Acceptance Testing and Commissioning of Robotic Intensity-Modulated Radiation Therapy M6 System Equipped with InCiseTM2 Multileaf Collimator

  • Yoon, Jeongmin;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.8-15
    • /
    • 2018
  • This work reports the acceptance testing and commissioning experience of the Robotic Intensity-Modulated Radiation Therapy (IMRT) M6 system with a newly released $InCise^{TM}2$ Multileaf Collimator (MLC) installed at the Yonsei Cancer Center. Acceptance testing included a mechanical interdigitation test, leaf positional accuracy, leakage check, and End-to-End (E2E) tests. Beam data measurements included tissue-phantom ratios (TPRs), off-center ratios (OCRs), output factors collected at 11 field sizes (the smallest field size was $7.6mm{\times}7.7mm$ and largest field size was $115.0mm{\times}100.1mm$ at 800 mm source-to-axis distance), and open beam profiles. The beam model was verified by checking patient-specific quality assurance (QA) in four fiducial-inserted phantoms, using 10 intracranial and extracranial patient plans. All measurements for acceptance testing satisfied manufacturing specifications. Mean leaf position offsets using the Garden Fence test were found to be $0.01{\pm}0.06mm$ and $0.07{\pm}0.05mm$ for X1 and X2 leaf banks, respectively. Maximum and average leaf leakages were 0.20% and 0.18%, respectively. E2E tests for five tracking modes showed 0.26 mm (6D Skull), 0.3 mm (Fiducial), 0.26 mm (Xsight Spine), 0.62 mm (Xsight Lung), and 0.6 mm (Synchrony). TPRs, OCRs, output factors, and open beams measured under various conditions agreed with composite data provided from the manufacturer to within 2%. Patient-specific QA results were evaluated in two ways. Point dose measurements with an ion chamber were all within the 5% absolute-dose agreement, and relative-dose measurements using an array ion chamber detector all satisfied the 3%/3 mm gamma criterion for more than 90% of the measurement points. The Robotic IMRT M6 system equipped with the $InCise^{TM}2$ MLC was proven to be accurate and reliable.

Preliminary Phantom Experiments to Map Amino Acids and Neurotransmitters Using MRI

  • Oh, Jang-Hoon;Kim, Hyug-Gi;Woo, Dong-Cheol;Rhee, Sun Jung;Lee, Soo Yeol;Jahng, Geon-Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.29-41
    • /
    • 2018
  • The objective of this study was to evaluate the chemical exchange saturation transfer (CEST) effect of amino acids and neurotransmitters, which exist in the human brain, depending on the concentration, pH, and amplitude of the saturation radiofrequency field. Phantoms were developed with asparagine (Asn), ${\gamma}-aminobutyric$ acid (GABA), glutamate (Glu), glycine (Gly), and myoinositol (MI). Each chemical had three different concentrations of 10, 30, and 50 mM and three different pH values of 5.6, 6.2, and 7.4. Full Z-spectrum CEST images for each phantom were acquired with a continuous-wave radiofrequency (RF) saturation pulse with two different $B_1$ amplitudes of $2{\mu}T$ and $4{\mu}T$ using an animal 9.4T MRI system. A voxel-based CEST asymmetry was mapped to evaluate exchangeable protons based on amide (-NH), amine ($-NH_2$), and hydroxyl (-OH) groups for the five target molecules. For all target molecules, the CEST effect was increased with increasing concentration and B1 amplitude; however, the CEST effect with varying pH displayed a different trend depending on the characteristics of the molecule. On CEST asymmetric maps, Glu and MI were well visualized around 3.0 and 0.9 ppm, respectively, and were well separated macroscopically at a pH of 7.4. The exchange rates of Asn, Glu, BABA, and Gly usually decreased with increasing pH. The CEST effect was dependent on the concentration, acidity of the target molecules, and B1 amplitude of the saturation RF pulse. The CEST effect for Asn can be observed in a 9.4T MRI system. The results of this study are based on applying the CEST technique in patients with neurodegenerative diseases when proteins in the brain are increased with disease progression.

