• 제목/요약/키워드: Phase-control

검색결과 7,211건 처리시간 0.031초

The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting

  • Ma, Fujun;Luo, An;Xiong, Qiaopo
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.971-982
    • /
    • 2015
  • In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.

전브리지 공진형 인버터에 의한 단상 유도전동기의 디지탈 제어에 관한 연구(2) (A Study on the Digital Control of Single Phase Induction Motor Driven by the Full Bridge Resonant Inverter(2))

  • 노영오;박진길
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제17권5호
    • /
    • pp.86-98
    • /
    • 1993
  • The application of A.C. motor for servo system is rapidly increased according to the recent advance of power electronics and digital control techniques. The induction motor which has a simple structure and needs less maintenance has become to be used widely in the industrial field for the speed and position control recently. In this paper, the full-bridge resonant inverter is applied to the speed control of single phase inducting motor. The digital PID control algorithm is used and the control parameter is determined by the Zigler-Nichols transient response method. The speed control is carried out by the one chip micro-processor(intel EV 8097BH) and control program is developed by the assembly language. By the experimental result, it is confirmed that the speed of single phase induction motor driven by full bridge series inverter can be smoothly controlled by a digital PID controller.

  • PDF

Sliding Mode Control of Three-Phase Four-Leg Inverters via State Feedback

  • Yang, Long-Yue;Liu, Jian-Hua;Wang, Chong-Lin;Du, Gui-Fu
    • Journal of Power Electronics
    • /
    • 제14권5호
    • /
    • pp.1028-1037
    • /
    • 2014
  • To optimize controller design and improve static and dynamic performances of three-phase four-leg inverter systems, a compound control method that combines state feedback and quasi-sliding mode variable structure control is proposed. The linear coordinate change matrix and the state variable feedback equations are derived based on the mathematical model of three-phase four-leg inverters. Based on system relative degrees, sliding surfaces and quasi-sliding mode controllers are designed for converted linear systems. This control method exhibits the advantages of both state feedback and sliding mode control. The proposed controllers provide flexible dynamic control response and excellent stable control performance with chattering suppression. The feasibility of the proposed strategy is verified by conducting simulations and experiments.

결상 시 누전전류 발생과 오동작 방지 기능을 갖는 결상보호기 개발에 관한 연구 (A Study on Development of Open-Phase Protector Having Leakage Current Generation and Incapable Operation Prevention at Open-Phase Accident)

  • 곽동걸
    • 전기학회논문지
    • /
    • 제64권1호
    • /
    • pp.182-187
    • /
    • 2015
  • In the three-phase power system, when any one-phase or two-phases is open-phase, the unbalanced current flows and the single-phase power supplies to three-phase loads. Specially, motor coil and transformer coil receive over-current. As a result, great damage as well as electrical fire can occur to the power system. In order to improve these problems, this paper proposes that an open-phase detection device is designed by a new algorithm using electric potential difference between the resultant voltage of neutral point and ground, and a control circuit topology of open-phase protector is composed of highly efficient semiconductor devices. It improves response speed and reliability. The control algorithm circuit also operates the cut-off of a conventional residual current protective device (RCD) which flows an enforced leakage current to ground wire at open-phase accident. Furthermore, time delay circuit is added to prevent the incapable operation of open-phase protector about instantaneous open-phase not open-phase fault. The time delay circuit improves more reliability.

Phase Advance Control to Reduce Torque Ripple of Brush-less DC Motor According to Winding Connection, Wye and Delta

  • Lee, Tae-Yong;Song, Jun-Young;Kim, Jaehong;Kim, Yong-Jae;Jung, Sang-Yong;Je, Jung-Moon
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.2201-2208
    • /
    • 2014
  • In this research, the characteristics of Brush-less DC (BLDC) motor in accordance with winding connection method, both Y-connection and D -connection, has been identified with design methodology simply. BLDC motor has been designed for both winding connections, and their torque analysis has been performed considering ideal current source analysis and voltage source analysis with 6-step control. In addition, to reduce torque ripple of BLDC motor, caused by coil inductance, on voltage source analysis with 6-step control, we have proposed suitable control method which is Phase Advance Control. It is verified that the torque ripple has been decreased by virtue of phase advance control, advancing and widening conduction angle of switching, via performance analysis by Finite Element Analysis.

Hybrid Control Strategy of Phase-Shifted Full-Bridge LLC Converter Based on Digital Direct Phase-Shift Control

  • Guo, Bing;Zhang, Yiming;Zhang, Jialin;Gao, Junxia
    • Journal of Power Electronics
    • /
    • 제18권3호
    • /
    • pp.802-816
    • /
    • 2018
  • A digital direct phase-shift control (DDPSC) method based on the phase-shifted full-bridge LLC (PSFB-LLC) converter is presented. This work combines DDPSC with the conventional linear control to obtain a hybrid control strategy that has the advantages of linear control and DDPSC control. The strategy is easy to realize and has good dynamic responses. The PSFB-LLC circuit structure is simple and works in the fixed frequency mode, which is beneficial to magnetic component design; it can realize the ZVS of the switch and the ZCS of the rectifier diode in a wide load range. In this work, the PSFB-LLC converter resonator is analyzed in detail, and the concrete realization scheme of the hybrid control strategy is provided by analyzing the state-plane trajectory and the time-domain model. Finally, a 3 kW prototype is developed, and the feasibility and effectiveness of the DDPSC controller and the hybrid strategy are verified by experimental results.

