• 제목/요약/키워드: Phase-control

검색결과 7,211건 처리시간 0.035초

입각기와 유각기 제어 대퇴의지의 개발 (Development of a Stance & Swing Phase Control Transfemoral Prosthesis)

  • 김신기;김종권;홍정화;김경훈;문무성;이순걸;백영남
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.504-509
    • /
    • 2000
  • In this study, a transfemoral prosthesis system of which stance phase and swing phase are controlled during walking has been developed for the recovery of the biomechanical function of the amputated leg. It consists of a 5 bar link mechanism, a hydraulic-rubber knee damper for stance phase control and a pneumatic cylinder controlled via a microprocessor for stance phase control. The mechanical characteristics and behaviour of the knee damper which absorbs the impact energy generated at the heel contact was investigated. The characteristics of the pneumatic cylinder essential for the speed adaptation of the prosthesis during swing phase was also studied for its mechanical characteristics. The prosthesis was subject to the clinical test ant the gait characteristics obtained were very close to those of normal. The stance and swing controlled prosthesis that were developed in this study showed good stability during the stance phase and showed good controllability during the swing phase.

  • PDF

4상 SRM의 구동 특성해석 (A Characteristic Analysis of Four-Phase SRM)

  • 김태형;안진우;이동희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.988-991
    • /
    • 2004
  • In the paper, a four-phase 16/12 structure Switched Reluctance motor drive is presented. The construction of the stator and the rotor in the motor, the scheme of the rotor position detector and the main circuit of the power converter are described. The comparison of the four-phase 16/12 motor and the four-phase 8/6 motor and the comparison of the four-phase 16/12 motor and the three-phase 12/8 motor are made. In the controller, the PWM control variable-speed control, the commutation control, the four quadrants control, the overvoltage protection, the over current protection and the under voltage protection could be achieved. Tested results of the developed prototype are made.

  • PDF

상전류 센서없는 3상 PWM 3상 정류기의 전류제어 (Current Control of Three-Phase PWM Rectifiers without Phase Current Sensors)

  • 임대식;이동춘
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권2호
    • /
    • pp.123-129
    • /
    • 2000
  • This paper proposes a novel current control method of three-phase PWM rectifiers using estimated currents without phase current sensors. The phase currents are reconstructed from switching states of the rectifier and the measured dc output currents. To eliminate the calculation time delay effect of the microprosessor, the current at the next sampling instant are predicted by a predictive state observer and then are used for feedback control. Experimental results show that the control performance of the proposed system is almost the same as that of the phase current sensor-based system.

  • PDF

4상 16/12극 SRM의 특성해석 (A Characteristic Analysis of Four-Phase 16/12 SRM)

  • 송현수;이동희;안진우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.415-418
    • /
    • 2002
  • In the paper, a four-phase 16/12 structure Switched Reluctance motor drive is presented. The construction of the stator and the rotor in the motor, the scheme of the rotor position detector and the main circuit of the power converter are described. The comparison of the four-phase 16/12 motor and the four-phase 816 motor and the comparison of the four-phase 16/12 motor and the three-phase 12/8 motor are made. In the controller, the PWM control variable-speed control, the commutation control, the four quadrants control, the overvoltage protection, the overcurrent protection and the under voltage protection could be achieved. Tested results of the developed prototype are made.

  • PDF

비 측정 상태변수를 갖는 위상 표준형계통에 대한 가변구조 제어기의 설계 (The Design of Variable Structure Controller for the System in Phase Canonical Form with Incomplete State Measurements)

  • 박귀태;최중경
    • 대한전기학회논문지
    • /
    • 제41권8호
    • /
    • pp.902-913
    • /
    • 1992
  • There have been several control schemes for the single input systems with unmeasurable state variables using variable structure control(VSC) theory. In the previous VSC, the systems must be represented in phase canonical form and the complete measurements for each state variable must be assumed. In order to eliminate these restrictions several VSC methods were proposed. And especially for the systems in phase canonical form with unmeasurable state variables, the reduced order switching function algorithm was proposed. But this method has many drawbacks and can not be used in the case of general form (not phase canonical form) dynamic system. Therefore this paper propose new construction method of switching fuction for the systems in phase canonical form, which reduce the restriction of reduced order switching function algorithm. And this algorithm can be realized for any state representation and adopted in the systems where not all states are available for switching function synthesis or control.

  • PDF

비 최소치목 시스템의 적의 연구 (Adaptive Control of Nonminimum Phase System)

  • Si-Chul Roh
    • 대한전기학회논문지
    • /
    • 제35권11호
    • /
    • pp.529-534
    • /
    • 1986
  • In recent year, there have been much techniques for designing globally stable adaptive control systems when the unknown plant is minimum phase. This paper presents a new seheme for indirect adaptive control structure for nonminimum phase plant of which parameters are estimated from the least-square algorithm. Its effectiveness has been demonstrated by computer simulation carried out for a second-order plant.

