Rotor position detection of bifilar-wound hybrid stepping motors by phase current measurement (상전류 측정에 의한 복권형 하이브리드 스테핑 전동기의 회전자 위치 검출)

  • Kim, Kyu-Hui;You, Jeong-Bong;Woo, Kwang-Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.6
    • /
    • pp.619-625
    • /
    • 1997
  • In this paper, we show that the rotor position of the bifilar-wound hybrid stepping motors for the closed-loop drives is detected by the phase current measurement. We propose an instantaneous phase current equation, which is the function of electrical angle, by modeling the stepping motor including motor driving circuits. We also analyze the relationship between phase current and rotor position from the computer simulation results. We show that the information about the rotor position is obtained from the phase current amplitude and its derivatives at the instance of ${\pi}/2$ electrical angle of excitation voltage.

  • PDF

Anti-islanding Detection Method for BESS Based on 3 Phase Inverter Using Negative-Sequence Current Injection (역상분 전류 주입을 적용한 3상 인버터 기반 BESS의 단독 운전 검출 방법)

  • Sin, Eun-Suk;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1315-1322
    • /
    • 2015
  • This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with 3-phase inverter which is connected to the AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase Locked-Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage at the PCC (Point of Common Connection) due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides a secure and rapid detection under the variation of negative-sequence voltage due to the sag and swell. The feasibility of proposed method was verified by computer simulations with PSCAD/EMTDC and experimental analyses with 5kW hardware prototype for the benchmark circuit of islanding detection suggested by IEEE 1547 and UL1741. The proposed method would be applicable for the secure detection of islanding state in the grid-tied Microgrid.

Algorithm of Extended Current Synchronous Detection for Active Power Filters (능동전력필터를 위한 확장된 전류 동기 검출 알고리즘)

  • 정영국
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.111-114
    • /
    • 2000
  • Harmonics and fundamental reactive power of nonlinear loads in serious unbalanced power condition are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system, but the CSD theory is not suitable any more in case of controlled independently harmonics and reactive component. Therefore a new algorithm the extended current synchronous detection (ECSD)theory for a three phase active power filter based on decomposition of fundamental reactive distorted components is proposed in this paper. The proposed ECSD theory is simulated and tested comparison with a few power theories under asymmtrical condition in power system.

  • PDF

A VLSI Architecture for Novel Decision Feedback Differential Phase Detection with an Accumulator

  • Kim, Chang-Kon;Chong, Jong-Wha
    • ETRI Journal
    • /
    • v.24 no.2
    • /
    • pp.161-171
    • /
    • 2002
  • This paper proposes a novel decision feedback differential phase detection (DF-DPD) for M-ary DPSK. A conventional differential phase detection method for M-ary Differential Phase Shift Keying (DPSK) can simplify the receiver architecture. However, it possesses a poorer bit error rate (BER) performance than coherent detection because of the prior noisy phase sample. Multiple-symbol differential detection methods, such as maximum likelihood differential phase detection, Viterbi-DPD, and DF-DPD using L-1 previous detected symbols, have attempted to improve BER performance. As the detection length, L, increases, the BER performance of the DF-DPD improves but the complexity of the architecture increases dramatically. This paper proposes a simplified DF-DPD architecture replacing the conventional delay and additional architecture with an accumulator. The proposed architecture also improves BER performance by minimizing the current differential phase noise through the accumulation of previous differential phase noise samples. The simulation results show that the BER performance of the proposed architecture approaches that of a coherent detection with differential decoding.

  • PDF

A Modified Sapce-Vector PWM Inverter without Phase Current Sensors

  • Joo, Hyeong-Gil;Shin, Hwi-Beom;Oh, In-Hwan;Youn, Myung-Joong
    • Journal of Electrical Engineering and information Science
    • /
    • v.2 no.4
    • /
    • pp.86-91
    • /
    • 1997
  • A method of detecting the three phase currents for a voltage-fed pusle width modulated(PWM) inverter is proposed, where only one current sensor is utilized on the dc-link. The proposed method has the constant sampling time by employing he modified space-vector PWM technique which generates the rearranged switching pattern to detect a phase current from ad dc-link current. Experimental results show that eh proposed scheme provides a very good detection method of three phase currents without phase current sensors. This method is very simple and has small detection errors.

