• Title/Summary/Keyword: Permeate Flux

Search Result 305, Processing Time 0.023 seconds

Selective Permeate Transport Characteristics of Iodine ion at Cell Membrane Model of Thyroid which Irradiated by High Energy X-Ray (고에너지 엑스선을 조사한 갑상선의 세포막모델에서 요오드이온의 선택적 투과성 전달 특성)

  • Ko, In-Ho;Yeo, Jin-Dong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.229-238
    • /
    • 2021
  • The selective permeate transport characteristics of iodine ion at follicle cell membrane model in thyroid which irradiated by high energy x-ray(linac 6 MV) was investigated. The follicle cell membrane model used in this experiment was a polysulfonated copolymerized membrane of poly(4-vinylpyridine-co-acrylonitrile:VP-AN). The difference of membrane thickness [2 mole AN%(w/w)], fixed carrier concentration[VP-AN%(w/w)], OH- concentration were occurred at difference of I- concentration and quantity of thyroid hormone, respectively. The tensile strength in fixed carrier concentration[VP-AN% (w/w): 0-62 %] of irradiated membrane was found to be decreased about 1.2-1.8 times than non-irradiated membrane. The I- selective permeate initial flux with increase of membrane thickness [2mole AN%(w/w)], fixed carrier concentration[VP-AN%(w/ w)], OH- concentration in irradiated membrane were found to be decreased about 2.1-4.5 times, about 2.2-2.5 times, about 2.1-2.67 times than non-irradiated membrane, respectively. As a result, the quantity of thyroid hormone was decreased at irradiated membrane than non-irradiated membrane. The decrease of thyroid hormone was occurred at hypothyroidism and hyperthyroidism, thyroid cancer, and so on. As the thyroid hormone in cell membrane model were abnormal, cell damages were appeared at cell.

Analysis of EDCs by Mass Spectrometry and their Removal by Membrane Filtrations (질량분석법에 의한 내분비계 장애물질의 분석과 막 여과에 의한 제거)

  • Kim Tae-Uk;Yeon Kyeong-Ho;Cho Jaeweon;Moon Seung-Hyeon
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.297-309
    • /
    • 2005
  • As a number of potential endocrine disrupting compounds (EDCs) are released into the environment, recently growing attention has been drawn to them. Therefore sensitive and reliable analytical methods are essential to monitor those compounds. In this study, complementary CC-MS and LC-MS were employed to analyze the endocrine disrupters, and the results of two methods were compared for di(2-ethylhexyl)phthalate (DEHP), benzylbutylphthalate (BBP), pentachlorophenol (PCP), and 4,4'-Isopropylidenediphenol (Bisphenol-A, or BPA). The results indicate that it was possible to lower the detection limits of EDCs by LC-MS. Also, LC-MS enabled to identify the EDCs as almost intact molecules. Furthermore, this study presented a nanofiltration membrane (MWCO 250) and a ultrafiltration membrane (MWCO 1,000) filtration system as methods far removing EDCs from drinking water containing $\gamma$-BHC, p,p'-DDE, BBP, p,p'-DDT, DEHP, PCP, and BPA. Cross-flow type nanofiltrations showed $100\%$ removal of EDCs, and the result implies that MWCO 250 nanofilter was sufficient for treatment of EDCs. The ratio of permeate flux to mass transfer coefficient of nanofiltration, high flux ultrafiltration, and low flux ultrafiltration with ultrapure water were 0.67, 3.4, and 0.44, respectively. It was found that nanofiltration and low flux ultrafiltration were operated at a diffusion dominant condition, and the high flux ultrafiltration was operated at a convection dominant condition. Furthermore, a diffusion dominant process attained reasonable rejection of EDCs. The removal in the ultrafiltration was depending on the molecular weight of an EDC, and the filtration was governed by diffusion-dominant hydrodynamic conditions.

