• Title/Summary/Keyword: Phase of the resonant capacitor

Search Result 77, Processing Time 0.02 seconds

Soft-Switched PWM DC-DC High-Power Converter with Quasi Resonant-Poles and Parasitic Reactive Resonant Components of High-Voltage Transformer (부분 공진형 소프트 스위칭 PWM DC-DC 고전압 컨버터)

  • 김용주;신대철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.384-394
    • /
    • 1999
  • This paper deals with a fixed frequency full-bridge inverter type DC-DC high-power converter with high frequency high voltage(HFHV) transformer-coupled stage, which operates under quasi-resonant ZVS transition priciple in spite of a wide PWM-based voltage regulation processing and largely-changed load conditions. This multi-resonant(MR) converter topology is composed of a series capacitor-connected parallel resonant tank which makes the most of parasitic circuit reactive components of HFHV transformer and two additional quasi-resonant pole circuits incorporated into the bridge legs. The soft-switching operation and practical efficacy of this new converter circuit using the latest IGBTs are actually ascertained through 50kV trially-produced converter system operating using 20kHz/30kHz high voltage(HV) transformers which is applied for driving the diagnostic HV X-ray tube load in medical equipments. It is proved from a practical point of view that the switching losses of IGBTs and their electrical dynamic stresses relating to EMI noise can be considerably reduced under a high frequency(HF) switching-based phase-shift PWM control process for a load setting requirements.

  • PDF

Design of Input Output Filter of Uninterruptible Power Supply (무정전전원장치(UPS)의 입출력필터설계에 관한 연구)

  • Kim, Je-Hong;Cho, Yang-Heang;Son, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.132-135
    • /
    • 2005
  • A design for the input filter and the output filter of a single-phase uninterruptible power supply (UPS) system is proposed. A filter design example is presented. And also, this dissertation describes a reduction of the DC voltage ripple of a single-phase UPS. The input power of proposed UPS fluctuates with twice frequency of the utility source, which causes DC voltage fluctuation. The reduction of the DC voltage fluctuation requires a large DC link capacitor. The proposed method uses a LC series resonant filter paralleled with a conventional smoothing capacitor. The effectiveness of the proposed method was confirmed by simulation results.

  • PDF

Development of 20kV Pulse Power Charging System (20kV급 Capacitor Charging Power System 개발)

  • Jeong, I.W.;Rim, G.H.;Choi, Y.W.;Lee, H.S.;Kim, J.S.;Ryoo, H.J.;Gusev, G.I.
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.213-214
    • /
    • 2001
  • This paper describes a power supply for a rapid pulse power charging system designed for charging a $0.35{\mu}F$ capacitor to 20kV in approximately 3ms. The power supply should be capable of recharging the load capacitor maximum 300 times within one second. This power supply is based on a series resonant 3-phase inverter followed by the step-up transformers. The experiments have been carried out at different repetition rates and charging voltages.

  • PDF

A Study on Control System Of Induction Heating (유도 가열기의 제어시스템에 관한 연구)

  • Kim, Dong-Un;Sung, Nark-Kuy;Han, Kyung-Hee;Choi, Gi-Soo;Ahn, Gyu-Bok;Lee, Seung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1254-1256
    • /
    • 2000
  • In this paper, a control scheme for induction heating is proposed. The propose scheme estimates, resonant frequency by PI control subbing a phase of output voltage and resonant capacitor voltage. There are would be two advantages in the proposed system over existing induction heating system. One is the rapid resonant frequency estimation. A other is the just control of temperature. Power Circuit is used a inverter stack and transformer rated on 5.5kw.

  • PDF

Novel soft switching FB DC-DC converter for reducing conduction losses (도전손실 저감을 위한 새로운 소프트 스위칭 FB DC-DC 컨버터)

  • Kim, E.S.;Joe, K.Y.;Kye, M.H.;Kim, Y.H.;Yoon, B.D.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.388-391
    • /
    • 1996
  • The conventional high frequency phase-shifted full bridge DC-DC converter has a disadavantage that a circulating current flows through transformer and switching devices during the freewheeling interval Due to this circulating current, RMS current stress, conduction losses of transformer and switching devices are increased. To alleviate this problem, this study provides a novel circulating current free type high frequency soft switching phase-shifted full bridge DC-DC converter which applies the energy recovery snubber(ERS) attached at the secondary side of transformer. The ERS adopted in this study is consisted of three fast recovery diode($Ds_1$, $Ds_2$, $Ds_3$), two resonant capacitor($Cs_1$, $Cs_2$) and a small resonant inductor [(Lr) : It can be ignored because the transformer leakage inductance(Ll) is able to use in stead of inserting the resonant inductor(Lr)]

