• Title/Summary/Keyword: Pet Diagnosis

Search Result 317, Processing Time 0.024 seconds

Clinical Application of $^{18}F-FDG$ PET in Alzheimer's Disease (알쯔하이머병(Alzheimer's disease)에서 FDG PET의 임상이용)

  • Ryu, Young-Hoon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.166-171
    • /
    • 2008
  • PET of the cerebral metabolic rate of glucose is increasingly used to support the clinical diagnosis in the examination of patients with suspected major neurodegenerative disorders, such as Alzheimer's disease. $^{18}F-FDG$ PET has been reported to have high diagnostic performance, especially, very high sensitivity in the diagnosis and clinical assessment of therapeutic efficacy. According to clinical research data hitherto, $^{18}F-FDG$ PET is expected to be an effective diagnostic tool in early and differential diagnosis of Alzheimer's disease. Since 2004, Medicare covers $^{18}F-FDG$ PET scans for the differential diagnosis of fronto-temporal dementia (FTD) and Alzheimer's disease (AD) under specific requirements; or, its use in a CMS approved practical clinical trial focused on the utility of $^{18}F-FDG$ PET in the diagnosis or treatment of dementing neurodegenerative diseases.

CareMyDog: Pet Dog Disease Information System with PFCM Inference for Pre-diagnosis by Caregiver

  • Kim, Kwang Baek;Song, Doo Heon;Park, Hyun Jun
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.1
    • /
    • pp.29-35
    • /
    • 2021
  • While the population of pet dogs and pet-related markets are increasing, there is no convenient and reliable tool for pet health monitoring for pet owners/caregivers. In this paper, we propose a mobile platform-based pre-diagnosis system that pet owners can use for pre-diagnosis and obtaining information on coping strategies based on their observations of the pet dog's abnormal behavior. The proposed system constructs symptom-disease association databases for 100 frequently observed diseases under veterinarian guidance. Then, we apply the possibilistic fuzzy C-means algorithm to form the "probable disease" set and the "doubtable disease" set from the database. In the experiment, we found that the proposed system found almost all diseases correctly, with an average of 4.5 input symptoms and outputs 1.5 probable and one doubtable disease on average. The utility of this system is to alert the owner's attention to the pet dog's abnormal behavior and obtain an appropriate coping strategy before consult a veterinarian.

Clinical Application of $^{18}F-FDG$ PET in Testicular Cancer (고환암에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yoon, Joon-Kee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.121-125
    • /
    • 2008
  • $^{18}F-FDG$ PET has a higher diagnostic accuracy than a in initial staging of testicular cancer. In seminoma, it can discriminate residual tumor from necrosis/fibrosis or mature teratoma. $^{18}F-FDG$ PET is also useful for the response evaluation of chemotherapy. However, there's no clinical evidence for the use of $^{18}F-FDG$ PET in the diagnosis and differential diagnosis of testicular cancer.

Clinical Application of F-18 FDG PET(PET/CT) in Malignancy of Unknown Origin (원발부위미상암에서 F-18 FDG PET (PET/CT)의 임상 이용)

  • Kim, Byung-Il
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.162-165
    • /
    • 2008
  • Diagnosis of primary origin site in the management of malignancy of unknown origin (MUO) is the most important issue. According to the histopathologic subtype of primary lesion, specialized treatment can be given and survival gain is expected. F-18 FOG PET (PET/CT) has been estimated as useful in detection of primary lesion with high sensitivity and moderate specificity. F-18 FDG PET (PET/CT) study before conventional studies is also recommended because it has high diagnostic performance compared to conventional studies. Although there has few data, F-18 FDG PET (PET/CT) is expected to be useful in diagnosis of recurrence, restaging, evaluation of treatment effect, considering that PET (PET/CT) has been reported as useful in other malignancies.

Diagnosis of Pet by Using FCM Clustering

  • Kim, Kwang-Baek
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.2
    • /
    • pp.39-44
    • /
    • 2021
  • In this paper, we propose a method of disease diagnosis system that can diagnose the health status of household pets for the people who lack veterinary knowledge. The proposed diagnosis system holds 50 different kinds of diseases with the symptoms for each of them as a database to provide results from symptom input. Each disease database has its own symptom codes for a disease, and by using the disease database, FCM clustering technique is applied to disease which outputs membership degree to determine diseases close to the input symptom as a pet diagnosis result. The implementation results of the proposed pet diagnosis system were obtained by the number of selected symptoms and the possibility values of the diseases that have the selected symptoms being sorted in descending order to derive top 3 diseases closest to the pet's symptom.

Clinical Application of $^{18}F-FDG$ PET in Malignant Melanoma (악성 흑색종에서 $^{18}F-FDG$ PET의 임상 이용)

  • Yoon, Joon-Kee
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.sup1
    • /
    • pp.140-148
    • /
    • 2008
  • $^{18}F-FDG$ PET showed a high sensitivity and specificity in the initial staging of malignant melanoma, and it also predicted the prognosis correctly. In addition, it had a higher sensitivity and specificity in the detection of recurrence and restaging than conventional imaging modalities. Meanwhile, there's less clinical evidence to support the use of $^{18}F-FDG$ PET in the response evaluation for chemotherapy and the diagnosis/differential diagnosis of malignant melanoma.

