• Title/Summary/Keyword: Personal air-conditioning

Search Result 41, Processing Time 0.022 seconds

An Experimental Study on the Comfortable Room Control Conditioning Using Personal Computer (컴퓨터를 이용한 가정용 냉방기기의 실내쾌적조건 조절에 관한 실험적 연구)

  • Cho, Jin Ho;Lee, Dae Woo
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.4
    • /
    • pp.442-447
    • /
    • 1988
  • To keep comfortable indoor condition, the existing air conditioning system is controlled by the ON/OFF temperature controller. The PID control unit is developed to control temperature and humidity simultaneously, and the Air-conditioning control system is transferred from the ON/OFF temperature controller to the PID control unit for experiment. As a result of this experiment, the PID control unit reduced energy consumption compared with the ON/OFF control unit.

  • PDF

Thermal Characteristics of a Partition Supply System

  • Jeong, Ky-Bum
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.67-72
    • /
    • 2003
  • A partition integrated air supply system can provide highly personalized environmental control. The supply air is brought up through raised floors and supplied to outlets located on the partition panels. The purpose of this paper is to find out the best design of outlets for optimal occupant comfort within a personal task area. Real scale experiments were conducted to allow for comparisons of outlet designs within a personal task area. Experimental results indicate that the location of an outlet is the most critical factor in improving the efficiency of supply air distribution of a personal task area. Thermal characteristic comparisons were made between the under-floor and the partition supply systems. Experimental results suggest that the partition supply system is more efficient than the under-floor supply system in terms of cooling. Such a system allows occupants to personally control their immediate environment, resulting in higher productivity.

A PID Control of Supply Duct Outlet Air Temperature in Personal Environment Module

  • Park, Young-Chil
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.2
    • /
    • pp.82-90
    • /
    • 2003
  • The work presented here is a design and an implementation of PID control system to regulate a supply duct outlet air temperature in PEM (Personal Environment Module). In PEM, the air is heated to the required temperature while it flows through the supply duct without any mixing chamber. This makes the control of air temperature in PEM difficult. A simulation is done first to understand the relationship between a temperature distribution in working area, flow rate and the outlet air temperature of PEM. Then a linear dynamic model of heating process in PEM is derived. P, PD and PID type control systems, to provide the rapid response without overshoot and saturation in heater command voltage, are designed using a linear model obtained. Experimentally obtained data shows that the control system satisfies the design criteria and works properly in controlling the supply duct outlet air temperature.

Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System (바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가)

  • Kim Se-hwan;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

기존의 퍼스널 공조시스템의 문제점 및 그 개선방안

  • 송두삼
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.8
    • /
    • pp.41-47
    • /
    • 2004
  • 최근 국내에서도 개별제어를 지향하는 공조시스템의 오피스건물에의 적용이 적극적으로 검토되고 있으며 또 몇몇 실제 적용된 사례가 보고되고 있다. 그 내용을 보면, 바닥취출공조시스템이나 시스템 에어컨이 대부분으로 어떤 의미에서 본격적인 개별공조 (personal air-conditioning system)라고 할 수 없으며, 오히려 실의 공조죠닝을 세분화해 국부적인 재어성을 향상시킨 쾌적성 향상 또는 에너지절약 시스템이라고 할 수 있다. (중략)

  • PDF

UV Immune System of Personalized Space (개별공간의 자외선 살균 시스템)

  • Jeong, Ky-Bum;Choi, Sang-Gon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.63-70
    • /
    • 2009
  • The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria, mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.

Analysis on the Age of Air and the Air Change Effectiveness of the Personal Environmental Module System in Intelligent Buildings

  • Cho, Dongwoo
    • Architectural research
    • /
    • v.1 no.1
    • /
    • pp.47-53
    • /
    • 1999
  • An interesting of desktop air-conditioning system is the Personal Environmental Module(PEM) System. The PEM system allows the occupant to choose the desired temperature, air volume and direction of the discharged air. In this study, the measurements on the age of air and the air change effectiveness, using the tracer gas method, are carried out to analyze the ventilation performance for provision of fresh air near the breathing zone by the PEM. The relations between the PEM for optimal control and other factors related to indoor air quality, and the ventilation for the PEM are examined. Also, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The minimum local age of air was measured in the breathing zone, which is directly supplied with air from the PEM diffusers, and the measured local air change effectiveness of the desktop diffuser in the breathing zone was about 1.13 to 1.23 times greater than that of the ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

A Study on the Heat Transfer Characteristics of Liquid Droplet Radiator for Air Conditioning (공기조화용 액적방열기의 열전달특성에 관한 연구)

  • 김금무;김춘식;김용모;김종헌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.4
    • /
    • pp.17-26
    • /
    • 1995
  • In general existing air conditioning devices, which are carried out by convection heat transfer, are very popular compared with the radiation type air conditioning devices. But perconal convection tpe air conditioning units are unuseful air conditioning type because it handles amount of surrounded air to meet the temperature and humidity. In this view, this study is intended to develope personal dir conditioning units using a radiation type radiator. Liquid Droplet Radiator(L.P.R.) radiates the energy by means of thermal radiation. Radiative energy from L.P.R. is the infrared rays which heat the objects without lose of energy. It is a desirable heating method for the local area within the large room. In this study, the analysis uses the Monte Carlo methd to predict the temperature distribution in the droplet sheet and the net heat flux from the L.D.R.. And for this study and experiment was carried out to analyse the radiative and convective heat transfer characteristics in the L.D.R.. And the experiment was investigated the effects of inlet temperature, feed rate, optical thickness and droplet diameter on heat transfer characteristics of L.D.R.. The obtained results from the numerical and experimental studies of L.D.R. were as follows ; (1) The heat flux of L.D.R. was effected by extinction coefficient of droplet sheet, optical thickness and droplet temperature, surface area and emissivity of the droplet. And it was increased with the temperature, feed rate and optical thickness, on the other hand decreased with increasing of droplet diameter. (2) The experimental results for heat flux was ecalucted below 20% than that of the numerical solution by Monte Carlo method, but the tendency of the variation shows relatively good agreement.

  • PDF

A Study on Reduction of Air Conditioning Energy Consumption by Surface Albedo Variation Using Meteorological Model (기상모델을 이용한 지표면 반사능에 따른 냉방에너지 소비 저감 연구)

  • AN, Jae-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.16-24
    • /
    • 2010
  • Recently environmental regulations like the Kyoto Protocol, adopted in 1997, required the 5.2% reduction of the greenhouse gas emission in 1990. And 13th General Assembly in 2007, held in Bali of India, have agreed to duty reduction even in developing countries in 2013. Korean government needs the researches on climate change and the strategic programs for greenhouse gas reduction. In this paper Colorado State University Mesoscale Model(CSU-MM) was applied to simulate the relationship between surface albedo and air temperature. Meteorological model simulation in region of Ansan-City, Shiheung-City showed that mean air temperature became lower with the increase of albedo value. Simulated air temperature became lower $-0.16^{\circ}C$ and $-0.66^{\circ}C$ by 5% and 20% increase of albedo values respectively. And cooling energy saving amount in air conditioning process was calculated according to lowered air temperature. The reduction of air temperature resulted the reduction of air conditioning energy in personal house and commercial buildings. The increase of albedo from 5% to 20% resulted the reduction of air conditioning energy from 44,493 MWh/yr to 183,796 MWh/yr. Additionally the reduction of greenhouse gas emission through the energy saving was calculated after IPCC guideline. In terms of greenhouse gas emission $CO_2$ was reduced form -30,414 ton-$CO_2$/yr to -125,638 ton-$CO_2$/yr according to the reduction of electric energy.