검색결과 395건 처리시간 0.03초

자기 지도 학습훈련 기반의 Noise2Void 네트워크를 이용한 PET 영상의 잡음 제거 평가: 팬텀 실험 (The Evaluation of Denoising PET Image Using Self Supervised Noise2Void Learning Training: A Phantom Study)

  • 윤석환;박찬록
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권6호
    • /
    • pp.655-661
    • /
    • 2021
  • Positron emission tomography (PET) images is affected by acquisition time, short acquisition times results in low gamma counts leading to degradation of image quality by statistical noise. Noise2Void(N2V) is self supervised denoising model that is convolutional neural network (CNN) based deep learning. The purpose of this study is to evaluate denoising performance of N2V for PET image with a short acquisition time. The phantom was scanned as a list mode for 10 min using Biograph mCT40 of PET/CT (Siemens Healthcare, Erlangen, Germany). We compared PET images using NEMA image-quality phantom for standard acquisition time (10 min), short acquisition time (2min) and simulated PET image (S2 min). To evaluate performance of N2V, the peak signal to noise ratio (PSNR), normalized root mean square error (NRMSE), structural similarity index (SSIM) and radio-activity recovery coefficient (RC) were used. The PSNR, NRMSE and SSIM for 2 min and S2 min PET images compared to 10min PET image were 30.983, 33.936, 9.954, 7.609 and 0.916, 0.934 respectively. The RC for spheres with S2 min PET image also met European Association of Nuclear Medicine Research Ltd. (EARL) FDG PET accreditation program. We confirmed generated S2 min PET image from N2V deep learning showed improvement results compared to 2 min PET image and The PET images on visual analysis were also comparable between 10 min and S2 min PET images. In conclusion, noisy PET image by means of short acquisition time using N2V denoising network model can be improved image quality without underestimation of radioactivity.

13N-ammonia 심장 PET 검사에서 ECG gated scan의 유용성 평가 (Evaluation about a Usefulness of ECG-Gated Scan on 13N-ammonia PET)

  • 김재일;이홍재;김진의
    • 핵의학기술
    • /
    • 제20권1호
    • /
    • pp.20-23
    • /
    • 2016
  • 심장 질환에 의한 사망률의 점차적으로 증가하므로 heart PET 검사가 많이 활용되고 있다. 하지만 static mode의 경우 심장 움직임으로 인해 흐림이 많이 발생하므로 심전도와 동기화 검사를 통해 보다 공간 분해능을 향상 시킬 수 있을 겁니다. 5명의 내원 환자에 대해 10 mCi의 $^{13}N-ammonia$를 주입하면서 ECG와 gate 한 list mode 획득하고, non-gate영상과 gated 영상을 재구성 후, 비교 평가하였다. 반치폭은 23.34% 증가하였고, 두 영상간의 감쇠 영상은 많은 차이가 남을 알 수 있었으며, 눈가림 실험에서도 8명 모두가 gated PET 영상이 우수함을 말해 주었다. 심전도와 동기화를 통해 심장 PET 영상의 공간 분해능이 우수해졌으며, EF value, wall motion, QPS, QGS와 같이 다양한 정량적 평가에 시행할 수 있어서, 보다 많은 정보를 환자에 제공해줌을 알 수 있었다.

  • PDF

Comparison of PET image quality using simultaneous PET/MR by attenuation correction with various MR pulse sequences

  • Park, Chan Rok;Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1610-1615
    • /
    • 2019
  • Positron emission tomography (PET)/magnetic resonance (MR) scanning has the advantage of less additional exposure to radiation than does PET/computed tomography (CT). In particular, MR based attenuation correction (MR AC) can greatly affect the image quality of PET and is frequently obtained using various MR sequences. Thus, the purpose of the current study was to quantitatively compare the image quality between MR non-AC (MR NAC) and MR AC in PET images with three MR sequences. Percent image uniformity (PIU), percent contrast recovery (PCR), and percent background variability (PBV) were estimated to evaluate the quality of PET images with MR AC. Based on the results of PIU, 15.2% increase in the average quality was observed for PET images with MR AC than for PET images with MR NAC. In addition, 28.6% and 71.1% improvement in the average results of PCR and PBV respectively, was observed for PET images with MR AC compared with that with MR NAC. Moreover, no significant difference was observed among the average values using three MR sequences. In conclusion, the current study demonstrated that PET with MR AC improved the image quality and can be help diagnosis in all MR sequence cases.