Membrane Biofouling of Seawater Reverse Osmosis Initiated by Sporogenic Bacillus Strain

  • Lee, Jin-Wook;Ren, Xianghao;Yu, Hye-Weon;Kim, Sung-Jo;Kim, In-S.
    • Environmental Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.141-147
    • /
    • 2010
  • The objective of this study was to assess the biofouling characteristics of the Bacillus biofilm formed on reverse osmosis (RO) membranes. For the study, a sporogenic Bacillus sp. was isolated from the seawater intake to a RO process, with two distinct sets of experiments performed to grow the Bacillus biofilm on the RO membrane using a lab-scale crossflow membrane test unit. Two operational feds were used, 9 L sterile-filtered seawater and 109 Bacillus cells, with flow rates of 1 L/min, and a constant 800 psi-pressure and pH 7.6. From the results, the membrane with more fouling, in which the observed permeate flux decreased to 33% of its initial value, showed about 10 and 100 times greater extracellular polymeric substances and spoOA genes expressions, respectively, than the those of the less fouled membrane (flux declined to 20% of its initial value). Interestingly; however, the number of culturable Bacillus sp. in the more fouled membrane was about 10 times less than that of the less fouled membrane. This indicated that while the number of Bacillus had less relevance with respect to the extent of biofouling, the activation of the genes of interest, which is initiative of biofilm development, had a more positive effect on biofouling than the mass of an individual Bacillus bacterium.

Thermo-responsive antifouling study of commercial PolyCera® membranes for POME treatment

  • Haan, Teow Yeit;Chean, Loh Wei;Mohammad, Abdul Wahab
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.97-109
    • /
    • 2020
  • Membrane fouling is the main drawback of membrane technology. Frequent membrane cleaning and membrane replacement are, therefore, required to reduce membrane fouling that causes permeate flux reduction, lower rejection, or higher operating pressure. Studies have proved that the alteration of membrane properties is the key controlling factor in lessening membrane fouling. Among stimuli-responsive membranes, thermo-responsive membrane is the most popular, with a drastic phase transition and swelling-shrinking behavior caused by the temperature change. In this study, the thermo-responsive ability of two commercial membranes, PolyCera® Titan membrane and PolyCera® Hydro membrane, at different temperatures was studied on the antifouling function of the membrane in palm oil mill effluent (POME) treatment. The evaluation of the membrane's thermo-responsive ability was done through three cycles of adsorption (fouling) and desorption (defouling) processes in a membrane filtration process. The experimental result depicted that PolyCera® Hydro membrane had a higher membrane permeability of 67.869 L/㎡.h.bar than PolyCera® Titan membrane at 46.011 L/㎡.h.bar. However, the high membrane permeability of PolyCera® Hydro membrane was compensated with low removal efficiency. PolyCera® Titan membrane with a smaller mean pore size had better rejection performance than PolyCera® Hydro membrane for all tested parameters. On the other hand, PolyCera® Titan membrane had a better hydrodynamic cleaning efficiency than PolyCera® Hydro membrane regardless of the hydrodynamic cleaning temperature. The best hydrodynamic cleaning performed by PolyCera® Titan membrane was at 35℃ with the flux recovery ratio (FRR) of 99.17 ± 1.43%. The excellent thermo-responsive properties of the PolyCera® Titan membrane could eventually reduce the frequency of membrane replacement and lessen the use of chemicals for membrane cleaning. This outstanding exploration helps to provide a solution to the chemical industry and membrane technology bottleneck, which is the membrane fouling, thus reducing the operating cost incurred by the membrane fouling.

Water desalination by membrane distillation using PVDF-HFP hollow fiber membranes

