• Title/Summary/Keyword: Periotest

Search Result 71, Processing Time 0.021 seconds

Effects of drilling process in stability of micro-implants used for the orthodontic anchorage (고정원을 위한 micro-implant 매식시 drilling 유무에 따른 안정성에 관한 연구)

  • Chang, Young-Il;Kim, Jong-Wan
    • The korean journal of orthodontics
    • /
    • v.32 no.2 s.91
    • /
    • pp.107-115
    • /
    • 2002
  • The aim of this study was to investigate experimentally the mechanical and histological effect of drilling process on the stability of micro-implant used for the orthodontic anchorage. For this purpose, 32 micro-implants(Osas$^{(R)}$, Epoch medical, ${\phi}$1.6 mm) were inserted into maxilla, mandible and palate in two beagle dogs. 16 micro-implants(8 per dog) were inserted after drilling with pilot drilling bur (drill method group). 16 micro-implants(8 per dog) were inserted without drilling (drill-free method group). After 1 week, micro-implants were loaded by means of Ni-Ti coil spring (Ni-Ti springs-extension$^{(R)}$, Ormco) with 200-300 gm force. Following 12 weeks, the micro-implants and the surrounding bone were removed. Before sacrifice, the mobilities were tested with Periotest$^{(R)}$(Siemens). Undecalcified serial sections with the long axis were made and the histologic evaluations were done. The results of this study were as follow ; 1. The osseointegration was found in both of drill-free method group and drill method group 2. Two of drill method group and one of drill-free method group in 32 micro-implants were lost after loading. 3. The mobilities of drill-free method group were less than drill method group 4. The bone contact on surface of micro-implants in drill-free method group was more than drill method group but there was no significant difference between groups. 5. The bone density in threads of micro-implants in drill-free method group was more than drill method group and there was significant difference between groups. These results suggest that drill-free method in insertion of micro-implants is superior to drill method on the stabilities, bone remodeling and osseointegrations under early loading.

On the osseointegration of zirconia and titanium implants installed at defect site filled with xenograft material (이종골 이식을 동반한 지르코니아와 타이타늄 임플란트의 골유착에 관한 연구)

  • Kim, Sung-Won;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Purpose: The purpose of this study was to compare zirconia implants with titanium implants from the view point of biomechanical stability and histologic response on osseointegration when those were placed with xenograft materials. Materials and methods: Specimens were divided into two groups; the control group was experimented with eighteen titanium implants which had anodized surface and the experimental group was experimented with eighteen sandblasted zirconia (Y-TZP) implants. At the tibias of six pigs, implants were installed into bone defect sites prepared surgically and treated with resorbable membranes and bovine bone. Two pigs were sacrificed after 1, 4 and 12 weeks respectively. Each implant site was sampled and processed for histologic and histomorphometric analysis. The stability of implants was evaluated with a $Periotest^{(R)}$. And the interfaces between bone and the implant were observed with a scanning electron microscope. Results: In stability analysis there was no significant difference between Periotest values of the control group and the experimental group. In histologic analysis with a light microscope after 4 weeks, there was new bone formation with the resorption of bovine bone and the active synthesis of osteoblasts in both groups. In bone-implant contact percentage there was significant difference between both groups (P<.05). In bone area percentage there was no significant difference between both groups. In analysis of both groups with a scanning electron microscope there was a gap between bone and a surface at 4 weeks and it was filled up with bone formed newly at 12 weeks. Conclusion: When accompanied by xenograft using membrane, bone to implant contact percentage of zirconia implants used in this experiment was significantly less than that of the titanium implants by surface treatment of anodic oxidation. So, it is considered that the improvement of zirconia implant is needed through ongoing research on surface treatment methods for its practical use.

Healing of the bone around pure titanium implants without primary bone contact (초기 골 접촉이 없는 순수 티타늄 임프란트 주위 골의 치유반응)

