• Title/Summary/Keyword: Peripheral blur

Search Result 4, Processing Time 0.032 seconds

The Effect of Accommodation Cue Manipulation at Stereoscopic Display on Binocular Fusion (양안식 디스플레이에 제시되는 자극의 조절단서 조작이 양안융합에 미치는 영향)

  • Park, Jong-Jin;Kim, Shinwoo;Li, Hyung-Chul O.
    • Journal of Broadcast Engineering
    • /
    • v.27 no.4
    • /
    • pp.569-580
    • /
    • 2022
  • In this study, we investigated the effect of peripheral blur on binocular fusion to resolve binocular fusion failure which is one of the 3D visual fatigues in the perspective of human visual system. With stimulus having discrete disparity change, binocular fusion failure rate for target stimulus having crossed and uncrossed disparity decreased. And target stimulus having continuous disparity also required relatively larger binocular disparity when peripheral blur was presented with target stimulus rather than when peripheral blur was not presented. These results imply that peripheral blur facilitated binocular fusion in the situation of binocular disparity change, and suggest that considering the characteristics of human three-dimensional visual systems, manipulating 3D contents can improve visual discomfort caused by binocular displays at low costs.

Cause Analysis in Decrease of Body Stability According to The Induced Astigmatic Blur (유발된 난시성 흐림에 의한 신체 안정성 감소의 원인분석)

  • Kim, Sang-Yeob;Yu, Dong-Sik;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.3
    • /
    • pp.259-264
    • /
    • 2016
  • Purpose: To establish the cause of decrease in body stability and to analyze the effects on sensory organs maintaining static balance according to the induced astigmatic blur. Methods: Twenty subjects (10 males, 10 females; mean age, $23.40{\pm}2.70years$) were participated in this study. To induce myopic simple astigmatism, the axis directions of cylindrical lenses were placed $180^{\circ}$ on both eyes (with-the-rule), $90^{\circ}$ on both eyes (against-the-rule), and $45^{\circ}$ on both eyes (oblique). Cylindrical lenses of +0.50, +1.00, +1.50, +2.00, +3.00, +4.00, and +5.00 D were used to increase astigmatic blur in each astigmatism types. General stability (ST) and sway power (SP) in frequencies by each sensory organs were analyzed using the TETRAX biofeedback system. Results: ST in the all astigmatism types were raised with increase of astigmatic blur compared to full corrected condition, but a significant difference only showed in the induced oblique astigmatism. According to the results of correlation analysis between ST and SP in the each frequencies with increase of astigmatic blur, the causes of increased ST in the induced oblique astigmatism showed to have a high correlation in order of somatosensory system (high-medium frequency), central nervous system (high frequency), peripheral vestibular system (low-medium frequency), and visual system (low frequency). Conclusions: The visual information by uncorrected oblique astigmatism may disturb the normal functions of all sensory organs maintaining body balance, consequently, the body stability can be reduced. Therefore, optimal correction of astigmatism can play an important role for reducing the instability of body balance.

Non-Dyadic Lens Distortion Correction and Image Enhancement Based on Local Self-Similarity (자기 예제 참조기반 단계적 어안렌즈 영상보정을 통한 주변부 열화 제거)

  • Park, Jinho;Kim, Donggyun;Kim, Daehee;Kim, Chulhyun;Paik, Joonki
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.10
    • /
    • pp.147-153
    • /
    • 2014
  • In this paper, we present a non-dyadic lens distortion correction model and image restoration method based on local self-similarity to remove jagging and blurring artifacts in the peripheral region of the geometrically corrected image. The proposed method can be applied in various application areas including vehicle real-view cameras, visual surveillance systems, and medical imaging systems.

Analysis of the Effect of Entry-Level 3D Printer Materials on CT Images (보급형 3D프린터 재료가 CT 영상에 미치는 영향 분석)

  • Se-Hwan, Park;Hyun-Jung, Jo;Sung-Jun, Lee;Song-Bin, Lee;Sang-Hyub, Park;Dae-Yeon, Ryu;Yeong-Cheol, Heo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.673-680
    • /
    • 2022
  • In this study, based on PLA, we analyzed the Hounsfield Unit (HU) of materials containing 20% each of aluminum, wood, copper, carbon, and marble, and tried to analyze how they affect the image. A cylindrical phantom of 5×30×30 ㎣ (thickness×diameter×height) was fabricated using a entry-level 3D printer. The kV was changed to 80, 100 and 120, and the mAs was changed to 100 and 200 mAs, and the phantom in the center of the table was cross-scanned under a total of six conditions. A circular ROI was set using image J program and the quantification value of the material part HU and the quantification value of the peripheral part CNR were obtained. The HU average of the material part increased in the order of [PLA - wood 20%], [PLA - marble 20%], [PLA - carbon 20%], [PLA 100%], [PLA - aluminum 20%], [PLA - copper 20%] (p<0.05) a negative correlation was confirmed with the HU by increasing kV. It was confirmed that the CNR value in the peripheral area increased in the order of [PLA - marble 20%], [PLA - copper 20%], [PLA - carbon 20%], [PLA - wood 20%], [PLA - aluminum 20%], and [PLA - 100%] (p<0.05). Human organs with similar HU values for each material are [PLA - copper 20%] compact bone, [PLA - aluminum 20%] cancellous bone, [PLA 100%] coagulated blood, [PLA - carbon 20%] and [PLA - marble 20%] liver, muscle, spleen and [PLA - wood 20%] had similar values to fat. In addition, we confirmed the blur phenomenon that blurs the image around the filament with all materials, and confirmed that [PLA 100%] especially has the most blur around the filament. Therefore, it is considered desirable to reflect the HU value of the target organ and consider cloudiness around the phantom when selecting materials for medical phantom fabrication, and this research can provide basic data.