  • Garcia-Payo, M.C.;Essalhi, M.;Khayet, M.;Garcia-Fernandez, L.;Charfi, K.;Arafat, H.
    • Membrane and Water Treatment
    • /
    • v.1 no.3
    • /
    • pp.215-230
    • /
    • 2010
  • Poly(vinylidene fluoride-co-hexafluoropropylene), PVDF-HFP, hollow fiber membranes were prepared by the dry/wet spinning technique using different polyethylene glycol (PEG) concentrations as non-solvent additive in the dope solution. Two different PEG concentrations (3 and 5 wt.%). The morphology and structural characteristics of the hollow fiber membranes were studied by means of optical microscopy, scanning electron microscopy, atomic force microscopy (AFM) and void volume fraction. The experimental permeate flux and the salt (NaCl) rejection factor were determined using direct contact membrane distillation (DCMD) process. An increase of the PEG content in the spinning solution resulted in a faster coagulation of the PVDF-HFP copolymer and a transition of the cross-section internal layer structure from a sponge-type structure to a finger-type structure. Pore size, nodule size and roughness parameters of both the internal and external hollow fiber surfaces were determined by AFM. It was observed that both the pore size and roughness of the internal surface of the hollow fibers enhanced with increasing the PEG concentration, whereas no change was observed at the outer surface. The void volume fraction increased with the increase of the PEG content in the spinning solution resulting in a higher DCMD flux and a smaller salt rejection factor.

Experimental Study on Separation of Cephalosprotin C by Spiral-Wound Reverse Osmosis Module (나권형 역삼투 모듈에 의한 Cephalosporin C의 농축분리에 관한 실험연구)

  • Shin, Dong-Youp;Ryu, Jeung;Lee, Yong-Chul
    • Applied Chemistry for Engineering
    • /
    • v.10 no.4
    • /
    • pp.563-567
    • /
    • 1999
  • Reverse osmosis concentration for cephalosproin C was studied using a polyamide composite membrane, FT-30 in spiral wound type with high solute rejection. The experiments were carried out in the aqueous solution of cephalosporin C for water flux, solute rejection and mass transfer coefficient under applied pressure of $4{\sim}20kg/cm^2$, feed concentration of 100~1000 mg/L and feed velocity of 2.8 and 5.6 L/min at room temperature. The effect of operating pressure on the separation of cephalosporin C showed that permeate flux increased with increasing operation pressure. These results are consistent with those predicted by Kedem-Katchalsky model. Solute rejection was nearly 1. The increase of feed concentration caused the reduction of cephalosporin C rejection, which was higher at low concentration than at high concentration, but degree of reduction was small.

  • PDF

Dissolution Characteristics of Biphenyl Dimethyl Dicarboxylate from Solid Dispersions and Permeation through Rabbit Deuodenal Mucosa (고체분산체로부터 비페닐디메칠디카르복실레이트의 용출 특성 및 토끼의 십이지장 점막 투과)

  • Hyun, Jean;Chun, In-Koo
    • Journal of Pharmaceutical Investigation
    • /
    • v.24 no.2
    • /
    • pp.57-65
    • /
    • 1994
  • To increase the dissolution rate of practically insoluble biphenyl dimethyl dicarboxylate (DDB), various solid dispersions were prepared with water soluble carriers, such as povidone (PVP K-30), poloxamer 407, sodium deoxycholate (SDC) and polyethylene glycol (PEG) 6000, at drug to carrier ratios of 1:3, 1:5 and 1:10 (w/w) by solvent or fusion method. Dissolution test was performed by the paddle method. The dissolution rate of DDB tablets (25 mg) on market was found to be very low (11.44, 9.02 and 6.42% at pH 1.2, 4.0 and 6.5 after 120 min, respectively). However, dissolution rates of DDB from various solid dispersions were very fast and reached supersaturation within 10 min. DDB-PEG 6000 solid dispersion appeared to be better in enhancing the in vitro dissolution rate than others. Furthermore, the incorporation of DDB and phosphatidylcholine (PC) into ${\beta}-cyclodextrin$ at ratios of 1:2:20, 1:5:20 and 1:10:20 resulted in a 4.9-, 11.2- and 19.6-fold increase in DDB dissolution after 120 min as compared with the pure drug, respectively. This might be attributed to the formation of lipid vesicles which entrapped a certain concentration of DDB during dissolution. On the other hand, the permeation of DDB through rabbit duodenal mucosa was examined using some enhancers such as SDC, sod. glycocholate (SGC) and glycyrrhizic acid ammonium salt (GAA). Only trace amounts of DDB were found to permeate through deuodenal mucosa in the absence of enhancer. SDC was found to markedly decrease the permeation flux of DDB, however, SGC and GAA (5 mM) enhanced the flux of DDB 1.6 and 2.4 times higher as compared with no additive, respectively.

