• Title/Summary/Keyword: Phantom sound

Search Result 26, Processing Time 0.021 seconds

Analysis of Vibration and Its Break Efficiency Due to Focal Position Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter (압전식 ESWL장치를 사용한 대상물 진동시 초점위치에 따른 진동 및 파쇄효율의 분석)

  • 장윤석
    • Proceedings of the IEEK Conference
    • /
    • 2000.06d
    • /
    • pp.186-189
    • /
    • 2000
  • In this paper, the relation between the vibration and the sound radiated due to the piezoelectric ESWL (Extra-corporeal Shock Wave Lithotripter) is examined And the relation between the focus and the vibration of the objects is examined. The same experiments with the objects that can be breton are done and the relation between the vibration and the break efficiency of the phantom is experimentally investigated. These results show that the relativity between the power of the peak frequency and the break efficiency can be confirmed.

  • PDF

The Relativity between Vibration of Phantom and Its Break Efficiency Due to Position of Focus Induced by Piezoelectric Extracorporeal Shock Wave Lithotripter (압전식 충격파 체외 쇄석기 사용시 초점위치에 의한 대상물의 진동과 파쇄효율과의 상관성)

  • 장윤석
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.5
    • /
    • pp.35-40
    • /
    • 2000
  • In this paper, the relation between the radiated sound and the vibration due to piezoelectric ESWL(Extracorporeal Shock Wave Lithotripter) is examined and the results of the experiments are represented. Next, the relation between the focal point and the vibration of the objects is examined. The same experiments with the objects that can be broken are done and the relation between the vibration and the break efficiency of the phantom is experimentally investigated. These results show that the relativity between the power of the peak frequency and the break efficiency can be confirmed.

  • PDF

Vibration Analysis During Breaking Process of Phantom Induced by Shock Wave for Medical Treatment (의료용 충격파에 의할 대상물의 파쇄진행에 따른 진동해석)

  • Park Kyu-Chil;Jang Yun-Seok
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2006
  • When the vibration of a phantom induced by Extracorporeal Shock Wave Lithotripter (ESWL) was investigated. we found the fact that the Peak frequency in the Power spectrum shifts from high frequency to low frequency as the number of shots increases[2]. The fact was confirmed experimentally by detecting the peak frequency obtained from the vibrations of bronze models[3]. This Paper investigates the experimental results. For the Purpose. we carried out the computer simulation using the finite element method. It is found that the results from the experiments are computer by computer simulation.

Haptic and Sound Grid for Enhanced Positioning in 3-D Virtual Environment (햅틱 / 사운드 그리드를 이용한 3차원 가상 환경 내의 위치 정보 인식 향상)

  • Kim, Seung-Chan;Yang, Tae-Heon;Kwon, Dong-Soo
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.447-454
    • /
    • 2007
  • 본 논문에서는 사용자의 가상환경 내의 위치 정보에 대한 감각을 향상시키는 방법론으로서 햅틱 피드백(haptic feedback)과 사운드 피드백(sound feedback)의 모달리티를 활용한 그리드(grid)를 제안한다. 제안된 그리드는 사용자의 3차원 공간 내의 움직임(explorative procedure)에 추가적인 비 시각적인(non-visual) 위치정보 피드백을 부여하는데 그 목적을 두고 있다. 햅틱 모달리티를 활용한 3차원 그리드는 SensAble사의 PHANTOM(R) Omni$^{TM}$ 를 활용하여 설계되었으며, 사운드 모달리티를 활용한 경우 저주파 배경음의 주파수 특성(frequency characteristics of sound source)을 사용자 손의 공간 좌표값에 근거하여 재생 시의 표본 추출 비율(sampling rate)를 연속적으로 바꾸는 방식으로 설계되었다. 이러한 공간 그리드는 두 모달리티 각각의 독립적인 제시 및 동시 제시/제거를 통해 평가되었으며, 동시 제시의 경우 두 모달리티간의 어긋남(cross-modal asynchrony)이 없도록 설계되어 사용자의 공간 작업 시 모달리티간의 조화 (manipulating congruency)를 확보할 수 있도록 하였다. 실험을 통해 얻어진 결과는 그것의 통계적 유의미성을 분석하기 위해 다원변량분석과 사후검증(Turkey. HSD)을 거쳐 해석이 되었다. 공간 내 특정 좌표 선택을 기준으로 하는 그리드의 사용자 평과 결과, 3차원 내의 움직임에 대해 햅틱 및 사운드 피드백의 비 시각적 피드백은 사용자의 공간 작업의 오차를 줄여 주고 있음이 확인되었다. 특히 시각적인 정보만으로 확인하기 어려운 Z축 상의 움직임은 그리드의 도움으로 그 오차정도가 50% 이상 줄어 드는 것으로 확인되었다(F=19.82, p<0.01). 이러한 시각적 정보를 보존하는 햅틱, 사운드 피드백 방식을 HCI의 중요한 요소인 사용성과 유용성과 연관시켜 MMHCI(multimodal human-computer interaction) 방법론으로의 적용 가능성을 검토해 본다.

