• Title/Summary/Keyword: Phase and Magnitude

Search Result 850, Processing Time 0.024 seconds

3-Phase Power Quality Disturbance Generator with Phase Jump Function (위상급변 기능을 갖는 3상 전력품질 외란발생기)

  • Lee, B.C.;Choi, S.H.;Paeng, S.H.;Park, S.D.;Choi, N.S.;Kim, I.D.;Chun, T.W.;Kim, H.G.;Nho, E.C.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.5
    • /
    • pp.463-470
    • /
    • 2006
  • This paper deals with a new 3-phase power quality disturbance generator. The proposed generator can provide phase jump as well as voltage sag, swell, outage, unbalance, and over and under voltage. The operating principle of the generator is described in each mode of disturbance. The magnitude of the phase jump is analysed and it is found that the magnitude is the function of the turn-ratios of the transformers consisting the generator. The scheme has simple structure compared with the conventional one, and the major components of the proposed scheme are SCR thyristor and transformer, which guarantees high reliability and cost-effective implementation of the generator. Furthermore, high efficiency can be obtained because there is no PWM switching of the semiconductor devices, and it is easy to control the system. Simulations are carried out to confirm the operation in each disturbance mode, and experiments has been done with 5kVA power rating. The usefulness of the proposed scheme is verified through simulation and experimental results. It is expected that the scheme can be applied to the performance test of the custom power devices such as UPS, DVR, DSTATCOM, and SSTS with cost-effective system.

Quantitative Analysis and Comparisons between In-Phase Control and Energy-Optimized Control for Series Power Quality Controllers

  • Xinming, Hunag;Jinjun, Liu;Hui, Zhang
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.553-566
    • /
    • 2009
  • In-phase control and energy-optimized control are the two major control strategies proposed for series power quality controllers (SPQC). However quantitative analysis and comparison between these two control strategies is quite limited in previous publications. In this paper, an extensive quantitative analysis is carried out on these two control strategies through phasor diagram approach, and a detailed quantitative comparison is conducted accordingly. The load current is used as the reference phasor, and this leads to a simpler and clearer phasor diagram for the quantitative relationship. Subsequently detailed analysis of SPQC using in-phase control and energy-optimized control are provided respectively, under different modes both for under voltage/voltage sag and for over voltage/voltage swell. The closed form analytic expressions and the curves describing SPQC compensation characteristics are obtained. The detailed system power flow is figured out for each mode, and the detailed quantitative comparison between the two control strategies is then carried out. The comparison covers several aspects of SPQC, such as required compensating voltage magnitude, required capacity of energy storage component, and maximal ride-through time. In the end, computer simulation and prototype experimental results are shown to verify the validity of all the analysis and the result of the comparison.

Comparative Analysis of Offset Voltage PWM and $V_{max}-V_{mid}$ PWM Method for 3 Phase Matrix Converter (3상 매트릭스 컨버터에 사용되는 옵셋전압 PWM 방법과 $V_{max}-V_{mid}$ PWM 방법의 비교분석)

  • Cha, Han-Ju;Kim, Woo-Jung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.285-291
    • /
    • 2009
  • In this paper, comparative analysis of offset voltage PWM method and $V_{max}-V_{mid}$ PWM method for three-phase matrix converter is addressed by using a simple analytical and graphical method. Offset voltage PWM method calculates PWM patterns in terms of offset voltage and variable slope of carrier, and it simplifies matrix converter modulation algorithm significantly. $V_{max}-V_{mid}$ PWM method generates patterns by using two phases and maintaining a remaining phase to base phase, and it is implemented in the industrial products. The most important performance criterion of modulation method is a magnitude of current ripples and it is analytically modelled. The graphical illustration of theses complex multivariable functions make per-carrier cycle and per fundamental cycle behavior of two PWM methods understood. Two modulation methods are analysed with the analytical formulas and graphics, and the analysis shows offset voltage PWM method is superior to $V_{max}-V_{mid}$ PWM method with respect to input current ripples and output voltage ripples.