  • Ahn, Jae-Hyun;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.233-249
    • /
    • 1999
  • Primary fixation is one of the most important factor in establishing adequate osseointegration between implant and bone. To evaluate the initial healing response of bone around implants without primary bone contact, this study was designed to create considerable space between implant and bone in 5 mongrel dogs, about 1-year old. After 3 holes of 6.0mm in diameter were prepared at the femur neck of the dogs, commercially pure titanium thread type implants(STERI-$OSS^{(R)}$), 8mm in length and 3.8mm, 5.0mm and 6.0mm in diameter, were inserted. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), and the penetration of upper soft tissue into the gap was inhibited by it. The each implant was positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 were inserted in 2 dogs for mobility test and removal torque test.Fluorescent dyes were injected in order of Doxycycline, Alizarin Red S, and Calcein at intervals of 2 weeks. At 4-, 8-, and 12-week after placement, 3 dogs were sacrificed for histologic observation, and at 8- and 12-week after placement, 2 dogs were sacrificed for mobility test using $Periotest^{(R)}$ (Simens AG, Bensheim, Germany) and torque test using Autograph AGS-1000D $series^{(R)}$(Japan). The result were as follows: 1. The wider the gap between bone and implant was, the less bone maturity was, and the later osseointegration was occurred. Trabecular direction of new bone around implant was changed from parallel to perpendicular to the implant, and the gap was filled with new bone, over time. 2. There was a decreasing tendency over time in the mobility of all implants, but the wider gap between bone and implant was, the smaller decrease of the mobility was. 3. There was a increasing tendency over time in the removal torque gauge of all implants, and the wider gap was, the smaller increase of the removal torque gauge was. The results suggest that osseointegration in case of implant without primary bone contact may be obtained by guided bone regeneration technique with prolonged healing period, but the time of second surgery should be considered carefully.

  • PDF

Healing of the Bone around Hydroxyapatite-Coated Implants without Primary Bone Contact (초기 골 접촉이 없는 수산화 인회석 피복 임프란트 주위 골의 치유)

  • Cho, Hyung-Soo;Shin, Kwang-Yong;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.2
    • /
    • pp.415-433
    • /
    • 1999
  • Implant stability is the key to long-term successful outcome for osseointegrated implants. To evaluate the initial healing response of bone around HA-coated implants without primary bone contact. 21 HA-coated thread type implants(STERI-OSS?) were placed in the femurs of 5 mongrel dogs, about 1-year old. Implants, 8 mm in length and 3.8mm(experimental 1group), 5.0mm(experimental 2group) and 6.0mm(control group) in diameter, were inserted after 3 holes of 6.0mm in diameter and 10mm in depth were prepared in the surgical sites each dog. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), in order to prevent the ingrowth of upper soft tissue into the gap between bone and implant, and to maintain each implant to be positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 implants were inserted in 2 dogs for mobility test and removal torque test. Fluorescent dyes were injected for the observation of new bone formation in order of $Terramycin^{(R)}$, Arizarin $Red^{(R)}$, and $Calcein^{(R)}$ at an interval of 2 weeks. 3 dogs were sacrificed for histologic observation at 4, 8, and 12-week after placement. Light microscopy and confocal laser scanning microscopy were used to qualitatively characterize the bone around HA-coated implant. 2 dogs were sacrificed for mobility test($Periotest^{(R)}$, Simens AG, Bensheim, Germany) and removal torque test($Autograph^{(R)}$ AGS-1000D series, Japan) at 8 and 12-week after placement The results were as follows: 1. Histologic observation showed that osseointegration occurred to both control and experimental groups as time lapse, but delayed bone healing was revealed in 3.8mm group (experimental 1group), compared to contrtol group and 5.0mm group (experimental 2group). 2. The mobility test showed that the experimental groups had no distinguishable movement during experimental periods of 8 and 12-week, and there was no difference in mobility depending on the gap between bone and implant, and time lapse. 3. The removal torque forces were increased depended on the gaps decreasing between bone and implant, and time lapse. The results suggest that HA-coated implant without primary bone contact, based on guided bone regeneration could obtain its stability in all experimental groups as time lapse, but bone healing was delayed in experimental group of 3.8mm. And the results suggested that studies on correlationship between mobility test and removal torque test for implant stability would be necessary.