  • PDF

Characteristics of Non-Isolated OSAKA Converter -Characteristics of Three-Phase Soft-Switching Power Factor Corrected Converter for Large Scale Power Without Three-Phase Transformer-

  • Taniguchi, Katsunori;Shimomori, Wataru;Lee, Hyun-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1383-1386
    • /
    • 2005
  • Non-isolated OSAKA Converter, which removes a three-phase transformer, is described in this paper. The converter switches once in every half cycle of an AC commercial power source. Therefore, it can solve many problems caused by the high frequency operation. The proposed converter achieves the soft-switching operation and the EMI noise can be reduced. In this circuit, the resonant capacitor, which is used for the soft-switching operation, is utilized for the improvement of an input current waveform. To achieve low cost and compact structure, non-isolated OSAKA converter removes a three-phase transformer of the OSAKA converter. By removing the three-phase transformer, three phase currents occur the interferences each other. To avoid the interference, a new switching method for non-isolated OSAKA converter is preposed. The converter can be constructed by the low-speed large power devices. The converter generates the low distorted input current waveforms with high power factor.

  • PDF

A Two State Feedback Active Damping Strategy for the LCL Filter Resonance in Grid-Connected Converters

  • Gaafar, Mahmoud A.;Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1587-1597
    • /
    • 2016
  • A novel active damping strategy for the LCL filter resonance is proposed using the grid current and the capacitor voltage. The proposed technique is deduced in the continuous time domain and a discussion for its discrete implementation is presented. According to the proposed technique, instability of the open loop system, which results in non-minimum phase behavior, can be avoided over wide range of resonant frequencies. Moreover, straightforward co-design steps for both the fundamental current regulator and the active damping loops can be used. A numerical example along with experimental results are introduced to validate the proposed strategy performance over wide range of resonant frequencies.

Control Strategies for Multilevel APFs Based on the Windowed-FFT and Resonant Controllers

  • Han, Yang
    • Journal of Power Electronics
    • /
    • v.12 no.3
    • /
    • pp.509-517
    • /
    • 2012
  • This paper presents control strategies for cascaded H-bridge multilevel active power filters (APFs). A current loop controller is implemented using a proportional-resonant (PR) regulator, which achieves zero steady-state error at target frequencies. The power balancing mechanism for the dc-link capacitor voltages is analyzed and a voltage balancing controller is presented. To mitigate the picket-fence effect of the conventional FFT algorithm under asynchronous sampling conditions, the Hanning Windowed-FFT algorithm is proposed for reference current generation (RCG). This calculates the frequency, amplitude and phase of individual harmonic components accurately and as a result, selective harmonic compensation (SHC) is achieved. Simulation and experimental results are presented, which verify the validity and effectiveness of the devised control algorithms.

An Improved Soft Switching Bi-directional PSPWM FB DC/DC Converter

  • Kim, Eun-Soo;Joe, Kee-Yeon;Kim, Yoon-Ho;Cho, Yong-Hyun;Choi, Won-Beom
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.1042-1046
    • /
    • 1998
  • A new soft switching isolated bi-directional phase shifted pulse width modulation (PSPWM) dc/dc converter is presented. Due to the use of the energy recovery snubber, the isolated bi-directional PSPWM dc/dc converter has a significant reduction of switching losses in the switching devices of the primary and secondary side bridge, respectively. The proposed soft switching bi-directional PSPWM FB dc/dc converter provides an energy recovery snubber which consists of two fast recovery diodes, a resonant capacitor and a resonant inductor. The complete operating principles and simulation results will be presented.

  • PDF

INNOVATIVE INDUCTION-HEATED HIGH-TEMPERATURE STEAMER USING VOLTAGE-FED HIGH-FREQUENCY RESONANT INVERTER

  • Guo, Bin;Nakamizo, Tetsuo;Nishida, Katsumi;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.586-591
    • /
    • 1998
  • This paper presents an innovative prototype of a new conceptual electromagnetic induction-based fluid heating appliance using voltage-fed series capacitor-compensated load resonant high-frequency IGBT inverter with a phase-shifted PWM and a power factor correction schemes. Its operating characteristics in steady-state and dynamic state are illustrated including unique features and evaluated on the basis of its computer simulation and experimental results of 10kw breadboard appliance developed for hot water producer and superheated steamer.

  • PDF