• Title/Summary/Keyword: Pertechnetate

Search Result 67, Processing Time 0.028 seconds

A Study on the Thyroid Scan Images by Different Radionuclides ($^{99m}Tc$ pertechnetate and $^{131}I$) and Multiple Views (사용핵종(使用核種) 및 주사방향(走査方向)에 따른 갑상선주사상(甲狀腺走査像)의 차이(差異)에 관한 연구(硏究))

  • Whang, Il-Yong;Chung, Soon-Il;Kim, Dong-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.53-58
    • /
    • 1986
  • Thyroid scans using $Na^{131}I\;and\;^{99m}TcO_4^-$ in two (anterior and anterior oblique) projections were done simultaneously in 50 patients with single palpable nodule and in euthyroid state(nodular nontoxic goiter) and 20 normal subjects to evaluate the imaging ability of each radionuclide and the necessity of oblique view. In detection of a nodule as a cold or cool area, $^{99m}TcO_4^-$ was slightly superior to $^{131}I$(82 % to 78% with anterior view alone, 92% to 84% when oblique view is added in detectability), with addition of an oblique view, 5 more cold or cool area in $^{99m}Tc$ scan and 3 more $^{131}I$ scan were detected. In normal subjects $^{99m}TcO_4^-$ scan was significantly superior to $^{131}I$ scan(90% to 70%) in getting normal pattern of tracer uptake in the glands. For routine imaging study of the thyroid, $^{99m}Tc$ pertechnetate scan with multiple projection is considered to be a preferable method.

  • PDF

Dynamic Salivary Gland Scintigraphy in Clinical Sicca Syndrome: Comparison with Static images (구내 건조증을 호소하는 환자에서 역동적 타액선 신티그라피: 정적영상과의 비교)

  • Kim, Euy-Neyng;Sohn, Hyung-Sun;Choi, Jung-Eun;Kim, Sung-Hoon;Chung, Yong-An;Chung, Soo-Kyo;Kim, Choon-Yul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.1
    • /
    • pp.43-51
    • /
    • 2001
  • Purpose: In this study, we compared the quantitative characteristics of dynamic salivary gland scintigraphy with static scintigraphy in patients with clinical sicca syndrome using Tc-99m pertechnetate. Materials and Methods: Fifty-two parotid glands and 52 submandibular glands out of 26 patients with clinical sicca syndrome were studied by dynamic and static salivary gland scintigraphy. Ten normal volunteers were also studied as a control group for comparison of scintigraphic parameters. Ten minutes after injection of 370 MBq Tc-99m pertechnetate, we obtained pre-stimulus static images for a few minutes. Then dynamic salivary gland scintigraphy with lemon juice stimulation was performed for 20 minutes. Finally we obtained post-stimulus static images after dynamic images. On dynamic study, functional parameters such as uptake rate, secretion rate and re-uptake rate were calculated. The results of dynamic study and static images were compared. Results: On dynamic study, we could obtain functional parameters of salivary glands successfully. On dynamic study, 22 parotid glands and 22 submandibular glands out of each of 52 glands are abnormal. The static images demonstrated somewhat different results, of which reasons we could assume via dynamic study. Conclusion: Dynamic salivary gland scintigraphy using Tc-99m perechnetate were more functional than static images and might be useful in the assessment of the functional change of the salivary gland in patients with clinical sicca syndrome.

  • PDF

Effect of $Al^{3+}$ on Labeling Efficiency and Biodistribution of $^{99m}Tc$-MDP ($Al^{3+}$ 존재가 $^{99m}Tc$-MDP의 표지효율과 생체내 분포에 미치는 영향)

