• Title/Summary/Keyword: Phase and Magnitude

Search Result 850, Processing Time 0.02 seconds

Optical Properties of Sputtered Ta2O5 Thin Films Using Spectroscopic Ellipsometty (분광타원법을 이용한 스퍼터된 Ta2O5 박막의 광학적 특성)

  • Kim, Sun-Hee;Lee, Eui-Hyun;Jung, In-Woo;Hyun, Jang-Hoon;Lee, Sung-Young;Kang, Man-Il;Ryu, Ji-Wook
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.133-140
    • /
    • 2009
  • $Ta_{2}O_{5}$ thin films were deposited by RF magnetron sputtering method under various RF power, substrates and oxygen partial pressure. Elliptic constants were measured by using a phase modulated spectroscopic ellipsometer and analyzed with the Tauc-Lorentz dispersion formula and best fit method in the range of 310$\sim$1239 nm. Also, transmittance spectra of the films were measured by UV -Vis spectrophotometer in the range of 300$\sim$1000 nm. From these data, thickness of $Ta_{2}O_{5}$ and surface layer were analyzed and changes of magnitude and shape of dispersion of optical constants according to fabricated conditions were measured. Also, to evaluate thickness and optical constants data analyzed by Tauc-Lorentz dispersion formula, the measured and analyzed transmittance spectra were compared. In result of the comparison, two spectra were in good agreement each other. Accordingly, it indicates that our ellipsometric analysis is valid.

Peritoneal Dialysis in Dogs: 20 cases (2006-2008) (개에서 복막투석 적용: 20 증례 (2006-2008))

  • Nam, So-Jeong;Choi, Ran;Oh, Won-Seok;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.1
    • /
    • pp.23-28
    • /
    • 2009
  • Peritoneal dialysis (PD) is a clinical technique that therapeutically removes toxic solutes from body fluids and normalizes endogenous solutes whose aberrant concentrations disrupt normal physiology. This study retrospectively evaluated clinical outcomes and complications of PD in 20 dogs with renal failure. Blood works (total count of red blood cells (RBC), packed cell volume (PCV), the serum biochemical, and electrolyte values related to renal insufficiency) and complications associated with peritoneal dialysis, and clinical outcomes were recorded before and after PD. Additionally, creatinine reduction ratio (CRR) and urea nitrogen reduction ratio (URR) were calculated for evaluating the efficacy of PD. PD resulted in a significant (p < 0.05) reduction in blood urea nitrogen (BUN) concentration in 19 dogs, while a significant (p < 0.05) reduction in creatinine concentration in 17 dogs. The complications of PD were hypoalbuminemia (12/20, 60%), anemia (10/20, 50%), subcutaneous dialysate leakage (9/20, 45%), bacterial peritonitis (6/20, 30%), dialysate retention (5/20, 25%) and limb edema (4/20, 20%). This study demonstrated that PD was effective in reducing the magnitude of azotemia in dogs with renal failure especially in acute phase, although the complication rate was high but manageable.

Performance Evaluation of Hash Join Algorithm on Flash Memory SSDs (플래쉬 메모리 SSD 기반 해쉬 조인 알고리즘의 성능 평가)

  • Park, Jang-Woo;Park, Sang-Shin;Lee, Sang-Won;Park, Chan-Ik
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.11
    • /
    • pp.1031-1040
    • /
    • 2010
  • Hash join is one of the core algorithms in databases management systems. If a hash join cannot complete in one-pass because the available memory is insufficient (i.e., hash table overflow), however, it may incur a few sequential writes and excessive random reads. With harddisk as the tempoary storage for hash joins, the I/O time would be dominated by slow random reads in its probing phase. Meanwhile, flash memory based SSDs (flash SSDs) are becoming popular, and we will witness in the foreseeable future that flash SSDs replace harddisks in enterprise databases. In contrast to harddisk, flash SSD without any mechanical component has fast latency in random reads, and thus it can boost hash join performance. In this paper, we investigate several important and practical issues when flash SSD is used as tempoary storage for hash join. First, we reveal the va patterns of hash join in detail and explain why flash SSD can outperform harddisk by more than an order of magnitude. Second, we present and analyze the impact of cluster size (i.e., va unit in hash join) on performance. Finally, we emperically demonstrate that, while a commerical query optimizer is error-prone in predicting the execution time with harddisk as temporary storage, it can precisely estimate the execution time with flash SSD. In summary, we show that, when used as temporary storage for hash join, flash SSD will provide more reliable cost estimation as well as fast performance.