동시 PET-MRI를 위한 N-(p-maleimidophenyl) isocyanate linker-매개 합성을 이용한 복합 조영제의 평가 (Evaluation of Combined Contrast Agent using N-(p-maleimidophenyl) Isocyanate Linker-mediated Synthesis for Simultaneous PET-MRI)

  • 이길재;이훈재;이태수
    • 한국방사선학회논문지
    • /
    • 제16권2호
    • /
    • pp.103-113
    • /
    • 2022
  • 이 논문에서는 결합된 PET(fluorodeoxyglucose, 18F-FDG)와 MRI(magnetic nanoparticles, MNP) 조영제를 동시 PET-MRI 스캔에 사용하기 위한 가교제로 N-(p-maleimidophenyl) isocyanate를 사용하여 합성하는 방안을 제안하였다. 실험은 신경교종 줄기 세포 마우스 모델에서 결합 조영제(18F-FDG로 표지된 MNP)를 주입하기 전후에 PET-MRI 이미지를 획득하고 평가하였다. 획득한 각 영상에 대해 관심영역(ROI)을 설정한 후, 분할하여 병변의 면적을 계산하였을 때 PET 영상이 MRI 영상보다 더 크고 정확했다. 특히 동시 PET-MRI 영상은 주변 연조직과 함께 정확한 병변을 묘사하였다. 평균 및 표준편차 값은 조영제 주입 여부에 관계없이 PET 영상 또는 PET-MRI 동시 영상보다 MRI 단독 영상에서 더 높게 나타났다. 또한 동시 PET-MRI 영상값이 PET 영상보다 평균 및 표준편차 값이 높게 나타났다. 18F-FDG 라벨링된 MNP 조영제와 동시 PET-MRI 영상을 표적 영상으로 사용하고 18F- FDG 조영제만을 원본 이미지로 사용했을 때의 피크 신호 대 잡음비(PSNR) 값은 모든 실험에서 유의미 하게 나타났다. 결론적으로 동시 PET-MRI 영상에서 결합된 18F-FDG 표지 MNP 조영제가 유용함을 확인하였다. 다양한 핵종을 사용할 수 있는 SPECT-MRI 영상 연구를 통해 진단과 치료를 동시에 할 수 있는 제제를 개발하기 위해서는 향후 연구가 필요할 것이다.

PET/CT에서 Phantom을 이용한 Fluorine-18, Gallium-68 방사성 핵종의 PET 영상 평가 (Evaluation of PET Image for Fluorine-18 and Gallium-68 using Phantom in PET/CT)

  • 윤석환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권4호
    • /
    • pp.321-327
    • /
    • 2018
  • The purpose of this study is to compare PET imaging performance with Fluorine-18 ($^{18}F$) and Gallium-68 ($^{68}Ga$) for influence of physical properties of PET tracer. Measurement were performed on a Siemens Biograph mCT64 PET/CT scanner using NEMA IEC body phantom and Flangeless Esser PET phantom containing filled with $^{18}F$ and $^{68}Ga$. Emission scan duration(ESD) was set to 1, 2, 3, 4 and 5min/bed for $^{68}Ga$ and 1min/bed for $^{18}F$. The PET image were evaluated in terms of contrast, spatial resolution. Under same condition, The percentage of contrast recovery measured in the phantom ranged from 16.88% to 72.56% for $^{68}Ga$ and from 27.51% to 74.43% for $^{18}F$ and The FWHM value to evaluate spatial resolution was 10.96 mm for $^{68}Ga$ and 9.19 mm for $^{18}F$. For this study, $^{18}F$ produces better image contrast and spatial resolution than $^{68}Ga$ due to higher positron yield and lower positron energy ($^{18}F$: 96.86%, 633.5 keV, $^{68}Ga$: 88.9%, 1899 keV), The physical properties of PET tracer effect on the PET image. $^{68}Ga$ image applying ESD of 3, 4, 5min/bed were showed similar to $^{18}F$ image with ESD of 1min/bed. This study suggests that increasing ESD for acquiring $^{68}Ga$ PET image seem to be similar to $^{18}F$ image.