Analysis on Early Detection of Lung Cancer by PET/CT Scan

  • Wang, Huo-Qiang;Zhao, Long;Zhao, Juan;Wang, Qiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2215-2217
    • /
    • 2015
  • Background: This systemic analysis was conducted to to evaluate the application value of positron emission tomography/computed tomography (PET/CT) in early diagnosis of lung cancer. Methods: Clinical studies evaluating the application value of PET/CT for patients underwent PET/CT imaging. The histological diagnosis served as the standard of truth. Results: Four clinical studies which including 1330 patients with pulmonary spaceoccupying lesions were considered eligible for inclusion. Systemic analysis suggested that, in all 1330 patients, pooled sensitivity was 98.7% (1313.2/1330) and specificity was 58.2%(276.85/476). Conclusion: This systemic analysis suggests that integrated PET/CT imaging provides high sensitivity, and reasonably high specificity, and could be applied for early diagnosis of lung cancer.

Combination of Magnetic Resonance Spectroscopy and 11C-Methionine Positron Emission Tomography for the Accurate Diagnosis of Non-Enhancing Supratentorial Glioma

  • Nijiati Kudulaiti;Tianming Qiu;Junfeng Lu;Huiwei Zhang;Zhengwei Zhang;Yihui Guan;Dongxiao Zhuang;Jinsong Wu
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.967-975
    • /
    • 2019
  • Objective: To evaluate whether the combination of magnetic resonance spectroscopy (MRS) and 11C-methionine positron emission tomography (11C-MET PET) could increase accurate diagnostic sensitivity for non-enhancing supratentorial gliomas. Materials and Methods: Between February 2012 and December 2017, 109 patients with non-enhanced supratentorial lesions on contrast-enhanced MRI were enrolled. Each patient underwent MRS and 11C-MET PET before treatment. A lesion was considered to be a glioma when either the MRS or 11C-MET PET results reached the diagnostic threshold. The radiological diagnosis was compared with the pathological diagnosis or medical diagnostic criteria. Results: The sensitivity and specificity were 60.0% and 50.0% for MRS and 75.8% and 50.0% for 11C-MET PET, respectively. Upon combining the two modalities, the sensitivity and specificity of the imaging-based diagnosis prior to surgery reached 89.5% and 42.9%, respectively. Statistically significant differences in the sensitivities were observed between the combined and individual approaches (MRS alone, 89.5% vs. 60.0%, p < 0.001; 11C-MET PET alone, 89.5% vs. 75.8%, p = 0.001). However, no significant differences in specificity were observed between the combined and individual modalities. Conclusion: The combination of MRS and 11C-MET PET findings significantly increases accurate diagnostic sensitivity for non-enhancing supratentorial gliomas without significantly lowering the specificity. This finding suggests the potential of the combined MRS and 11C-MET PET approach in clinical applications.

Application of PET in Breast Cancer (유방암에서 PET의 응용)

  • Noh, Dong-Young
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.34-38
    • /
    • 2002
  • Positron emission tomography(PET) is an imaging method that employs radionuclide and tomography techniques. Since 1995, we applied PET not only to the diagnosis of breast cancer but also to the detection of abnormalities in the augmented breast and to the detection of metastasis. Until 2001, we evaluated 242 breast cases by PET at PET center of Seoul National University Hospital. Our group has reported serially at the international journals. In the first report, PET showed high sensitivity for detecting breast cancer, both the primary and axillary node metastasis. A total of 27 patients underwent breast operations based on PET results at Seoul National University Hospital from 1995 to 1996. The diagnostic accuracy of PET were 97% for the primary tumor mass and 96% for axillary lymph node metastasis. In case of the breast augmented, PET also showed excellent diagnostic results for primary breast cancer and axillary lymph node metastasis where mammography and ultrasound could not diagnose properly. PET also had outstanding results in the detection of recurrent or metastatic breast cancer(sensitivity 94%, specificity 80%, accuracy 89%). In addition, our study gave some evidence that PET could be applied further to evaluate the growth rate of tumors by measuring SUV, and finally to prognosticated the disease. PET could also be applied to evaluate the response after chemotherapy to measure its metabolic rate and size. In conclsion, PET is a highly sensitive, accurate diagnostic tool for breast cancer of primary lesion in various conditions including metastasis.

Evaluation of Usefulness for Diagnosis of Lung Cancer on Integrated PET-MRI Using Decision Matrix (판정행렬을 기반한 일체형 PET-MRI의 폐암 진단 유용성 평가)

  • Kim, Jung-Soo;Yang, Hyun-Jin;Kim, Yoo-Mi;Kwon, Hyeong-Jin;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.635-643
    • /
    • 2021
  • The results of empirical researches on the diagnosis of lung cancer are insufficient, so it is limited to objectively judge the clinical possibility and utilization according to the accuracy of diagnosis. Thus, this study retrospectively analyzed the lung cancer diagnostic performance of PET-MRI (Positron Emission Tomography-Magnetic Resonance Imaging) by using the decision matrix. This study selected and experimented total 165 patients who received both hematological CEA (Carcinoembryonic Antigen) test and hybrid PET-MRI (18F-FDG, 5.18 MBq/kg / Body TIM coil. VIVE-Dixon). After setting up the result of CEA (positive:>4 ㎍/ℓ. negative:<2.5㎍/ℓ) as golden data, the lung cancer was found in the image of PET-MRI, and then the SUVmax (positive:>4, negative:<1.5) was measured, and then evaluated the correlation and significance of results of relative diagnostic performance of PET-MRI compared to CEA through the statistical verification (t-test, P>0.05). Through this, the PET-MRI was analyzed as 96.29% of sensitivity, 95.23% of specificity, 3.70% of false negative rate, 4.76% of false positive rate, and 95.75% of accuracy. The false negative rate was 1.06% lower than the false positive rate. The PET-MRI that significant accuracy of diagnosis through high sensitivity and specificity, and low false negative rate and false positive rate of lung cancer, could acquire the fusion image of specialized soft tissue by combining the radio-pharmaceuticals with various sequences, so its clinical value and usefulness are regarded as latently sufficient.