Highband Coding Method Using Matching Pusuit Estimation and CELP Coding for Wideband Speech Coder (광대역 음성부호화기를 위한 매칭퍼슈잇 알고리즘과 CELP 방법을 이용한 고대역 부호화 방법)

  • Jeong Gyu-Hyeok;Ahn Yeong-Uk;Kim Jong-Hark;Shin Jae-Hyun;Seo Sang-Won;Hwang In-Kwan;Lee In-Sung
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.21-29
    • /
    • 2006
  • In this Paper a split bandwidth wideband speech coder and its highband coding method are Proposed. The coder uses a split-band approach. where the wideband input speech signal is split into two equal frequency bands from 0-4kHz and 4-8kHz. The lowband and the highband are coded respectively by the 11.8kb/s G.729 Annex E and the proposed coding method. After the LPC analysis, the highband is divided by two modes according to the properties of signals. In stationary mode. the highband signals are compressed by the mixture excitation model; CELP algorithm and W (Matching Pursuit) algorithm. The others are coded by the only CELP algorithm. We compare the performance of the new wideband speech coder with that of G.722 48kbps SB-ADPCM and G.722.2 12.85kbps in a subjective method. The simulation results show that the Performance of the proposed wideband speech coder has better than that of 48kbps G.722 and no better than that of 12.85kbps G.722.2.

Thermotropic Liquid Crystalline Properties of (8-Cholesteryloxycarbonyl)heptanoated Polysaccharides ((8-콜레스테릴옥시카보닐)헵타노화 다당류들의 열방성 액정 특성)

  • Jeong Seung-Yong;Ma Yung-Dae
    • Polymer(Korea)
    • /
    • v.30 no.4
    • /
    • pp.338-349
    • /
    • 2006
  • Fully or nearly fully(8-cholesteryloxycarbonyl)heptanoated polysaccharide derivatives were synthesized by reacting cellulose, amylose, chitosan, chitin, alginic acid, pullulan or amylopectin with (8-cholesteryloxycarbonyl)heptanoyl chloride (CH8C), and their thermotropic liquid crystalline behaviors were investigated. Like in the case of CH8C, all the polysaccharide derivatives formed monotropic cholesteric phases with left-handed helicoidal structures whose optical pitches $({\lambda_m}'s)$ decrease with increasing temperature. Amylopectin derivative also formed a monotropic cholesteric phase with lefthanded helicoidal structures but, in contrast with the other derivatives, did not display reflection colors over the full cholesteric range, suggesting that the helicoidal twisting power of the cholesteryl group highly depends on the branched structure in amylopectin. The thermal stability and degree of order in the mesophase, the magnitude of ${\lambda}_m$ at the same temperature, and the temperature dependence of the ${\lambda}_m$ observed for polysaccharide derivatives were entirely different from those reported for the polymers in which the cholesteryl groups are attached to flexible or semiflexible backbones through flexible spacers. The results were discussed in terms of the difference in the chemical structures of the main and side chains and flexibility of the main chain.

Generation of Korean Ionospheric Total Electron Content Map Considering Differential Code Bias (Differential Code Bias를 고려한 한반도 전리층 총전자수 지도 생성)

  • Lee, Chang-Moon;Kim, Ji-Hye;Park, Kwan-Dong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.29 no.3
    • /
    • pp.293-301
    • /
    • 2011
  • The ionospheric delay is the largest error source in GPS positioning after the SA effect has been turned off in May, 2000. In this study, we used 44 permanent GPS stations being operated by National Geographic Information Institute (NGII) to estimate Total Electron Content (TEC) based on pseudorange measurements phase-leveled by a linear combination with carrier phases. The Differential Code Bias (DCB) of GPS satellites and receivers was estimated and applied for an accurate estimation of the TEC. To validate our estimates of DCB, changes of TEC values after DCB application were investigated. As a result, the RMS error went down by about an order of magnitude; from 35~45 to 3~4 TECU. After the DCB correction, ionospheric TEC maps were produced at a spatial resolution of $1^{\circ}{\times}1^{\circ}$. To analyze the effect of the number of sites used for map generation on the accuracy of TEC values, we tried 10, 20, 30, and 44 stations and the RMS error was computed with the Global Ionosphere Map as the truth. While the RMS error was 5.3 TECU when 10 sites are used, the error reduced to 3.9 TECU for the case of 44 stations.