  • Chang, Young-Soo;Jeong, Jae-Min;Kim, Young-Ju;Kwark, Cheol-Eun;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.361-366
    • /
    • 1996
  • This study was to determine the effect of $Al^{3+}$ in $^{99m}Tc$ eluate from $^{99}Mo-^{99m}Tc$ generator on labeling efficiency and biodistribution of $^{99m}Tc$-MDP. The chromatographic analysis of $^{99m}Tc$-MDP preparations containing $Al^{3+}(0-62.5{\mu}g/ml)$ showed decreased labeling efficiency $^{99m}Tc$ pertechnetate and hydrolyzed reduced $^{99m}Tc$ fraction increased with increasing concentrations of aluminum. However, the chromatography system could not discern between hydrolyzed reduced $^{99m}Tc$ and $^{99m}Tc$ labeled colloid. $^{99m}Tc$-MDP preparations containing aluminum were relatively stable. Chromatographic analysis also confirmed that no significant differences were observed in the radiochemical purity of the filtered and the unfiltered $^{99m}Tc$-MDP preparations containing aluminum by $0.22{\mu}m$ syringe filter. In biodistribution data of ICR-mice, blood and heart uptake were increasing with increasing concentrations of aluminum, because of decreasing labeling efficiency of $^{99m}Tc$-MDP and increasing of $^{99m}Tc$ pertechnetate. However, liver and bone uptake were not significantly increased. In rat images no difference were observed at $5{\mu}g/ml\;Al^{3+}$ compare with at $0{\mu}g/ml\;Al^{3+}$, but at $10{\mu}g/ml\;Al^{3+}$ lumbar uptake was increased. As a practical conclusion, a concentration below $10{\mu}g/ml\;Al^{3+}$($10{\mu}g/ml\;Al^{3+}$ is the maximum allowed in pertechnetate eluate from $^{99}Mo-^{99m}Tc$ generator by USP.) in $^{99m}Tc$-MDP radiopharmaceutical result in low labeling efficiency. Radiochemical purity 90% of $^{99m}Tc$-MDP is the minimum allowed by USP. Therefore, when soft tissue uptake is observed in $^{99m}Tc$-MDP bone scan and labeling efficiency is above 90%, we can expect that $Al^{3+}$ in pertechnetated eluate is not the cause of soft tissue uptake.

  • PDF

Detection for Residual Thyroid Tissue and Metastatic Lesion after Total Thyroidectomy in Patients with Differentiated Thyroid Cancer: Comparison between Tc-99m Pertechnetate Sean and High Dose I-131 Therapy Sean (분화 갑상선암 환자의 수술후 잔여갑상선조직 및 전이병소의 진단: Tc-99m Pertechnetate 스캔과 고용량 옥소 치료 후 I-131 스캔의 비교)

  • Lee, Joo-Ryung;Ahn, Byeong-Cheol;Jeong, Shin-Young;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.2
    • /
    • pp.120-127
    • /
    • 2003
  • Purpose: To evaluate diagnostic sensitivity of nuclear imaging in the detection of residual thyroid tissue and metastatic lesion, we have compared neck scintigrams with Tc-99m pertechnetate (Tc-99m scan) and high dose I-131 iodide (I-131 scan) in patients with differentiated thyroid cancer. Subjects and Methods: One hundred thirty-five thyroidectomized patients for differentiated thyroid cancer were enrolled in this study. Twenty-three had a previous history of radioiodine therapy. Planar and pin-hole images of anterior neck with Tc-99m were acquired at 20 minutes after injection, followed by I-131 scan three days after high-dose radioiodine therapy within 7 days interval. Patients were asked to discontinue thyroid hormone replacement more than 4 weeks. Results: All subjects were in hypothyroid state. Seventy out of 135 patients (51.9%) showed concordant findings between Tc-99m and I-131 scans. I-131 scan showed higher number of uptake foci in all of 65 patients showing discordant finding. Tc-99m scan showed no thyroid bed uptake in 34 patients, whereas 23 of them (67.6%) showed bed uptake in I-131 scan. Tc-99m scan did not show any uptake in thyroid bed in 11 of 112 patients without previous history of radioiodine therapy, but 9 of them showed bed uptake in I-131 scan. Tc-99m scan showed no bed uptake in all of the 23 patients with previous history of radioiodine therapy, in contrast 14 of them (60.9%) showed bed uptake in I-131 scan. Conclusion: These results suggest that Tc-99m scan has poor detectability for residual thyroid tissue or metastatic lesion in thyroidectomized differentiated thyroid cancer patients, compared to high dose I-131 therapy scan. Tc-99m scan could not detect any remnant tissue or metastatic lesion in patients with previous history of radioiodine treatment, especially.

