• 제목/요약/키워드: Phase Separation test

검색결과 124건 처리시간 0.021초

Effects of surface modification with hydroxyl terminated polydimethylsiloxane on the corrosion protection of polyurethane coating

  • Jeon, Jae Hong;Shon, MinYoung
    • Corrosion Science and Technology
    • /
    • 제13권5호
    • /
    • pp.170-177
    • /
    • 2014
  • Polyurethane coating was designed to give a hydrophobic property on its surface by modifying it with hydroxyl terminated polydimethylsiloxane and then effects of surface hydrophobic tendency, water transport behavior and hence corrosion protectiveness of the modified polyurethane coating were examined using FT-IR/ATR spectroscopy, contact angle measurement and electrochemical impedance test. As results, the surface of polyurethane coating was changed from hydrophilic to hydrophobic property due primarily to a phase separation tendency between polyurethane and modifier by the modification. The phase separation tendency is more appreciable when modified by polydimethylsiloxane with higher content. Water transport behavior of the modified polyurethane coating decreased more in that with higher hydrophobic surface property. The decrease in the impedance modulus ${\mid}Z{\mid}$ at low frequency region in immersion test for polyurethane coatings was associated with the water transport behavior and surface hydrophobic properties of modified polyurethane coatings. The corrosion protectiveness of the modified polyurethane coated carbon steel generally increased with an increase in the modifier content, confirming that corrosion protectiveness of the modified polyurethane coating is well agreed with its water transport behavior.

Two-Phase Flow through a T-Junction

  • Tae Sang-Jin;Cho Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권1호
    • /
    • pp.28-39
    • /
    • 2006
  • Two-phase flow through a T-junction has been studied by numerous researchers so far. The dividing characteristics of the gas and liquid phases at the T-junction are very complicated due to a lot of related variables. The prediction models have been suggested by using experimental data for a specific condition or working fluid. But, they showed the application limitation for the most of the other conditions or fluids. Since most of them are applicable for their own experimental range, the generalized model for the wide range of conditions and fluids is needed. Even though it's not available now, some of the models developed for air-water flow at a T-junction might be applicable for the part of refrigerants with some modifications. Especially, for the two-phase flow of refrigerants at the T-junction, very few studies have been performed. Further experimental study is required to be performed for the wide range of test conditions and fluids to predict properly the two-phase flow distribution and phase separation through the T-junction.

Mathematical Morphology Guided Automatic Unwrapping Isoclinic Phase Map in White Light Photoelasticity

  • Liu, Xiaomeng;Dai, Shuguang
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.643-648
    • /
    • 2015
  • By comparing the results calculated by atan() and atan2() functions, the correctly estimated region of isoclinic phase map is determined using morphological techniques. The isoclinic phase map is automatically unwrapped in the true phase range -π/2 to π/2. Demonstrations of the method on a disc and a ring under diametral compression are performed. Test results compare well with the theoretical results. Furthermore, the influences of principal stress direction and the range of isoclinic phase upon stress separation are discussed.

Small Punch Test for the Evaluation of Thermal Aging Embrittlement of CF8 Duplex Stainless Steel

  • Cheon, Jin-Sik;Kim, In-Sup;Jang, Jae-Gyoo;Kim, Joon-Gu
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(3)
    • /
    • pp.79-84
    • /
    • 1996
  • Small punch test was performed on CF8 duplex stainless steel aged at 370 and 400$^{\circ}C$ up to 5,000 h to evaluate the degree of the thermal aging embrittlement. At room temperature, the SP load-displacement curve was in a similar shape to those of ferritic steels and had a good reproducibility in spite of two-phase structure. The aging heat treatment resulted in a slight increase of the yield strength. As test temperature was lowered, the SP load showed a sudden drop followed by serrations before the SP specimen was fractured, resulting from the cracking of ferrite phase. The extent of thermal embrittlement was assessed in terms of the SP energy. Aging treatment at higher temperature led to a larger shift in the transition temperature and the corresponding change in the fracture mode. The main cause of the degradation was the embrittlement of ferrite phase. Additionally the phase boundary separation profoundly contributed to the degradation of the specimen aged at 400$^{\circ}C$.