A numerical study on the vaporization of a droplet considering internal circulating flow in the presence of an oscillating flow (진동하는 유동장하에서 내부 순환 유동을 고려한 액적의 증발에 관한 수치적 연구)

  • Ha, Man-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1700-1716
    • /
    • 1996
  • The two-dimensional, unsteady, laminar conservation equations for mass, momentum, energy and species transport in the gas phase and mass, momentum and energy in the liquid phase are solved simultaneously in spherical coordinates in order to study heating and vaporization of a droplet entrained in the oscillating flow. The numerical solution gives the velocity and temperature distribution in both gas and liquid phase as a function of time. When the gas flow oscillates around an vaporizing droplet, the liquid flow circulates in the clockwise or counterclockwise direction and the temperature distribution in the liquid phase changes its shapes, depending on the gas fow direction. When the gas flow changes its direction of circulating liquid flow is opposite to the gas flow, forming two vortex circulating in the opposite direction. During the heating period, the difference in the maximum and minimum temperature is large, followed by the almost uniform temperature slightly below the boiling temperature. The mass and heat transfer from the droplet depend on the droplet temperature, droplet diameter and the magnitude of relative velocity, giving the droplet lifetime different from the d$^{2}$-law.

The Comparison of Characteristics of Trunk Motion between Energy Walking and Normal Walking (에너지보행과 일반보행에서 몸통운동의 특성 비교)

  • Shin, Je-Min
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.133-145
    • /
    • 2007
  • The purpose of this paper was to compare of difference between energy walking and normal walking. Subjects were selected 8 male undergraduates. The kinematic variables of a pelvis and a thorax were analysed at the take off and contact with 3d cinematography. In addition to the variables, the phase plot angle was calculated in order to definite characteristics in the phase space. The pelvic angle and angular velocity showed significant differences in the flexion/extension between two walking patterns. The pelvic angle and angular velocity were increasing when walking speed was increasing and magnitude of the variables of energy walking was larger than corresponding values for normal walking. On the other hand, the thoracic angle demonstrated significant differences in the flexion/extension and rotation between two walking patterns. The angles of energy walking were smaller in the flexion/extension and were larger in the rotation than the angle of normal walking. The kinematic characteristics of energy walking were also showed clearly significant differences in the range of motion and the relative angle of the trunk. The angle of phase plot only showed demonstrated a significant difference in the rotation at contact between the two walking patterns.

Balance Recovery Mechanisms Against Anterior Perturbation during Standing (직립자세에서의 전방향 동요 시 균형회복 기전)

  • 태기식;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.24 no.5
    • /
    • pp.435-442
    • /
    • 2003
  • In this paper, biomechanical aspects of dynamic대학교postural responses against forward perturbations were experimentally determined simultaneous measurements of joint angles, accelerations. EMG activations, center of pressure(CoP) movements and ground reaction forces(GRF), Thirteen young healthy volunteers, stood on a flat platform, were translated into the forward direction by an AC servo-motor at two separate velocities(0.1m and 0.2m/s). In order to recover postural balance against the forward perturbation, joint motions were observed in the sequence of the ankle dorsiflexion, the knee flexion and then the hip flexion during the later acceleration phase. Both acceleration patterns at the heel and the sacrum were shown the forward acceleration pattern during the later acceleration phase and early of constant velocity phase as increasing platform velocity, respectively. Tibialis anterior(TA) for the ankle dorsiflexion and biceps femoris(BF) for the knee flexion. the primary muscle to recover the forward perturbation, was activated during the half of acceleration phase. Ankle strategy was used for slow-velocity perturbation, but mixed strategy of both ankle and hip used for the fast-velocity perturbation. In addition, parameters of perturbation such as timing and magnitude influenced the postural response against the perturbation.

Improvement of Group Delay and Reduction of Computational Complexity in Linear Phase IIR Filters

  • Varasumanta, Saranuwaj;Sookcharoenphol, Dolchai;Sriteraviroj, Uthai;Janjitrapongvej, Kanok;Kanna, Channarong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.955-959
    • /
    • 2003
  • A technique for realizing linear phase IIR filters has been proposed by Powell-Chau which gives a real-time implementation of H(z-1).H(z), where H(z) is a causal nonlinear phase IIR filter. Powell-Chau system is linear but not timeinvariant system. Therefore, that system has group delay response that exhibits a minor sinusoidal variation superimposed on a constant value. In the signal processing, this oscillation seriously degrade the signal quality. Unfortunately, that system has a large sample delay of 4L and also more computational complexity. Proposed system is present a reduced computational complexity technique by moved the numerator polynomial of H(1/z) out to cascade with causal filter H(z) and remain only all-pole of H(1/z), then applied truncated infinite impulse response to finite with truncated IIR filtel $H_L$(z) and L sample delay to subtract the output sequence from the top and bottom filter. Proposed system is linear time invariance and group delay response and total harmonic distortion are also improved.