Effect of Cimetidine and Gastric Acidity on the Gastric Mucosal Retention of $^{99m}Tc-Pertechnetate$ in Rats (Cimetidine과 위산도 변화가 $^{99m}Tc-Pertechnetate$의 흰쥐 위벽 집적에 미치는 영향)

  • Kim, Sung-Hoon;Kim, Jong-Woo;Bahk, Yong-Whee
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.1
    • /
    • pp.41-48
    • /
    • 1989
  • $^{99m}Tc-Pertechnetate\;(TcO_4^-)$ is concentrated by the stomach after intravenous injection, allowing the detection of ectopic gastric mucosa. It has been used to develop a noninvasive test of gastric secretion. However the cellular site of concentration is still controversial, that is whether mucin-secreting epithelial cell or acid-secreting parietal cell. This study is planned to investigate the effects of cimetidine and gastric acidity on the retention of $TcO_4^-$ in the gastric wall of the rat. Also we further attempted to clarify the uptake and secreting cell of $TcO_4^-$ in the gastric mucosa. One hundred rats were divided into two groups, preliminary (40 rats) and main examination group (60 rats). Preliminary examination group was composed of fasting group (20 rats) for the detection of the time for reaching stable $TcO_4^-$ retention ratio in gastric wall and post-prandial group (20 rats) for the detection of the time for reaching the maximal gastric acidity. Main examination group was composed of fasting group (30 rats), which was subdivided into control group (10 rats), cimetidine group (10rats), $Mylanta^{(R)}$ group (10 rats) and post?prandial group (30 rats), which was subaivided into 90 min group (10 rats), 90 min cimetidine group (10 rats), and 120 min group (10 rats). Retention ratio (%) of $TcO_4$ in the gastric wall and the pH of the gastric contents were measured in the extracted stomach of the six groups. Gastric wall retention ratio of $TcO_4^-$ was calculated by the gastric wall radioactivity (cpm) divided by total gastric radioactivity (cpm) at 30 mins after intravenous injection of 0.4 mCi of $TcO_4^-$. The results were as follows: 1) The time required for reaching stable $TcO_4$ retention ratio and the lowest gastric PH were 30 min and 90 min, respectively. 2) In the fasting group, the gastric wall retention ratio of $TcO_4^-$ was significantly increased in the cimetidine group, compared with the control group (P < 0.01). However there was no significant difference between the control and $Mylanta^{(R)}$ group 3) The $TcO_4^-$ retention ratios of 90 min and 120 min groups were lower than that of the fasting control group (p < 0.05), either. After administration of cimetidine, the retention ratio was significantly increased in 90 min group (p < 0.01). 4) While $TcO_4^-$ retention ratio and gastric pH were well correlated in the post-prandial 120 min group (r=0.7112, p<0.05), in the post-prandial 90 min and 90 min cimetidine groups correlated poorly. However, there was no correlation in the three fasting groups at all. Referring the above results, we infer that $TcO_4^-$ is secreted into the gastric lumen by both parietal and non-parietal cells, with dominant non-parietal $TcO_4^-$ secretion in the fasting state and dominant parietal $TcO_4^-$ secretion in the stimulated state.

  • PDF

A Study on $^{99m}Tc$-pertechnetate thyroid uptake in various thyroid diseases (각종(各種) 갑상선질환(甲狀腺疾患)의 $^{99m}Tc$-pertechnetate 갑상선섭취(甲狀腺攝取)에 관(關)한 연구(硏究))

  • Choi, Sung-Jae;Min, Hae-Sook;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.8 no.1_2
    • /
    • pp.29-37
    • /
    • 1974
  • The $^{99m}Tc$-pertechnetate thyroid uptake rates(20 min) were measured in 24 healthy normal subjects, 140 patients with nontoxic goiter and 98 patients with thyrotoxicosis who were treated at the Thyroid Clinic, Seoul National University Hospital, from August 1972 to August 1973. Diagnostic reliabilities and correlations between $^{99m}TcO_4$-thyroid uptake rate (20 min) and other thyroid function tests were evaluated. The observed results were as follows 1. The $^{99m}TcO_4$-thyroid uptake rates (20 min) in normal subjects, euthyroid group and hyperthyroid group were $4.1{\pm}0.9%,\;5.2{\pm}1.8%\;and\;29.7{\pm}10.6%$. There was a significant difference between the mean of the euthyroid group and the mean of the hyperthyroid group and so differentiation between them can be easy. 2. In the diagnosis of hyperthyroidism, the reliabilities of $^{99m}TcO_4$- thyroid uptake rate(20 min), $^{131}I$ thyroid uptake rate(24hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7\;were\;87.9{\sim}97.9%,\;81.2{\sim}94.4%,\;87.9{\sim}97.9%,\;90.5{\sim}99.3%\;and\;93.7{\sim}100%$. $^{99m}TcO_4$-thyroid uptake rate(20 min) is more accurate than $^{131}I$ thyroid uptake rate (24 hrs) in the diagnosis of hyperthyroidism. 3. $^{99m}TcO_4$-thyroid uptake rate (20 min) was well correlated with $^{131}I$ thyroid uptake rate (24 hrs), serum $T_3$ resin uptake rate, serum $T_4\;and\;T_7$. Points in favor of $^{99m}Tc$ are that it gives a small radiation dose to the thyroid, that tests can be repeated at the short interval, the study can be completed at a single patient visit and it is particularly well suited for the assessment of thyroid function in patients being treated with an antithyroid drug.

