• Title/Summary/Keyword: Periodic table

Search Result 47, Processing Time 0.028 seconds

Measurement of Five DOF Motion Errors in the Ultra Precision Feed Tables (초정밀 이송테이블의 5 자유도 운동오차 측정)

  • Oh Yoon Jin;Park Chun Hong;Hwang Joo Ho;Lee Deug Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.11 s.176
    • /
    • pp.135-141
    • /
    • 2005
  • Measurement of five DOF motion errors in a ultra precision feed table was attempted in this study. Yaw and pitch error were measured by using a laser interferometer and roll error was measured by using the reversal method. Linear motion errors in the vertical and horizontal directions were measured by using the sequential two point method. In this case, influence of angular motion errors was compensated by using the previously measured ones by the laser interferometer and the reversal method. The capacitive type sensors and an optical straight edge were used in the reversal method and the sequential two point method. Influence of thermal deformation on sensor jig was investgated and minimized by the periodic measurement according to the variation of room temperature. Deviation of gain between sensors was also compensated using the step response data. 5 DOF motion errors of a hydrostatic table driven by the linear motor werer tested using the measurement method. In the horizontal direction, measuring accuracies for the linear and angular motion were within ${\pm}0.02\;{\mu}m$ and ${\pm}0.04$ arcsec, respectively. In the vertical direction, they were within ${\pm}0.02{\mu}m$ and ${\pm}0.05$ arcsec. From these results, it was found that the introduced measurement method was very effective to measure 5 DOF motion errors of the ultra precision feed tables.

1g Shaking Table Test on Soil and Stone-column Interaction Behavior under Seismic Loading (1g 진동대 실험을 이용한 지반-스톤칼럼의 상호작용 거동에 관한 연구)

  • Kim, Jin-Man;Ryu, Jeong-Ho;Kim, Mi-Na;Son, Su-Won
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.4
    • /
    • pp.115-124
    • /
    • 2012
  • The responses of stone column-improved ground under seismic loading are investigated using a series of 1g shaking table tests. These tests show similar results to those of one dimensional numerical models for stone column-improved ground based on Baez's assumption on the soil and stone-column interaction. The experimental and numerical results show that the stone column can prevent large shear deformations incurred due to cyclic softening in clayey deposits, but they also show that the surface acceleration in the improved clayey deposits may amplify more than that in unimproved clayey deposits when subjected to short periodic seismic motions.

Orthostatic Hypotension and Cognitive Function in Parkinson's Disease (파킨슨병에서 기립저혈압과 인지 기능의 관계)

  • Kim, Sooyoung;Lee, Juyoun;Oh, Eungseok;Sohn, Eun Hee;Lee, Ae Young
    • Journal of the Korean neurological association
    • /
    • v.36 no.4
    • /
    • pp.302-309
    • /
    • 2018
  • Background: Although orthostatic hypotension (OH) and cognitive impairment (CI) are common non- motor symptoms of Parkinson's disease (PD), the relationship between OH and CI remains to be clarified. This study was aimed to investigate the relationship between OH and CI in PD. Methods: We recruited 192 patients who were diagnosed as PD based on the UK Brain Bank diagnostic criteria. The Hoehn & Yahr stages were ranged I to III and patients underwent extensive clinical evaluation, including brain magnetic resonance imaging (MRI) for cerebral white matter hyperintensity (WMH), tilt table test, the Korean version of Montreal Cognitive Assessments and the Korean version of Mini-Mental Status Examination in one month from the first clinic visit. The participants were divided into two groups according to the presence of OH (OH+ vs. OH-) and cognitive function (cognitive normal, CN vs. CI), respectively. Results: Significant relationship between OH and cognitive function (p=0.04) was found in our patients. The patients with OH+ had higher risk of CI by 2.6 times than that of OH- patients. Maximum heart rate change during tilt table test was correlated with cognitive function and white matter changes, whereas blood pressure change during tilt table test showed no correlation with those parameters. Conclusions: There was significant relationship between OH and CI in PD. Therefore, PD patients with either symptom may need periodic evaluation and proper management for OH and cognitive functions.