교류전기철도 불평형 전력 개선을 위한 전력보상장치 제어 (Power Compensator Control for Improving Unbalanced Power of AC Electric Railway)

  • 우제훈;조종민;이태훈;차한주
    • 전력전자학회논문지
    • /
    • 제25권3호
    • /
    • pp.213-218
    • /
    • 2020
  • In this study, we propose a control algorithm to reduce the unbalanced characteristics of a three-phase system power caused by the unbalanced load of the AC electric railway. Then, we verify its performance through the design of a power compensator and experiments applying it. Like electric railway systems, a Scott transformer is applied, and the load and single-phase back-to-back converters are connected to the M-phase and T-phase outputs. The back-to-back converter monitors the difference in active power between the unbalanced loads in real-time and compensates for the power by using bidirectional characteristics. The active power is performed through PI control in the synchronous coordinate system, and DC link overall voltage and voltage balancing control are controlled jointly by M-phase and T-phase converters to improve the responsiveness of the system. To verify the performance of the proposed power compensation device, an experiment was performed under the condition that M-phase 5 kW and T-phase 1 kW unbalanced load. As a result of the experiment, the unbalance rate of the three-phase current after the operation of the power compensator decreases by 58.66% from 65.04% to 6.38%, and the excellent performance of the power compensator proposed in this study is verified.

2상 유도전동기의 벡터제어를 위한 저가형 전류측정 방법 (Low-Cost Current Measurement Method for Vector Control of 2-Phase Induction Motor)

  • 오광호;윤덕용
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.634-638
    • /
    • 2015
  • 2상 유도전동기의 벡터제어를 위해서는 전동기로 입력되는 상전류를 실시간으로 측정해야 한다. 일반적으로 전동기의 상전류는 인버터의 출력단에 2개의 홀전류센서를 삽입하여 측정한다. 그러나, 홀전류센서는 가격이 비싸고, 2상 유도전동기용 벡터제어 인버터는 주로 시스템의 가격이 낮은 저전력 응용분야를 대상으로 연구가 진행되고 있으므로 홀전류센서를 사용하는 것은 경제성 측면에서 부적합하다. 따라서, 본 논문에서는 인버터의 출력단에 고가의 홀전류센서 대신 션트저항을 삽입하고, 이것의 양단 전압을 차동 증폭기로 증폭하여 모든 운전영역에서 정밀하게 상전류를 측정하는 방법을 제안한다. 이를 220[V]/360[W]급의 2상 유도전동기 벡터제어 인버터에 적용하였으며, 제안된 방법의 유효성은 컴퓨터 시뮬레이션과 실험을 통하여 검증하였다.

단상 유도전동기의 속도제어 시스템 (Speed Control System of Single Phase Induction Motor)

  • 이득기;이경주;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권5호
    • /
    • pp.229-237
    • /
    • 2001
  • Until recent years, most of the researches for motor drives focus on the high performance drive of the three phase induction motor, and that of the single phase induction motor(SPIM) is out of interest. The SPIM is widely used at low power level because it has the simple construction and economic advantage. In general such machine has both main winding and auxiliary winding. Conventionally, these winding are fed by only one single phase source, and the speed of the motor is not controlled. The SPIM with an auxiliary winding can be treated as an asymmetrical two phase machine. In this paper the space vector Equivalent circuit of SPIM is derived. For vector control of the SPIM the stator current must be decoupled into the flux producing component and the torque producing component. To accomplish decoupling control, the conventional method requires complex calculation and large computation time. We proposed the equivalent circuit referred to the rotor side, in this case only the stator resistances in the direct axis and the quadrature axis are different each other and the other parameters are represented to be equal. Thus the decoupling of the stator current is similar to that of the three phase induction motor. In this paper, the novel vector control system of the single phase induction motor is proposed. To verify the feasibility of this scheme, simulation and experimentation are carried out. The results prove the excellent characteristics for the dynamic response, which confirms the validity of the proposed system.

  • PDF

광두근 분획물이 중대뇌동맥폐쇄에 의한 뇌허혈손상에 미치는 효과(II) -조직화학적 평가를 기준으로- (Effect of Sophora Subprostrata Fractions on Focal Ischemic Brain Damage Induced by Middle Cerebral Artery Occlusion in Rats(II))

  • 최문석;김연섭
    • 동의생리병리학회지
    • /
    • 제19권4호
    • /
    • pp.993-999
    • /
    • 2005
  • This research was peformed to investigate protective effect of Sophora Subprostrata fractions against focal ischemic brain damage after middle cerebral artery(MCA) occlusion using intraluminal suture. Rats were divided into six groups: MCA-occluded group(Control): each administered groups with Sophora Subprostrata total phase(Total), Sophora Subprostrata Aqueous phase (Aqueous), Sophora Subprostrata BuOH phase(BuOH), and Sophora Subprostrata Alkaloid phase(Alkaloid) after MCA-occlusion; sham-operated group(Sham). The right MCA was occluded by A poly-L-lysine coated 4-0 nylon suture thread through the internal carotid artery permanently. Sophora Subprostrata and fractions were administered orally(Smg/ml) for 7 days after MCA-occlusion. The Drain tissue was stained with $2\%$ triphenyl tetrazolium chloride on ischemic brain tissue(2mm section). The results showed that 1) Sophora Subprostrata total phase reduced infarct size and total infarct volume compared to the control group at 24 hours after MCA-occlusion, 2) Sophora Subprostrata Aqueous phase reduced infarct size and total infarct volume compared to the control group at 24 hours after MCA-occlusion, 3) Sophora Subprostrata Alkaloid phase reduced infarct size compared to the control group at 24 hours after MCA-occlusion, but 4) at 7 days after MCA-occlusion, Sophora Subprostrata did not show effective recovery compared with control group. Sophora Subprostrata has protective effects against brain damage at the early stage of focal cerebral ischemia. Sophora Subprostrata total and Aqueous phase produced more pronounced protective effect against focal ischemic brain damage.