  • PDF

Transcolonic scintigraphy for diagnosis of canine portosystemic shunts

  • Lee, Young-won
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.2
    • /
    • pp.390-393
    • /
    • 1999
  • Transcolonic scintigraphy using $^{99m}Technetium$ pertechnetate ($^{99m}TcO_{4}$) was performed in 5 dogs with portosystemic shunts. In all dogs, the activity in the heart was seen before liver activity. Also time activity curve was revered. The mean shunt index in 5 dogs was 82.3% (range 79.6~87.1%). Transcolonic scintigraphy is quick, simple and useful diagnostic method for canine portosysternic shunts.

  • PDF

Normal Lung Ventilation/Perfusion Scintigraphy in Miniature Pigs (미니돼지에서 정상 폐 환기/관류 신티그라피)

  • Kim, Se-Eun;Han, Ho-Jae;Shim, Kyung-Mi
    • Journal of Life Science
    • /
    • v.20 no.11
    • /
    • pp.1725-1728
    • /
    • 2010
  • Miniature pigs are widely used in experiments related to pulmonary disease because of their similarities with humans. However, there are not enough data about normal lung function in miniature pigs. Thus, in this study, we investigated normal lung function in miniature pigs with lung ventilation/perfusion scintigraphy and evaluated the availability of this method. Three male miniature pigs weighing 30-35 kg were used. After general anesthesia, ventilation scintigraphy was performed with 100 MBq of $^{99m}Tc$-pertechnetate (${O_4}^-$), after which perfusion scintigraphy was performed with intravenous injection of $^{99m}Tc$-macro aggregated albumin (MAA). The functional contribution of the right lung was about 55%, and left lung was about 45%, similar to humans. Lung ventilation/perfusion scintigraphy was very useful in evaluating the normal lung function of miniature pigs because it was a non-invasive procedure (no tissue damage was involved), took a short time and was easy to perform. In conclusion, miniature pigs are similar to humans in functional contributions of the lung, and this method will be helpful in future pulmonary disease studies involving miniature pigs.

The Usefulness of Diagnostic Scan Using Technetium-99m Pertechnetate Scintigraphy prior to the First Ablative Radioiodine Treatment in Patients with Well Differentiated Thyroid Carcinoma: A Comparative Study with Iodine-131 (분화된 갑상선암 수술 후 초치료에 있어서 Tc-99m Pertechnetate을 이용한 진단 스캔의 유용성: Iodine-131 스캔과의 비교)

  • Yoon, Seok-Nam;Park, Chan-H.;Hwang, Kyung-Hoon;Kim, Su-Zy;Soh, Eui-Young;Kim, Kyung-Rae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.285-293
    • /
    • 2000
  • Purpose: A prospective comparison was made between imaging with Tc-99m pertechnetate (Tc-99m) and Ioine-131 (I-131) for the detection of residual and metastatic tissue after total thyroidectomy in patients with well-differentiated thyroid carcinoma. Materials and Methods: Initially our patients had imaging with Tc-99m, followed by I-131 within 3 days. The study included 21 patients who had ablation with high dose of I-131 ranging from 100 mCi to 150 mCi. Planar and pinhole images were acquired for both Tc-99m and I-131. Diagnostic images of Tc-99m and I-131 were compared with post-therapy images. Degree of uptake on Tc-99m and I-131 images was scored by four point scale and compared. Results: The results of the Tc-99m study were: 16 of 19 studies (84%) were positive on simple planar images, but 19 of 20 studies (95%) were positive on pinhole images. Conventional I-131 diagnostic imaging on the other hand showed that all studies (100%) were positive on both planar and pinhole images. There was a significant difference in degree of uptake between Tc-99m and I-131 planar images (p<0.05). Only one case of Tc-99m scintigraphy was negative on both planar and pinhole studies (false negative). There was no distant metastasis on the therapeutic I-131 images. Conclusion: Tc-99m scan using pinhole in certain clinical situations is an alternative to the I-131 scan in detecting thyroid or lymph node metastasis prior to the first ablative treatment after thyroidectomy for well-differentiated thyroid carcinoma.

  • PDF