to turn-on, turn-off.

  • PDF

Fault Detection of Power Systems Using Fuzzy Pattern Classification (퍼지 패턴분류를 이용한 전력개통에서의 고장검출)

  • Kim, Hee-Soo;Ko, Jae-Ho;Bang, Sung-Yun;Yim, Hwa-Yeoung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1203-1205
    • /
    • 1998
  • Fault Detection of power system must be rapid and precise over input signal without relation to any disturbance. But, it is difficult to detect current unbalance, over voltage, and underfrequency for digital relay comparison of fault perfectly. In this paper, we measure each phase current and infer type of fault using fuzzy pattern classification.

  • PDF

Rotor Fault Detection of Induction Motors Using Stator Current Signals and Wavelet Analysis

  • Hyeon Bae;Kim, Youn-Tae;Lee, Sang-Hyuk;Kim, Sungshin;Wang, Bo-Hyeun
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.539-542
    • /
    • 2003
  • A motor is the workhorse of our industry. The issues of preventive and condition-based maintenance, online monitoring, system fault detection, diagnosis, and prognosis are of increasing importance. Different internal motor faults (e.g., inter-turn short circuits, broken bearings, broken rotor bars) along with external motor faults (e.g., phase failure, mechanical overload, blocked rotor) are expected to happen sooner or later. This paper introduces the fault detection technique of induction motors based upon the stator current. The fault motors have rotor bar broken or rotor unbalance defect, respectively. The stator currents are measured by the current meters and stored by the time domain. The time domain is not suitable to represent the current signals, so the frequency domain is applied to display the signals. The Fourier Transformer is used for the conversion of the signal. After the conversion of the signals, the features of the signals have to be extracted by the signal processing methods like a wavelet analysis, a spectrum analysis, etc. The discovered features are entered to the pattern classification model such as a neural network model, a polynomial neural network, a fuzzy inference model, etc. This paper describes the fault detection results that use wavelet decomposition. The wavelet analysis is very useful method for the time and frequency domain each. Also it is powerful method to detect the features in the signals.

  • PDF

Metamaterial CRLH Structure-based Balun for Common-Mode Current Indicator

  • Kahng, Sungtek;Lee, Jinil;Kim, Koon-Tae;Kim, Hyeong-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.301-306
    • /
    • 2014
  • We proposed a new PCB-type 'common-mode current($I_c$) and differential-mode current($I_d$) detector' working for fast detection of $I_c$ and $I_d$ from the differential-mode signaling, with miniaturization effect and possibility of cheaper fabrication. In order to realize this device, we suggest a branch-line-coupler balun having a composite right- and left-handed(CRLH) one-layer microstrip phase-shifting line as compact as roughly ${\lambda}_g/14$. The presented balun obviously is different from the conventional bent-&-folded delay lines or slits on the ground for coupling the lines on the top and bottom dielectrics. As we connect the suggested balun output ports of the differential-mode signal lines via the through-port named U and coupled-port named L, $I_c$ and $I_d$ will appear at port ${\Delta}$ and port ${\Sigma}$ of the present device, in order. The validity of the design scheme is verified by the circuit-and numerical electromagnetic analyses, and the dispersion curve proving the metamaterial characteristics of the geometry. Besides, the examples of the $I_c$ and $I_d$ indicator are observed as the even and odd modes in differential-mode signal feeding. Also, the proposed device is shown to be very compact, compared with the conventional structure.

32-Channel Bioimpedance Measurement System for the Detection of Anomalies with Different Resistivity Values (저항률이 다른 내부 물체의 검출을 위한 32-채널 생체 임피던스 측정 시스템)

  • 조영구;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.503-510
    • /
    • 2001
  • In this paper. we describe a 32-channel bioimpedance measurement system It consists of 32 independent constant current sources of 50 kHz sinusoid. The amplitude of each current source can be adjusted using a 12-bit MDAC. After we applied a pattern of injection currents through 32 current injection electrodes. we measured induced boundary voltages using a variable-gain narrow-band instrumentation amplifier. a Phase-sensitive demodulator. and a 12-bit ADC. The system is interfaced to a PC for the control and data acquisition. We used the system to detect anomalies with different resistivity values in a saline Phantom with 290mm diameter The accuracy of the developed system was estimated as 2.42% and we found that anomalies larger than 8mm in diameter can be detected. We Plan to improve the accuracy by using a digital oscillator improved current sources by feedback control, Phase-sensitive A/D conversion. etc. to detect anomalies smaller than 1mm in diameter.

  • PDF