• Title/Summary/Keyword: Petrochemical process

Search Result 155, Processing Time 0.024 seconds

Applicability of the lenten's Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant (석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성)

  • Lee, Kyu-Hoon;Kim, Mi-Hwa;Park, Tae-Joo
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.115-115
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton''s reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

Applicability of the lenten류s Reagent Oxidation to Biological Fixed-Film Process for Reuse of Effluents from the Petrochemical Wastewster Effluent Treatment Plant (석유화학폐수 처리장 방류수의 재이용을 위한 고정생물막 공정에서 Fenton 산화전처리의 적응가능성)

  • Lee, Kyu-Hoon;Kim, Mi-Hwa;Park, Tae-Joo
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.501-508
    • /
    • 1995
  • Reuse of industrial effluents through the cooling systems in a petrochemical complex was described. The partial oxidation of the effluents from the biological treatment plant was examined, using Fenton's reagent as a pretreatment step prior to a next treatment of the effluents. Next tertiary treatment using fixed-film reactor resulted in marked reductions in COD and suspended solids. The continuous fixed-film process with Fenton oxidation pretreatment showed a 23% increase in the COD removal efficiency when compared to that without pretreatment of Fenton oxidation under the volumetric organic loading rate of 0.1 kg COD/m3/day. The Fenton oxidation treatment seemed to be a possible method for tertiary biological treatment to reduce the residual toxicity with the enhanced biodegradation of the effluents.

  • PDF

Analysis of Safety of the Chemical Facilities by Korea Risk Based-Inspection in the Petrochemical Plant (석유화학공장에서의 한국형 위험기반검사에 의한 화학설비의 안정성 평가)

  • Kim, Tae-Ok;Lee, Hern-Chang;Shin, Pyng-Sik;Choi, Byung-Nam;Jo, Ji-Hoon;Choi, Byung-Young;Park, Sung-Hoo;Kim, Hung-Kun
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.6
    • /
    • pp.35-40
    • /
    • 2007
  • As a way of improving the safety of the chemical facilities, the risk based-inspection(RBI) was executed for the facilities of the applied petrochemical plant using KS-RBI Ver. 3.0 program developed based on the API-581 based resource document(BRD). From an evaluation result of KS-RBI program, we could find the evaluation of the process safety management(PSM) for the applied plant, risk of the applied process, risk of static facilities and pipes, and the demage mechanism of the facilities. Also, we could suggest a proper inspection plan(frequency and method of inspection) using the calculated risk and the status of the facilities. Therefore, the applied plant could be achieved a reduced inspection cost by an extension of inspection frequency, improved productivity, improved reliability of the facilities, and a computerized history management.

생분해성 고분자 합성을 위한 락티드 합성에서 열분해 공정의 개선

  • No, Won-Gyun;Ryu, Hwa-Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2003.04a
    • /
    • pp.622-624
    • /
    • 2003
  • Poly(lactic acid) is a biodegradable themoplastic based on the renewable resources to substitute for petrochemical plastics. Most of PLA is produced by ring opening polymerization from lactide. However, pyrolysis process in the lactide synthesis is expensive, we studied lactide synthetic process for more economical preparation of PLA. In this research was tried to minimize the pyrolysis time, and obtained L-lactide from lactic acid without any catalyst.

  • PDF

A study on reduction of excess sludge in activated sludge system from a petrochemical plant using electro fenton process (전기펜톤공정을 이용한 석유화학공장 폐활성슬러지의 감량화 가능성 평가)

  • Chung, Chong Min;Kim, Kyung Il;Shim, Natalia;Park, Chul Hee;Lee, Sang Hyup
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.669-678
    • /
    • 2009
  • The reduction of excess activated sludge from petrochemical plant was investigated by the electro fenton (E-Fenton) process using electrogenerated hydroxyl radicals which lead to mineralization of activated sludge to $CO_2$, water and inorganic ions. Factors affecting the disintegration efficiency of excess activated sludge in E-Fenton process were examined in terms of five criteria: pH, $H_2O_2/Fe^{2+}$ molar ratio, current density, initial MLSS (mixed liquid suspended solids) concentration, $H_2O_2$ feeding mode. TSS total suspended solid and $TCOD_{cr}$ reduction rate increased with the increasing $H_2O_2/Fe^{2+}$ molar ratio and current density until 42 and $6.7 mA/cm^2$, respectively but further increase of $H_2O_2/Fe^{2+}$ molar ratio and current density would reduce the reduction rate. On the other hand, as expected, increasing pH and initial MLSS concentration of activated sludge decreas TSS and $TCOD_{cr}$ reduction rate. The E-Fenton process was gradually increased during first 30 minutes and then linearly proceed till 120 minutes. The optimal E-Fenton condition showed TSS reduction rate of 62~63% and $TCOD_{cr}$ (total chemical oxygen demand) reduction rate of 55~56%. Molar ratio $H_2O_2/Fe^{2+} = 42$ was determined as optimal E-Fenton condition with initial $Fe^{2+}$ dose of 5.4 mM and current density of $6.7{\sim}13.3 mA/cm^2$, initial MLSS of 7,600 mg/L and pH 2 were chosen as the most efficient E-Fenton condition.