  • PDF

중공사형 기체분리막 모듈을 이용한 바이오가스의 분리 및 정제 (Separation and Purification of Bio Gas by Hollow Fiber Gas Separation Membrane Module)

  • 고형철;하성용;우승문;남상용;이병성;이충섭;최휘문
    • 멤브레인
    • /
    • 제21권2호
    • /
    • pp.177-192
    • /
    • 2011
  • 바이오 가스의 분리와 정제를 위해 셀룰로오스 트리아세테이트(CTA) 고분자를 이용하여 중공사형 기체분리막을 상분리법에 의해 제조하고, 제조된 기체분리막을 사용하여 유효 막면적이 0.17 $m^2$인 중공사형 기체분리막 모듈을 제조하였다. 제조된 기체분리막 모듈의 순수 기체투과도틀 메탄, 산소, 이산화탄소에 대하여 측정하였다. 메탄의 투과도는 평균 0.46 GPU를 나타내었으며, 이산화탄소의 투과도는 평균 18.52 GPU였으며 이때 ${\alpha}CO_2$/$CH_4=40.4$를 나타내어 매우 높은 선택도를 나타내었다. 순수 가스 투과 테스트 후 혼합 가스에 대한 분리 정제 테스트를 4가지 모사가스에 대하여 진행하였으며 1 stage, 2 stage, 3 stage로 기체분리막 모듈을 구성하여 stage cut의 변화에 따른 각 부분에서 발생되는 기체의 농도 및 유량을 측정하였다. 1 stage에서는 stage cut이 상승함에 따라 메탄의 농도가 상승하는 것을 알 수 있었으며, 메탄 회수 효율은 떨어지는 것을 알 수 있었다. 2 stage 테스트에서는 1 stage와 유사한 거동을 보이는 것을 알 수 있었으며 메탄의 회수 효율은 1 stage보다 상승하는 것을 알 수 있었다. 바이오 가스 내에 존재하는 메탄의 손실을 줄이기 위해 3 stage 테스트를 진행하였으며, 그 결과 메탄가스의 손실율을 5% 이내로 줄일 수 있는 모듈의 배열을 찾아내었다.

케토프로펜-${\beta}$-시클로덱스트린 고체분산체의 마이크로캅셀화 및 제어 방출 (Preparation and Controlled Release of Microcapsules Containing $Ketoprofen-{\beta}-Cyclodextrin$ Solid Dispersion)

  • 전인구;박정화
    • Journal of Pharmaceutical Investigation
    • /
    • 제22권1호
    • /
    • pp.33-40
    • /
    • 1992
  • This study was aimed to control the release characteristics of ketoprofen by microencapsulating $ketoprofen-{\beta}-cyclodextrin\;(KF-{\beta}-CyD)$ solid dispersion with Eudragit RS by the phase separation method using a nonaqueous vehicle. KF alone was also microencapsulated with Eudragit RS by the evaporation process in water phase. The results obtained showed that it was not possible to microencapsulate KF alone by phase separation in a chloroform-cyclohexane system while it was easy to microencapsulate $(KF-{\beta}-CyD)$ solid dispersion system. For the microcapsules, the release test was performed in the first fluid (pH 1.2) and the second fluid (pH 6.8) of K.P.V disintegration medium at $37^{\circ}C$. The release of KF from $(KF-{\beta}-CyD)$ solid dispersion microcapsules (1:1 core wall ratio) was more sustained than that from KF microcapsules, and followed zero-order kinetics. Especially, solid dispersion microcapsules showed pH-independent release patterns with higher wall to core ratio (1:1 w/w).

  • PDF

사각 고정자 철심을 가지는 삼상 유도전동기의 고정자 철심 절단 각에 따른 전류 특성 연구 (The Study on Current Characteristic according to Core Cutting Degree in Three-Phase Induction Motor with Rectangular Stator Core)

  • 임종빈;김승주;김광수;이형우;김솔;이주
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.1649-1654
    • /
    • 2009
  • Induction motors widely use in industry because structure is simple and hard and cost is generally cheap and they are easy to control. In recently, because of saving steel, ventilation and benefit of frame fixing, rectangular core type induction motors use in industry more and more. This paper presents current characteristic according to stator core cutting degree in three-phase induction motor (IM) with rectangular stator core. According to stator cutting degree, magnetic saturation and paths of flux are changed. Because of these situations, phase currents are unbalance and are produced harmonic components and they cause decrease of efficiency. We analyze each $10^{\circ}$ from $0^{\circ}$ to $30^{\circ}$ using 2-D finite element analysis (FEA). Optimal stator cutting core degree selection supplies stable currents and efficiency improvement. In this paper, loss separation test was executed by IEEE Std. 112-98 Method B and we compare with the result of loss separation by Simulation using FEM and by Experiment.