PET/CT 영상 움직임 보정 (Motion Correction in PET/CT Images)

  • 우상근;천기정
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제42권2호
    • /
    • pp.172-180
    • /
    • 2008
  • PET/CT fused image with anatomical and functional information have improved medical diagnosis and interpretation. This fusion has resulted in more precise localization and characterization of sites of radio-tracer uptake. However, a motion during whole-body imaging has been recognized as a source of image quality degradation and reduced the quantitative accuracy of PET/CT study. The respiratory motion problem is more challenging in combined PET/CT imaging. In combined PET/CT, CT is used to localize tumors and to correct for attenuation in the PET images. An accurate spatial registration of PET and CT image sets is a prerequisite for accurate diagnosis and SUV measurement. Correcting for the spatial mismatch caused by motion represents a particular challenge for the requisite registration accuracy as a result of differences in PET/CT image. This paper provides a brief summary of the materials and methods involved in multiple investigations of the correction for respiratory motion in PET/CT imaging, with the goal of improving image quality and quantitative accuracy.

MR-based Partial Volume Correction for $^{18}$F-PET Data Using Hoffman Brain Phantom

  • Kim, D. H.;Kim, H. J.;H. K. Jeong;H. K. Son;W. S. Kang;H. Jung;S. I. Hong;M. Yun;Lee, J. D.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.322-323
    • /
    • 2002
  • Partial volume averaging effect of PET data influences on the accuracy of quantitative measurements of regional brain metabolism because spatial resolution of PET is limited. The purpose of this study was to evaluate the accuracy of partial volume correction carried out on $^{18}$ F-PET images using Hoffman brain phantom. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices of the same phantom. All the MR slices of the phantom were then segmented to be binary images. Each of these binary images was convolved in 2 dimensions with the spatial resolution of the PET. The original PET images were then divided by the smoothed binary images in slice-by-slice, voxel-by-voxel basis resulting in larger PET image volume in size. This enlarged partial volume corrected PET image volume was multiplied by original binary image volume to exclude extracortical region. The evaluation of partial volume corrected PET image volume was performed by region of interests (ROI) analysis applying ROIs, which were drawn on cortical regions of the original MR image slices, to corrected and original PET image volume. From the ROI analysis, range of regional mean values increases of partial volume corrected PET images was 4 to 14%, and average increase for all the ROIs was about 10% in this phantom study. Hoffman brain phantom study was useful for the objective evaluation of the partial volume correction method. This MR-based correction method would be applicable to patients in the. quantitative analysis of FDG-PET studies.

  • PDF

18F-FDG PET 지연영상 생성에 대한 딥러닝 이미지 생성 방법론 비교 (Comparison of Paired and Unpaired Image-to-image Translation for 18F-FDG Delayed PET Generation)

