• 제목/요약/키워드: Phase-control

검색결과 7,211건 처리시간 0.032초

인버어터구동 이상서어보 전동기의 마이크로프로세서에 위한 입상제어 (The Phase Contol Method of 2-Phase Servomotor Driven with Microprocessor-based Inverter)

  • 원종수;장도현
    • 대한전기학회논문지
    • /
    • 제36권2호
    • /
    • pp.80-87
    • /
    • 1987
  • This paper describes a new approach to control the two-phase servomotor driven with microprocessor based inverter. Conventional 6-step driving system has some shortcomings such as vibration and loss caused by the harmonic voltage. An attempt has been made to eliminate the harmonic content of output waveform by PWM technique and to simplify the control system by phase control method. In realizing the phase control by PWM technique proposed by this paper, control circuit and algorithm has been suggested. The proposed method has been applied to the speed control system with PI controller to confirm the adaptation of the servo system and experimental results has been compared with the computer simulation.

Oligomerized polyphenols in lychee fruit extract supplements may improve high-intensity exercise performance in male athletes: a pilot study

  • Kawamura, Aki;Hashimoto, Shun;Suzuki, Miho;Ueno, Hiromasa;Sugita, Masaaki
    • 운동영양학회지
    • /
    • 제25권3호
    • /
    • pp.8-15
    • /
    • 2021
  • [Purpose] Excessive reactive oxygen species (ROS) induced by prolonged high-intensity exercise can cause structural and functional damage. Antioxidant polyphenol supplementation, which reduces ROS levels, may improve high-intensity exercise performance. We evaluated the effect of lychee fruit extract, which contains high levels of low-molecular-weight oligomerized polyphenols, on high-intensity exercise performance. [Methods] Ten male athletes were included in an open-label trial that consisted of control and intervention phases, with a 7-day washout period between phases. The participants were administered oligomerized lychee fruit extract for seven days, whereas no intervention was given in the control phase. High-intensity intermittent exercise and the Wingate test were performed. The power output, blood lactate levels, reactive oxygen metabolite levels, biological antioxidant potential, heart rate, and rate of perceived exertion were measured. [Results] The average power output was significantly higher in the intervention phase than in the control phase (P < 0.01), while the change in blood lactate levels was significantly lower in the intervention phase than in the control phase (P < 0.05). The average heart rate was significantly higher in the intervention phase than in the control phase (P < 0.05), without changing the rate of perceived exertion. Although there was no difference in reactive oxygen metabolite levels between the phase, the change in biological antioxidant potential was larger in the intervention phase than in the control phase (P = 0.06). The Wingate test showed no significant differences between the phase. [Conclusion] Short-term loading with oligomerized lychee fruit extract may increase performance during high-intensity intermittent exercise by improving metabolism.

Xylene 대사 효소 활성에 미치는 주.야 시차의 영향 (Effect of Circadian Rhythms on the Xylene Metabolizing Enzyme Activities in Rats)

  • 이혜자;윤종국
    • 한국환경보건학회지
    • /
    • 제27권2호
    • /
    • pp.10-16
    • /
    • 2001
  • To evaluate an effect of circadian variation on the xylene metabolizing enzyme activities, 50% m-xylene in olive oil(0.25 $m\ell$/100g body weight) was intraperitoneally administered to the rats every other day for 6 days both in the night; 24:00 and the day; 12:00. Then animals were sacrigiced at 8hr after last injection of m-xylene. Hepatic microsomal cytochrome p450 contents were more increased both in control and xylene treated rats of night phase than those of day phase. But the activity of hepatic alcohol dehydrogenase(ADH) in control of night phase showed the similar value with that in those of day phase and xylene treated rats of day phase showed an increasing tendency of hepatic ADH activity as those of night phase showing similar activity. Furthermore, control rats of night phase than those of day phase. And by xylene treatment, enzyme activities of rats of day phase were higher tendency in rats of control but those of night phase were somewhat inhibited. Besides, xylene-treated animals of night phase showed increasing tendency of urinary methylhippuric acid concentration compared with those of day phase. On the other hand, liver weight per body weight(%), hepatic lipid peroxide content and serum xanthine oxidase activity were higher in night phase. And the activities of hepatic oxygen free radical metabolizing enzymes such as xanthine oxidase, gluthathione S-transferase, and xylene-treated rats of night phase than those of day phase. In conclusion, it can be hypothesized on the basis of the results that the accumulation rate of m-xylene intermediate metabolite, i.e. m-methylbenzaldehyde in liver tissus may be higher in night phase than in day phase and it may be responsible for higher liver toxicity in bight phase than in day phase.