  • PDF

Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study

  • Han, Ho-Chyul;Lim, Hyun-Chang;Hong, Ji-Youn;Ahn, Su-Jin;Han, Ji-Young;Shin, Seung-Il;Chung, Jong-Hyuk;Herr, Yeek;Shin, Seung-Yun
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.4
    • /
    • pp.254-265
    • /
    • 2016
  • Purpose: The aim of this study was to determine the influence of anatomical conditions on primary stability in the models simulating posterior maxilla. Methods: Polyurethane blocks were designed to simulate monocortical (M) and bicortical (B) conditions. Each condition had four subgroups measuring 3 mm (M3, B3), 5 mm (M5, B5), 8 mm (M8, B8), and 12 mm (M12, B12) in residual bone height (RBH). After implant placement, the implant stability quotient (ISQ), Periotest value (PTV), insertion torque (IT), and reverse torque (RT) were measured. Two-factor ANOVA (two cortical conditions${\times}$four RBHs) and additional analyses for simple main effects were performed. Results: A significant interaction between cortical condition and RBH was demonstrated for all methods measuring stability with two-factor ANOVA. In the analyses for simple main effects, ISQ and PTV were statistically higher in the bicortical groups than the corresponding monocortical groups, respectively. In the monocortical group, ISQ and PTV showed a statistically significant rise with increasing RBH. Measurements of IT and RT showed a similar tendency, measuring highest in the M3 group, followed by the M8, the M5, and the M12 groups. In the bicortical group, all variables showed a similar tendency, with different degrees of rise and decline. The B8 group showed the highest values, followed by the B12, the B5, and the B3 groups. The highest coefficient was demonstrated between ISQ and PTV. Conclusions: Primary stability was enhanced by the presence of bicortex and increased RBH, which may be better demonstrated by ISQ and PTV than by IT and RT.

THE EFFECT OF DIFFERENT SURFACE TREATMENT ON THE OSSEOINTEGRATION AND STABILITY OF IMPLANTS (처리 방법이 다른 표면이 임플랜트의 골유착 및 안정성에 미치는 영향)

  • Yang, Seoung-Wook;Lim, Heon-Song;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.5
    • /
    • pp.606-616
    • /
    • 2006
  • Purpose: This experiment examined the effect of different surface treatment on the osseointegration and stability of implants. Material and methods: In this study, 40 each of machined, SLA and RBM implants, which are the most commonly used implants, were implanted into the tibia of 20 normal rabbits using $OsseoCare^{TM}$. The rabbits were sacrificed after 1 week, 4 weeks, 8 weeks and 12 weeks for implant stability analysis, removal torque analysis, histologic and histomorphometric analysis. Result : ISQ showed significant difference between Machined and RBM at first week and at 4 weeks. There was significant difference between Machined and both SLA and RBM(p<0.05) but after 8 weeks there were no significant difference between each group. In the removal torque, RBM showd significantly higher values than SLA and Machined surface at 1st week. At 4th and 12th week, there was significant difference between Machined and SLA, RBM(p<0.05). In the bone to implant contact variable, there was no significant difference between each surface treatment method. In the Machined surface group, there was no significant difference between each time interval. but in SLA group, there were significant differences between the 1st week and 12th week and in RBM group, there were significant differences between the 1st week and 8th, 12th week and between 4th and 12th week(p<0.05). The bone area showed significantly higher values in SLA and RBM compared to Machined surface 1st and 8th week and significantly higher values in SLA than Machined surface at the 4th week(p<0.05). Conclusion: The roughened surface of implants showed positive effect in the early stages of implantation and assisted in bone formation After the bone formation stage, there was no statistical difference between Machined and roughened surface groups. In dental implantation, where initial stability is critical to the success of implants, the use of roughened surface implants should assist in reducing the healing period after implantation.

Clinical Evaluation of Tooth Mobility Following Root Planing and Flap Operation (치근활택술과 치은박리소파술 후 치아동요도 변화에 관한 연구)