Processes and Fluxes of Uranium Removal Across the Sediment-Water Interface: A Biogeochemical Approach (해수-퇴적물 경계면을 지나는 우라늄 제거 과정과 플럭스 연구: 생지화학적 접근)

  • Kim, Kee-Hyun;Cho, Jin-Hyung;Lee, Jae-Seong
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.4 no.3
    • /
    • pp.188-197
    • /
    • 1999
  • In order to estimate the uranium flux from seawater to sediments, we took pore water samples and deployed benthic chambers on seafloor of Chonsu Bay, Korea. The uranium flux across the sediment-water interface was estimated from the pore water to be 0.112-0.566 mg/$m^2yr$, corresponding to a removal flux of $4.3-21.5{\times}10^7$ gU/yr for the entire Yellow Sea. Nutrient fluxes from sediment to bottom water were estimated to be 135.6 mmol/$m^2yr$ for ammonia, 228.2 mmol/$m^2yr$ for nitrate, 36.8 mmol/$m^2yr$ for phosphate and 23.9 mmol/$m^2yr$ for silicate. The redox boundary, based on the distribution of pore water nitrate and solid phase manganese, was located at 3-5 cm below the sediment surface. Phosphate flux obtained by benthic chambers was 28.S mmol/$m^2yr$. On the other hand, estimates of uranium and silicate fluxes were orders of magnitude greater than those based on pore water profiles. Flux estimates on the basis of pore water concentration is believed to have greater reliability than those obtained from benthic chamber data.

  • PDF

B1+ Homogenizaion over Whole Field of View in High Field MRI (고자장 MRI에서의 영상 영역에 대한 B1+ 균질성)

  • Kim, Hong-Joon;Son, Hyeok-Woo;Cho, Young-Ki;Yoo, Hyoung-Suk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.96-100
    • /
    • 2012
  • In high static field magnetic resonance imaging(MRI) systems, $B_0$ fields of 7 T and 9.4 T, the impressed RF field shows larger inhomogeneity than in clinical MRI systems with B0 fields of 1.5 T and 3.0 T. In multi-channel RF coils, the magnitude and phase of the input to each coil element can be controlled independently to reduce the non-uniformity of the impressed RF $B_1^+$ field. The convex optimization technique has been used to obtain the optimum excitation parameters with iterative solutions for homogeneity in a selected ROI(Region of Interest). To demonstrate the technique, the multichannel transmission line coil was modeled together with a human head phantom at 400 MHz for the 9.4 T MRI system and $B_1^+$ fields are obtained. In this paper, all the optimized $B_1^+$ in each isolated ROIs are combined to achieve significantly improved homogeneity over the entire field of view. The simulation results for 9.4 T MRI systems are discussed in detail.

Gamma-ray-induced skin injury in the mini-pig: Effects of irradiation exposure on cyclooxygenase-2 expression in the skin (감마선조사에 의한 돼지 피부장애에 cyclooxygenase-2의 발현변화)

  • Kim, Joong Sun;Park, Sunhoo;Jang, Won Seok;Lee, Sun Joo;Lee, Seung Sook
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.65-72
    • /
    • 2015
  • The basic concepts of radiation-induced skin damage have been established, the biological mechanism has not been studied. In this study, we have examined the effects of gamma rays on skin injury and cyclooxygenase(COX)-2 expression. Gamma irradiation induced clinicopathological changes in a dose- and time-dependent manner in mini-pig skin. The histological changes were consistent with the changes in gross appearance at 12 weeks after irradiation. After three days' irradiation, apoptotic cells in the basal layer were found more frequently in irradiated skin than in normal skin, with the magnitude of the effect being dose-dependent. The thickness of the epidermis transiently increased 3 days after irradiation, and then gradually decreased, although changes in the epithelial thickness of the irradiated field were not observed with irradiation doses over 50 Gy. In the epithelium, there was an initial degenerative phase, during which the rate of basal cell depletion was dependent on the radiation dose (20-70 Gy). One week after irradiation, COX-2 expression was mostly limited to the basal cell layer and was scattered across these cells. High COX-2 expression was detected throughout the full depth of the skin after irradiation. The COX-2 protein is upregulated after irradiation in mini-pig skin. These histological changes associated with radiation exposure dose cause the increased COX-2 expression in a dose-dependent fashion.