  • PDF

SOME PHASE PORTRAITS OF PLANAR CONTROL SYSTEMS

  • Lee, Hyung-Jae;Hwang, Soo-Man
    • 한국수학교육학회지시리즈B:순수및응용수학
    • /
    • 제6권2호
    • /
    • pp.67-77
    • /
    • 1999
  • In this paper we study periodic orbit of some planar control systems and investigate phase portraits of the FSs.

  • PDF

다중 위상 처리구조를 갖는 온실 복합환경제어 알고리즘 설계 (A Design of Greenhouse Control Algorithm with the Multiple-Phase Processing Scheme)

  • 방대욱
    • 서비스연구
    • /
    • 제11권2호
    • /
    • pp.118-130
    • /
    • 2021
  • 본 연구는 온실환경의 변화 정도에 따라 환경제어 구동기를 조합하고 제어할 수 있게 하는 다중 위상 처리구조를 갖는 온실 복합환경제어 알고리즘을 설계하고 검증한다. 복합환경제어 시스템은 온실 내외부에 설치된 센서들이 감지한 정보를 복합환경제어기가 분석하여 작물 생육 환경이 유지되도록 각종 구동기를 복합적으로 작동시키는 시스템이다. 복합환경제어기는 복합환경제어 알고리즘으로 제어를 지시하는데, 복합환경제어 알고리즘은 측정장치의 입력값, 구동장치의 상태값, 초기 설정값 등으로 구동기 제어장치 운영에 필요한 결과값을 산출한다. 기존의 알고리즘들은 대부분 반복주기별로 구동기 제어장치들의 제어절차를 단일 위상에서 수행하는데, 산출값의 오차로 인해 온실환경에 이상변화를 일으킬 수 있다. 제안한 알고리즘은 환경통제, 환경조절, 장치운영이라는 다중 위상에 제어절차를 분산하였다. 즉 매 반복주기 마다 먼저 환경통제 위상에서 환경변화를 감지하고, 다음으로 환경조절 위상에서 해당 환경을 조절할 수 있는 구동기 제어장치들을 조합하며, 마지막으로 장치운영 위상에서 구동기 제어장치가 제어하는데 필요한 제어값을 산출한다. 제안한 알고리즘은 온실 환경요소와 구동기 제어장치 간의 관계를 분석한 결과를 기반으로 하여 설계되었다. 검증 분석에 의하면, 다중 위상 처리구조는 구동기 제어장치의 설정값을 수정 또는 보완할 수 있는 여지를 제공하고, 관련된 환경요소의 변화를 한꺼번에 반영한 구동기 제어장치의 운영을 가능하게 한다. 또한 이 구조는 기존 조건 기반 복합환경제어 알고리즘 개선에 적용할 수 있어서 최적 온실환경 조성을 목표로 하는 복합환경제어 시스템의 개발에 기여할 것이다.

Studies on control mechanism and performance of a novel pneumatic-driven active dynamic vibration absorber

  • Kunjie Rong;Xinghua Li;Zheng Lu;Siyuan Wu
    • Structural Engineering and Mechanics
    • /
    • 제87권2호
    • /
    • pp.117-127
    • /
    • 2023
  • To efficiently attenuate seismic responses of a structure, a novel pneumatic-driven active dynamic vibration absorber (PD-ADVA) is proposed in this study. PD-ADVA aims to realize closed-loop control using a simple and intuitive control algorithm, which takes the structure velocity response as the input signal and then outputs an inverse control force to primary structure. The corresponding active control theory and phase control mechanism of the system are studied by numerical and theoretical methods, the system's control performance and amplitude-frequency characteristics under seismic excitations are explored. The capability of the proposed active control system to cope with frequency-varying random excitation is evaluated by comparing with the optimum tuning TMD. The analysis results show that the control algorithm of PD-ADVA ensures the control force always output to the structure in the opposite direction of the velocity response, indicating that the presented system does not produce a negative effect. The phase difference between the response of uncontrolled and controlled structures is zero, while the phase difference between the control force and the harmonic excitation is π, the theoretical and numerical results demonstrate that PD-ADVA always generates beneficial control effects. The PD-ADVA can effectively mitigate the structural seismic responses, and its control performance is insensitive to amplitude. Compared with the optimum tuning TMD, PD-ADVA has better control performance and higher system stability, and will not have negative effects under seismic wave excitations.

레그 션트저항을 이용한 2상 유도전동기의 상전류 복원 방법 (Phase Current Reconstruction Method of 2-Phase Induction Motor using Leg-Shunt Resistors)

  • 김동기;윤덕용
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1186-1192
    • /
    • 2015
  • This paper proposes an economical method that the phase currents can be measured and reconstructed by means of the leg-shunt resistors in the 3-leg 2-phase vector-controlled inverter for 2-phase induction motor. In general, the phase currents of 2-phase induction motor have been measured using two Hall current sensors. However, because Hall current sensors are expensive, economically disadvantageous to apply in low power applications. The proposed method is verified by computer simulations and experiments to show the good performance of the vector control.