Application of Risk Based-Inspection for the Safety Improvement of the Chemical Facilities (화학설비의 안전성 향상을 위한 위험기반검사의 적용)

  • Kim Tae-Ok;Lu Hern-Chang;Shin Pyong-Sik;Choi Byung-Nam;Jo Ji-Hoon;Jeong Seong-Gweong;Ki O-Hwan;Shin Dong-Il
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.3 s.32
    • /
    • pp.13-19
    • /
    • 2006
  • As a way of improving the safety of the facilities, the risk based-inspection (RBI) was executed for the chemical facilities by using K-RBI program, which has been developed based on the API-581 based resource document (BRD). As the result of the evaluation, we found the level of the process safety management (PSM) for the applied plant, quantitative risk of the applied process, risk of static facilities and pipes, and the damage mechanism of the facilities. Thus, we could suggest a proper inspection frequency using the calculated risk of the process and the status of the facilities. The applied plant achieved a reduced inspection cost by an extension of the inspection frequency, improved productivity, improved reliability of the facilities, and a computerized history management.

  • PDF

The Application of Non-phosphorous AEC Program in Cooling Water Systems of Petrochemical Industry

  • Li, Dagang;Hong, Mike;He, Gaorong
    • Corrosion Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.16-21
    • /
    • 2008
  • A non-phosphorous program employing an alkyl epoxy carboxylate (AEC) has been successfully applied to petrochemical and other large industrial open recirculating cooling water systems. AEC is a patented non-phosphorous calcium carbonate scale inhibitor that has demonstrated better scale inhibition abilities than traditional organic phosphonates. In addition to its antiscalant properties, AEC inhibits carbon steel corrosion when used at high dosages. AEC can be combined with zinc to form a non-phosphorous program with very low levels of phosphate to provide an environmentally acceptable program. In actual applications, the total phosphate developed in the cooling system from cycling the makeup is below 1 ppm as $PO_4$. This level has complied with the highest standards of wastewater discharge limitations. The performance of two AEC/Zinc applications is reviewed. In both cases excellent corrosion and scale control were achieved with AEC/Zinc programs. One case history details the performance with a low hardness water (100 ppm calcium, as $CaCO_3$) operating at 8-10 cycles of concentration. The corrosive nature of the water and the long retention time of the system stressed both the corrosion and scale control capabilities of the program. The second case history demonstrates the performance of the program with a moderate hardness water (400-600 ppm calcium, as $CaCO_3$), but under harsh conditions of high temperature and low flow. The AEC/zinc combination has been found to be highly effective in controlling the corrosion of ferrous metals. AEC can provide good corrosion inhibition at high concentrations, while zinc is known to be an excellent cathodic inhibitor. The combination of the two inhibitors not only provides a synergistic blend that is effective over a wide range of operating conditions, but also is environmentally friendly.

A STUDY ON INDUSTRIAL GAMMA RAY CT WITH A SINGLE SOURCE-DETECTOR PAIR

  • Kim Jong-Bum;Jung Sung-Hee;Kim Jin-Sup
    • Nuclear Engineering and Technology
    • /
    • v.38 no.4
    • /
    • pp.383-390
    • /
    • 2006
  • Having its roots in medical applications, industrial gamma ray CT has opened up new roads far investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch $\times$ 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant.

Robust Polymeric Membranes for the Separation of Petrochemicals using Pervaporation

  • Nam, Sang-Yong
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.51-54
    • /
    • 2004
  • Utilization of membranes offers the promise of extraordinary energy savings if successfully applied to hydrocarbon-hydrocarbon and other organic separations. Membranes are bound to enter into refining and petrochemical operations involving liquid separations once appropriate materials and modules are developed. Hybrid processes such as utilizing membrane modules to break azeotropes formed during distillation are particularly attractive because they offer less process complexity and reduced capital investment[1,2].(omitted)

  • PDF

Rapid Compositional Analysis of Naphtha by Near-Infrared Spectroscopy

  • 구민식;정호일;이준식
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.11
    • /
    • pp.1189-1193
    • /
    • 1998
  • The determination of total paraffin, naphthene, and aromatic (PNA) contents in naphtha samples, which were directly obtained from actual refining process, has been studied using near-infrared (NIR) spectroscopy. Each of the total PNA concentrations in naphtha has been successfully analyzed using NIR spectroscopy. Partial least squares (PLS) regression method has been utilized to quantify the total PNA contents in naphtha from the NIR spectral bands. The NIR calibration results showed an excellent correlation with those of conventional gas chromatography (GC). Due to its rapidity and accuracy, NIR spectroscopy is appeared as a new analytical technique which can be substituted for the conventional GC method for the quantitative analysis of petrochemical products including naphtha.