3차원 프린팅 기술을 이용한 차폐체 제작 및 유용성 평가 (Usefulness Evaluation and Fabrication of the Radiation Shield Using 3D Printing Technology)

  • 장희민;윤준
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.1015-1024
    • /
    • 2019
  • 최근 의료분야에서 X선은 질병의 진단 및 치료영역에서 필수적으로 요구되며, 영상의학 기술의 발전과 더불어 X선의 이용은 지속적으로 증가하는 추세지만, X선은 방사선 피폭의 단점을 가지고 있다. 방사선피폭을 방어하기 위해 임상에서는 납 방호도구를 사용하지만 납은 중금속으로 분류되어 납중독 등 인체에 유해한 반응을 일으킬 수 있다. 따라서 본 연구는 FDM(Fused Deposition Modeling)방식의 3차원 프린터의 재료를 이용하여 제작한 차폐체의 유용성을 알아보고자 한다. 필라멘트의 선감약계수를 확인하기 위해 PLA, XT-CF20, Wood, Glow, Brass를 이용해 팬텀을 제작 하고, CT scan을 하였다. 그리고 100 × 100 × 2 mm 크기의 차폐 시트를 모델링하고, 진단용 X선발생장치와 조사선량계를 이용하여 선량 및 차폐율을 측정하였으며, 납 방호도구와의 차폐율을 비교하였다. 실험결과 Brass의 CT number가 가장 높게 측정되어 Brass를 이용하여 차폐시트를 제작하였으며, 진단용 X선발생장치로 확인한 결과 100 kV, 40 mAs 조건으로 X선 조사 시 6 mm 두께의 차폐시트에서 차폐율이 90 % 이상으로 측정되어 apron 0.25 mmPb보다 차폐율이 높은 것을 확인하였다. 본 연구의 결과 3차원 프린팅 기술로 제작한 차폐체가 진단용 X선 영역에서 높은 차폐율을 보이는 것을 확인하였으며, 납 방호도구와의 비교를 통하여 납을 대체하여 방사선 방호도구로서의 가능성을 알 수 있었다.

간외 담도암 고선량률 관내근접방사선치료 시 몬테카를로 시뮬레이션을 통한 주변장기의 선량평가 연구 (Study of Radiation dose Evaluation using Monte Carlo Simulation while Treating Extrahepatic Bile Duct Cancer with High Dose Rate Intraluminal Brachytherapy)

  • 박주경;이승훈;차석용;이선영
    • 한국콘텐츠학회논문지
    • /
    • 제14권2호
    • /
    • pp.467-474
    • /
    • 2014
  • MCNPX를 통하여 계산한 상대선량과 고체팬텀과 전리함을 이용하여 측정한 상대선량을 비교하여 몬테카를로 시뮬레이션의 정확성을 평가하였다. 그리고 간외 담도암 관내근접방사선치료를 몬테카를로 시뮬레이션에 적용하기 위해 192Ir 밀봉방사성선원을 모사하였고, 한국 성인남성 표준인을 기초로 하는 KMIRD형 팬텀을 이용하여 담도 및 주변 장기를 제작하였다. 간외 담도암 관내근접방사선치료를 MCNPX를 이용하여 담도 주변 정상장기의 비유효에너지와 초기방사능을 1 Ci로 설정하여 흡수선량을 산정하였다. 몬테카를로 시뮬레이션의 정확성 평가에서 상대선량 차이가 가장 많은 지점이 1.96%로 MCNPX에서 제시한 상대오차 2%를 만족하는 것으로 나타났다. 또한, 담도 주변 정상장기의 비유효에너지 및 흡수선량은 담도와비교적 인접한 위치에 있는 우측신장, 간, 췌장, 횡행결장, 척수, 위장, 소장이 높았고, 담도와의 거리가 떨어져 있는 장기들인 좌측신장, 비장, 상행결장, 하행결장, S상결장이 낮게 나타났다.