  • PDF

5상 유도전동기의 속도응답특성 개선을 위한 직접토크제어 시스템 (A Direct Torque Control System for Improving Speed Response of Five-Phase Induction Motor)

  • 김민회;최성운
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.66-74
    • /
    • 2012
  • This paper propose a improved direct torque control(DTC) system for improving operation of five-phase squirrel-cage induction motor(IM). A five-phase IM drives present unique characteristics due to the additional degrees of freedom and also drives possess many others advantage compared with the traditional three-phase motor drive system, such as reducing a amplitude of torque pulsation and increasing the reliability. In order to maximize the torque per ampere, the proposed motor has concentrated windings and the produced back-electromotive force(EMF) is almost trapezoidal, and the motor is supplied with the combined sinusoidal plus third harmonic of currents, there is necessary to controlled 3rd harmonic current. Also a DTC method is advantageous when it is applied to the five-phase IM, because the five-phase inverter provides 32 space vectors in comparison to 8 space voltage vectors into the three-phase inverter drive system. For presenting the superior performance of the proposed DTC, experimental results of speed control are presented using a 32-bit fixed point TMS320F2812 DSP with 1.5[hp] IM.

가변속 구동을 위한 단상 유도전동기의 벡터제어 (Vector Control of Single Phase Induction Motor for Variable Speed Drive)

  • 이득기;이경주;정종진;김흥근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1260-1263
    • /
    • 2000
  • Vector control of a single phase induction machine(SPIM) is usually employed by mechanical methods than electrical ones. The disadvantage of a SPIM has large noise at the starting. Using auxiliary winding which is only utilized for starting, the SPIM can be controlled with the vector control method. Regarding a auxiliary winding one phase, the SPIM is analyzed by the unsymmetrical two phase motor and phase transformation is unnecessary such as three phase IM. Including a auxiliary winding, SPIM is modeled by mathematical getting by component of turns ratio with main to auxiliary winding. It will be take with complicated resultant formula, by comparison to symmetrical three phase TM. For using the vector control theory, it must be decoupled of rotor flux and torque component. stator current is controlled and decoupled. This paper presents a variable-speed control system of SPIM, which to decoupled with flux and torque component and to use machine equivalent circuit referred to rotor, conventionally three phase IM by similar method.

  • PDF

단상 부스트 PFC 컨버터용 가상 DQ 동기좌표계 기반 고성능 전류제어 알고리즘 (High Performance Current Control Algorithm Based on Virtual DQ Synchronous Reference Frame for Single-Phase Boost PFC Converter)

  • 김현근;진성민;이상희;이수형;김준석
    • 전력전자학회논문지
    • /
    • 제22권6호
    • /
    • pp.496-503
    • /
    • 2017
  • This study proposes a high-performance current control algorithm for a diode-bridge-type single-phase boost power factor correction (PFC) converter. The conventional asynchronous single-phase current controllers that directly control AC-type current tend to be accompanied by steady-state errors due to their poor dynamic characteristics for the transient-state, which can be attributed to bandwidth limitations and phase delays. In the proposed algorithm, an ideal current control with minimal phase delays and steady-state errors can be achieved by using a virtual DQ synchronous reference frame and by controlling the synchronous reference frame excluding the frequency component in the single-phase system. The performance of the conventional asynchronous single-phase current controller is compared with that of the proposed algorithm through simulation and experiments, and the results have confirmed the superiority of the latter.