  • PDF

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

Estimation of Unknown Projection DATA Based on the Bandwidth of Projection DATA

  • Kil-Houm Park
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.275-280
    • /
    • 1994
  • In the case of the image reconstruction from unknown projection data such as imaging the object with opaque obstructions, conventional reconstruction algorithms may reconstruct a degraded image. In this paper, a new method for the estimation of the unknown projection data based on known projection data and the bandwidth of projection data is proposed. The proposed method successfully estimates the unknown projection data through iterative transformation between projection space and frequency space using the known projection data and the bandwidth of the projection data. Computer simulation shows that the proposed method significantly improves image quality and convergence behavior over conventional algorithms. In addition, the proposed method is successfully applied to ultrasound attenuation CT using a sponge phantom.

  • PDF

Non-Invasive Neuromodulation for Tinnitus

  • Langguth, Berthold
    • Korean Journal of Audiology
    • /
    • v.24 no.3
    • /
    • pp.113-118
    • /
    • 2020
  • Tinnitus is a prevalent disorder that has no cure currently. Within the last two decades, neuroscientific research has facilitated a better understanding of the pathophysiological mechanisms that underlie the generation and maintenance of tinnitus, and the brain and nerves have been identified as potential targets for its treatment using non-invasive brain stimulation methods. This article reviews studies on tinnitus patients using transcranial magnetic stimulation, transcranial electrical stimulation, such as transcranial direct current stimulation, alternating current stimulation, transcranial random noise stimulation as well as transcutaneous vagus nerve stimulation and bimodal combined auditory and somatosensory stimulation. Although none of these approaches has demonstrated effects that would justify its use in routine treatment, the studies have provided important insights into tinnitus pathophysiology. Moreover bimodal stimulation, which has only been developed recently, has shown promising results in pilot trials and is a candidate for further development into a valuable treatment procedure.

Non-Invasive Neuromodulation for Tinnitus

  • Langguth, Berthold
    • Journal of Audiology & Otology
    • /
    • v.24 no.3
    • /
    • pp.113-118
    • /
    • 2020
  • Tinnitus is a prevalent disorder that has no cure currently. Within the last two decades, neuroscientific research has facilitated a better understanding of the pathophysiological mechanisms that underlie the generation and maintenance of tinnitus, and the brain and nerves have been identified as potential targets for its treatment using non-invasive brain stimulation methods. This article reviews studies on tinnitus patients using transcranial magnetic stimulation, transcranial electrical stimulation, such as transcranial direct current stimulation, alternating current stimulation, transcranial random noise stimulation as well as transcutaneous vagus nerve stimulation and bimodal combined auditory and somatosensory stimulation. Although none of these approaches has demonstrated effects that would justify its use in routine treatment, the studies have provided important insights into tinnitus pathophysiology. Moreover bimodal stimulation, which has only been developed recently, has shown promising results in pilot trials and is a candidate for further development into a valuable treatment procedure.

Development of Photoacoustic System for Breast Cancer Detection (유방암 진단용 광음향 영상 시스템 개발)

  • Lee, Soonhyouk;Ji, Yun-Seo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.183-190
    • /
    • 2013
  • Recently, the photoacoustic imaging system has been widely and intensively developed, and has been shown the possibility of diagnosis for early stage cancer. In this study, we developed a photoacoustic tomography imaging system with a commercial ultra sound device and a linear array probe. A tube phantom and a chicken breast phantom was made for the possibility of a system as a breast cancer detection. A moving average filter and a band pass filter with 3~6 MHz bandwidth were developed for background noise elimination before delay-and-sum beamforming algorithm was used for image reconstruction. As a result, we showed that some signal processing procedure before beamforming was effective for the photoacoustic image reconstruction.

Micro Vibration Measurement in a Latex Sample Mimicking the Tympanic Membrane Using Micro Vibro Tomography (고막을 모방한 라텍스 샘플의 미세진동 측정을 위한 마이크로 바이브로 토모그라피 시스템 개발)

  • Kwon, Jaehwan;Kim, Pilun;Jeon, Mansik;Kim, Jeehyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.23-27
    • /
    • 2019
  • In this paper, we propose a micro vibro tomography(MVT) method, that can be used to visualize two-dimensional cross-sectional images and micro-vibration tomographic images in real time in a non-contact and non-destructive manner. The proposed method is based on the optical coherence tomography(OCT) technique, with an additionally customized image processing algorithm. The proposed method can detect the micro-motions or vibrations in sample structures by measuring the phase shift variations in the sample structures. In this study, we show the potential capabilities of the proposed MVT system for measuring the micro-vibrations generated when sound waves in a frequency range of 2~5 kHz are applied to an $80-{\mu}m$ thick latex phantom, which mimics the changes in physical structure of the human tympanic membrane while hearing. Additionally, three-dimensional volumetric images of the MVT method were recorded to observe the surface morphological changes in the surface of the phantom sample which mimics the human tympanic membrane while hearing.