  • Pang, Eun-Kyoung;Chai, Jung-Kiu;Kim, Chong-Kwan;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.4
    • /
    • pp.893-914
    • /
    • 1999
  • Tooth mobility may be the decisive factor that determines whether dental treatment of any kind is undertaken. Although tooth mobility in isolation says little in itself, the finding of increased tooth mobility is of both diagnostic and prognostic importance. Only the detection of an increase or decrease in mobility makes an evaluation possible. Thus prior to treatment, we must understand the pathologic process causing the observed the tooth mobility and decide whether the pattern and degree of observed tooth mobility is reversible or irreversible. And then it must be decided whether retention and treatment or extraction and replacement. The purpose of this study was to compare tooth mobility at different time period during root planing and flap operation and to relate changes in mobility to each treatment method. Twenty-one patients (287 teeth) with chronic adult periodontitis were treated with root planing(control group) and flap operation(experimental group), and each group was divided 3 subgroups based upon initial probing pocket depth (1-3mm, 4-6mm, 7mm and more). Tooth mobility was measured with $Periotest^{(R)}$ at the day of operation, 4 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 8 weeks, 12 weeks after each treatment. Tooth mobility, attachment loss, radiographic bone loss, and bleeding on probing were measured at the day of operation, 4 weeks, 8 weeks and 12 weeks after treatment. 1. In group initial probing depth was 1-3mm, tooth mobility had no significant difference after root planing and flap operation. 2 . In group initial probing depth was 4-6mm, 7mm and more, tooth mobility had decreased in 12 weeks after root planing(p<0.01). And the mobility had increased after flap operation(p<0.01) and was at peak in 1 week, and decreased at initial level in 4 weeks, below the initial level in 12 weeks(p<0.01). 3. In 1 week, significant difference in tooth mobility between control and experimental group was found(p<0.01) but, in 12 weeks no difference between two groups was found. 4. Change of immediate tooth mobility after treatment was more larger in deep pocket than in shallow one. In group with the same probing pocket depth, the change of tooth mobility in molar group was greater than that of premolar group. 5. Tooth mobility before treatment was more strongly correlated with radiographic bone loss (r=0.5325) than probing depth, attachment loss and bleeding on probing, in 12 weeks after treatment, was more strongly correlated with attachment loss($r^2$=0.4761) than probing depth and bleeding on probing. Evaluation of the treatment effect and the prognosis after root planing and flap operation were meaningful on tooth initial probing depth 4mm and more. After flap operation, evaluation of the prognosis should be performed at least in 4 weeks and in 12 weeks after treatment, no difference in tooth mobility between two groups was observed. Radiographic bone loss and attachment loss were good clinical indicators to evaluate tooth mobility.

  • PDF

A CLINICAL AND RADIOLOGICAL STUDY ON THE EFFECT OF SYNTHETIC BONE IN CLASS II AND III FURACATION INVOLVEMENTS (2급 및 3급 치근이개부 병변에서 합성골이식의 효과에 대한 임상적 및 방사선학적 연구)

  • Yum, Kyu-Sun;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.23 no.3
    • /
    • pp.475-492
    • /
    • 1993
  • The effect of synthetic bone materials was assessed in the patients with pure periodontal class II and III furcation defects. The buccal aspects of the maxillary and mandilular first and second molars were surgically exposed, and synthetic bone materials were interposed between the gingival flap and the furcation defects in the experimental group. The control group were treated without the use of synthetic bone materials by same operator. Probing pocket depth, gingival recession, and loss of attachment, were measured by Michigan O-probe and tooth mobility was evaluated by an electronic mobility tester(Periotest(R), Siemens co. Germany) at preoperation and 3-, 6-, and 12-month postoperation. Standardized radiogrphs were taken at preoperation and 6-month and 12-month postoperation. The postoperative change of clinical parameters and the difference between experimental group and control group were statistically analyzed by Student, t-test. The results were as follows: 1. The probing pocket depth at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at preoperative examination in both experimental group and control group(P<0.005), but there was no significantly difference between experimental group and control group. 2. The amount of gingival recession at the 3-, 6-, and 12-month postoperative examination was increased, compared to that at the preoperative examination in both experimental and control group(P<0.005). In the case of the class III furcation involvement, the amount of gingival recession at the 3-, 6-, and 12-month postoperative examination was more significantly increased in control group than experimental group(P<0.05). 3. The amount of loss of attachment at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at the preoperative examination in both experimental and control group in the case of class II furcation involvement, and in experimental group only in the case of furcation III involvement(P<0.005). The amount of loss of attachment at, the 3-, 6-, and 12-month postoperative examination was more significantly decreased in experimental group than control group in the case of the class III furcation involvement(P<0.05), but in the case of class II furcation involvement there was no significant difference between experimental group and control group. 4. The tooth mobility at the 3-, 6-, and 12-month postoperative examination was significantly decreased, compared to that at the preoperative examination in both experimental and control group(P<0.005), but there was no significant difference between experimental group and control group. 5. Radiopacity of furcation area was greatly increased in the experiment group, but there was no radiographic change in the control group.