  • PDF

인버터 구동 3상 유도전동기의 효율 불확도 평가 (Evaluation of the Efficiency Uncertainty for an Inverter-fed Three-Phase Induction Motor)

  • 이호현;박한석;전희득;김대경;우경일
    • 전기학회논문지
    • /
    • 제67권6호
    • /
    • pp.724-729
    • /
    • 2018
  • This paper presented an evaluation method for the efficiency uncertainty of an inverter-fed three-phase induction motor using FEM. The motor efficiency in the FEM is calculated by the IEC 60034-2-3 as in the actual test. In the process of evaluating the efficiency uncertainty, the difference between the finite element method and the actual test is the method of calculating the type-A / B standard uncertainty of the input quantity to estimate the efficiency and each losses. For the input quantities which can confirm the instantaneous values with respect to time, the type-A standard uncertainty in the FEM is calculated from the RMS values or average values having separate periods in the steady state. And, the type-B standard uncertainty in the finite element method is assumed to be zero. Also, this paper compared and analyzed the efficiency uncertainty evaluated by the proposed method and the efficiency uncertainty through the actual test.

Alternative chromatographic method for the assay test of terbutaline and salbutamol using ionic liquid assisted aqueous mobile phase

  • Mai, Xuan-Lan;Choi, Yusung;Truong, Quoc-Ky;Nguyen, Thi-Ngoc-Van;Han, Sang Beom;Kim, Kyeong Ho
    • 분석과학
    • /
    • 제33권4호
    • /
    • pp.169-176
    • /
    • 2020
  • Separation of basic compounds using reverse phase chromatography on a silica-based stationary phase represents a major challenge, because of the interaction between the cationic sites of the basic compounds with the anionic silanols of the stationary phase. This study presents a simple, reliable, and organic solvent - free liquid chromatographic method for the determination of terbutaline and salbutamol, in which a room temperature ionic liquid (RTIL) is used as mobile phase additive. We investigated various mobile phase parameters affecting the retention of the two compounds, such as types and concentration of RTILs and, pH of the mobile phase were investigated. The developed method was validated according to International Conference on Harmonization (ICH) guidelines and successfully applied effectively to determine salbutamol sulfate in pharmaceutical preparations.

Chiral Purity Test of Bevantolol by Capillaryelectrophoresis and High Performance Liquid Chromatography

  • Long, Pham Hai;Trung, Tran Quoc;Oh, Joung-Won;Kim, Kyeong-Ho
    • Archives of Pharmacal Research
    • /
    • 제29권9호
    • /
    • pp.808-813
    • /
    • 2006
  • Two methods for the chiral purity determination of bevantolol were developed, namely capillary electrophoresis (CE) using carboxymethyl-${\beta}$-cyclodextrin (CM-${\beta}$-CD) as a chiral selector and high-perfomance liquid chromatography (HPLC) using a chiral stationary phase. In the HPLC method, the separation of bevantolol enantiomers was performed on a Chiralpak AD-H column by isocratic elution with n-hexane-ethanol-diethylamine (10:90:0.1, v/v/v) as mobile phase. In the CE method, bevantolol enantiomers were separated on an uncoated fused silica capillary with 50 mM amonium phosphate dibasic adjusted to a pH 6.5 with phosphoric acid containing 15 mM CM-${\beta}$-CD as running buffer. Validation data such as linearity, recovery, detection limit, and precision of the two methods are presented. The detection limits of S-(-)-bevantolol were 0.1% and 0.05% for CE and HPLC method, respectively and R-(+)-bevantolol were 0.15% and 0.05% for CE and HPLC method, respectively. There was generally good agreement between the HPLC and CE results.