Experimental Vibration Analysis of Vehicle Body-Engine Systems by Transfer Function Synthesis Method (전달함수합성법에 의한 차체-엔진계의 실험적 진동해석)

  • 정의봉;안세진;김원영
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.289-295
    • /
    • 1995
  • 구조물의 동적부하에 대한 동적변형 응답을 정확히 예측하고, Over Design이나 Under Design이 아닌 합리적인 설계방안의 개발은 중요한 과제이다. 동적강도해석이나 소음 승차감과 같은 진동 및 충격에 기인하는 제반 문제를 복잡한 구조물을 대상으로 합리적으로 처리하기 위한 Dynamic Design Analysis는 높은 신뢰성의 추구와 더불어 필요불가결한 기술이 되고 있다. 동적해석 방법으로는 현재 유한요소법이 널리 사용되고 있으며 여러 종류의 범용 프로그램들이 보급되어 있는 실정이다. 그러나 특히 동적문제에 있어서는 형상이나 거동이 복잡한 구조물의 경우, 또는 차량의 차체와 같이 많은 장착물이 부착된 경우에는 유한요소법의 적용이 곤란하여, 지금까지 대처할 수 있는 유용한 방법이 없었다. 따라서 비교적 용이하고 간단하게 적용가능한 진동실험을 기초로 한 구조물의 동적 응답해석 및 설계 방안의 개발이 필요하다. 본 연구에서는 진동시험으로 얻어진 부분구조물의 응답특성과 결합특성으로부터 결합 후의 응답특성을 예측할 수 있는 방법을 전달함수합성이론을 기초로하여 프로그래밍 package화 한다. 그리고 평판구조물에 대하여 진동시험과 컴퓨터 시뮬레이션을 통하여 개발된 방법의 타당성을 검증한다. 또한 실제 차량에서 차체만의 진동시험과 엔진의 자유진동시험에 의한 시험데이터로부터 차체와 엔진이 마운트 결합된 후의 진동특성을 예측한다. 진동시험시에 입력과 출력에 노이즈가 필연적으로 혼입되어 주파수응답함수의 크기(magnitude)와 위상(phase)을 왜곡시킨다. 특히 위상의 왜곡은 복소수연산을 하는 전달함수합성법의 결과에 중요한 영향을 미치게 된다. 본 연구에서는 데이타 획득시 입력과 출력의 시간지연으로 생기는 위상왜곡을 보정하는 방법을 제시하고, 그 개선 정도를 조사한다.는 소견의 확실도로서 가능성을 표현한 것이다. 예를 들면, 진동진폭 스펙트럼상에 2X 성분이 상당히 크게 나타나 정렬불량의 가능성이 0.7 정도라고 판정하는 것 등은 이러한 수치적진리치를 이용하는 방법이다. 그러나 상기의 수치적 표현만으로는 확실도를 한개의 수치로서 대표하게 하는 것은 진단의 정밀도에 문제가 있을 것으로 생각된다. 따라서 언어적진리치가 도입되어 [상당히 확실], [확실], [약간 확실] 등의 언어적인 표현을 이용하여 애매성을 표현하게 되었다. 본 논문에서는 간이진단 결과로부터 추출된 애매한 진단결과중에서 가장 가능성이 높은 이상원인을 복수로 선정하고, 여러 종류의 수치화할 수 없는 언어적(linguistic)인 정보ㄷㄹ을 if-then 형식의 퍼지추론으로 종합하는 회전기계의 이상진단을 위한 정밀진단 알고리즘을 제안하고 그 유용성을 검토한다. 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on bot

  • PDF