입각기.유각기 동시제어식 대퇴의지의 개발 (Development of a Stance and Swing Phase Control Transfemoral Prosthesis)

  • 김신기;김경훈;문무성;이순걸;백영남
    • 대한기계학회논문집A
    • /
    • 제25권4호
    • /
    • pp.685-694
    • /
    • 2001
  • In this study, a transfemoral prosthesis system of which both stance phase and swing phase are controllable has been developed for the recovery of the biomechanical function of the amputated leg. It consists of a 5 bar link mechanism, a hydraulic-rubber knee damper for stance phase control and a pneumatic cylinder controlled via a microprocessor for stance phase control. The mechanical characteristics of the knee damper which absorbs the impact energy generated at the heel contact were investigated. The characteristics of the pneumatic cylinder essential for the speed adaptation of the prosthesis during swing phase were also studied for its mechanical characteristics. The prosthesis was subject to the clinical tests, and the gait characteristics obtained were very close to those of normal subjects. The stance and swing controlled prosthesis that were developed in this study showed good stability during the stance phase and showed good controllability during the swing phase.

초기 추력편향제어를 위한 자세각제어 구조에 대한 연구 (A Research of Attitude Angle Control Structure for Thrust Vector Control of Missiles at Initial Boosting Phase)

  • 김부민;황익호
    • 전기학회논문지
    • /
    • 제66권10호
    • /
    • pp.1523-1531
    • /
    • 2017
  • In general, the thrust vector control should be fast and stable in the initial launch phase. Two types of conventional controllers, one is for pitch angle control and the other is for pitch rate control, are designed based on the equation of motion without aerodynamics and are compared in the viewpoints of the stability margin and the time response performance. Also analyzed are the rejection capabilities to cope with high aerodynamic disturbances caused by high angle of attacks in initial booting phase. Additionally, time response features at actuator saturation are investigated. Based on those results, we suggest a controller structure which is more suitable for thrust vector control of missiles at initial booting phase.

계통 연계형 태양광 발전 시스템의 위상 동기화를 위한 디지털 PLL 제어 (Digital PLL Control for Phase-Synchronization of Grid-Connected PV System)

  • 김용균;최종우;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.562-568
    • /
    • 2004
  • The frequency and phase angle of the utility voltage are important in many industrial systems. In the three-phase system, they can be easily known by using the utility voltage vector. However, in the case of single phase system, there are some difficulties in detecting the information of utility voltage. In conventional system, the zero-crossing detection method is widely used, but could not obtain the information of utility voltage instantaneously. In this paper, the new digital PLL control using virtual two phase detector is proposed with a detailed analysis of single-phase digital PLL control for utility connected systems. The experimental results under various utility conditions are presented and demonstrate an excellent phase tracking capability in the single-phase grid-connected operation.

전원전압과 DC-link 전압 추정을 통한 3상 컨버터 센서리스 제어 (Sensorless Control of Three Phase Converter using estimated Input Phase-Voltage and DC-link Voltage)

  • 추흥석;박성준;김광태;김철우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1233-1235
    • /
    • 2000
  • A new control method of three phase converter without measuring input phase-voltage and DC-link voltage is proposed. Input phase-voltage of these required voltages is estimated using EKF(Extended Kalman Filter) and DC-link voltage is estimated from the measured line currents and the estimated input phase-voltage. This control method is achieved without PLL(Phase Locked Loop) which senses the angle of input phase-voltage and DC-link voltage sensor. In addition, the proposed method controls high power factor and DC-link voltage utilizing the estimated phase angle. This paper describes the effectiveness of the proposed estimated algorithm through simulations.

  • PDF