유방암 검출을 위한 생계 어드미턴스 스캐너의 개발 (Development of Trans-Admittance Scanner (TAS) for Breast Cancer Detection)

  • 이정환;오동인;이재상;우응제;서진근;권오인
    • 대한의용생체공학회:의공학회지
    • /
    • 제25권5호
    • /
    • pp.335-342
    • /
    • 2004
  • 암세포가 정상세포에 비해 전기적 도전율이 세배에서 열배까지 높다는 점을 이용하여 본 논문에서는 유방암 검출을 위한 생체 어드미턴스 스캐너를 개발하고, 시스템의 성능검사를 수행하여 유방암 검출의 가능성을 제시하였다. 전압인가전극을 이용하여 정현파의 정전압을 인가하고 유방의 표면에 부착된 평면배열 접지전극을 통하여 배출되는 전류를 측정한다. 측정된 전류값과 인가한 전압사이의 전달 어드미턴스로부터 측정 부위의 도전율을 표현할 수 있으며, 전달 어드미턴스의 실수부와 허수부의 크기로부터 유방암의 유무와 크기, 위치를 판별하는 데이터를 획득한다. 개발한 생체 어드미턴스 스캐너는 주제어부, 인가전압 발생부, 유기전류 측정부, 전압인가전극 및 평면배열 접지전극과 컴퓨터로 구성된다. 개발한 디지털 인가전방 발생기의 진폭 안정도는 0.2445%의 오차를 가지며, 총 고조파 왜곡은 0.03% 이다. 유기전류 측정부는 실수부의 경우 68dB, 허수부의 경우 54dB이상의 SNR블 가지며, 1nA정도의 작은 전류도 측정이 가능하도록 제작되었다. 저항 펜텀을 이용하여 실험한 결과 측정된 핀달 어드미턴스는 Pspice 시뮬레이션 결과와 비교할 때 93% 이상의 정확도를 나타내었다. 이러한 측정의 정확도를 갖는 생체 어드미턴스 스캐너를 가지고 저항 팬텀 및 전해질용액 펜텀을 이용하여 실험한 결과 도전율이 다른 물체를 식별할 수 있는 전달 어드미턴스 분포 영상을 획득할 수 있음을 확인하였다. 향후 시스템의 성능을 향상시키고, 여러 가지 다른 핀범을 제작하여 이를 정확히 찾아내는지를 실험할 예정이며, 도전율이 다른 물체의 크기, 위치 및 깊이를 찾는 알고리즘을 시스템에 적용하여 알고리즘을 실험적으로 검증하고 유방암의 조기 검진을 위해 활용이 가능한 시스템을 개발하는 연구를 수행할 예정이다.

Advanced Design of Birdcage RF Coil for Various Absorption Regions at 3T MRI System

  • Lee, Jung-Woo;Choe, Bo-Young;Choi, Chi-Bong;Huh, Soon-Nyoung
    • 한국자기공명학회논문지
    • /
    • 제9권1호
    • /
    • pp.48-60
    • /
    • 2005
  • Purpose: The purpose of this study was to design and build an optimized birdcage resonator configuration with a low pass filter, which would facilitate the acquisition of high-resolution 3D-image of small animals at 3T MRI system. Methods and Materials: The birdcage resonator with 12-element structures was built, in order to ensure B1 homogeneity over the image volume and maximum filling factor, and hence to maximize the signal to noise ratio (SNR) and resolution of the 3-dimensional images. The diameter and length of each element of a birdcage resonator were as follows: (1) diameter 13 cm, length 22 cm, (2) diameter 15 cm, length 22 cm, (3) diameter 17 cm, length 25 cm. Spin echo pulse sequence and fast spin echo pulse sequence were employed in obtaining MR images. The quality of the manufactured birdcage resonators wes evaluated on the basis of the return loss following matching and tuning process. Results: The experimental MR image of phantoms by the various manufactured birdcage resonators were obtained to compare the SNR in accordance with the size of objects. The size of an object to that of coil was identified by parameters that were estimated from the image of a phantom. First, the diameter of the birdcage resonator was 15cm, and the ratio of the tangerine to the birdcage resonator accounted for approximately 27%. The Q factor was 53.2 and the SNR was 150.7. Second, at the same birdcage resonator, the ratio of the orange was approximately 53%. The SNR and the Q parameter was 212.8 and 91.2, respectively. Conclusion: The present study demonstrated that if birdcage resonators have the same forms, SNR could be different depending on the size of an object, especially when the size of an object to that of coil is approximately 40~80%, the former is bigger than the latter. Therefore, when the size of an object to be observed is smaller than that of coil, the coil should be manufactured in accordance with the size of an object in order to obtain much more excellent images.

