• Title/Summary/Keyword: Permeability of magnetic flux

Search Result 70, Processing Time 0.024 seconds

A Feasibility Study for Estimating Prestressed Stress on a Steel Wire Using Permeability of Magnetic Flux (자속투과율을 이용한 부착식 PSC 강선의 긴장응력 추정 타당성 연구)

  • Kim, Byeong Hwa;Joh, Chang Bin;Lee, Do Hyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.219-225
    • /
    • 2013
  • This work examines the feasibility for estimating existing tensile stress on a stressed wire using the permeability of magnetic flux. A closed magnetic circuit has been constructed to induce magnetic flux inside a steel wire. With different tension stress levels on a wire, the permeability of magnetic flux on the wire has been measured. Two different experimental case studies have been conducted for the examination of sensitivity of permeability of magnetic flux on the stressed wire. One is a varying-length stress test, and the other is a fixed-length stress test. The results show that the permeability of magnetic flux in the varying-length stress test is inversely proportional to the applied stress, while the permeability in the fixed-length stress test is linearly proportional to the applied stress on the stressed wire. It is thus expected that the permeability of magnetic flux on a wire can be a promising indicator for the inspection of its tensile stress.

Permeability of Magnetic Flux of PS Steel for Variation of Stress and Temperature (긴장재의 응력 및 온도변화에 따른 자속투과율)

  • Park, Jin Su;Kim, Byeong Hwa
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.3
    • /
    • pp.323-331
    • /
    • 2022
  • An experimental study was conducted to investigate the effect of applied tensile force and temperature on the permeability of magnetic flux in prestressing steel. The permeability of magnetic flux is the ratio at which the magnetic flux between two points passes. The prestressing steel used in these experiments included a 7-mm PS wire mainly used for cable-stayed bridges and a 12.7-mm PS strand for prestressed concrete bridges. The experiments to extract the permeability of the magnetic flux of steel wire and strand were conducted under various tensile levels and temperature conditions. From the experimental results, it was observed that the permeability of magnetic flux of the PS tension material was linearly proportional to the applied tensile stress level, and inversely proportional to the temperature. If the experimental relationship among the magnetic permeability, temperature, and prestressing ratio of a PS tension material is known in advance, the current tension stress level on PS members can be evaluated by measuring solely the magnetic permeability and temperature.

A Study on the Numerical Analysis of Magnetic Flux Density by a Solenoid for MIAB Welding (MIAB용접에서 코일에 의한 자속밀도 분포의 수치적 해석에 관한 연구)

  • Choe, Dong-Hyeok;Kim, Jae-Ung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.12
    • /
    • pp.73-81
    • /
    • 2001
  • The MIAB welding uses a rotating arc as its heat source and is known as an efficient method fur pipe butt welding. The arc is rotated around the weld line by the electro-magnetic force resulting from the interaction of arc current and magnetic field. The electro-magnetic force is affected by magnetic flux density, arc current, and arc length. Especially, the magnetic flux density is an important factor on arc rotation and weld quality. This paper presents a 2D finite element model for the analysis of magnetic flux density in the actual welding conditions. The magnetic flux density is mainly dependent on gap between two pipes, the position of coil from gap center, exciting current, and relative permeability. Thus, the relations between magnetic flux density and main factors were investigated through experiment and analysis. Experiments were performed for the steel pipes(48.1mm O.D and 2.0mm thickness). The analysis results of magnetic flux density reveal that it increases with increasing exciting current, increasing relative permeability, decreasing distance from gap center to coil, and decreasing gap size. It is considered that the results of this study can be used as important data on the design of coil system and MIAB welding system.

  • PDF

Numerical Study on the Magnetic Flux Distribution of a Magnetic Fluid Seal (자성유체시일의 자속분포에 관한 수치적 연구)

  • 김청균;차백순;민진기;정성천
    • Tribology and Lubricants
    • /
    • v.14 no.3
    • /
    • pp.32-38
    • /
    • 1998
  • This paper presents the magnetic flux distributions of a ferrofluid seal at the sealing gap between the pole pieces and the rotating shaft. The optimized shape of pole pieces has been determined by using the computer simulations. The computed results indicate that the sloped pole piece of 27$^{\circ}$ shows good flux distributions compared with that of the conventional flat pole pieces and may reduce frictional heats due to a reduced surface contact areas of magnetic fluids.

Analysis of the Rotational Magnetic Field using the FEM and the 2-Dimensional Permeability Tensor (유한 요소법과 이차원 텐서를 이용한 회전자계의 특성 해석)

  • Lee, Chang-Hwan;Kim, Hong-Kyu;Jung, Hyun-Kyo;Hong, Sun-Ki
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.169-171
    • /
    • 1996
  • Recently, the finite element analysis(FEM) using two dimensional magnetic permeability tensor was introduced to calculate the magnetic field considering the rotational hysteresis. We obtain the tensor matrix from the measured data using two-dimensional magnetic measuring apparatus. We calculate the induced magnetic flux density and the rotational hysteresis loss under the model with the same condition with the measuring apparatus. Therefore we show that FEM with tensor can be used to calculate the magnetic flux density and the rotational hysteresis loss in the arbitrary rotational magnetic field.