  • PDF

Switch Open Fault Detection and Tolerant Operation Method for Three Phase PWM Rectifier (3상 PWM 정류기의 스위치 개방 고장 감지 및 허용운전 방법)

  • Shin, Hee-Keun;An, Byoung-Woong;Kim, Hag-Wone;Cho, Kwan-Yuhl;Jung, Shin-Myung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.266-273
    • /
    • 2012
  • In this paper, the new open fault detection and tolerant operation method for 3 phase PWM rectifier is proposed. When open fault occurred on the inverter switches of 3 Phase PWM rectifier, the DC link voltage ripple is increased because the input current of the faulty phase is distorted. In this case, the quality of electric power would decrease, and the life time of DC link capacitor is decreased. The open fault is detected by a simple MRAS(Model Reference Adaptive System) without additional hardware sensors, and the tolerant operation carried out by turning on the opposite switch of the faulty switch without any redundancy. By the proposed method, the faulty phase input current can be controlled, so that 3-phase input current is balanced relatively under the faulty condition and the voltage ripple of DC link output is reduced. The validity of the proposed technique is proved on the 6kW 3-phase PWM rectifier system by simulation and experiment.

The Expanded Current Synchronous Detection for Active Power Filters (능동전력필터를 위한 확장된 전류 동기 검출법)

  • 정영국;김우용;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.4
    • /
    • pp.341-347
    • /
    • 2001
  • Harmonics and fundamental reactive current of nonlinear loads in serious unbalanced power condition, are compensated by current synchronous detection(CSD) theory which is also acceptable for single phase power system. But, the CSD theory is not suitable any more, in case of controlled independently harmonics and reactive component. Therefore, a new algorithm, the expanded current synchronous detection(ECSD) theory for a three phase active power filter based on decomposition of fundamental reactive, distorted components, is proposed in this paper. The proposed ECSD theory is experimented and tested comparison with a few power theories under asymmetrical condition in power system.

  • PDF

An Advanced Three-Phase Active Power Filter with Adaptive Neural Network Based Harmonic Current Detection Scheme

  • Rukonuzzaman, M.;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.2 no.1
    • /
    • pp.1-10
    • /
    • 2002
  • An advanced active power filter for the compensation of instantaneous harmonic current components in nonlinear current load is presented in this paper. A novel signal processing technique using an adaptive neural network algorithm is applied for the detection of harmonic components generated by three-phase nonlinear current loads and this method can efficiently determine the instantaneous harmonic components in real time. The control strategy of the switching signals to compensate current harmonics of the three-phase inverter is also discussed and its switching signals are generated with the space voltage vector modulation scheme. The validity of this active filtering processing system to compensate current harmonics is substantiated on the basis of simulation results.

Single Current Sensor Technique considering a Snubber Current and a Modified SVPWM Inverter for AC Motor Drives (스누버 전류를 고려한 개선된 SVPWM 인버터를 이용한 상전류센서없는 전동기 구동)

  • 주형길;신휘범;안희욱;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.399-402
    • /
    • 1999
  • The single sensor technique reconstructing phase currents from the dc-link current without phase current sensors in proposed. When the duration of active vector is too short for the snubber current to reduce, the dc-link current including the snubber current gives large detection error. The solution is presented by analyzing the snubber current and modifying the switching sequences. This scheme is simple, requires only one sampling a period and has good results for detecting the phase currents.

  • PDF

A Novel Current Sensing Method for Low-Cost Vector-Controlled Inverter of AC Motor (저가형 교류전동기 벡터제어 인버터를 위한 새로운 전류측정 방법)

  • Lee, Won-Il;Yoon, Duck-Yong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.950-955
    • /
    • 2013
  • This paper proposes a new low-cost current detection method to implement vector-controlled inverter of 3-phase induction motor or permanent-magnet synchronous motor using 2 shunt resistors instead of expensive Hall current sensors. The proposed method can detect perfect phase currents without current-immeasurable area in all operating conditions of motor. This method uses 2 shunt resistors in Hall current sensor positions conventionally used to detect phase currents. Therefore, it requires accurate analog differential amplifiers to detect voltages across shunt resistors at high electric potential to ground. We show the good solutions which are implemented by voltage-divider resistors networks and the instrumentation amplifiers using several Op Amps at cheap price. Computer simulations and experiments were performed to confirm the effectiveness of proposed method. These results show that proposed method can perfectly detect phase currents without current-immeasurable area in all operating conditions of motor.