  • PDF

골밀도 측정의 올바른 질 관리방법 (Appropriate image quality management method of bone mineral density measurement)

  • 김호성;동경래
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1141-1149
    • /
    • 2009
  • 골밀도 측정은 정확도와 정밀도가 우수하여야 작은 골량의 변화에도 진정한 생물학적 변화를 알 수 있다. 따라서 장비 및 검사자의 올바른 질 관리를 통하여 골밀도 검사의 신뢰성을 높이는 것을 목적으로 한다. 장비관리방법은 각각의 골밀도 장비 제조사에서 권고하는 팬텀을 이용하여 10~25회 측정하여 기준 값과 허용 범위를 정하고 검사가 있는 날에 매일 측정하거나 일주일에 3회 이상 측정하여 실제 골밀도의 값의 변화 유무를 확인하여야 한다. 또한 측정된 팬텀의 골밀도 수치를 기록하여 Shewart control chart와 CUSUM control chart를 만들어 각각의 Rule에 따라 평가한다. 이러한 관리는 장비의 설치 및 이동 시에 반드시 행해져야 한다. 검사자 관리방법은 정밀도 측정으로 평가하는데 정밀도는 재검사하였을 때에 실제 생물학적의 변화 없이 수치상의 결과값을 똑같이 재현할 수 있는지 알아보는 것이다. 측정 방법은 환자를 두 번씩 30번 측정하는 방법과 세 번씩 15번 측정하는 방법이 있다. 측정에서 중요한 것은 한 번 검사 후 두번째나 세 번째 검사에서도 반드시 검사 테이블에서 내려왔다 다시 올라가서 검사를 해야 한다. 측정된 골밀도 수치를 이용하여 정밀오차를 산출하여 95% 신뢰수준으로 정밀오차에 2.77을 곱하여 최소한의 생물학적 골밀도 변화를 산출한다. 골밀도 장비는 과학의 발달로 인하여 장비의 정확 오차가 1%이내로 줄었기 때문에 장비관리와 측정자의 기계조작 및 검사 오차를 잘 관리한다면 검사의 신뢰성 확보에 도움을 줄 것이다.

  • PDF

Contrast reference values in panoramic radiographic images using an arch-form phantom stand

  • Shin, Jae-Myung;Lee, Chena;Kim, Jo-Eun;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • 제46권3호
    • /
    • pp.203-210
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate appropriate contrast reference values (CRVs) by comparing the contrast in phantom and clinical images. Materials and Methods: Phantom contrast was measured using two methods: (1) counting the number of visible pits of different depths in an aluminum plate, and (2) obtaining the contrast-to-noise ratio (CNR) for 5 tissue-equivalent materials (porcelain, aluminum, polytetrafluoroethylene [PTFE], polyoxymethylene [POM], and polymethylmethacrylate [PMMA]). Four panoramic radiographs of the contrast phantom, embedded in the 4 different regions of the arch-form stand, and 1 real skull phantom image were obtained, post-processed, and compared. The clinical image quality evaluation chart was used to obtain the cut-off values of the phantom CRV corresponding to the criterion of being adequate for diagnosis. Results: The CRVs were obtained using 4 aluminum pits in the incisor and premolar region, 5 aluminum pits in the molar region, and 2 aluminum pits in the temporomandibular joint (TMJ) region. The CRVs obtained based on the CNR measured in the anterior region were: porcelain, 13.95; aluminum, 9.68; PTFE, 6.71; and POM, 1.79. The corresponding values in the premolar region were: porcelain, 14.22; aluminum, 8.82; PTFE, 5.95; and POM, 2.30. In the molar region, the following values were obtained: porcelain, 7.40; aluminum, 3.68; PTFE, 1.27; and POM, - 0.18. The CRVs for the TMJ region were: porcelain, 3.60; aluminum, 2.04; PTFE, 0.48; and POM, - 0.43. Conclusion: CRVs were determined for each part of the jaw using the CNR value and the number of pits observed in phantom images.