  • PDF

BONE RESPONSE OF THREE DIFFERENT SURFACE IMPLANTS : HISTOMORPHOMETRIC, PERIO TEST VALUE AND RESONANCE FREQUENCY ANALYSIS IN BEAGLE DOGS

  • Choi, Joon-Eon;Suh, Kyu-Won;Lee, In-Ku;Ryu, Jae-Jun;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.362-374
    • /
    • 2007
  • Statement of problem. The intial stability for osseointegration of implant has been an interesting factor. Especially, in the case of poor bone quality or immediately loaded implant, various strategies have been developed focusing on the surface of materials to improve implant fixation to bone. The microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Purpose. The aims of this study are to perform a histologic and histomorphometric comparison of the healing characteristics of three different surfaces and the comparison of resonance frequency analysis (RFA) values measured by $Osstell^{TM}$ and perio-test values (PTV) measured by Periotest. Material and methods. A total of 24 screw titanium implants (Dentium Co., Seoul, Korea) with 6mm in length and 3.4mm in diameter, were placed in the mandible of 4 beagle dogs. Implants were divided into three groups following the surface treatment methods: Group I is machined(control group). Group II is anodically oxidized. Group III is coated 500nm in thickness with hydroxyapatite(HA) by ion beam assisted deposition(IBAD) on the anodized oxidization. Bone blocks from 2 dogs were caught after 3 weeks of covered healing and another blocks from 2 dogs after 6 weeks. RFA values and PTV were measured right after insertion and at 3 and 6weeks. Histomorphometric analysis was made with Kappa Image Base System to calculate bone-to-implant contact (BIC) and bone area inside the threads. Pearson's correlation analyses were performed to evaluate the correlation between RFA and PTV, BIC and bone area ratio of three different surfaces at 3 and 6 weeks. Results. 1) In all surface treatment methods, the RFA values decreased and the PTV values increased until 6 weeks in comparison to initial values. 2) At 3 weeks, no significant difference was found from bone-to-implant contact ratio and bone area ratio of three different surface treatment methods(P>0.05). However, at 6 weeks, different surface treatment methods showed significantly different bone-toimplant contact ratio and bone area ratio(P<0.05). 3) In the implants with the IBAD on the anodic oxidization, significant difference was found between the 3 weeks and the 6 weeks bone area ratio(P<0.05). 4) Correlation was found between the RFA values and the bone area ratio at 3 and 6 weeks with significant difference(P<0.05). Conclusions. These results indicate that the implants with the IBAD on the anodic oxidization may have a high influence on the initial stability of implant.

Comparative Study Of Osseointergration On Different Immediate Implants In Extraction Sockets Of Beagle Dogs (성견에 발치 후 즉시 임플란트 식립시 RBM 처리된 임플란트의 골융합에 관한 연구)

  • Sun, Ki-Jong;Park, Jae-Young;Jung, Eun-Gyeong;Shin, Mee-Ran;Kim, Yun-Sang;Pi, Sung-Hee;Shin, Hyung-shik;You, Hyung-Keun
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.209-221
    • /
    • 2007
  • Recently, immediately after losing teeth. implant placement has been greatly attempted. Implant can help restoration of tooth functions within short time. This study was an attempt to examine the extent of osseointergation when the implants will be placed immediately after teeth extraction using domestic implant systems. Implants were inserted in beagle dogs and evaluated the clinical, radiological, histological and histomorphometric assay at 6 weeks and 12 weeks. For experimental materals, $STAGE-1^{(R)}$($4.1{\times}8mm$, Lifecore, USA), $SS-III^{(R)}$($4.0{\times}8mm$, OSSTEM, Korea) and $IFI^{(R)}$($4.0{\times}8mm$, Dio, Korea) implants treated with RBM were placed. All the placed site showed normal results without fail and inflammation clinically and radiologically. As a result of measurement by periotest, it showed $-2\;{\sim}\;-5$ and stable status comprehensively. There was no statistically significant difference among implants(p<0.05). Bone tissue adjacent to implant showed increased marrow tissue at 6 weeks. Nevertheless, osteogenic structure was not observed remarkably. In a 12 weeks opinion, bone tissue composed of osseointegration along implant interface showed significantly decreased marrow tissue containing central vessels unlike a 6 weeks opinion and matured compact bone whose osteogenic structure is well formed. BIC were 42.4%, 32.0% and 34.9%, respectively in 6 weeks and there was no statistically significant difference among group(p<0.05). In 12 weeks, BIC were 58.8%, 61.9% and 57.5%. respectively and there was no statistically significant difference among groups(p<0.05). It is considered that all 3 implant systems are suitable for immediate implant placement.