Seismic Response of Stone Column-Improved Soft Clay Deposit by Using 1g Shaking Table (1g 진동대를 이용한 쇄석말뚝으로 개량된 연약점토 지반의 지진 응답 특성)

  • Kim, Jin-Man;Lee, Hyun-Jin;Ryu, Jeong-Ho
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.12
    • /
    • pp.61-70
    • /
    • 2010
  • A series of shaking table tests were conducted to estimate the seismic performance of soft ground deposits improved by stone column. The amplification of acceleration, shear strain, and shear wave velocity were evaluated to compare the seismic response of unimproved ground deposits with that of improved ground deposits. From the test results, it was shown that the stone column can prevent large shear deformation in ground deposits. However, it was also found that the acceleration of improved ground deposits may be amplified more than that of unimproved ground deposits when it was subjected to short periodic seismic wave. The results suggest that it is necessary to perform the ground response analysis with model experiments for both unimproved and improved ground deposits to evaluate the effect of stone column on the seismic performance of improved ground deposits.

Electronic State of ZnO doped with Al, Ga and In, Calculated by Density Functional Theory (범함수궤도법을 이용하여 계산한 Al, Ga, In이 도핑된 ZnO의 전자상태)

  • Lee, Dong-Yoon;Lee, Won-Jae;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.218-221
    • /
    • 2004
  • The electronic state of ZnO doped with Al, Ga and In, which belong to III family elements in periodic table, was calculated using the density functional theory. In this study, the program used for the calculation on theoretical structures of ZnO and doped ZnO was Vienna Ab-initio Simulation Package (VASP), which is a sort of pseudo potential method. The detail of electronic structure was obtained by the describe variational $X{\alpha}(DV-X{\alpha})$(DV-Xa) method, which is a sort of molecular orbital full potential method. The optimized crystal structures obtained by calculations were compared to the measured structure. The density of state and energy levels of dopant elements was shown and discussed in association with properties.

  • PDF

Investigation of the Actual Condition of Oral Health Concerns of Patients In Dental Clinics

  • Kim, Seung-Hee
    • Journal of Integrative Natural Science
    • /
    • v.13 no.2
    • /
    • pp.58-62
    • /
    • 2020
  • Many studies have demonstrated the Quality of Life to oral health of the periodic dental visitors. Despite of the theoretical importance, a critical determinants of oral health concern have not yet been identified by intuition. The purpose of the present study is : (1) to analyze the relationship between clinical oral health status and subjective oral health concern(self-rated); (2) use them as basic data to efficiently operate oral health management programs specializing in prevention. The distribution of oral health concerns differed depending only on whether or not oral health care was performed periodically (P<0.05, Table 1).

The Accuracy of the Table Movement During a Whole Body Scan (전신 영상 검사 시행 시 테이블 이동속도의 정확성에 관한 연구)

  • Lee, Ju-Young;Jung, Woo-Young;Jung, Eun-Mi;Dong, Kyung-Rae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.86-91
    • /
    • 2009
  • Purpose: The whole body scan in Nuclear Medicine is a widely accepted examination and procedure. Especially, it is mainly used in bone, I-131, MIBI, and HMPAO WBC scans. The diverse uses of the whole body scan range from the HMPAO WBC scan with a speed of 13cm/min, to a whole body bone scan using the Onco. Flash technique with a speed of 30cm/min. The accuracy of table movement has a strong correlation with the image quality, and inaccuracy of speed could negatively affect the image quality. The purpose of this study is to evaluate the accuracy of the table movement while considering the influence of the age of the equipment and the variability in the weight of the patients. Material and Methods: The study was conducted using two of Seoul Asan Medical Center's SIEMENS gamma cameras which are commonly used in our whole body study. The first one is the oldest gamma camera, an ECAM plus (installed in 2000), and the last is brand new one, a SYMBIA T2 (installed in 2008). Three trials were conducted with the tables moving at a different speed each time; 10, 15 and 30 cm/min. The tables' speeds were measured by checking how long it took for the table to move 10cm, and this was repeated every 10cm until the table reached 100 cm. With an average body weight of the patients of about 60~70 kg, the table speed was measured with weights of 0 kg, 66 kg and 110 kg placed on the table, then compared among conditions. Results: The coefficient of variance (CV) of the ECAM plus showed 1.23, 1.42, 2.02 respectively when the table movement speeds were set at 10, 15, and 30 centimeters per minute. Under the same conditions, the SYMBIA T2 showed 1.23, 1.83 and 2.28 respectively. As table movement speed more, the variance of CV as the speed increases. When the patient body weight was set to 0, 66 and 110kg, the CV values of both cameras showed 0.96, 1.45, 2.08 (0 Kg), 1.32, 1.72, 2.27 (66 Kg) and 1.37, 1.73, 2.14 (110 Kg). There was no significant difference (p>0.05) in 95 percent of confidence intervals and measured CV values were acceptable. However, the CV value of the SYMBIA T2 was relatively larger than the ECAM plus. Conclusion: The scan speed of the whole body scan is predetermined based on which examination is being performed. It is possible for the accuracy of the speed to be affected, such as the age of the equipment, the state of the bearings or the weight of a patient. These factors can have a negative impact on the diagnostic consistency and the image quality. Therefore, periodic quality control should be needed on the gamma cameras currently being used, focusing on the table movement speed in order to maintain accuracy and reproducibility.