말단팬텀에서 X-선 빔의 방향의존성에 관한 이론적 계산 (A Theoretical Calculation for Angular Dependence of X-ray Beams on Extremity Phantom)

  • 김종수;윤석철;김장렬;김광표
    • Journal of Radiation Protection and Research
    • /
    • 제21권4호
    • /
    • pp.263-271
    • /
    • 1996
  • ANSI N13.32에서는 선량제의 방향에 따른 반응도가 성능시험의 합격판정의 범주는 아니지만 이에 관한 연구를 요구하고 있다. 본 연구에서는 ANSI N13.32의 말단팬텀 즉, 손가락과 손목팬텀내의 $7mg/cm^2$ 깊이에서 MCNP 코드를 사용하여 단일에너지를 가진 광자 및 ISO narrow X-선 빔에 대하여 선량당량환산인자와 방향의존성인자를 도출하였다. X-선 빔에 대하여는 이들 데이터를 B. Grosswent의 연구 결과와 비교하였다. 그 결과 선량당량환산인자는 낮은 에너지 영역에서 최대 7%를 그리고 다른 에너지 영역에서는 2% 이내였으며, 방향의존성인자는 최대 3% 정도로 잘 일치하였다. 또한 60keV 이하의 낮은 에너지 영역에서 발생된 방향의존성인자는 손가락 팬텀의 경우에 주축을 따라 수평회전각이 증가할수록 감소하지만 그 에너지 영역 이상에서 $90^{\circ}$까지는 증가하고 있음을 알 수 있었다.

  • PDF

적응 대역필터를 이용한 의료 초음파 감쇠 예측 (Estimation of Medical Ultrasound Attenuation using Adaptive Bandpass Filters)

  • 허서원;이준환;김형석
    • 전자공학회논문지SC
    • /
    • 제47권5호
    • /
    • pp.43-51
    • /
    • 2010
  • 의료 초음파 신호의 인체내 감쇠지수는 검사대상 조직의 병리학적 특성을 반영할 뿐 아니라 다른 여러 의료 초음파 지수들의 정확한 예측을 위해 선행하여 측정해야 하는 중요한 정량적 정보 중 하나이다. 그러나 초음파 감쇠지수의 주파수 선택적 감쇠특성을 이용한 주파수 영역에서의 정량적 감쇠지수 예측 방법은 계산량이 많아 실시간 적용에 많은 어려움이 있고, 상대적으로 계산량이 적은 시간 영역의 감쇠지수 예측 방법은 전송 펄스의 회절효과를 잘 보상하지 못하는 단점이 있다. 표준 반향신호를 이용하여 전송 펄스의 회절효과를 보상하는 시간 영역의 예측 알고리듬인 VSA(Video Signal Analysis) 방법은 광대역 펄스를 이용하는 경우, 원거리에서 반향된 신호의 왜곡이 발생하여 예측 정확도가 저하되는 단점이 있다. 본 논문에서는 그 단점을 해결하기 위해 적응 대역필터를 이용한 초음파 감쇠지수 예측 알고리듬을 제안한다. 제안된 방식은 반향 경로를 따라 누적된 신호 감쇠를 고려하여 적응 대역필터의 중심 주파수를 이동시킴으로써, 기존의 고정 대역필터를 사용하는 방법보다 예측 정확도와 정밀도를 높인다. 인체 조직의 초음파 반향특성을 모방한 컴퓨터 모의실험과 실제 TM(tissue-mimicking) phantom을 이용한 실험에서, 광대역 전송 펄스를 사용하는 경우보다 반향 깊이에 따른 상대적 echogenicity의 왜곡이 크게 감소하여 평균적으로 예측 감쇠지수의 정확도가 5.1% 향상되었고, 예측 편차도 기존의 방법에 비해 46.9% 감소되었다.