  • PDF

Development of Superior Fe-Si Sintered Magnetic Cores Equivalent to Wrought Si-steels

  • Hamano, Aya;Isihara, Chio;Asaka, Kazuo
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.799-800
    • /
    • 2006
  • Wrought Si-steels are generally used for electromagnetic valves, which are needed good response. To date, Hitachi Powdered Metals Co., Ltd. have produced Fe-Si base sintered magnetic material, EU-52, which shows a magnetic flux density of more than 1.25T at 2000A/m and a maximum permeability of more than 3500. However these magnetic properties are lower than that of wrought Si-steels. Because EU-52 has a low density of $7.2Mg/m^3$. For improving the magnetic properties, it is necessary to increase the density of sintered cores. To increase density, a new mixing method of coating fine Si powders on atomized iron powders was developed, for avoiding the Kirkendall effect. As the result, developed P/M Fe-Si magnetic cores shows higher density of $7.38Mg/m^3$, higher magnetic flux density of 1.48T at 2000A/m and higher maximum permeability of 6800.

  • PDF

The Effect of the Processing Conditions on the Magnetics Properties of Mn-Zn ferrite (제조공정에 따른 Mn-Zn 페라이트의 전자기적 특성변화)

  • 김종령;이해연;김현식;오영우;민복기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.905-908
    • /
    • 2001
  • The microstructure and the magnetic properties of Mn-Zn ferrite, which were power loss and saturation magnetic flux density, were investigated as the function of the process before firing. The highest initial permeability and the lowest power loss were attained to the specimen with CaO 400 ppm as a resulted from the highest solubility to SiO$_2$and the creation of liquid phase which improved sintering. The biggest grain size, the highest saturation magnetic flux density and the lowest power loss, which was resulted from that the eddy current loss increased as grain size increased but the hysteresis loss much more decreased and the hysteresis loss strongly influenced on the total power loss rather than the eddy current loss, were obtained to the Mn-Zn ferrite added 2wt% PVA. The power loss was lowest and the saturation magnetic flux density was highest in case of 1 ton/$\textrm{cm}^2$ and the grain size was not influenced.

  • PDF

Magnetic properties of high silicon steel processed by powder metallurgy (분말야금 공정에 의한 고규소강의 자성특성)

  • Yim, Tai-Hong;Chung, Hyung-Sik;Kang, Won-Koo;Chung, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1990.07a
    • /
    • pp.231-235
    • /
    • 1990
  • Soft magnetic silicon steels containing up to 6.5wt% of silicon were prepared by powder metallurgical processing and their magnetic properties were evaluated. The magnetic properties of P/M silicon steels are similarly affected by the silicon addition as those of conventional ingot processed ones but are also significantly affected by density and interstitial impurities particularly oxygen content. Magnetic flux density, $B_{10}$ and coercivity, Hc, tends to decrease with silicon content whereas maximum permeability, ${\mu}m$, decreases first and then increases rapidly above 5 wt% silicon. Increasing density also increases magnetic flux density and maximum permeability but reduces coereivity. The latter two properties are, however, affected more strongly with oxygen content.

  • PDF

Investigation of Shielding Effects of High Conductivity of High Permeability Materials on 60Hz ELF Magnetic Fields (60Hz ELF 자계에 대한 고 도전율 및 고 투자율 재료의 차폐효과 분석)

  • Song Ki-Hyun;Myung Sung-Ho;Min Suk-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.4
    • /
    • pp.166-171
    • /
    • 2005
  • Shielding methods on ELF(Extremely Low Frequency) magnetic fields may include the use of induced currents, modification of magnetic field flux patterns using high permeability and/or high conductivity materials, and others. The magnetic shielding properties of enclosures can be utilized to reduce the magnetic field of current carrying conductors. In this paper, to get a more practical understanding of shielding phenomena, we have investigated the magnetic field reduction by means of 3 dimensional numerical analysis and experiments. We found copper could reduce flux density more then permalloy in both cases of box shield and cylindrical shield. Iron under l0$\mu$T of 1 phase could reduce flux density about $20\%$ more than silicon steel, but both of them under 50$\mu$T has a similar reduction rate of $10\%$. The 3 phase horizontal model gave the highest reduction rate and the 1mm thickness iron under 10$\mu$T of 3 phase lines did lowest.

Analysis of Wireless Power Transfer Using Metamaterial Slabs Made of Ring Resonators at 13.56MHz

  • Oh, TaekKyu;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.13 no.4
    • /
    • pp.259-262
    • /
    • 2013
  • This paper analyzes the effects of metamaterial slabs with negative permeability when applied to a two-loop wireless power transmission (WPT) system, both in theory and electromagnetic (EM) simulations. The analysis of magnetic flux focusing provided here assumes quasi-magnetostatics or magnetostatics. The slab structures with negative permeability have been realized using the periodically arrayed ring resonators (RRs) at 13.36MHz. Some examples with ideal lossless slabs of -1, -2, and -3 showed a great enhancement of WPT efficiencies when compared with the free space cases. However, practical lossy slabs made of planar copper RRs did not show significant enhancement of WPT efficiencies due to the relatively high losses in the ring resonator (or in the slab consisting of RRs) near the resonant frequency.