  • 알마슬라마니 모아스;김강산;변병현;우상근
    • 한국컴퓨터정보학회:학술대회논문집
    • /
    • 한국컴퓨터정보학회 2023년도 제68차 하계학술대회논문집 31권2호
    • /
    • pp.179-181
    • /
    • 2023
  • 본 논문에서는 GAN 기반의 영상 생성 방법론을 이용해 delayed PET 영상을 생성하는 연구를 수행하였다. PET은 양전자를 방출하는 방사성 동위원소를 표지한 방사성의약품의 체내 분포를 시각화함으로서 암 세포 진단에 이용되는 의료영상 기법이다. 하지만 PET의 스캔 과정에서 방사성의약품이 체내에 분포하는 데에 걸리는 시간이 오래 걸린다는 문제점이 존재한다. 따라서 본 연구에서는 방사성의약품이 충분히 분포되지 않은 상태에서 얻은 PET 영상을 통해 목표로 하는 충분히 시간이 지난 후에 얻은 PET 영상을 생성하는 모델을 GAN (generative adversarial network)에 기반한 image-to-image translation(I2I)를 통해 수행했다. 특히, 생성 전후의 영상 간의 영상 쌍을 고려한 paired I2I인 Pix2pix와 이를 고려하지 않은 unpaired I2I인 CycleGAN 두 가지의 방법론을 비교하였다. 연구 결과, Pix2pix에 기반해 생성한 delayed PET 영상이 CycleGAN을 통해 생성한 영상에 비해 영상 품질이 좋음을 확인했으며, 또한 실제 획득한 ground-truth delayed PET 영상과의 유사도 또한 더 높음을 확인할 수 있었다. 결과적으로, 딥러닝에 기반해 early PET을 통해 delayed PET을 생성할 수 있었으며, paired I2I를 적용할 경우 보다 높은 성능을 기대할 수 있었다. 이를 통해 PET 영상 획득 과정에서 방사성의약품의 체내 분포에 소요되는 시간을 딥러닝 모델을 통해 줄여 PET 이미징 과정의 시간적 비용을 절감하는 데에 크게 기여할 수 있을 것으로 기대된다.

  • PDF

PET-CT 융합 영상에서 치과보철물의 금속 종류에 따른 표준섭취계수 값의 변화 (Changes in the Standardized Uptake Value According to the Type of Metal of Dental Prosthesis in PET-CT Fusion Image)

  • 한상현
    • 한국융합학회논문지
    • /
    • 제9권9호
    • /
    • pp.117-122
    • /
    • 2018
  • 본 연구는 PET-CT 검사를 시행할 때 치과보철물에 의해 발생되는 CT의 HU(Hounsfield Unit) 값을 금속의 종류에 따라 측정하고, PET 영상의 왜곡정도와 표준섭취계수(SUV)의 변화를 확인하여 영상 판독 시 오류의 감소방안을 제시하고자 하였다. 실험방법은 실제 치아와 메탈 크라운, 골드크라운, 티타늄, 지르코니아의 치과보철물을 이용하여 PET-CT 검사를 실시하였다. 일반 치아와 비교한 결과 HU 값이 증가함에 따라 SUV 값이 증가되는 것을 확인하였고, 메탈 크라운, 티타늄, 지르코니아의 SUV 값은 37% 정도 증가되었고, 골드 크라운에서는 45.4%로 가장 많이 증가했다. 그리고 일반치아, 메탈크라운, 티타늄, 지르코니아에서 영상 왜곡은 미미했지만, 골드 크라운에서는 선속경화현상이 심하게 발생하였고, 영상 왜곡이 나타났다. 따라서 치과보철물의 금속종류는 SUV 값에 영향을 미치기 때문에 치과 보철물 중에서 골드 재질을 사용한 환자를 진단할 때에는 영상 판독 시 보정된 PET 영상보다는 NAC(무보정) PET 영상을 확인한다면 판독에 도움을 줄 수 있을 것으로 생각된다.

Region of Interest Heterogeneity Assessment for Image using Texture Analysis

  • Park, Yong Sung;Kang, Joo Hyun;Lim, Sang Moo;Woo, Sang-Keun
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권11호
    • /
    • pp.17-21
    • /
    • 2016
  • Heterogeneity assessment of tumor in oncology is important for diagnosis of cancer and therapy. The aim of this study was performed assess heterogeneity tumor region in PET image using texture analysis. For assessment of heterogeneity tumor in PET image, we inserted sphere phantom in torso phantom. Cu-64 labeled radioisotope was administrated by 156.84 MBq in torso phantom. PET/CT image was acquired by PET/CT scanner (Discovery 710, GE Healthcare, Milwaukee, WI). The texture analysis of PET images was calculated using occurrence probability of gray level co-occurrence matrix. Energy and entropy is one of results of texture analysis. We performed the texture analysis in tumor, liver, and background. Assessment textural features of region-of-interest (ROI) in torso phantom used in-house software. We calculated the textural features of torso phantom in PET image using texture analysis. Calculated entropy in tumor, liver, and background were 5.322, 7.639, and 7.818. The further study will perform assessment of heterogeneity using clinical tumor PET image.