  • PDF

Surface Characteristics of Fouling Resistant Low-Pressure RO Membranes (상업용 내오염성 저압 RO막의 표면 특성 분석)

  • Hong, Seungkwan;Taylor, James;Norberg, David;Lee, Jinwoo;Park, Chanhyuk;Kim, Hana
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • In this study, five commercially available fouling resistant low-pressure RO membranes were investigated for the treatment of seasonally brackish surface water with high organic content (${\approx}24mg/L$). The membranes investigated are LFC-1 (Hydranautics), X20 (Trisep), BW30FR1 (FilmTec), SG (Osmonics), and BE-FR (Saehan). The results of surface characterization revealed that each of these membranes has one or two unique surface characteristics to minimize the adherence of the fouling materials to the membrane. Specifically, the LFC1 membrane features a neutral or low negative surface to minimize electrostatic interactions with charged foulants. The X20, on the other hand, shows a highly negatively charged surface, and thus, is expected to perform well with feed waters containing negatively charged organics and colloids. The BW30FR1 exhibits a relatively neutral and hydrophilic surface, which could be beneficial for lessening organic and/or biofouling. The SG membrane has a smooth surface that makes it quite resistant to fouling, particularly for colloidal deposition. Lastly, BE-FR membrane demonstrated a medium surface charge and a slightly higher hydrophobicity. In the pilot study, all of the four membranes experienced a gradual increase in MTC (water mass transfer coefficient or specific flux) over time, indicating no fouling occurred during the pilot study. The deterioration of permeate water quality such as TDS was also observed over time, suggesting that the integrity of the membranes was compromised by the monochloramine used for biofouling control.

Improvment on the filtration process of foxtail millet Yakju (좁쌀약주의 여과공정 개선에 관한 연구)

  • 강영주;고정삼
    • Food Science and Preservation
    • /
    • v.10 no.4
    • /
    • pp.482-487
    • /
    • 2003
  • The filtration effects of glass membrane filters and hollow fiber membranes with different pore size to prevent the haze of a commercial foxtail millet Yakju were investigated. The most particles(haze precusors) present in the Yakju were removed by using 1.2 $\mu\textrm{m}$ glass membrane filter. In case of using 0.45$\mu\textrm{m}$ hollow fiber membrane system, the permeate flux on the Yakju filtration was calculated to 342.8 lmh. During the 3 month storage at 4$^{\circ}C$ and room temperature for each 48 hrs in turn, alittle fine haze was observed from the Yakju even if it was filtered by using 0.7 $\mu\textrm{m}$ glass membrane filter. Anything of haze was, however, observed from the Yakju filtered by using all of hollow fiber membranes. Therefore, the 0.45$\mu\textrm{m}$ hollow fiber membrane system was effective as a final filtration process of the Yakju.

Permeation Apparatus for on-line Measurement of the Permeation Characteristics through Dense Polymeric Membranes (투과특성의 on-line 측정을 위한 투과장치)

  • 염충균;김범식;김철웅;김광주;이정민
    • Membrane Journal
    • /
    • v.8 no.2
    • /
    • pp.86-93
    • /
    • 1998
  • A permeation apparatus has been devdoped which could make the on-line measurements of both flux and permeate composition. Pervaporative experiment of a single component, i.e. water was performed by using poly(vinyl alcohol) membrane crosslinked with glutaraldehyde to confirm the validity of the apparatus. In the experiment, steady-state permeation was obtained in 15 minutes and the measurement could be completed within 20 minutes. A comparison of the on-line measurement was made with the fluxes measured simultaneously by the conventional method in which the permeates were collected by liquid nitrogen. The on-line measurement by the apparatus showed an excellent agreement with the conventional measurement within a difference of $\pm$2%. From the flux data with operating time, 3 kinds of diffusion coefficients of water $D_{slope}, D_{1/2}$, and $D_t$ were determined, which were also coincident with values in a literature. It was confirmed that accurate measurements of fluxes could be obtained from the apparatus.

  • PDF