  • PDF

The Relationship Analysis of the Korean Science Curriculum with the Chemistry Domains of the 8th Grade TIMSS 2019 (TIMSS 2019의 8학년 화학 영역과 우리나라 과학 교육과정의 비교 분석)

  • Kim, Hyun-Kyung
    • Journal of the Korean Chemical Society
    • /
    • v.64 no.6
    • /
    • pp.371-378
    • /
    • 2020
  • The purpose of this study is to analyze the relationship between the eight topics in TIMSS 2019 8th grade chemistry domains and the Korea 2009 Revised Science Curriculum and the 2015 Revised Science Curriculum. For this purpose, four elementary and four secondary teachers participated in physics, chemistry, biology and earth science majors, and two science education experts participated in analyzing in which grades the content elements of the TIMSS 2019 science framework are covered in the Korean science curriculum. The study also analyzed whether the content of the Korean science curriculum matches the 246 items of 8th grade in the TIMSS 2019 assessment and reflects in which grades the eight topics are covered. The results of this study are as follows. First, among the TIMSS 2019 evaluation topics, topics not covered at all in the Korean middle school curriculum were periodic table, matter and energy in chemical reactions, the role of electrons in chemical bonds. Second, the topic of "the periodic table as an organizing principle for the known elements" needs to be introduced in the Korean middle school curriculum, and topics such as "familiar exothermic and endothermic reactions" and "factors affecting the reaction rates" need to be discussed in consideration of the flow of international curricula. Third, the next science curriculum should be structured so that the sequence of chemistry contents and scope, especially core concepts to be included in the elementary, secondary, and higher education curriculum is linked to continuity.

Electrochemical Behaviors of Binary Ti-Zr Alloys

  • Oh, M.Y.;Kim, W.G.;Choe, H.C.;Ko, Y.M.
    • Corrosion Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.89-92
    • /
    • 2009
  • Pure Ti as well as Ti-6Al-4V alloy exhibit excellent properties for dental implant applications. However, for a better biocompatibility it seems important to avoid in the composition the presence of V due to the toxic effects of V ion release. Thus Al and V free and composed of non-toxic element such as Nb, Zr alloys as biomaterials have been developed. Especially, Zr contains to same family in periodic table as Ti. The addition of Zr to Ti alloy has an excellent mechanical properties, good corrosion resistance, and biocompatibility. In this study, the electrochemical characteristics of Ti-Zr alloys for biomaterials have been investigated using by electrochemical methods. Methods: Ti-Zr(10, 20, 30 and 40 wt%) alloys were prepared by arc melting and homogenized for 24 hr at $1000^{\circ}C$ in argon atmosphere. Phase constitutions and microstructure of the specimens were characterized by XRD, OM and SEM. The corrosion properties of the specimens were examined through potentiodynamic test (potential range of -1500 ~ 2000 mV), potentiostatic test (const. potential of 300 mV) in artificial saliva solution by potentiostat (EG&G Co, PARSTAT 2273. USA).

A Study on the Standard Working Area by Somatometria (인체계측(人體計測)에 의(依)한 표준작업역(標準作業域)의 연구(硏究))

  • Lee, Sang-Do;Jeong, Jung-Hui
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.2 no.1
    • /
    • pp.61-78
    • /
    • 1976
  • The purpose of this study is to establish the horizontal and vertical working area which is dependent on measuring value of workers, body in order to make easy and stable working environments, and then to design the size of machines, tools and instruments in production factory because of making the practical production conditions which is the most suitable to human characteristics. But there is necessity that we have to review numeric value of measurement periodically because the size of workers' body is variable according to periodic and social circumstances. The establishment of standard working area after measurement enable us to make the best working conditions and we can design standard working table, optimum size of all machines and tools in production activity. Therefore, we can also acknowledge the importance of studying on human engineering because human engineering is necessary to reduction of fatigue in working, saving workers from industrial accidents, fail-safe system, improvement of productivity with increase in efficiency and etc. Finally, this study informs us that numeric value of measurement is larger than that of Japan, but not than that of America and Germany. So we can establish standard working area which is the most suitable for Korean inherence after measurement of detailed parts for workers' body.

  • PDF