  • PDF

An Efficient Design Method of Linear-Phase Prototype Lowpass Filter for Near-Perfect Reconstruction Pseudo-QMF Banks (근접 완전재생 Pseudo-QMF 뱅크를 위한 선형위상 프로토타입 저역통과 필터의 효율적인 설계 방법)

  • Jeon, Joon-Hyeon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.3C
    • /
    • pp.271-280
    • /
    • 2008
  • M channel near-perfect-reconstruction(NPR) pseudo-QMF banks are a hybrid of conventional pseudo-QMF design and spectral factorization approach where the analysis and synthesis filters are cosine-modulated versions of the prototype-lowpass filter(p-LPF). However, p-LPF H(z) does not have linear-phase symmetry as well as magnitude-distortion optimization since it is obtained by spectral factorization of $2M^{-th}$ band filter $G(z)=z^{-(N-1)}H(z^{-1})H(z)$. A fair amount of attention, therefore, has been focused on the design of filter banks for reducing only alias-cancellation distortion without reconstructed-amplitude distortion. In this paper, we propose a new method for designing linear-phase p-LPF in NPR pseudo-QMF banks, which is based on Maxflat(maximally flat) FIR filters with closed-form transfer function. In addition, p-LPF H(z) is optimized in this approach so that the 2M-channel overall distortion response represented with $G(z)=H^2(z)$ approximately becomes an unit magnitude response. Through several examples of NPR pseudo-QMF banks, it is shown that the peek ripple of the overall magnitude distortion is less than $3.5{\times}10^{-4}\;({\simeq}-70dB)$ and analysis/synthesis filters have the sharp monotone-stopband attenuation exceeding 100 dB.

A Study on Current Ripple Reduction Due to Offset Error and Dead-time Effect of Single-phase Grid-connected Inverters Based on PR Controller (비례공진 제어기를 이용한 단상 계통연계형 인버터의 데드타임 영향과 옵셋 오차로 인한 전류맥동 저감에 관한 연구)

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.201-208
    • /
    • 2015
  • The effects of dead-time and offset error, which cause output current distortion in single-phase grid-connected inverters are investigated this paper. Offset error is typically generated by measuring phase current, including the voltage unbalance of analog devices and non-ideal characteristics in current measurement paths. Dead-time inevitably occurs during generation of the gate signal for controlling power semiconductor switches. Hence, the performance of the grid-connected inverter is significantly degraded because of the current ripples. The current and voltage, including ripple components on the synchronous reference frame and stationary reference frame, are analyzed in detail. An algorithm, which has the proportional resonant controller, is also proposed to reduce current ripple components in the synchronous PI current regulator. As a result, computational complexity of the proposed algorithm is greatly simplified, and the magnitude of the current ripples is significantly decreased. The simulation and experimental results are presented to verify the usefulness of the proposed current ripple reduction algorithm.

High Speed Grid Voltage Detection Method for 3 Phase Grid-Connected Inverter during Grid Faults (전원사고 시 3상 계통연계 인버터의 전원 전압 고속 검출 방법)

  • Choi, Hyeong-Jin;Song, Seung-Ho;Jeong, Seung-Gi;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.5
    • /
    • pp.65-72
    • /
    • 2009
  • The new method is proposed to improve high speed detection of grid voltage phase and magnitude during a voltage dip due to a grid faults. Usually, A LPF(Low Pass Filter) is used in the feedback loop of PLL (Phase Locked Loop) system because the measured grid voltage contains harmonic distortions and sensor noises. so, a new design method of the loop gain of the PI -type controller in the PLL system is proposed with the consideration of the dynamics of the LPF. As a result, a better transient response can be obtained with the proposed design method. The LPF frequency and PI controller gain are designed in coordination according to the steady state and dynamic performance requirement. This paper shows the feasibility and the usefulness of the proposed methods through the computer simulation and the lab-scale experiments.